KTKim Trenbath

Kim Trenbath

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kim Trenbath has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    JUMP Into STEM 2018-2025: Challenge Highlights and Implementation Guidance

    by Nehemiah Emaikwu, Kim Trenbath, Caroline Hazard, Grant Wheeler, Bethany Sparn, Ryan Meyer, Heather Goetsch, Juan Catano

    Building sciences and technology directly impact human health, productivity, and resource consumption (e.g., energy and critical minerals). Addressing emerging challenges in this field requires skilled building science professionals. JUMP into STEM sought to inspire the next generation of building scientists through a real-world competition that introduced participants to the field and connected them with national laboratory and industry professionals. This report highlights select challenges from past competitions which are tailored for academic and industry professionals who aim to develop or recruit multidisciplinary talent. It also includes additional guidance to support the effective replication of these challenges.

  • Open Access

    Exploring Professor Motivations and Implementations of a Real-World Problem-Solving Project

    by Benjamin Bruxvoort, Kim Trenbath

    Engineering education literature offers a variety of theoretical and conceptual frameworks for project-based learning. This study explores the implementation of real-world problem-solving projects in engineering education. The research team analyzed the motivations and methods behind professors' adoption of such projects through exploratory qualitative interviews with seven professor participants who integrated a nation-wide student competition into their courses. We analyzed the resulting data using a constructivist grounded theory approach to identify key themes of professor practices. Findings reveal that the real-world aspect of the projects and alignment with values and research interests were primary motivators for implementation. While implementation methods varied significantly based on context (i.e., university setting, course type), we found that these projects could be effectively integrated into various classroom settings. The findings support the recommendation for non-academic institutions to develop and manage competitions that can be integrated into classrooms and which offer a point of engagement that is available to professors from a wide range of disciplines.

  • Open Access

    Monitoring Home Electrical Power Consumption Patterns Using Secondary Wireless Meters

    by Prateek Shrestha, Kim Trenbath

    This report presents analysis of high-temporal-resolution whole-house electrical consumption data obtained from 17 residential buildings located in the Denver metro and Aspen regions of Colorado as well as survey data collected from the participants related to building characteristics and equipment types. The electrical consumption (load) data were obtained using wireless devices manufactured by Copper Labs, Inc. that collected data being broadcast from advanced metering infrastructure (AMI) or automated meter reading (AMR) -type whole-house electrical meters and relayed the data to a central server. Traditional metering systems, which typically collect data at hourly or daily intervals, lack the granularity required to capture nuanced energy behaviors, such as the power cycles of individual appliances or brief but intense usage spikes. By using minute-resolution data collection, this study uncovers valuable insights into household electricity use, identifying peak load times and patterns that contribute to unnecessary energy use. NREL worked with Copper Labs, a Colorado utility (Holy Cross Energy) and other local agencies (BrightVault, LLC., City of Boulder Climate Initiatives, Rocky Mountain Institute, Xcel Energy, and CET and Associates) to identify houses with suitable AMI/AMR meters. The participants from the identified houses were recruited through NREL internally (NREL employees' homes). The anonymized data generated by this study were shared with the participants and will be made publicly available for future researchers. In this study, we first evaluate the general characteristics of raw time series data and 24-hour average load profile for specific houses that participated in the study. We also present the aggregate data analysis after down-selecting houses with overlapping data collection periods. We then perform categorical comparisons of aggregated data that highlight features of the electrical power load being influenced by factors such as the presence of rooftop solar photovoltaics (PV), electrical versus gas appliances for space and water heating, number of occupants, and occupants working from home. Although the analysis presented here is performed in a small sample size after down-selecting (n=17), we present the data collected from all the houses that participated in the study in the appendices of this report. From our data analysis, we first note that houses with rooftop solar PV systems have drastically different load profiles compared to houses without rooftop PV systems. Instead of the morning and evening peaks expected in a load profile, houses with rooftop solar PV tend to have a dip toward the middle of the day and have little or no significant peak during the morning and evening hours. We noted that majority of the time, we can expect houses to experience roughly half a kilowatt of average load and peak loads of roughly 12 kW. Single-family detached houses have slightly greater (roughly 200 W more) average load, but a much wider load range (the difference between maximum and minimum) of power loads compared to multifamily apartment building units. There is also an increasing trend for the power load ranges with increasing square footage. Houses with less than 1,000 sq. ft. area can be expected to have significantly less power load than bigger houses. Houses with electric vehicles (EV) have roughly the same median load, but a much wider range of loads. Rooftop solar PV systems significantly reduce the median load by up to half a kilowatt. In terms of load categorization by space heating type, the difference in overall loads are very small across houses heated with gas, heat pumps, and propane in a colder day. Since our data mostly stretch across the cooling season, we also analyzed the load patterns for cooling system types categorized as heat pumps and traditional central air conditioning types. During a heat wave event, houses with heat pumps can experience lower median and peak loads compared to houses with traditional central air conditioning systems. Houses with electric water heaters have a lower median load than those with electric heat pump water heater systems but almost double the load range. Houses with electric induction stoves have higher loads than those with electric resistance stoves. But houses with electric resistance stoves have a much wider range of load. In terms of the number of occupants, the median load is only slightly different between houses with 2, 3, or 4 occupants. Houses with maximum work-from-home fraction also have the highest variability in the power load. And finally, newer houses do not necessarily have lower load, but a much wider range of load. Ultimately, this report emphasizes the importance of high temporal resolution in advancing both individual energy efficiency and larger sustainability goals.

