Andrew Olivo-Payne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew Olivo-Payne has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Alejandro Lichtinger
Department of Cornea and Refractive Surgery, Institute of Ophthalmology "Conde de Valenciana", Cuauhtémoc 06800, Mexico City, Mexico
3 shared publicationsAlexandra Abdala-Figuerola
Cornea Department, Grupo Oftalmologico Abdala-Figuerola, Barranquilla, Colombia
3 shared publicationsArturo Ramirez-Miranda
Department of Cornea and Refractive Surgery, Institute of Ophthalmology "Conde de Valenciana", Cuauhtémoc 06800, Mexico City, Mexico
3 shared publicationsErick Hernandez-Bogantes
Cornea Department, Centro Ocular, Heredia, Costa Rica
3 shared publicationsJuan Carlos Serna-Ojeda
Department of Cornea and Refractive Surgery, Institute of Ophthalmology "Conde de Valenciana", Cuauhtémoc 06800, Mexico City, Mexico
3 shared publicationsLucero Pedro-Aguilar
Instituto de Oftalmología Fundación Conde de Valenciana, Mexico City, Mexico
3 shared publications
Latest Publications
- Open Access
- 1 July 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 1183-1191
Optimal management of pediatric keratoconus: challenges and solutions
Keratoconus (KC) shows several distinctive features in clinical appearance, disease progression, and treatment in children compared with adults. Therefore, diagnostic, clinical care, and therapeutic approaches are different. However, pediatric keratoconus is often undiagnosed and thus untreated in many cases. Once diagnosis has been made, compliance with treatment recommendations is often poor. Pediatric keratoconus also tends to have more rapid progression than in adults; therefore, early detection and treatment are paramount to prevent serious vision impairment, which can affect the child’s development. This review of pediatric keratoconus discusses important issues such as worldwide epidemiology, clinical features in children compared to adults, and challenges in diagnosis and treatment and focuses on the most appropriate management strategies based on the best available current evidence.
- 1 July 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 1183-1191
Open AccessOptimal management of pediatric keratoconus: challenges and solutions
Keratoconus (KC) shows several distinctive features in clinical appearance, disease progression, and treatment in children compared with adults. Therefore, diagnostic, clinical care, and therapeutic approaches are different. However, pediatric keratoconus is often undiagnosed and thus untreated in many cases. Once diagnosis has been made, compliance with treatment recommendations is often poor. Pediatric keratoconus also tends to have more rapid progression than in adults; therefore, early detection and treatment are paramount to prevent serious vision impairment, which can affect the child’s development. This review of pediatric keratoconus discusses important issues such as worldwide epidemiology, clinical features in children compared to adults, and challenges in diagnosis and treatment and focuses on the most appropriate management strategies based on the best available current evidence.
- Open Access
- 18 December 2017
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 10 (12) , 1919-1921
Trans-epithelial accelerated corneal cross-linking for keratoconus in children
The aim of the study is to evaluate the safety and efficacy of trans-epithelial accelerated corneal cross-linking (TE-ACXL) in children with progressive keratoconus. Retrospective, case-series of 23 eyes of 14 children who underwent TE-ACXL. Evaluations were performed at baseline and 1, 3, 6, 12 and 18mo postoperatively. Mean follow-up time of 23.82±3.15mo and mean age was 13.7±1.4y (range 11 to 16y). Mean preoperative uncorrected distance visual acuity changed from 0.92±0.45 logMAR (20/160) to 0.71±0.40 logMAR (20/100) (P=0.001). Mean keratometry (Km) changed from 53.87± 6.03 to 53.00±5.81 (P=0.001). Pachymetry did not have significant changes at last follow-up (P=0.30). The mean preoperative sphere was -5.58±2.48 and -4.89±4.66 D (P=0.11) at last follow-up; refractive cylinder from -5.58±2.48 to -5.02±2.23 (P=0.046). In conclusion, tomographic and refractive stability are shown in over 91% of eyes with pediatric progressive keratoconus who underwent TE-ACXL.
