Masashi Yokose
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masashi Yokose has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Takahisa Goto
Department of Anaesthesiology and Critical Care Medicine, Yokohama City University Graduate School of Medicine, Yokohama, Japan
9 shared publications- Takahiro Mihara
Department of Health Data Science, Graduate School of Data Science, Yokohama City University, Yokohama, Japan
6 shared publications Yusuke Saigusa
Department of Biostatistics, Yokohama City University School of Medicine, Yokohama, Japan
6 shared publicationsHiroyuki Tanaka
Department of Anaesthesiology and Critical Care Medicine, Yokohama City University Graduate School of Medicine, Yokohama, Japan
4 shared publicationsShunsuke Takaki
Department of Anesthesiology and Critical Care Medicine, Yokohama City University Graduate School of Medicine, 3-9 Fukuura, Kanazawa-Ku, Yokohama, Japan
4 shared publicationsT. Goto
Department of Anaesthesiology and Critical Care Medicine, Yokohama City University School of Medicine, Yokohama, Japan
4 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 14 (1) , 145
Metabolic response during neuromuscular electrical stimulation in critically ill patients with deep sedation: a prospective observational study
Background: Neuromuscular electrical stimulation (NMES) is a potential strategy to counteract skeletal muscle atrophy in critically ill patients unable to engage in early mobilization. However, it is difficult to confirm whether the exercise load applied by NMES is sufficient to elicit a physiological effect in patients under sedation or with impaired consciousness, as the appropriate stimulus intensity and exercise load of NMES are generally assessed using subjective responses. This study aimed to evaluate changes in energy expenditure during NMES in sedated, mechanically ventilated patients using indirect calorimetry. Methods: This single-center observational study included 22 mechanically ventilated patients under deep sedation in the intensive care unit (ICU). Energy expenditure was measured using indirect calorimetry during NMES sessions. The primary outcome was the difference in energy expenditure before and during NMES. Multivariable linear regression analysis was performed to calculate the adjusted mean difference in energy expenditure. A clinically meaningful increase in energy expenditure attributable to NMES was predefined as 150 kcal/day, which was assumed based on an increase in energy expenditure when sitting on the edge of the bed. Results: In total, 26 NMES sessions involving 22 participants were included in the analysis. The mean energy expenditure was 1,137 ± 170 kcal/day pre-NMES and 1,350 ± 228 kcal/day during NMES. The adjusted increase in energy expenditure during NMES was 213.8 kcal/day (95% confidence interval, 137.1–290.3). This increase reached statistical significance when tested against the predefined threshold of 150 kcal/day ( P = 0.02). Conclusions: The exercise load provided by NMES could be objectively assessed by measuring increases in energy expenditure. Although a statistically significant increase in energy expenditure was observed during NMES compared to pre-NMES levels, the magnitude of this increase was minimal. Further research is needed to determine whether NMES protocols that enhance energy expenditure are associated with muscle mass preservation, strength maintenance, and the prevention of ICU-acquired weakness.
- 10 November 2026
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 14 (1) , 145
Open AccessMetabolic response during neuromuscular electrical stimulation in critically ill patients with deep sedation: a prospective observational study
Background: Neuromuscular electrical stimulation (NMES) is a potential strategy to counteract skeletal muscle atrophy in critically ill patients unable to engage in early mobilization. However, it is difficult to confirm whether the exercise load applied by NMES is sufficient to elicit a physiological effect in patients under sedation or with impaired consciousness, as the appropriate stimulus intensity and exercise load of NMES are generally assessed using subjective responses. This study aimed to evaluate changes in energy expenditure during NMES in sedated, mechanically ventilated patients using indirect calorimetry. Methods: This single-center observational study included 22 mechanically ventilated patients under deep sedation in the intensive care unit (ICU). Energy expenditure was measured using indirect calorimetry during NMES sessions. The primary outcome was the difference in energy expenditure before and during NMES. Multivariable linear regression analysis was performed to calculate the adjusted mean difference in energy expenditure. A clinically meaningful increase in energy expenditure attributable to NMES was predefined as 150 kcal/day, which was assumed based on an increase in energy expenditure when sitting on the edge of the bed. Results: In total, 26 NMES sessions involving 22 participants were included in the analysis. The mean energy expenditure was 1,137 ± 170 kcal/day pre-NMES and 1,350 ± 228 kcal/day during NMES. The adjusted increase in energy expenditure during NMES was 213.8 kcal/day (95% confidence interval, 137.1–290.3). This increase reached statistical significance when tested against the predefined threshold of 150 kcal/day ( P = 0.02). Conclusions: The exercise load provided by NMES could be objectively assessed by measuring increases in energy expenditure. Although a statistically significant increase in energy expenditure was observed during NMES compared to pre-NMES levels, the magnitude of this increase was minimal. Further research is needed to determine whether NMES protocols that enhance energy expenditure are associated with muscle mass preservation, strength maintenance, and the prevention of ICU-acquired weakness.
