Sodeh Sadjadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sodeh Sadjadi has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Seyed Javad Ahmadi
Material and Nuclear Fuel School Nuclear Science and Technology Research Institute End of North Karegar Ave., Po. Box: 14399‐51113 Tehran Iran
10 shared publicationsMorteza Hosseinpour
Department of Energy Engineering , Sharif University of Technology , Tehran , Iran
6 shared publications- Seyed Javad Ahmadi
Nuclear Science and Technology Research Institute
3 shared publications - Mahdi Sadeghi
Medical Physics Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
2 shared publications - Mohamadreza K. Bakht
Young Researchers and Elites Club, Science and Research Branch, Islamic Azad University, Tehran, Iran
2 shared publications Mohammad Outokesh
Sharif University of Technology
2 shared publications
Latest Publications
- Open Access
- 3 August 2026
- Published by Brieflands in Iranian Journal of Pharmaceutical Research
- Vol. 25 (1) , e172717
Radiolabeling of Amberlite IRA-68 Resin Microspheres with Rhenium-188: Optimization and Biodistribution in Tumor-Bearing Mice Following Intratumoral Administration
Background: Rhenium-188 (188Re) is a therapeutic radionuclide with favorable nuclear properties, including high beta energy and a suitable half-life, making it attractive for radiopharmaceutical applications. Solid carriers, such as ion-exchange resins, may improve radionuclide stability, loading efficiency, and controlled delivery. Objectives: This study aimed to activate Amberlite IRA-68 anion-exchange resin microspheres, optimize their labeling with rhenium and 188Re, and evaluate the biodistribution of the radiolabeled microspheres following intratumoral injection in tumor-bearing mice at 24 and 48 h post-administration. Methods: The effects of contact time, temperature, pH, and initial rhenium concentration on labeling efficiency were systematically investigated. Resin labeling was evaluated by elemental composition analysis using a scanning electron microscope (SEM) equipped with an energy-dispersive X-ray (EDX) analyzer. Radiochemical purity was assessed by instant thin-layer chromatography (ITLC). Activity distribution in mouse organs was assessed using the ISOMED 1010 dose calibrator. Results: The results demonstrated high labeling efficiency; under optimal conditions (rhenium initial concentration 10 ppm, pH 7, 25 °C, 120 min), rhenium uptake reached approximately 98%. Following intratumoral administration, the radiolabeled microspheres showed high tumor retention (5.39%ID/g at 24 h), whereas radioactivity in the blood and normal organs remained relatively low. This retention indicates localized persistence of the injected microspheres rather than active biological targeting. These findings support the potential of Amberlite IRA-68 resin microspheres as an effective carrier for 188Re-based radiopharmaceutical applications. Conclusions: In this study, Amberlite IRA-68 anion-exchange resin microspheres were successfully evaluated as a carrier system for rhenium and rhenium-188. The results demonstrated high labeling efficiency, reaching approximately 98% under optimized conditions (10 ppm, pH 7, 25 °C, 120 min), indicating a strong affinity between the resin and perrhenate ions. The biodistribution study demonstrated that 188Re-labeled Amberlite IRA-68 microspheres showed favorable in vivo characteristics following intratumoral administration. The radiopharmaceutical showed high tumor accumulation at 24 h (%ID/g = 5.39), with persistent retention at 48 h and low blood activity, indicating minimal systemic leakage and limited uptake in critical organs.