  • Open Access

    Overview of Building Electrification Technologies and Market Opportunities

    by Kelsea Dombrovski, Heather Goetsch, Omkar Ghatpande, Jeff Maguire, Kim Trenbath

    This report provides an overview of building electrification drivers and select building electrification technologies and their markets and performance. Covered topics: Building Electrification Drivers and Context; Heat Pumps for Space Conditioning; Heat Pump Market Opportunities; Life Cycle GHG Emissions Impacts of Heat Pump Space Conditioning Technologies; Heat Pump Water Heaters; Electrification of Gas Loads: Commercial and Residential; Residential Panel Capacity; Electric Vehicle Impacts and Connections to Buildings; and Building Envelope Improvements and Thermal Energy Storage (TES) Opportunities.


  • Open Access

    Pathways to commercial building plug and process load efficiency and control

    by Amy Van Sant, Omkar Ghatpande, Robin Tuttle, Kim Trenbath

    To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.


  • Open Access

    Medical Imaging Equipment Energy Efficiency [Slides]

    by Kim Trenbath, Omkar Ghatpande, Amy LeBar

    The slide deck is being prepared for healthcare sector stakeholders as a resource on the energy use of Medical Imaging Equipment (MIE) which will provide an overview of existing work, review existing literature on MIE energy use and identify energy efficiency opportunities.


  • Commercial Building Sensors and Controls Systems - Barriers, Drivers, and Costs

    by Kim Trenbath, Ryan Meyer, Korbaga Woldekidan, Kristi Maisha, Morgan Harris

    Optimized building sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. However, only 8% of small commercial buildings have installed sensors and controls systems-which is largely due to cost barriers. This publication seeks to increase the transparency of system costs and identify specific barriers and drivers for increased adoption. Qualitative interview data was collected from 20 interviews with industry and qualitative cost data was collected from invoices during the interviews. The greater understanding of costs and barriers associated with commercial building sensors and controls systems lays the groundwork for future steps in increasing system adoption, reducing energy consumption, and market transformation.


  • End-Use Load Profiles for the U.S. Building Stock: Methodology and Results of Model Calibration, Validation, and Uncertainty Quantification

    by Eric J. H. Wilson, Andrew Parker, Anthony Fontanini, Elaina Present, Janet L. Reyna, Rajendra Adhikari, Carlo Bianchi, Christopher CaraDonna, Matthew Dahlhausen, Janghyun Kim, et al.

    The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High- quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation (Frick, Eckman, and Goldman 2017; Frick 2019). To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project - End-Use Load Profiles for the U.S. Building Stock - that culminated in the release of a publicly available dataset1 of simulated EULPs representing residential and commercial buildings across the contiguous United States. The motivation for this work is further detailed in a November 2019 report: Market Needs, Use Cases, and Data Gaps (Mims Frick et al. 2019). This Methodology and Results report provides detailed descriptions of how the dataset was developed, intended for an audience of dataset and model users interested in the technical details. These details include descriptions of all of the model improvements made for calibration and the final comparisons to empirical data sources. A companion report, End-Use Load Profiles for the U.S. Building Stock: Applications and Opportunities, will be published subsequently and will describe example applications and considerations for using the dataset, intended for an audience of general dataset users.


  • Provider and User Perspectives on Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

    by Grant Wheeler, Michael Deru, Adam Hirsch, Thien-Kim L. Trenbath

    The goal of this project was to understand, based on the primary reporting of AFDD providers and building owners, 1) the features currently available for RTU AFDD in the market today, 2) how RTU AFDD is used by building owners and managers, 3) how well RTU AFDD meets their needs, and 4) what barriers stand in the way of its broad industry adoption. To achieve this goal, 13 AFDD providers were asked about their products and seven building owners were questioned about their practical experience related to the automated detection, diagnosis, and communication of RTU faults.