- 18 December 2017
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 10 (12) , 1919-1921
Open AccessTrans-epithelial accelerated corneal cross-linking for keratoconus in children
The aim of the study is to evaluate the safety and efficacy of trans-epithelial accelerated corneal cross-linking (TE-ACXL) in children with progressive keratoconus. Retrospective, case-series of 23 eyes of 14 children who underwent TE-ACXL. Evaluations were performed at baseline and 1, 3, 6, 12 and 18mo postoperatively. Mean follow-up time of 23.82±3.15mo and mean age was 13.7±1.4y (range 11 to 16y). Mean preoperative uncorrected distance visual acuity changed from 0.92±0.45 logMAR (20/160) to 0.71±0.40 logMAR (20/100) (P=0.001). Mean keratometry (Km) changed from 53.87± 6.03 to 53.00±5.81 (P=0.001). Pachymetry did not have significant changes at last follow-up (P=0.30). The mean preoperative sphere was -5.58±2.48 and -4.89±4.66 D (P=0.11) at last follow-up; refractive cylinder from -5.58±2.48 to -5.02±2.23 (P=0.046). In conclusion, tomographic and refractive stability are shown in over 91% of eyes with pediatric progressive keratoconus who underwent TE-ACXL.
- 20 July 2017
- Published by BMJ in British Journal of Ophthalmology
- Vol. 102 (4) , 544-548
Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia
Objective To assess anterior segment changes, including iridocorneal angle and vault, after toric and non-toric implantable collamer lens (ICL) V4c (STAAR Surgical AG) implantation under different lighting conditions. Methods Longitudinal, prospective, case series. Patients with high myopia (>6 dioptres) underwent toric and non-toric ICL V4c implantation. Optical coherence tomography measurements were taken under different lighting conditions preoperatively and at 1 week and 1, 6 and 12 months of follow-up. Results Seventy-six eyes of 42 patients underwent ICL V4c implantation. Mean age was 27.4 years (±5.14 years, range 20 to 39 years). The average iridocorneal angle showed a statistically significant decrease (pConclusion There is a significant reduction in the iridocorneal angle after ICL V4c implantation. Furthermore, there is a change under mesopic conditions in both the iridocorneal angle and vault during long-term follow-up.
- 20 July 2017
- Published by BMJ in British Journal of Ophthalmology
- Vol. 102 (4) , 544-548
Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia
Objective To assess anterior segment changes, including iridocorneal angle and vault, after toric and non-toric implantable collamer lens (ICL) V4c (STAAR Surgical AG) implantation under different lighting conditions. Methods Longitudinal, prospective, case series. Patients with high myopia (>6 dioptres) underwent toric and non-toric ICL V4c implantation. Optical coherence tomography measurements were taken under different lighting conditions preoperatively and at 1 week and 1, 6 and 12 months of follow-up. Results Seventy-six eyes of 42 patients underwent ICL V4c implantation. Mean age was 27.4 years (±5.14 years, range 20 to 39 years). The average iridocorneal angle showed a statistically significant decrease (pConclusion There is a significant reduction in the iridocorneal angle after ICL V4c implantation. Furthermore, there is a change under mesopic conditions in both the iridocorneal angle and vault during long-term follow-up.
- 1 October 2016
- Published by Wolters Kluwer Health in Cornea
- Vol. 35 (10) , 1368-1371
Scheimpflug and Optical Coherence Tomography Analysis of Posterior Keratoconus
Posterior keratoconus is a rare noninflammatory condition usually present at birth and sometimes related to developmental abnormalities. Posterior keratoconus is usually unilateral and can present as a generalized or localized change in posterior corneal curvature.
- 1 October 2016
- Published by Wolters Kluwer Health in Cornea
- Vol. 35 (10) , 1368-1371
Scheimpflug and Optical Coherence Tomography Analysis of Posterior Keratoconus
Posterior keratoconus is a rare noninflammatory condition usually present at birth and sometimes related to developmental abnormalities. Posterior keratoconus is usually unilateral and can present as a generalized or localized change in posterior corneal curvature.