- 3 August 2026
- Published by Brieflands in Iranian Journal of Pharmaceutical Research
- Vol. 25 (1) , e172717
Open AccessRadiolabeling of Amberlite IRA-68 Resin Microspheres with Rhenium-188: Optimization and Biodistribution in Tumor-Bearing Mice Following Intratumoral Administration
Background: Rhenium-188 (188Re) is a therapeutic radionuclide with favorable nuclear properties, including high beta energy and a suitable half-life, making it attractive for radiopharmaceutical applications. Solid carriers, such as ion-exchange resins, may improve radionuclide stability, loading efficiency, and controlled delivery. Objectives: This study aimed to activate Amberlite IRA-68 anion-exchange resin microspheres, optimize their labeling with rhenium and 188Re, and evaluate the biodistribution of the radiolabeled microspheres following intratumoral injection in tumor-bearing mice at 24 and 48 h post-administration. Methods: The effects of contact time, temperature, pH, and initial rhenium concentration on labeling efficiency were systematically investigated. Resin labeling was evaluated by elemental composition analysis using a scanning electron microscope (SEM) equipped with an energy-dispersive X-ray (EDX) analyzer. Radiochemical purity was assessed by instant thin-layer chromatography (ITLC). Activity distribution in mouse organs was assessed using the ISOMED 1010 dose calibrator. Results: The results demonstrated high labeling efficiency; under optimal conditions (rhenium initial concentration 10 ppm, pH 7, 25 °C, 120 min), rhenium uptake reached approximately 98%. Following intratumoral administration, the radiolabeled microspheres showed high tumor retention (5.39%ID/g at 24 h), whereas radioactivity in the blood and normal organs remained relatively low. This retention indicates localized persistence of the injected microspheres rather than active biological targeting. These findings support the potential of Amberlite IRA-68 resin microspheres as an effective carrier for 188Re-based radiopharmaceutical applications. Conclusions: In this study, Amberlite IRA-68 anion-exchange resin microspheres were successfully evaluated as a carrier system for rhenium and rhenium-188. The results demonstrated high labeling efficiency, reaching approximately 98% under optimized conditions (10 ppm, pH 7, 25 °C, 120 min), indicating a strong affinity between the resin and perrhenate ions. The biodistribution study demonstrated that 188Re-labeled Amberlite IRA-68 microspheres showed favorable in vivo characteristics following intratumoral administration. The radiopharmaceutical showed high tumor accumulation at 24 h (%ID/g = 5.39), with persistent retention at 48 h and low blood activity, indicating minimal systemic leakage and limited uptake in critical organs.
- 9 September 2023
- Published by Springer Nature in Journal of Material Cycles and Waste Management
- Vol. 25 (6) , 3567-3583
Biodiesel production from supernatant waste cooking oil by a simple one-step technique: calorific value optimization using response surface methodology (RSM) based on D-optimal design
- 9 September 2023
- Published by Springer Nature in Journal of Material Cycles and Waste Management
- Vol. 25 (6) , 3567-3583
Biodiesel production from supernatant waste cooking oil by a simple one-step technique: calorific value optimization using response surface methodology (RSM) based on D-optimal design
- Open Access
- 1 January 2020
- Vol. 2 (1) , 15-20
Magnetic functionalized graphene: An efficient and solid acid catalyst for the synthesis of highly functionalized pyrroles under ultrasound irradiation
- 1 January 2020
- Vol. 2 (1) , 15-20
Open AccessMagnetic functionalized graphene: An efficient and solid acid catalyst for the synthesis of highly functionalized pyrroles under ultrasound irradiation
- 10 July 2019
- Published by Wiley in Applied Organometallic Chemistry
- Vol. 33 (9) , e5085
Optimization of cadmium adsorption from aqueous solutions by functionalized graphene and the reversible magnetic recovery of the adsorbent using response surface methodology
Novel functionalized graphene adsorbent was prepared and characterized using different techniques. The prepared adsorbent was applied for the removal of cadmium ions from aqueous solution. A response surface methodology was used to evaluate the simple and combined effects of the various parameters, including adsorbent dosage, pH, and initial concentration. Under the optimal conditions, the cadmium removal performance of 70% was achieved. A good agreement between experimental and predicted data in this study was observed. The experimental results revealed of cadmium adsorption with high linearity follow Langmuir isotherm model with maximum adsorption capacity of 502 mg g−1, and the adsorption data fitted well into pseudo‐second order model. Thermodynamic studies showed that adsorption process has exothermic and spontaneous nature. The recommended optimum conditions are: cadmium concentration of 970 mg L−1, adsorbent dosage of 1 g L−1, pH of 6.18, and T = 25 °C.The magnetic recovery of the adsorbent was performed using a magnetic surfactant to form a noncovalent magnetic functionalized graphene. After magnetic recovery of the adsorbent both components (adsorbent and magnetic surfactant) were recycled by tuning the surface charges through changing the pH of the solution. Desorption behavior studied using HNO3 solution indicated that the adsorbent had the potential for reusability.
