Michał Ziemczonok
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michał Ziemczonok has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- Malgorzata Kujawinska
Warsaw University of Technology, Institute of Micromechanics and Photonics
16 shared publications - Arkadiusz Kuś
Warsaw University of Technology, Institute of Micromechanics and Photonics
11 shared publications - Wojciech Krauze
Warsaw University of Technology, Institute of Micromechanics and Photonics, Sw. A. Boboli 8 Street, 02-525 Warsaw, Poland
3 shared publications - Elif Sarinay Cenik
Department of Molecular Biosciences, University of Texas at Austin, Austin, TX, USA
2 shared publications - Jeongsoo Kim
Chandra Department of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX, USA
2 shared publications - Johann K. Eberhart
University of Texas at Austin
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5536
Accurate determination of the refractive index in biological tissues using limited-angle optical diffraction tomography: a case study on mouse retina
We present a comprehensive framework for quantitative refractive index (RI) determination in biological tissues using limited-angle optical diffraction tomography (LA-ODT), combining immersion matching, missing-cone error correction based on optical volume conservation, and layer-specific fill-factor analysis. This approach is demonstrated on the mouse retina, yielding accurate mean RI values for eight retinal layers under hydrated (PBS) conditions, and the RI distribution of non-aqueous tissue components. Comparison of formalin-fixed, paraffin-embedded (FFPE) specimens and frozen sections revealed no significant RI bias induced by FFPE processing. The proposed methodology provides a robust, quantitative, and transferable framework for RI characterization in diverse biological tissues.
- 7 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5536
Open AccessAccurate determination of the refractive index in biological tissues using limited-angle optical diffraction tomography: a case study on mouse retina
We present a comprehensive framework for quantitative refractive index (RI) determination in biological tissues using limited-angle optical diffraction tomography (LA-ODT), combining immersion matching, missing-cone error correction based on optical volume conservation, and layer-specific fill-factor analysis. This approach is demonstrated on the mouse retina, yielding accurate mean RI values for eight retinal layers under hydrated (PBS) conditions, and the RI distribution of non-aqueous tissue components. Comparison of formalin-fixed, paraffin-embedded (FFPE) specimens and frozen sections revealed no significant RI bias induced by FFPE processing. The proposed methodology provides a robust, quantitative, and transferable framework for RI characterization in diverse biological tissues.
- Open Access
- 25 September 2026
- Published by Wiley in Advanced Optical Materials
- Vol. 14 (37) , e71770
Turning Light Into Matter: Programmable Microstructures Via Dose Control in Two‐Photon Polymerization
In two‐photon polymerization (TPP), the degree of conversion (DC) of the resin affects a broad range of material properties including refractive index (RI), stiffness or shrinkage. Heterogeneous DC can substitute multimaterial or doped structures, and outright enable a new paradigm of bio‐mimicking or numerically optimized structure designs. This work presents a new approach to variable‐DC fabrication: structures are described as voxelized distributions of the desired material property, such as the RI, which the slicer converts into a dose distribution map addressed via printing laser power modulation. The versatility of this method is demonstrated by the fabrication of the C. elegans worm phantom with the most complex 3D RI distribution programmed to date, as the design was derived directly from the RI tomography imaging data. Optimized calibration methodology for the RI reveals excellent repeatability, accuracy ( 0.1%), uncertainty ( 0.001), and stability (1 year) of the RI across achievable DC. The presented workflow also enables grayscale lithography for reduced surface roughness and efficient precompensation strategies. In summary, this work provides an open source toolbox for augmenting TPP systems with a new degree of freedom and facilitates the widespread adoption of TPP fabrication with point‐wise dose control.
- 25 September 2026
- Published by Wiley in Advanced Optical Materials
- Vol. 14 (37) , e71770
Open AccessTurning Light Into Matter: Programmable Microstructures Via Dose Control in Two‐Photon Polymerization
In two‐photon polymerization (TPP), the degree of conversion (DC) of the resin affects a broad range of material properties including refractive index (RI), stiffness or shrinkage. Heterogeneous DC can substitute multimaterial or doped structures, and outright enable a new paradigm of bio‐mimicking or numerically optimized structure designs. This work presents a new approach to variable‐DC fabrication: structures are described as voxelized distributions of the desired material property, such as the RI, which the slicer converts into a dose distribution map addressed via printing laser power modulation. The versatility of this method is demonstrated by the fabrication of the C. elegans worm phantom with the most complex 3D RI distribution programmed to date, as the design was derived directly from the RI tomography imaging data. Optimized calibration methodology for the RI reveals excellent repeatability, accuracy ( 0.1%), uncertainty ( 0.001), and stability (1 year) of the RI across achievable DC. The presented workflow also enables grayscale lithography for reduced surface roughness and efficient precompensation strategies. In summary, this work provides an open source toolbox for augmenting TPP systems with a new degree of freedom and facilitates the widespread adoption of TPP fabrication with point‐wise dose control.