- 8 August 2016
- Published by BMJ in British Journal of Ophthalmology
- Vol. 101 (5) , 634-639
Non-traumatic corneal perforations: aetiology, treatment and outcomes
Purpose To report aetiology, characteristics, treatment and main outcomes of non-traumatic corneal perforations in a single referral centre. Methods A retrospective review of clinical records of patients diagnosed with non-traumatic corneal perforation. The analysed data included demographic characteristics, medical history, initial and final corrected distance visual acuity (CDVA), perforation aetiology, size, location, initial therapy, surgical treatment, ocular integrity and complications. A comparison between non-infectious and infectious groups was performed. Different variables were analysed through a multiple logistic regression analysis for the probability to have at least one more procedure. Results We included 127 eyes of 116 patients with a mean age of 50 years and a mean follow-up of 11 months. The initial CDVA was 3.00 logarithm of the minimum angle of resolution (logMAR) and the final CDVA was 2.30 logMAR (p>0.5). Regarding treatment, of the 49 eyes with an initial cyanoacrylate patch, 35 eyes (71.4%) had at least one more procedure performed (p>0.001). In comparison, of the 49 eyes with an initial tectonic penetrating keratoplasty (PK), 33 (67.3%) eyes remained stable while 16 (32.7%) eyes needed one or more interventions (p=0.004). In a multiple logistic regression analysis, an initial cyanoacrylate patch represented a probability of 4.7 times to require a subsequent procedure in comparison with an initial PK. Overall, globe integrity was achieved in 96.1% of the cases. Conclusions Corneal perforations represent an important cause of ocular morbidity. The use of a cyanoacrylate patch is useful as an initial therapy in corneal perforations; however, procedures such as PK are often necessary to achieve anatomical success, especially in non-infectious aetiologies.
- 8 August 2016
- Published by BMJ in British Journal of Ophthalmology
- Vol. 101 (5) , 634-639
Non-traumatic corneal perforations: aetiology, treatment and outcomes
Purpose To report aetiology, characteristics, treatment and main outcomes of non-traumatic corneal perforations in a single referral centre. Methods A retrospective review of clinical records of patients diagnosed with non-traumatic corneal perforation. The analysed data included demographic characteristics, medical history, initial and final corrected distance visual acuity (CDVA), perforation aetiology, size, location, initial therapy, surgical treatment, ocular integrity and complications. A comparison between non-infectious and infectious groups was performed. Different variables were analysed through a multiple logistic regression analysis for the probability to have at least one more procedure. Results We included 127 eyes of 116 patients with a mean age of 50 years and a mean follow-up of 11 months. The initial CDVA was 3.00 logarithm of the minimum angle of resolution (logMAR) and the final CDVA was 2.30 logMAR (p>0.5). Regarding treatment, of the 49 eyes with an initial cyanoacrylate patch, 35 eyes (71.4%) had at least one more procedure performed (p>0.001). In comparison, of the 49 eyes with an initial tectonic penetrating keratoplasty (PK), 33 (67.3%) eyes remained stable while 16 (32.7%) eyes needed one or more interventions (p=0.004). In a multiple logistic regression analysis, an initial cyanoacrylate patch represented a probability of 4.7 times to require a subsequent procedure in comparison with an initial PK. Overall, globe integrity was achieved in 96.1% of the cases. Conclusions Corneal perforations represent an important cause of ocular morbidity. The use of a cyanoacrylate patch is useful as an initial therapy in corneal perforations; however, procedures such as PK are often necessary to achieve anatomical success, especially in non-infectious aetiologies.
