Jeffrey Caudill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeffrey Caudill has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Patricia Gilbert
California Department of Parks and Recreation, Aquatic Invasive Species Branch, Division of Boating and Waterways, Sacramento, USA
2 shared publications - Pramod Pandey
Department of Population Health and Reproduction, School of Veterinary Medicine, University of California, Davis, CA 95616, USA
2 shared publications - Aditya Pandey
Department of Electrical and Computer Engineering, University of California at Davis, Davis, CA 95616, USA
1 shared publication - Jon O’bRien
California Department of Parks and Recreation, Aquatic Invasive Species Branch, Division of Boating and Waterways, Sacramento, USA
1 shared publication - Latika Singh
Department of Pharmacology, University of California, Davis, Davis, CA, 95616, United States
1 shared publication - Lydia Kenison
California Department of Parks and Recreation, Aquatic Invasive Species Branch, Division of Boating and Waterways, Sacramento, USA
1 shared publication
Latest Publications
- Open Access
- 15 April 2025
- Published by Springer Nature in Discover Water
- Vol. 5 (1) , 1-17
Multivariate analysis of water quality of Sacramento-San Joaquin Delta
- 15 April 2025
- Published by Springer Nature in Discover Water
- Vol. 5 (1) , 1-17
Open AccessMultivariate analysis of water quality of Sacramento-San Joaquin Delta
- Open Access
- 21 June 2019
- Published by Springer Nature in AMB Express
- Vol. 9 (1) , 1-11
Development of extraction and detection method for fluridone in water and sediment by HPLC-UV
Fluridone is widely used as a herbicide for controlling invasive aquatic plants such as hydrilla in surface water bodies. When applied on surface waters fluridone can attach to bed sediment, requiring rigorous extraction methods prior to analysis. Currently, very limited information exists in terms of fluridone residue detection in delta sediment. In this study, we researched fluridone detection in both water and sediment. To extract fluridone from sediment, here we have tested two extraction methods: (1) a rotavapor method (RM); and (2) a quick, easy, cheap, effective, rugged and safe (QuEChERS) method (QM). The extraction results of RM were compared with those of QM. To quantify fluridone concentrations in extracts, a high-performance liquid chromatography (HPLC)-UV detector was used. HPLC separation was achieved using an Allure C18 5 µm 150 × 4.6 mm column with a mobile phase composed of acetonitrile and water (60:40, v/v). The UV detector was operated at 237 nm. The method was tested and validated using a series of water and sediment samples taken from Sacramento–San Joaquin Delta in California. The average recovery of fluridone was 73% and 78% using RM and QM respectively. The proposed method can be used for testing fluridone in water and sediment samples.
- 21 June 2019
- Published by Springer Nature in AMB Express
- Vol. 9 (1) , 1-11
Open AccessDevelopment of extraction and detection method for fluridone in water and sediment by HPLC-UV
Fluridone is widely used as a herbicide for controlling invasive aquatic plants such as hydrilla in surface water bodies. When applied on surface waters fluridone can attach to bed sediment, requiring rigorous extraction methods prior to analysis. Currently, very limited information exists in terms of fluridone residue detection in delta sediment. In this study, we researched fluridone detection in both water and sediment. To extract fluridone from sediment, here we have tested two extraction methods: (1) a rotavapor method (RM); and (2) a quick, easy, cheap, effective, rugged and safe (QuEChERS) method (QM). The extraction results of RM were compared with those of QM. To quantify fluridone concentrations in extracts, a high-performance liquid chromatography (HPLC)-UV detector was used. HPLC separation was achieved using an Allure C18 5 µm 150 × 4.6 mm column with a mobile phase composed of acetonitrile and water (60:40, v/v). The UV detector was operated at 237 nm. The method was tested and validated using a series of water and sediment samples taken from Sacramento–San Joaquin Delta in California. The average recovery of fluridone was 73% and 78% using RM and QM respectively. The proposed method can be used for testing fluridone in water and sediment samples.