- 21 August 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (34)
Inverse scattering in biological samples via beam propagation
Multiple scattering limits optical imaging in thick biological samples by scrambling sample-specific information. Physics-based inverse-scattering methods aim to computationally unscramble this information often by using nonconvex optimization solvers. However, their inherent nonconvexity often leads to highly sample-dependent performance and inaccurate reconstructions, particularly in strongly scattering specimens. Here, we introduce a novel inverse-scattering framework based on multislice beam propagation (MSBP) that robustly achieves high-quality scatter correction and label-free volumetric imaging across a diverse range of scattering biological samples. We rigorously benchmarked imaging performance across multiple MSBP solver implementations using both scattering calibration phantoms and biological specimens. We found that an amplitude-only cost function in the inverse solver, combined with angular and defocus diversity in the scattering measurements, enabled volumetric, label-free imaging with high-quality and subcellular-level scatter correction. Together, these results establish a foundation for the reliable application of inverse scattering to achieve biologically interpretable three-dimensional imaging in increasingly thick, multicellular samples, thus introducing a new paradigm for deep-tissue computational imaging.
- 21 August 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (34)
Inverse scattering in biological samples via beam propagation
Multiple scattering limits optical imaging in thick biological samples by scrambling sample-specific information. Physics-based inverse-scattering methods aim to computationally unscramble this information often by using nonconvex optimization solvers. However, their inherent nonconvexity often leads to highly sample-dependent performance and inaccurate reconstructions, particularly in strongly scattering specimens. Here, we introduce a novel inverse-scattering framework based on multislice beam propagation (MSBP) that robustly achieves high-quality scatter correction and label-free volumetric imaging across a diverse range of scattering biological samples. We rigorously benchmarked imaging performance across multiple MSBP solver implementations using both scattering calibration phantoms and biological specimens. We found that an amplitude-only cost function in the inverse solver, combined with angular and defocus diversity in the scattering measurements, enabled volumetric, label-free imaging with high-quality and subcellular-level scatter correction. Together, these results establish a foundation for the reliable application of inverse scattering to achieve biologically interpretable three-dimensional imaging in increasingly thick, multicellular samples, thus introducing a new paradigm for deep-tissue computational imaging.
- 19 May 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (11) , 3052-3055
Wavefront imaging with low coherence illumination simplifies the optical diffraction tomography setup and improves the signal-to-noise ratio
We present the employment of wavefront imaging using Quadriwave Lateral Shearing Interferometry (QLSI) for Optical Diffraction Tomography (ODT) reconstructions. Compared to a conventional Digital Holographic (DH) Interferometer, QLSI does not require a reference beam. It can also work efficiently with an incoherent source and hence reduces the speckle noise. Furthermore, QLSI is almost insensitive to phase wrapping, thus avoiding artefacts and easing the signal processing in ODT. We validate the method by reconstructing the 3D refractive index (3DRI) of a polystyrene bead via angle-scan diffraction tomography. The 3DRI reconstruction of the nano-printed phantom cell and the living yeast cell is also presented.
- 19 May 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (11) , 3052-3055
Wavefront imaging with low coherence illumination simplifies the optical diffraction tomography setup and improves the signal-to-noise ratio
We present the employment of wavefront imaging using Quadriwave Lateral Shearing Interferometry (QLSI) for Optical Diffraction Tomography (ODT) reconstructions. Compared to a conventional Digital Holographic (DH) Interferometer, QLSI does not require a reference beam. It can also work efficiently with an incoherent source and hence reduces the speckle noise. Furthermore, QLSI is almost insensitive to phase wrapping, thus avoiding artefacts and easing the signal processing in ODT. We validate the method by reconstructing the 3D refractive index (3DRI) of a polystyrene bead via angle-scan diffraction tomography. The 3DRI reconstruction of the nano-printed phantom cell and the living yeast cell is also presented.
