SYSteven Yee

Steven Yee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven Yee has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Charge-screening dominates signal transduction in electrochemical nucleic acid sensors for aminoglycosides

    by Steven Yee, Grace M. Maddocks, H. Tom Soh

    Electrochemical aptamer-based (EAB) sensors have emerged as a promising framework for reagentless, real-time molecular monitoring in complex biological matrices. Signal transduction in a prominent benchmark system—targeting aminoglycoside antibiotics—has been nearly universally attributed to target-specific, binding-induced conformational changes that modulate the distance between a redox reporter and the electrode surface. Here, using a suite of interfacial electrochemical and optical characterization methods, we systematically show that charge-screening, not structure switching, dominates the signaling mechanism in the case of the aminoglycoside EAB sensor. First, we demonstrate that the legacy aminoglycoside sensor sequence exhibits apparent affinities and relative electron kinetic modulations similar to unrelated control sequences, including generic stem-loop hairpins, unstructured poly-T sequences, and short duplexes. Multi-modal validation via bio-layer interferometry (BLI), circular dichroism (CD), and fluorescence spectroscopy confirms that this promiscuous target association occurs across disparate DNA sequences and without detectable conformational reconfiguration. Further investigation via charge-scaling polyamine assays and on-electrode fluorescence imaging demonstrate that the dominant signal transduction mechanism in these sensors is instead driven by macro-scale electrostatic backbone charge-screening.

  • Open Access

    Robust Regularization Enables Automated, Real-Time Square-Wave Voltammetry Signal Quantification

    by Max Yates, Jenny Ji, Steven Yee, Hyongsok Tom Soh

    Square-wave voltammetry (SWV) is widely used for electrochemical biosensing because it enables sensitive, temporally resolved measurement of redox reporter signals. However, automated quantification of SWV signal remains challenging for long duration and in vivo measurements, where voltammograms can exhibit changing baselines, heterogeneous noise, peak drift, outliers, and interfering faradaic processes. Here, we introduce the Adaptive Square-Wave Voltammetry Iterative Fitting Toolkit (ASWIFT), an automated method for robust SWV signal extraction based on iteratively reweighted regularized smoothing. ASWIFT is available as both an open-source Python package and a downloadable desktop application. The method adaptively estimates the baseline, selects regularization strengths, fits the redox peak, and reports peak height without trace-specific parameter tuning. Across simulated datasets spanning diverse baseline, peak, noise, and concentration-response conditions, ASWIFT produced less systematic bias and more consistent signal estimates than existing methods. We further evaluated ASWIFT using in vitro doxorubicin measurements and in vivo DNA-based kanamycin sensor measurements collected in rat blood and interstitial fluid, demonstrating agreement with established methods. These results support ASWIFT as a robust framework for automated SWV analysis in real-time electrochemical biosensing.


  • Open Access

    Continuous monitoring of blood–interstitial fluid intercompartmental molecular kinetics in freely moving animals

    by Yihang Chen, Qitao Hu, Jean Won Kwak, David Zakharian, Jenny Ji, Du Liu, Deepak Gopalan, Caoimhe Lyons, Max Yates, Steven Yee, et al.

    Accurate health monitoring depends on continuous assessment of biochemical markers across multiple body compartments. While blood remains the clinical gold standard, interstitial fluid (ISF) presents a minimally invasive alternative that reflects local tissue physiology, although its biomarker kinetics often differ from blood. It is currently impossible to achieve simultaneous, continuous monitoring of both compartments, limiting insight into their dynamic relationship. To address this, we present BICEP (blood-ISF continuous-sensing electrochemical probe), a wireless electrochemical platform for continuous dual-compartment monitoring of analytes in blood and ISF. The BICEP system incorporates microfabricated soft sensors with biofouling-resistant aptamer interfaces, paired with a wearable potentiostat for remote configuration and readout. Using this system, we continuously tracked kanamycin signal in both anesthetized and freely moving rats, revealing distinct kinetic profiles and individualized temporal delays between blood and ISF signals. These findings confirm that ISF is not merely a proxy for blood but exhibits unique molecular kinetics influenced by individual variability and physiological state. This platform advances personalized health monitoring by providing integrated, dynamic correlation of blood and ISF biomarkers, deepening understanding of their physiological interplay under real-life conditions and paving the way for broader use of wearable ISF-based biosensors.