- Top Cited Papers
- 21 May 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 133 (1) , 24-32
Hypotension after general anaesthesia induction using remimazolam or propofol in geriatric patients undergoing sevoflurane anaesthesia with remifentanil: a single-centre, double-blind, randomised controlled trial
- 21 May 2024
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 133 (1) , 24-32
Top Cited PapersHypotension after general anaesthesia induction using remimazolam or propofol in geriatric patients undergoing sevoflurane anaesthesia with remifentanil: a single-centre, double-blind, randomised controlled trial
- 4 October 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (1) , 77-88
Measurement accuracy of a microwave doppler sensor beneath the mattress as a continuous respiratory rate monitor: a method comparison study
Purpose Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. Methods The respiratory rate of intensive care unit patients was simultaneously measured using a microwave Doppler sensor, capnography, thoracic impedance pneumography, and a piezoelectric sensor beneath the mattress. Bias and 95% limits of agreement between the respiratory rate measured using capnography (standard reference) and that measured using the other three methods were calculated using Bland–Altman analysis for repeated measures. Clarke error grid (CEG) analysis evaluated the sensor’s ability to assist in correct clinical decision-making. Results Eighteen participants were included, and 2,307 data points were analyzed. The bias values (95% limits of agreement) of the microwave Doppler sensor, thoracic impedance pneumography, and piezoelectric sensor were 0.2 (− 4.8 to 5.2), 1.5 (− 4.4 to 7.4), and 0.4 (− 4.0 to 4.8) breaths per minute, respectively. Clinical decisions evaluated using CEG analyses were correct 98.1% of the time for the microwave Doppler sensor, which was similar to the performance of the other devices. Conclusion The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low. Trial registration number : UMIN000038900, February 1, 2020.
- 4 October 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (1) , 77-88
Measurement accuracy of a microwave doppler sensor beneath the mattress as a continuous respiratory rate monitor: a method comparison study
Purpose Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. Methods The respiratory rate of intensive care unit patients was simultaneously measured using a microwave Doppler sensor, capnography, thoracic impedance pneumography, and a piezoelectric sensor beneath the mattress. Bias and 95% limits of agreement between the respiratory rate measured using capnography (standard reference) and that measured using the other three methods were calculated using Bland–Altman analysis for repeated measures. Clarke error grid (CEG) analysis evaluated the sensor’s ability to assist in correct clinical decision-making. Results Eighteen participants were included, and 2,307 data points were analyzed. The bias values (95% limits of agreement) of the microwave Doppler sensor, thoracic impedance pneumography, and piezoelectric sensor were 0.2 (− 4.8 to 5.2), 1.5 (− 4.4 to 7.4), and 0.4 (− 4.0 to 4.8) breaths per minute, respectively. Clinical decisions evaluated using CEG analyses were correct 98.1% of the time for the microwave Doppler sensor, which was similar to the performance of the other devices. Conclusion The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low. Trial registration number : UMIN000038900, February 1, 2020.
- Open Access
- 13 September 2023
- Published by Elsevier in Burns Open
- Vol. 7 (4) , 139-145
Clinical features and prognosis of toxic epidermal necrolysis requiring intensive care: A retrospective descriptive single-center study
- 13 September 2023
- Published by Elsevier in Burns Open
- Vol. 7 (4) , 139-145
Open AccessClinical features and prognosis of toxic epidermal necrolysis requiring intensive care: A retrospective descriptive single-center study
- Open Access
- 30 May 2023
- Published by Springer Nature in Journal of Intensive Care
- Vol. 11 (1) , 25
Stomach position evaluated using computed tomography is related to successful post-pyloric enteral feeding tube placement in critically ill patients: a retrospective observational study
Background: Post-pyloric enteral feeding reduces respiratory complications and shortens the duration of mechanical ventilation. Blind placement of post-pyloric enteral feeding tubes (EFT) in patients with critical illnesses is often the first-line method because endoscopy or fluoroscopy cannot be easily performed at bedside; however, difficult placements regularly occur. We reported an association between the stomach position caudal to spinal level L1–L2, evaluated by abdominal radiographs after placement, and difficult placement; however, this method could not indicate difficulty before EFT placement. The aim of our study was to evaluate the association between stomach position, estimated using computed tomography (CT) images taken before the blind placement of the post-pyloric EFT, and the difficulty of EFT placement. Methods: Data from patients aged ≥ 20 years who underwent post-pyloric EFT in our intensive care unit were obtained retrospectively. Logistic regression analysis was used to evaluate the association between successful initial EFT placement and explanatory variables, including stomach position estimated by CT. Two cut-off values were used: caudal to L1–L2 based on a previous study and the best cut-off value calculated by