- Open Access
- 7 January 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1)
OSI-flex: Optimization-based shearing interferometry for joint phase and shear estimation using a flexible open-source framework
Shearing interferometry is a common-path quantitative phase imaging technique in which an object beam interferes with a laterally shifted replica of itself, providing high temporal stability, reduced sensitivity to environmental noise, compact design, and compatibility with partially coherent illumination that suppresses coherence-related artifacts. Its principal limitation, however, is that it yields only sheared phase-difference measurements rather than the absolute phase, thereby requiring an additional reconstruction step. In this work, we introduce OSI-flex, a flexible, open-source computational framework for quantitative phase reconstruction from sheared phase-difference measurements. The method leverages modern machine learning tools, namely automatic differentiation, and the advanced ADAM (Adaptive Moment Estimation) optimizer. The method simultaneously refines the phase distribution and estimates the shear values, enabling adaptation to experimental conditions where the shear cannot be precisely determined. Because defining shear value is inherently difficult in most systems, yet crucial for effective phase reconstruction, this joint optimization leads to robust and reliable phase retrieval. The proposed OSI-flex framework is highly versatile, supporting arbitrary numbers, magnitudes, and orientations of shear vectors. While optimal reconstruction is achieved with two orthogonal shear directions, the inclusion of regularization—specifically total variation minimization and sign constraint—enables OSI-flex to remain effective with nonorthogonal or even single-shear measurements. Moreover, the algorithm accommodates a wide range of shear magnitudes, from subpixel shifts (differential configuration) to several dozen pixels (semi-total shear configuration). Validation with simulations and experimental data confirms quantitative accuracy on calibrated phase objects and demonstrates robustness with 3D-printed cell phantom and follicular thyroid cells.
- 7 January 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1)
Open AccessOSI-flex: Optimization-based shearing interferometry for joint phase and shear estimation using a flexible open-source framework
Shearing interferometry is a common-path quantitative phase imaging technique in which an object beam interferes with a laterally shifted replica of itself, providing high temporal stability, reduced sensitivity to environmental noise, compact design, and compatibility with partially coherent illumination that suppresses coherence-related artifacts. Its principal limitation, however, is that it yields only sheared phase-difference measurements rather than the absolute phase, thereby requiring an additional reconstruction step. In this work, we introduce OSI-flex, a flexible, open-source computational framework for quantitative phase reconstruction from sheared phase-difference measurements. The method leverages modern machine learning tools, namely automatic differentiation, and the advanced ADAM (Adaptive Moment Estimation) optimizer. The method simultaneously refines the phase distribution and estimates the shear values, enabling adaptation to experimental conditions where the shear cannot be precisely determined. Because defining shear value is inherently difficult in most systems, yet crucial for effective phase reconstruction, this joint optimization leads to robust and reliable phase retrieval. The proposed OSI-flex framework is highly versatile, supporting arbitrary numbers, magnitudes, and orientations of shear vectors. While optimal reconstruction is achieved with two orthogonal shear directions, the inclusion of regularization—specifically total variation minimization and sign constraint—enables OSI-flex to remain effective with nonorthogonal or even single-shear measurements. Moreover, the algorithm accommodates a wide range of shear magnitudes, from subpixel shifts (differential configuration) to several dozen pixels (semi-total shear configuration). Validation with simulations and experimental data confirms quantitative accuracy on calibrated phase objects and demonstrates robustness with 3D-printed cell phantom and follicular thyroid cells.
- Open Access
Inverse-scattering in biological samples via beam-propagation
Multiple scattering limits optical imaging in thick biological samples by scrambling sample-specific information. Physics-based inverse-scattering methods aim to computationally recover this information, often using non-convex optimization to reconstruct the scatter-corrected sample. However, this non-convexity can lead to inaccurate reconstructions, especially in highly scattering samples. Here, we show that various implementation strategies for even the same inverse-scattering method significantly affect reconstruction quality. We demonstrate this using multi-slice beam propagation (MSBP), a relatively simple nonconvex inverse-scattering method that reconstructs a scattering sample’s 3D refractive-index (RI). By systematically conducting MSBP-based inverse-scattering on both phantoms and biological samples, we showed that an amplitude-only cost function in the inverse-solver, combined with angular and defocus diversity in the scattering measurements, enabled high-quality, fully-volumetric RI imaging. This approach achieved subcellular resolution and label-free 3D contrast across diverse, multiple-scattering samples. These results lay the groundwork for robust use of inverse-scattering techniques to achieve biologically interpretable 3D imaging in increasingly thick, multicellular samples, introducing a new paradigm for deep-tissue computational imaging.