  • Rapid, Sensitive Detection of Protein Biomarkers in Minimally‐Processed Blood Products with a Monolithic Sandwich Immunoassay Reagent

    by Nicolò Maganzini, Agnes Reschke, Alyssa P. Cartwright, Yasser Gidi, Ian Andrew Paul Thompson, Steven Yee, Amani Hariri, Constantin Dory, Yael Rosenberg‐Hasson, Jing Pan, et al.

    For more than fifty years, the enzyme‐linked immunosorbent assay (ELISA) serves as the gold standard for protein biomarker detection. However, conventional ELISA requires considerable sample preparation including reagent addition, incubation, and washing steps, limiting its usefulness at the point‐of‐care. In this work, the “instant ELISA” (fluorophore‐linked immunosorbent assay) biosensor that can measure protein biomarkers in the picomolar range within 15 min in undiluted plasma or serum with no sample preparation is described. The sensor leverages a synthetic reagent termed the “monolithic dual‐antibody clamp” (MDAC) which preserves the specificity, sensitivity, and generalizability of an ELISA, but produces a fluorescence signal as two surface‐tethered antibodies form a “sandwich” by binding to two distinct epitopes on the target. As exemplars, picomolar quantification of tumor necrosis factor alpha (TNFα) and monocyte chemotactic protein (MCP)‐1, the latter of which is a useful prognostic indicator of cytokine release syndrome in patient plasma samples during chimeric antigen receptor T cell therapy are demonstrated.


  • Open Access

    An antibody-based molecular switch for continuous small-molecule biosensing

    by Ian A.P. Thompson, Jason Saunders, Liwei Zheng, Amani A. Hariri, Nicolò Maganzini, Alyssa P. Cartwright, Jing Pan, Steven Yee, Constantin Dory, Michael Eisenstein, et al.

    We present a generalizable approach for designing biosensors that can continuously detect small-molecule biomarkers in real time and without sample preparation. This is achieved by converting existing antibodies into target-responsive “antibody-switches” that enable continuous optical biosensing. To engineer these switches, antibodies are linked to a molecular competitor through a DNA scaffold, such that competitive target binding induces scaffold switching and fluorescent signaling of changing target concentrations. As a demonstration, we designed antibody-switches that achieve rapid, sample preparation–free sensing of digoxigenin and cortisol in undiluted plasma. We showed that, by substituting the molecular competitor, we can further modulate the sensitivity of our cortisol switch to achieve detection at concentrations spanning 3.3 nanomolar to 3.3 millimolar. Last, we integrated this switch with a fiber optic sensor to achieve continuous sensing of cortisol in a buffer and blood with <5-min time resolution. We believe that this modular sensor design can enable continuous biosensor development for many biomarkers.


  • Optically Powered Milli-Scale Robot System for Nanoliter Fluid Delivery Based on Diamagnetic Levitation

    by Matthew Beauchamp, Steven Yee, Ina O’cArroll, Edward Chapman, Hatem ElBidweihy

    We demonstrate the use of a milli-scale robot setup to manipulate and transport nanoliter fluids based on diamagnetic levitation. Pyrolytic graphite (PyG) samples have been shown to passively levitate over permanent magnets with alternating poles and can be translated by low-power optical irradiation. Micropipettes attached to the surface of PyG samples are used to load fluids via capillary action and unload those fluids into an agarose, tissue-like gel through diffusion. The system features minimum friction and contact as well as simple actuation and control processes. This proof-of-concept demonstration paves the way for contactless nanoliter fluid delivery applications with temporal and spatial precision.


