Beatriz Alonso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Beatriz Alonso has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- María Guembe
Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain; Department of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, Madrid, Spain
13 shared publications - María Jesús Pérez-Granda
Clinical Microbiology and Infectious Diseases Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain
8 shared publications Raquel Cruces
Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain
6 shared publicationsCarlos Sánchez-Carrillo
5 shared publicationsPatricia Muñoz
Department of Clinical Microbiology and Infectious Diseases, Hospital General Universitário Gregorio Marañón, Madrid, Spain
5 shared publications- Emilio Bouza
Department of Clinical Microbiology and Infectious Diseases; Gregorio Marañón Institute of Health Research (IiSGM); Department of Medicine, Faculty of Medicine, Complutense University. Madrid, Spain
4 shared publications
Latest Publications
- 1 February 2021
- Published by Elsevier in Enfermedades Infecciosas y Microbiología Clínica
- Vol. 39 (2) , 72-77
How should microbiology laboratories interpret cultures of the sonicate of closed needleless connectors?
- 1 February 2021
- Published by Elsevier in Enfermedades Infecciosas y Microbiología Clínica
- Vol. 39 (2) , 72-77
How should microbiology laboratories interpret cultures of the sonicate of closed needleless connectors?
- Open Access
- 11 December 2020
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 20 (1) , 1
Correction to: Characterization of the virulence of Pseudomonas aeruginosa strains causing ventilator-associated pneumonia
An amendment to this paper has been published and can be accessed via the original article.
- 11 December 2020
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 20 (1) , 1
Open AccessCorrection to: Characterization of the virulence of Pseudomonas aeruginosa strains causing ventilator-associated pneumonia
An amendment to this paper has been published and can be accessed via the original article.
- Open Access
- 1 December 2020
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 20 (1) , 1-8
Characterization of the virulence of Pseudomonas aeruginosa strains causing ventilator-associated pneumonia
Background: The objective of this study was to evaluate the virulence of P. aeruginosa ventilator-associated pneumonia (VAP) strains (cases) in terms of biofilm production and other phenotypic and genotypic virulence factors compared to P. aeruginosa strains isolated from other infections (controls). Methods: Biofilm production was tested to assess biomass production and metabolic activity using crystal violet binding assay and XTT assay, respectively. Pigment production (pyocyanin and pyoverdine) was evaluated using cetrimide agar. Virulence genes were detected by conventional multiplex PCR and virulence was tested in an in vivo model in Galleria mellonella larvae. Results: We did not find statistically significant differences between VAP and no-VAP strains (p > 0.05) regarding biofilm production. VAP strains had no production of pyocyanin after 24 h of incubation (p = 0.023). The distribution of virulence genes between both groups were similar (p > 0.05). VAP strains were less virulent than non-VAP strains in an in vivo model of G. mellonella (p < 0.001). Conclusion: The virulence of VAP-Pseudomonas aeruginosa does not depend on biofilm formation, production of pyoverdine or the presence of some virulence genes compared to P. aeruginosa isolated from non-invasive locations. However, VAP strains showed attenuated virulence compared to non-VAP strains in an in vivo model of G. mellonella.
- 1 December 2020
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 20 (1) , 1-8
Open AccessCharacterization of the virulence of Pseudomonas aeruginosa strains causing ventilator-associated pneumonia
Background: The objective of this study was to evaluate the virulence of P. aeruginosa ventilator-associated pneumonia (VAP) strains (cases) in terms of biofilm production and other phenotypic and genotypic virulence factors compared to P. aeruginosa strains isolated from other infections (controls). Methods: Biofilm production was tested to assess biomass production and metabolic activity using crystal violet binding assay and XTT assay, respectively. Pigment production (pyocyanin and pyoverdine) was evaluated using cetrimide agar. Virulence genes were detected by conventional multiplex PCR and virulence was tested in an in vivo model in Galleria mellonella larvae. Results: We did not find statistically significant differences between VAP and no-VAP strains (p > 0.05) regarding biofilm production. VAP strains had no production of pyocyanin after 24 h of incubation (p = 0.023). The distribution of virulence genes between both groups were similar (p > 0.05). VAP strains were less virulent than non-VAP strains in an in vivo model of G. mellonella (p < 0.001). Conclusion: The virulence of VAP-Pseudomonas aeruginosa does not depend on biofilm formation, production of pyoverdine or the presence of some virulence genes compared to P. aeruginosa isolated from non-invasive locations. However, VAP strains showed attenuated virulence compared to non-VAP strains in an in vivo model of G. mellonella.