the receiver operating characteristic curve. Variable selection was performed backward stepwise using Akaike's Information Criterion. Results: Of the total of 453 patients who were enrolled, the success rate of the initial EFT placement was 43.5%. The adjusted odds ratio for successful initial EFT placement of the stomach position caudal to L1–L2 was 0.61 (95% confidence interval: 0.41–1.07). Logistic regression analysis, including the stomach position caudal to L2–L3, calculated as the best cut-off value, indicated that stomach position was an independent factor for failure of initial EFT placement (adjusted odds ratio, 0.55; 95% confidence interval: 0.33–0.91). Conclusions: Stomach position evaluated using CT images was associated with successful initial post-pyloric EFT placement. The best cut-off value of the greater curvature of the stomach to predict the success or failure of the first attempt was spinal level L2–L3. Trial registration University Hospital Medical Information Network Clinical Trials Registry (UMIN000046986; February 28, 2022). https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000052151
- 30 May 2023
- Published by Springer Nature in Journal of Intensive Care
- Vol. 11 (1) , 25
Open AccessStomach position evaluated using computed tomography is related to successful post-pyloric enteral feeding tube placement in critically ill patients: a retrospective observational study
Background: Post-pyloric enteral feeding reduces respiratory complications and shortens the duration of mechanical ventilation. Blind placement of post-pyloric enteral feeding tubes (EFT) in patients with critical illnesses is often the first-line method because endoscopy or fluoroscopy cannot be easily performed at bedside; however, difficult placements regularly occur. We reported an association between the stomach position caudal to spinal level L1–L2, evaluated by abdominal radiographs after placement, and difficult placement; however, this method could not indicate difficulty before EFT placement. The aim of our study was to evaluate the association between stomach position, estimated using computed tomography (CT) images taken before the blind placement of the post-pyloric EFT, and the difficulty of EFT placement. Methods: Data from patients aged ≥ 20 years who underwent post-pyloric EFT in our intensive care unit were obtained retrospectively. Logistic regression analysis was used to evaluate the association between successful initial EFT placement and explanatory variables, including stomach position estimated by CT. Two cut-off values were used: caudal to L1–L2 based on a previous study and the best cut-off value calculated by the receiver operating characteristic curve. Variable selection was performed backward stepwise using Akaike's Information Criterion. Results: Of the total of 453 patients who were enrolled, the success rate of the initial EFT placement was 43.5%. The adjusted odds ratio for successful initial EFT placement of the stomach position caudal to L1–L2 was 0.61 (95% confidence interval: 0.41–1.07). Logistic regression analysis, including the stomach position caudal to L2–L3, calculated as the best cut-off value, indicated that stomach position was an independent factor for failure of initial EFT placement (adjusted odds ratio, 0.55; 95% confidence interval: 0.33–0.91). Conclusions: Stomach position evaluated using CT images was associated with successful initial post-pyloric EFT placement. The best cut-off value of the greater curvature of the stomach to predict the success or failure of the first attempt was spinal level L2–L3. Trial registration University Hospital Medical Information Network Clinical Trials Registry (UMIN000046986; February 28, 2022). https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000052151
- Open Access
- 30 September 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (9) , e0275451
Hypotension after general anesthesia induction using remimazolam in geriatric patients: Protocol for a double-blind randomized controlled trial
Introduction: In geriatric patients, hypotension is often reported after general anesthesia induction using propofol. Remimazolam is a novel short-acting sedative. However, the incidence of hypotension after general anesthesia induction using remimazolam in geriatric patients remains unclear. This study aims to compare the incidence of hypotension associated with remimazolam and propofol in patients aged ≥80 years. Methods: This single-center, double-blind, randomized, two-arm parallel group, standard treatment-controlled, interventional clinical trial will include 90 patients aged ≥80 years undergoing elective surgery under general anesthesia who will be randomized to receive remimazolam or propofol for induction. The primary outcome is the incidence of hypotension after general anesthesia induction, occurring between the start of drug administration and 3 min after intubation. We define hypotension as mean blood pressure t test, and Mann–Whitney U test, as appropriate. Logistic regression analysis will be performed to explore the factors associated with the incidence of hypotension after anesthesia induction. Discussion: Our trial will determine the efficacy of remimazolam in preventing hypotension and provide evidence on the usefulness of remimazolam for ensuring hemodynamic stability during general anesthesia induction in geriatric patients. Trial registration: The study has been registered with UMIN Clinical Trials Registry (UMIN000042587), on June 30, 2021.