  • Open Access

    Photothermal actuation of levitated pyrolytic graphite revised

    by Steven Yee, Louisa Oney, Tyler Cosby, David P. Durkin, Hatem ElBidweihy

    The significant diamagnetism of pyrolytic graphite (PyG) allows it to be passively levitated above permanent magnet arrays and translated in the plane of these arrays via optical irradiation, which promotes applications in frictionless milli-scale robotics. Previous explanations for the translation effect have cited photothermal heating of levitated PyG and the thermal dependence of PyG’s magnetic susceptibility, as observed through measurements of samples at uniform temperatures. In this article, we offer a revision to the theory of photothermal actuation of levitated PyG. Through experiments and simulations, we demonstrate that the gradient of PyG’s diamagnetism with temperature—as measured for samples at uniform temperatures—is insufficient to explain the magnitude of forces required by the optically induced translation phenomenon. We hypothesize that the contrast in diamagnetism of PyG samples under asymmetric photothermal heating is at least an order of magnitude greater than that expected from measurements where the sample temperature is uniformly varied. We propose that the origin of the enhanced diamagnetic contrast under asymmetric optical irradiation is a photothermoelectric effect, which impacts the concentration of electrons in diamagnetically significant orbital states in graphite. To support this hypothesis, we take qualitative measurements, demonstrating the n-type thermoelectricity of PyG samples under optical irradiation while also characterizing the graphitic material with scanning electron microscopy/energy dispersive x-ray spectroscopy. We highlight the new understanding of the origin of the photothermal actuation through experiments using PyG samples with modified geometries that exhibit a pronounced preference in the axis of translation.


  • Self-powered high energy laser detectors via thermoelectric generators

    by Michael Seymour, Steven Yee, Charles Nelson, Brian Jenkins, Hatem ElBidweihy, Peter Joyce, Cody Brownell, Deborah Mechtel

    The prompt and accurate detection of laser strikes is increasingly important to the survivability of military assets in modern warfare as offensive and defensive laser weapon systems have become more widely implemented. Current laser detection systems on military assets can compromise an asset’s low observability features. This paper presents an addressed detection system based on an array of thermoelectric generators (TEGs) that can be integrated into the skin of an asset. An irradiated TEG harvests the incident energy of a high energy laser (HEL) strike to power a sensor node that transmits an address, via a wireless medium, to a reader in order to indicate which TEG within the array is being irradiated. The wireless sensor node consists of an ultralow voltage step-up converter and microcontroller and a low power RF link.

  • Open Access

    Manipulation of Microrobots Using Chladni Plates and Multimode Membrane Resonators

    by Lillian Ngo Usadi, Steven Yee, Hatem ElBidweihy, Samara Firebaugh

    (1) The advent of micro/nanorobotics promises to transform the physical, chemical, and biological domains by harnessing opportunities otherwise limited by size. Most notable is the biomedical field, in which the ability to manipulate micro/nanoparticles has numerous applications in biophysics, drug delivery, tissue engineering, and microsurgery. (2) Acoustics, the physics of vibrational waves through matter, offers a precise, accurate, and minimally invasive technique to manipulate microrobots or microparticles (stand-ins for microrobots). One example is through the use of flexural vibrations induced in resonant structures such as Chladni plates. (3) In this research, we developed a platform for precise two-dimensional microparticle manipulation via acoustic forces arising from Chladni figures and resonating microscale membranes. The project included two distinct phases: (i) macroscale manipulation with a Chladni plate in air; and (ii) microscale manipulation using microscale membranes in liquid. In the first phase (macroscale in air), we reproduced previous studies in order to gain a better understanding of the underlying physics and to develop control algorithms based on statistical modeling techniques. In the second phase (microscale in liquid), we developed and tested a new setup using custom microfabricated structures. The macroscale statistical modeling techniques were integrated with microscale autonomous control systems. It is shown that control methods developed on the macroscale can be implemented and used on the microscale with good precision and accuracy.


  • Open Access

    High-energy laser detection through thermoelectric generators

    by Joseph Merkel, Steven Yee, Charles Nelson, Brian Jenkins, Hatem ElBidweihy, Peter Joyce, Cody Brownell, Deborah Mechtel

    Optical Engineering (OE) publishes peer-reviewed papers reporting on research, development, and applications of optics, photonics, and imaging science and engineering.