- 10 July 2019
- Published by Wiley in Applied Organometallic Chemistry
- Vol. 33 (9) , e5085
Optimization of cadmium adsorption from aqueous solutions by functionalized graphene and the reversible magnetic recovery of the adsorbent using response surface methodology
Novel functionalized graphene adsorbent was prepared and characterized using different techniques. The prepared adsorbent was applied for the removal of cadmium ions from aqueous solution. A response surface methodology was used to evaluate the simple and combined effects of the various parameters, including adsorbent dosage, pH, and initial concentration. Under the optimal conditions, the cadmium removal performance of 70% was achieved. A good agreement between experimental and predicted data in this study was observed. The experimental results revealed of cadmium adsorption with high linearity follow Langmuir isotherm model with maximum adsorption capacity of 502 mg g−1, and the adsorption data fitted well into pseudo‐second order model. Thermodynamic studies showed that adsorption process has exothermic and spontaneous nature. The recommended optimum conditions are: cadmium concentration of 970 mg L−1, adsorbent dosage of 1 g L−1, pH of 6.18, and T = 25 °C.The magnetic recovery of the adsorbent was performed using a magnetic surfactant to form a noncovalent magnetic functionalized graphene. After magnetic recovery of the adsorbent both components (adsorbent and magnetic surfactant) were recycled by tuning the surface charges through changing the pH of the solution. Desorption behavior studied using HNO3 solution indicated that the adsorbent had the potential for reusability.
- 14 February 2019
- Published by Springer Nature
- p. 687-715
Efficient Utilization of Supercritical Carbon Dioxide as Both Reactant and Reaction Medium for Synthetic Applications
- 14 February 2019
- Published by Springer Nature
- p. 687-715
Efficient Utilization of Supercritical Carbon Dioxide as Both Reactant and Reaction Medium for Synthetic Applications
- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 144 (3)
Effect of MWCNTs on the Performance of Mixed-Matrix Membranes in Removing Cerium Ions from Aqueous Feed Solutions
This study investigates the effect of multiwalled carbon nanotubes (MWCNTs) on the performance of polyethersulfone membranes in cerium ion removal from aqueous solution. Neat polyethersulfone (PES) membrane and mixed-matrix membranes (MMMs) containing MWCNTs are fabricated by the wet phase inversion technique. The MWCNTs are functionalized by (3-aminopropyl)-trimethoxysilane (APTMS) to improve their adhesion to the polymeric matrix. The MWCNTs (before and after functionalization) are analyzed using Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, and thermogravimetric analysis (TGA). Morphological properties of the fabricated membranes are evaluated by scanning electron microscopy (SEM) and field emission scanning electron microscopy (FESEM) methods. Fabricated membranes are subjected to further experiments in order to evaluate cerium ion removal efficiency. Permeation test results show that permeate flux and cerium (Ce) ion rejection increase as MWCNT content increases in the polymer matrix. The results also show that permeate flux and cerium ion rejection increase as operating pressure and feed flow rate increase while inversely decreased by increasing the cerium ion concentration in the feed solution. Application of ethylenediaminetetraacetic acid disodium (EDTA) drastically increases cerium ion rejection.
- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 144 (3)
Effect of MWCNTs on the Performance of Mixed-Matrix Membranes in Removing Cerium Ions from Aqueous Feed Solutions
This study investigates the effect of multiwalled carbon nanotubes (MWCNTs) on the performance of polyethersulfone membranes in cerium ion removal from aqueous solution. Neat polyethersulfone (PES) membrane and mixed-matrix membranes (MMMs) containing MWCNTs are fabricated by the wet phase inversion technique. The MWCNTs are functionalized by (3-aminopropyl)-trimethoxysilane (APTMS) to improve their adhesion to the polymeric matrix. The MWCNTs (before and after functionalization) are analyzed using Fourier-transform infrared spectroscopy (FTIR), Raman spectroscopy, and thermogravimetric analysis (TGA). Morphological properties of the fabricated membranes are evaluated by scanning electron microscopy (SEM) and field emission scanning electron microscopy (FESEM) methods. Fabricated membranes are subjected to further experiments in order to evaluate cerium ion removal efficiency. Permeation test results show that permeate flux and cerium (Ce) ion rejection increase as MWCNT content increases in the polymer matrix. The results also show that permeate flux and cerium ion rejection increase as operating pressure and feed flow rate increase while inversely decreased by increasing the cerium ion concentration in the feed solution. Application of ethylenediaminetetraacetic acid disodium (EDTA) drastically increases cerium ion rejection.