- Open Access
- 23 September 2020
- Published by Springer Nature in Annals of Clinical Microbiology and Antimicrobials
- Vol. 19 (1) , 1-11
Selective digestive decontamination solution used as “lock therapy” prevents and eradicates bacterial biofilm in an in vitro bench-top model
Background: Most preventing measures for reducing ventilator-associated pneumonia (VAP) are based mainly on the decolonization of the internal surface of the endotracheal tubes (ETTs). However, it has been demonstrated that bacterial biofilm can also be formed on the external surface of ETTs. Our objective was to test in vitro the efficacy of selective digestive decontamination solution (SDDs) onto ETT to prevent biofilm formation and eradicate preformed biofilms of three different microorganisms of VAP. Methods: We used an in vitro model in which we applied, at the subglottic space of ETT, biofilms of either P. aeruginosa ATCC 15442, or E. coli ATCC 25922, or S. aureus ATCC 29213, and the SDDs at the same time (prophylaxis) or after 72 h of biofilm forming (treatment). ETT were incubated during 5 days with a regimen of 2 h-locks. ETT fragments were analyzed by sonication and confocal laser scanning microscopy to calculate the percentage reduction of cfu and viable cells, respectively. Results: Median (IQR) percentage reduction of live cells and cfu/ml counts after treatment were, respectively, 53.2% (39.4%—64.1%) and 100% (100%–100.0%) for P. aeruginosa, and 67.9% (46.7%–78.7%) and 100% (100%–100.0%) for E. coli. S. aureus presented a complete eradication by both methods. After prophylaxis, there were absence of live cells and cfu/ml counts for all microorganisms. Conclusions: SDDs used as “lock therapy” in the subglottic space is a promising prophylactic approach that could be used in combination with the oro-digestive decontamination procedure in the prevention of VAP.
- 23 September 2020
- Published by Springer Nature in Annals of Clinical Microbiology and Antimicrobials
- Vol. 19 (1) , 1-11
Open AccessSelective digestive decontamination solution used as “lock therapy” prevents and eradicates bacterial biofilm in an in vitro bench-top model
Background: Most preventing measures for reducing ventilator-associated pneumonia (VAP) are based mainly on the decolonization of the internal surface of the endotracheal tubes (ETTs). However, it has been demonstrated that bacterial biofilm can also be formed on the external surface of ETTs. Our objective was to test in vitro the efficacy of selective digestive decontamination solution (SDDs) onto ETT to prevent biofilm formation and eradicate preformed biofilms of three different microorganisms of VAP. Methods: We used an in vitro model in which we applied, at the subglottic space of ETT, biofilms of either P. aeruginosa ATCC 15442, or E. coli ATCC 25922, or S. aureus ATCC 29213, and the SDDs at the same time (prophylaxis) or after 72 h of biofilm forming (treatment). ETT were incubated during 5 days with a regimen of 2 h-locks. ETT fragments were analyzed by sonication and confocal laser scanning microscopy to calculate the percentage reduction of cfu and viable cells, respectively. Results: Median (IQR) percentage reduction of live cells and cfu/ml counts after treatment were, respectively, 53.2% (39.4%—64.1%) and 100% (100%–100.0%) for P. aeruginosa, and 67.9% (46.7%–78.7%) and 100% (100%–100.0%) for E. coli. S. aureus presented a complete eradication by both methods. After prophylaxis, there were absence of live cells and cfu/ml counts for all microorganisms. Conclusions: SDDs used as “lock therapy” in the subglottic space is a promising prophylactic approach that could be used in combination with the oro-digestive decontamination procedure in the prevention of VAP.
Can vancomycin lock therapy extend the retention time of infected long‐term catheters?
We assessed the success rate of vancomycin catheter lock therapy (VLT) in combination with systemic antimicrobials in patients with staphylococcal catheter‐related bloodstream infection (C‐RBSI). Over a 6‐year period, we retrospectively collected clinical and microbiological data from patients with long‐term central venous catheters and staphylococcal C‐RBSI who were treated with systemic antimicrobials and VLT. We then assessed the success rate of VLT based on two criteria: 1) catheter retention time > 3 months and 2) catheter in place until end of use. We found 217 staphylococcal C‐RBSI episodes, 115 (53.0%) of which were managed with conservative therapy. Of these, 76 (66.1%) were treated with VLT (85.5% coagulase negative staphylococci and 14.5% Staphylococcus aureus). The success rate of VLT was 42.1% with criterion 1 and 71.1% with criterion 2. We did not find statistically significant differences between success and failure in the majority of the clinical data recorded. We only found differences for crude mortality in criterion 1 and for parenteral nutrition in criterion 2. The success of catheter retention using VLT was moderate, reaching slightly more than 70% when the catheter was kept in place until the end of use.