- 1 December 2015
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 31 (12) , 854
More Than a Decade of Experience With Implantable Collamer Lens
Correspondence Free Andrew Olivo-Payne, MD; Arturo Gomez-Bastar, MD; Alejandro Lichtinger, MD; Arturo Ramirez-Miranda, MD; Enrique O. Graue-Hernandez, MD, MSc; Alejandro Navas, MD, MSc We read with great interest the article by Moya et al. in the August 2015 issue.1 The literature on long-term outcomes and complications of posterior chamber phakic intraocular lenses is scarce and the authors effectively describe their 12-year experience with implantable collamer lens (ICL) implantation. We reviewed 349 eyes of 216 patients, of which 155 (44.4%) were treated with spheric ICLs and 194 (55.6%) with toric ICLs.2 The mean follow-up was 47 ± 31 months (range: 3 to 127 months); however, the study included more than 40 cases with more than a decade follow-up. The preoperative spherical equivalent was −11.60 ± 5.12 diopters (D) compared with −16.90 ± 4.26 D in Moya et al.'s study. Our postoperative spherical equivalent was slightly better, −0.52 ± 1.03 versus −0.89 ± 1.26 D, perhaps due to a lower preoperative sphere, inclusion of hyperopic cases, and the use of toric ICLs. In our study, the preoperative uncorrected distance visual acuity was 1.72 ± 0.49 (20/1000 Snellen), which improved to 0.23 ± 0.22 (20/33 Snellen) (P < .001). The mean corrected distance visual acuity was 0.21 ± 0.17 (20/32 Snellen) preoperatively and 0.12 ± 0.138 (20/26 Snellen) postoperatively (P < .001). Moya et al.'s study had several strengths, such as the well-documented endothelial cell density of 2,586.61 ± 320.14 cells/mm2 preoperatively, 2,434.13 ± 290.12 cells/mm2 at 1-year follow-up, and 2,071.13 ± 361.84 cells/mm2 at the last visit, with a mean loss of 515.48 cells/mm2 (19.75%) in 12 years, which is similar to other studies with shorter follow-up.3,4 One of the strengths of our study was long-term vault measurements with anterior segment optical coherence tomography, a more objective method. The vault measurement at the last visit was 481 ± 185 µm2 in our study2 versus 444 ± 204 µm at 1 day and 242 ± 157 µm 12 years postoperatively.1 Postoperative complications were similar in both studies. We reported a total complication rate of 3.72% (13 eyes), 2% of which were ICL related and 1.72% related to myopia or other ocular pathologies,2 whereas Moya et al.'s study had 6.24% vitreoretinal-related complications. Interestingly, we did not observe any clinically relevant lens opacities, whereas Moya et al. reported 13.88% (20 eyes) with significant lens opacities and treated 7.63% (11 eyes) with bilensectomy.1 This specific complication correlated significantly (chi-square test, P = .007)1 to the V3 ICL model. Our ICL-related complications included a small vault (< 100 µm), which required an ICL exchange, two eyes had toric ICL rotation, and one case had recurrent uveitis that resolved with medical treatment. Other complications not related to the ICL included blunt trauma with related macular hemorrhage and ICL subluxation, myopic choroidal neovascularization, blunt trauma with endothelial failure treated with Descemet's stripping automated endothelial keratoplasty,5 and a rhegmatogenous retinal detachment after ICL implantation treated with a scleral buckle. The only two severe complications in our study included a patient who underwent ICL removal due to an unresponsive toxic anterior segment syndrome and one patient with endophthalmitis who lost 2 lines of corrected distance visual acuity after intravitreal therapy and vitrectomy. Overall, our aim is to complement Moya et al.'s outstanding study with our findings in a large sample with long-term follow-up of ICL and toric ICL implantation, including visual, refractive, and anatomical outcomes and postoperative complications. Andrew Olivo-Payne, MD Arturo Gomez-Bastar, MD Alejandro Lichtinger, MD Arturo Ramirez-Miranda, MD Enrique O. Graue-Hernandez, MD, MSc Alejandro Navas, MD, MSc Mexico City, Mexico The authors have no financial or proprietary interest in the materials presented herein. We would like to congratulate Gomez-Bastar et al. for their study regarding long-term outcomes after implanting posterior chamber phakic intraocular lenses (PIOLs) and its contribution to the current knowledge on the topic.1 Although the authors of this article used the same brand of posterior chamber PIOLs that we did,2 some differences limit the comparability of our studies. First of all, it must be remarked that the design of both studies is different. Although we conducted a longitudinal retrospective analysis, Gomez-Bastar et al. carried out a cross-sectional study. In this kind of design, different individuals with the same characteristics are compared while longitudinal studies track the same people over time. That explains why we decided to include only 144 eyes that were followed up for at least 12 years (patients who did not attend the examinations and those cases in which the posterior chamber PIOL was explanted after cataract...