Open AccessInverse-scattering in biological samples via beam-propagation
Multiple scattering limits optical imaging in thick biological samples by scrambling sample-specific information. Physics-based inverse-scattering methods aim to computationally recover this information, often using non-convex optimization to reconstruct the scatter-corrected sample. However, this non-convexity can lead to inaccurate reconstructions, especially in highly scattering samples. Here, we show that various implementation strategies for even the same inverse-scattering method significantly affect reconstruction quality. We demonstrate this using multi-slice beam propagation (MSBP), a relatively simple nonconvex inverse-scattering method that reconstructs a scattering sample’s 3D refractive-index (RI). By systematically conducting MSBP-based inverse-scattering on both phantoms and biological samples, we showed that an amplitude-only cost function in the inverse-solver, combined with angular and defocus diversity in the scattering measurements, enabled high-quality, fully-volumetric RI imaging. This approach achieved subcellular resolution and label-free 3D contrast across diverse, multiple-scattering samples. These results lay the groundwork for robust use of inverse-scattering techniques to achieve biologically interpretable 3D imaging in increasingly thick, multicellular samples, introducing a new paradigm for deep-tissue computational imaging.
- Open Access
- 4 June 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (12) , 25198-25209
Coded wavefront sensing for video-rate quantitative phase imaging and tomography: validation with digital holographic microscopy
We demonstrate coded wavefront sensing (Coded WFS) for video-rate quantitative phase imaging and 3D refractive index (RI) tomography of biological specimens. To evaluate the accuracy, we implement an experimental setup that supports measurements of specimens with Coded WFS as well as with digital holographic microscopy (DHM) under identical conditions, enabling direct comparison. We image a static 3D phantom fabricated via additive manufacturing and a rotating HEK293 cell in an acoustofluidic chamber. Our results demonstrate good agreement between the two methods, with the advantage that, in contrast to DHM, Coded WFS enables simple integration with standard microscopes. Furthermore, we apply a standard tomographic reconstruction algorithm to the HEK293 cell data for comparison, which demonstrates the potential of Coded WFS in tomography.
- 4 June 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (12) , 25198-25209
Open AccessCoded wavefront sensing for video-rate quantitative phase imaging and tomography: validation with digital holographic microscopy
We demonstrate coded wavefront sensing (Coded WFS) for video-rate quantitative phase imaging and 3D refractive index (RI) tomography of biological specimens. To evaluate the accuracy, we implement an experimental setup that supports measurements of specimens with Coded WFS as well as with digital holographic microscopy (DHM) under identical conditions, enabling direct comparison. We image a static 3D phantom fabricated via additive manufacturing and a rotating HEK293 cell in an acoustofluidic chamber. Our results demonstrate good agreement between the two methods, with the advantage that, in contrast to DHM, Coded WFS enables simple integration with standard microscopes. Furthermore, we apply a standard tomographic reconstruction algorithm to the HEK293 cell data for comparison, which demonstrates the potential of Coded WFS in tomography.
- Open Access
- 15 April 2025
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 45 (2) , 247-257
Tailored 3D microphantoms: An essential tool for quantitative phase tomography analysis of organoids
- 15 April 2025
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 45 (2) , 247-257
Open AccessTailored 3D microphantoms: An essential tool for quantitative phase tomography analysis of organoids
- Open Access
- 22 January 2025
- Published by Elsevier in Measurement
- Vol. 247
Bio-inspired 3D-printed phantom: Encoding cellular heterogeneity for characterization of quantitative phase imaging
- 22 January 2025
- Published by Elsevier in Measurement
- Vol. 247
Open AccessBio-inspired 3D-printed phantom: Encoding cellular heterogeneity for characterization of quantitative phase imaging
- Open Access
- 24 June 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 73
Phase-assisted multi-material two-photon polymerization for extended refractive index range
- 24 June 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 73
Open AccessPhase-assisted multi-material two-photon polymerization for extended refractive index range