Can vancomycin lock therapy extend the retention time of infected long‐term catheters?
We assessed the success rate of vancomycin catheter lock therapy (VLT) in combination with systemic antimicrobials in patients with staphylococcal catheter‐related bloodstream infection (C‐RBSI). Over a 6‐year period, we retrospectively collected clinical and microbiological data from patients with long‐term central venous catheters and staphylococcal C‐RBSI who were treated with systemic antimicrobials and VLT. We then assessed the success rate of VLT based on two criteria: 1) catheter retention time > 3 months and 2) catheter in place until end of use. We found 217 staphylococcal C‐RBSI episodes, 115 (53.0%) of which were managed with conservative therapy. Of these, 76 (66.1%) were treated with VLT (85.5% coagulase negative staphylococci and 14.5% Staphylococcus aureus). The success rate of VLT was 42.1% with criterion 1 and 71.1% with criterion 2. We did not find statistically significant differences between success and failure in the majority of the clinical data recorded. We only found differences for crude mortality in criterion 1 and for parenteral nutrition in criterion 2. The success of catheter retention using VLT was moderate, reaching slightly more than 70% when the catheter was kept in place until the end of use.
- Open Access
- 22 August 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (8) , e0221702
Correction: Is heparinized 40% ethanol lock solution efficient for reducing bacterial and fungal biofilms in an in vitro model?
[This corrects the article DOI: 10.1371/journal.pone.0219098.].
- 22 August 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (8) , e0221702
Open AccessCorrection: Is heparinized 40% ethanol lock solution efficient for reducing bacterial and fungal biofilms in an in vitro model?
[This corrects the article DOI: 10.1371/journal.pone.0219098.].
- 1 August 2019
- Published by Elsevier in Fungal Genetics and Biology
- Vol. 129, 16-29
Genotypes and population genetics of cryptococcus neoformans and cryptococcus gattii species complexes in Europe and the mediterranean area
- 1 August 2019
- Published by Elsevier in Fungal Genetics and Biology
- Vol. 129, 16-29
Genotypes and population genetics of cryptococcus neoformans and cryptococcus gattii species complexes in Europe and the mediterranean area
- Open Access
- 8 July 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (7) , e0219098
Is heparinized 40% ethanol lock solution efficient for reducing bacterial and fungal biofilms in an in vitro model?
We applied an in vitro model to evaluate the efficacy of a heparinized 40% ethanol-based lock solution in a wide variety of clinical isolates causing C-RBSI. A total of 100 clinical strains were collected retrospectively from the blood of patients with C-RBSI. The reduction in biomass and metabolic activity of biofilms was measured using the crystal violet (CV) assay and XTT assay, respectively. Regrowth inhibition (RI) was measured within 24 hours and 72 hours of ethanol lock therapy. Percentage reduction of ≥ 85% in RI was considered to be successful. Ethanol lock was more effective in reducing metabolic activity than in reducing biomass (83% vs. 50%, respectively). Percentages of RI diminished as regrowth was prolonged (57% for 24 hours and 17% for 72 hours of regrowth). No statistically significant intraspecies differences were found in biofilm reduction or in RI (p>0.05). The use of heparinized 40% ethanol lock solution for 72 hours significantly reduced biomass and metabolic activity in clinical isolates from patients with C-RBSI. However, as biofilm has an important regrowth rate, 40% ethanol solution was not able to fully eradicate biofilm in vitro.
- 8 July 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (7) , e0219098
Open AccessIs heparinized 40% ethanol lock solution efficient for reducing bacterial and fungal biofilms in an in vitro model?