- 25 September 2017
- Published by Springer Nature
- p. 1-29
Efficient Utilization of Supercritical Carbon Dioxide as Both Reactant and Reaction Medium for Synthetic Applications
- 25 September 2017
- Published by Springer Nature
- p. 1-29
Efficient Utilization of Supercritical Carbon Dioxide as Both Reactant and Reaction Medium for Synthetic Applications
- 30 November 2015
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 13 (4) , 763-771
Decoration of electrospun polyacrylonitrile nanofibers with ZnO nanoparticles and their application for removal of Pb ions from waste water
- 30 November 2015
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 13 (4) , 763-771
Decoration of electrospun polyacrylonitrile nanofibers with ZnO nanoparticles and their application for removal of Pb ions from waste water
- 7 October 2015
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 51 (2) , 248-254
Selective solid-phase extraction of trace Pb(II) from aqueous solution using Pb(II)-ion imprinted polymer
In this work, we synthesized several ions imprinted polymers based on the inclusion of 8-hydroxyquinoline, vinyl benzoic acid, and diazoaminobenzene as ligands into the polymer matrix to complex with lead ions. Besides, to optimize various parameters for the selective extraction and enrichment of lead ions using the best synthesized imprinted polymers, the selectivity of the chosen inorganic ions was investigated. These investigations indicated that the synthesized imprinted polymer particles have good potential for selective enrichment of lead ions compared with other heavy metal ions, and the selectivity of lead ion-imprinted polymers for lead ion was higher than non-imprinted polymer.
- 7 October 2015
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 51 (2) , 248-254
Selective solid-phase extraction of trace Pb(II) from aqueous solution using Pb(II)-ion imprinted polymer
In this work, we synthesized several ions imprinted polymers based on the inclusion of 8-hydroxyquinoline, vinyl benzoic acid, and diazoaminobenzene as ligands into the polymer matrix to complex with lead ions. Besides, to optimize various parameters for the selective extraction and enrichment of lead ions using the best synthesized imprinted polymers, the selectivity of the chosen inorganic ions was investigated. These investigations indicated that the synthesized imprinted polymer particles have good potential for selective enrichment of lead ions compared with other heavy metal ions, and the selectivity of lead ion-imprinted polymers for lead ion was higher than non-imprinted polymer.
- Open Access
- 1 October 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (5) , 1403-1412
Synthesis of TiO2/polyacrylonitrile nanofibers composite and its application to lead ions removal from waste waters
The adsorption behavior of lead(II) from aqueous solutions utilizing TiO2/polyacrylonitrile (PAN) nanofibers was studied. TiO2/PAN nanofibers were prepared by electrospinning method and characterized by X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis (TGA), and scanning electron microscope. These data were utilized to show nanofibers and TiO2 nanoparticles morphology and existence of TiO2 in nanofibers web. The results show that the size of nanoparticles is about 70 nm and the fibers diameters is in the range of 1–2 μm. The changes in the parameters of adsorbent dosage, pH, contact time, TiO2 concentration, and temperature were tested in the adsorption experiments. The adsorption was well described by the Langmuir adsorption isotherm model. The thermodynamic parameters indicate that the adsorption process is spontaneous and endothermic. The pseudo-first-order kinetic model describes the dynamic behavior for the adsorption of lead(II) ions onto PAN/TiO2 nanofibers.
- 1 October 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 56 (5) , 1403-1412
Open AccessSynthesis of TiO2/polyacrylonitrile nanofibers composite and its application to lead ions removal from waste waters
The adsorption behavior of lead(II) from aqueous solutions utilizing TiO2/polyacrylonitrile (PAN) nanofibers was studied. TiO2/PAN nanofibers were prepared by electrospinning method and characterized by X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis (TGA), and scanning electron microscope. These data were utilized to show nanofibers and TiO2 nanoparticles morphology and existence of TiO2 in nanofibers web. The results show that the size of nanoparticles is about 70 nm and the fibers diameters is in the range of 1–2 μm. The changes in the parameters of adsorbent dosage, pH, contact time, TiO2 concentration, and temperature were tested in the adsorption experiments. The adsorption was well described by the Langmuir adsorption isotherm model. The thermodynamic parameters indicate that the adsorption process is spontaneous and endothermic. The pseudo-first-order kinetic model describes the dynamic behavior for the adsorption of lead(II) ions onto PAN/TiO2 nanofibers.