- 1 December 2015
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 31 (12) , 854
More Than a Decade of Experience With Implantable Collamer Lens
Correspondence Free Andrew Olivo-Payne, MD; Arturo Gomez-Bastar, MD; Alejandro Lichtinger, MD; Arturo Ramirez-Miranda, MD; Enrique O. Graue-Hernandez, MD, MSc; Alejandro Navas, MD, MSc We read with great interest the article by Moya et al. in the August 2015 issue.1 The literature on long-term outcomes and complications of posterior chamber phakic intraocular lenses is scarce and the authors effectively describe their 12-year experience with implantable collamer lens (ICL) implantation. We reviewed 349 eyes of 216 patients, of which 155 (44.4%) were treated with spheric ICLs and 194 (55.6%) with toric ICLs.2 The mean follow-up was 47 ± 31 months (range: 3 to 127 months); however, the study included more than 40 cases with more than a decade follow-up. The preoperative spherical equivalent was −11.60 ± 5.12 diopters (D) compared with −16.90 ± 4.26 D in Moya et al.'s study. Our postoperative spherical equivalent was slightly better, −0.52 ± 1.03 versus −0.89 ± 1.26 D, perhaps due to a lower preoperative sphere, inclusion of hyperopic cases, and the use of toric ICLs. In our study, the preoperative uncorrected distance visual acuity was 1.72 ± 0.49 (20/1000 Snellen), which improved to 0.23 ± 0.22 (20/33 Snellen) (P < .001). The mean corrected distance visual acuity was 0.21 ± 0.17 (20/32 Snellen) preoperatively and 0.12 ± 0.138 (20/26 Snellen) postoperatively (P < .001). Moya et al.'s study had several strengths, such as the well-documented endothelial cell density of 2,586.61 ± 320.14 cells/mm2 preoperatively, 2,434.13 ± 290.12 cells/mm2 at 1-year follow-up, and 2,071.13 ± 361.84 cells/mm2 at the last visit, with a mean loss of 515.48 cells/mm2 (19.75%) in 12 years, which is similar to other studies with shorter follow-up.3,4 One of the strengths of our study was long-term vault measurements with anterior segment optical coherence tomography, a more objective method. The vault measurement at the last visit was 481 ± 185 µm2 in our study2 versus 444 ± 204 µm at 1 day and 242 ± 157 µm 12 years postoperatively.1 Postoperative complications were similar in both studies. We reported a total complication rate of 3.72% (13 eyes), 2% of which were ICL related and 1.72% related to myopia or other ocular pathologies,2 whereas Moya et al.'s study had 6.24% vitreoretinal-related complications. Interestingly, we did not observe any clinically relevant lens opacities, whereas Moya et al. reported 13.88% (20 eyes) with significant lens opacities and treated 7.63% (11 eyes) with bilensectomy.1 This specific complication correlated significantly (chi-square test, P = .007)1 to the V3 ICL model. Our ICL-related complications included a small vault (< 100 µm), which required an ICL exchange, two eyes had toric ICL rotation, and one case had recurrent uveitis that resolved with medical treatment. Other complications not related to the ICL included blunt trauma with related macular hemorrhage and ICL subluxation, myopic choroidal neovascularization, blunt trauma with endothelial failure treated with Descemet's stripping automated endothelial keratoplasty,5 and a rhegmatogenous retinal detachment after ICL implantation treated with a scleral buckle. The only two severe complications in our study included a patient who underwent ICL removal due to an unresponsive toxic anterior segment syndrome and one patient with endophthalmitis who lost 2 lines of corrected distance visual acuity after intravitreal therapy and vitrectomy. Overall, our aim is to complement Moya et al.'s outstanding study with our findings in a large sample with long-term follow-up of ICL and toric ICL implantation, including visual, refractive, and anatomical outcomes and postoperative complications. Andrew Olivo-Payne, MD Arturo Gomez-Bastar, MD Alejandro Lichtinger, MD Arturo Ramirez-Miranda, MD Enrique O. Graue-Hernandez, MD, MSc Alejandro Navas, MD, MSc Mexico City, Mexico The authors have no financial or proprietary interest in the materials presented herein. We would like to congratulate Gomez-Bastar et al. for their study regarding long-term outcomes after implanting posterior chamber phakic intraocular lenses (PIOLs) and its contribution to the current knowledge on the topic.1 Although the authors of this article used the same brand of posterior chamber PIOLs that we did,2 some differences limit the comparability of our studies. First of all, it must be remarked that the design of both studies is different. Although we conducted a longitudinal retrospective analysis, Gomez-Bastar et al. carried out a cross-sectional study. In this kind of design, different individuals with the same characteristics are compared while longitudinal studies track the same people over time. That explains why we decided to include only 144 eyes that were followed up for at least 12 years (patients who did not attend the examinations and those cases in which the posterior chamber PIOL was explanted after cataract...