We applied an in vitro model to evaluate the efficacy of a heparinized 40% ethanol-based lock solution in a wide variety of clinical isolates causing C-RBSI. A total of 100 clinical strains were collected retrospectively from the blood of patients with C-RBSI. The reduction in biomass and metabolic activity of biofilms was measured using the crystal violet (CV) assay and XTT assay, respectively. Regrowth inhibition (RI) was measured within 24 hours and 72 hours of ethanol lock therapy. Percentage reduction of ≥ 85% in RI was considered to be successful. Ethanol lock was more effective in reducing metabolic activity than in reducing biomass (83% vs. 50%, respectively). Percentages of RI diminished as regrowth was prolonged (57% for 24 hours and 17% for 72 hours of regrowth). No statistically significant intraspecies differences were found in biofilm reduction or in RI (p>0.05). The use of heparinized 40% ethanol lock solution for 72 hours significantly reduced biomass and metabolic activity in clinical isolates from patients with C-RBSI. However, as biofilm has an important regrowth rate, 40% ethanol solution was not able to fully eradicate biofilm in vitro.
- 17 June 2019
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 38 (9) , 1737-1742
Evaluation of the Alfred™ turbidity monitoring system (Alifax®) following sonication in the diagnosis of central venous catheter colonization
The conventional diagnostic techniques for catheter colonization (CC) take at least 48 h to yield results. Therefore, new diagnostic procedures that speed up the time necessary for results are needed. Our main objective was to assess the efficacy of the combination of sonication, turbidity monitoring, and MALDI-TOF to detect CC and catheter-related bloodstream infection (C-RBSI). For 1 year, we assessed central venous catheter (CVC) tips that arrived at the microbiology laboratory from adult patients admitted to our institution. CVC tips were cut, inoculated into 2.5 ml of BHI, and sonicated for 1 min. The suspension was then processed using Gram stain, quantitative culture (gold standard), and preincubation on the Alfred™ system. We analyzed the validity values of our new diagnostic approach for prediction of CC and C-RBSI and compared them with those of the gold standard. We collected a total of 167 catheters, 33 (19.8%) of which were colonized. We confirmed 21 episodes of C-RBSI. The distribution of microorganisms in colonized CVCs was as follows: Gram-positive, 68.4%; Gram-negative, 5.3%; and yeasts, 26.3%. The validity values for CC and C-RBSI using the new procedure were as follows: S, 39.4%/61.9%; Sp, 100%/100%; PPV, 100%/100%; and NPV, 87.0%/94.8%. The combination of sonication with a pre-incubation period based on turbidity monitoring using the Alfred™ system followed by MALDI-TOF proved to be a useful tool that was faster than conventional culture for ruling out C-RBSI. Future studies are needed to assess the clinical and economic impact of this diagnostic approach.
- 17 June 2019
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 38 (9) , 1737-1742
Evaluation of the Alfred™ turbidity monitoring system (Alifax®) following sonication in the diagnosis of central venous catheter colonization
The conventional diagnostic techniques for catheter colonization (CC) take at least 48 h to yield results. Therefore, new diagnostic procedures that speed up the time necessary for results are needed. Our main objective was to assess the efficacy of the combination of sonication, turbidity monitoring, and MALDI-TOF to detect CC and catheter-related bloodstream infection (C-RBSI). For 1 year, we assessed central venous catheter (CVC) tips that arrived at the microbiology laboratory from adult patients admitted to our institution. CVC tips were cut, inoculated into 2.5 ml of BHI, and sonicated for 1 min. The suspension was then processed using Gram stain, quantitative culture (gold standard), and preincubation on the Alfred™ system. We analyzed the validity values of our new diagnostic approach for prediction of CC and C-RBSI and compared them with those of the gold standard. We collected a total of 167 catheters, 33 (19.8%) of which were colonized. We confirmed 21 episodes of C-RBSI. The distribution of microorganisms in colonized CVCs was as follows: Gram-positive, 68.4%; Gram-negative, 5.3%; and yeasts, 26.3%. The validity values for CC and C-RBSI using the new procedure were as follows: S, 39.4%/61.9%; Sp, 100%/100%; PPV, 100%/100%; and NPV, 87.0%/94.8%. The combination of sonication with a pre-incubation period based on turbidity monitoring using the Alfred™ system followed by MALDI-TOF proved to be a useful tool that was faster than conventional culture for ruling out C-RBSI. Future studies are needed to assess the clinical and economic impact of this diagnostic approach.
- 1 December 2018
- Published by Elsevier in Enfermedades Infecciosas y Microbiología Clínica
- Vol. 36 (10) , 627-632
In vitro assessment of the anti-biofilm activity of ethanol alone and in combination with enoxaparin 60 IU
- 1 December 2018
- Published by Elsevier in Enfermedades Infecciosas y Microbiología Clínica
- Vol. 36 (10) , 627-632
In vitro assessment of the anti-biofilm activity of ethanol alone and in combination with enoxaparin 60 IU