- 30 September 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (9) , e0275451
Open AccessHypotension after general anesthesia induction using remimazolam in geriatric patients: Protocol for a double-blind randomized controlled trial
Introduction: In geriatric patients, hypotension is often reported after general anesthesia induction using propofol. Remimazolam is a novel short-acting sedative. However, the incidence of hypotension after general anesthesia induction using remimazolam in geriatric patients remains unclear. This study aims to compare the incidence of hypotension associated with remimazolam and propofol in patients aged ≥80 years. Methods: This single-center, double-blind, randomized, two-arm parallel group, standard treatment-controlled, interventional clinical trial will include 90 patients aged ≥80 years undergoing elective surgery under general anesthesia who will be randomized to receive remimazolam or propofol for induction. The primary outcome is the incidence of hypotension after general anesthesia induction, occurring between the start of drug administration and 3 min after intubation. We define hypotension as mean blood pressure t test, and Mann–Whitney U test, as appropriate. Logistic regression analysis will be performed to explore the factors associated with the incidence of hypotension after anesthesia induction. Discussion: Our trial will determine the efficacy of remimazolam in preventing hypotension and provide evidence on the usefulness of remimazolam for ensuring hemodynamic stability during general anesthesia induction in geriatric patients. Trial registration: The study has been registered with UMIN Clinical Trials Registry (UMIN000042587), on June 30, 2021.
- Open Access
- 7 October 2021
- Published by Springer Nature in Journal of Intensive Care
- Vol. 9 (1) , 1-9
Multivariate analysis of factors associated with first-pass success in blind placement of a post-pyloric feeding tube: a retrospective study
Background: Trans-jejunal nutrition via a post-pyloric enteral feeding tube has a low risk of aspiration or reflux; however, placement of the tube using the blind method can be difficult. Assistive devices, such as fluoroscopy or endoscopy, are useful but may not be suitable for patients with hemodynamic instability or severe respiratory failure. The aim of this study was to explore factors associated with first-pass success in the blind placement of post-pyloric enteral feeding tubes in critically ill patients. Methods: Data were obtained retrospectively from the medical records of adult patients who had a post-pyloric enteral feeding tube placed in the intensive care unit between January 1, 2012, and December 31, 2018. Logistic regression analysis was performed to assess the association between first-pass success and the independent variables. For logistic regression analysis, the following 13 variables were defined as independent variables: age, sex, height, fluid balance from baseline, use of sedatives, body position during the procedure, use of cardiac assist devices, use of prokinetic agents, presence or absence of intestinal peristalsis, postoperative cardiovascular surgery, use of renal replacement therapy, serum albumin levels, and position of the greater curvature of the stomach in relation to spinal levels L1 − L2. Results: Data obtained from 442 patients were analyzed. The first-pass success rate was 42.8% (n = 189). Logistic regression analysis demonstrated that the position of the greater curvature of the stomach cephalad to L1 − L2 was only associated with successful placement (odds ratio for first-pass success, 0.62; 95% confidence interval: 0.40 − 0.95). Conclusions: In critically ill patients, the position of the greater curvature of the stomach caudal to L1 − L2 may be associated with a lower first-pass success rate of the blind method for post-pyloric enteral feeding tube placement. Further studies are needed to verify our results because the position of the stomach was estimated by radiographs after enteral feeding tube placement. Trial registration: University Hospital Medical Information Network Clinical Trials Registry (UMIN000036549; April 20, 2019).
- 7 October 2021
- Published by Springer Nature in Journal of Intensive Care
- Vol. 9 (1) , 1-9
Open AccessMultivariate analysis of factors associated with first-pass success in blind placement of a post-pyloric feeding tube: a retrospective study
Background: Trans-jejunal nutrition via a post-pyloric enteral feeding tube has a low risk of aspiration or reflux; however, placement of the tube using the blind method can be difficult. Assistive devices, such as fluoroscopy or endoscopy, are useful but may not be suitable for patients with hemodynamic instability or severe respiratory failure. The aim of this study was to explore factors associated with first-pass success in the blind placement of post-pyloric enteral feeding tubes in critically ill patients. Methods: Data were obtained retrospectively from the medical records of adult patients who had a post-pyloric enteral feeding tube placed in the intensive care unit between January 1, 2012, and December 31, 2018. Logistic regression analysis was performed to assess the association between first-pass success and the independent variables. For logistic regression analysis, the following 13 variables were defined as independent variables: age, sex, height, fluid balance from baseline, use of sedatives, body position during the procedure, use of cardiac assist devices, use of prokinetic agents, presence or absence of intestinal peristalsis, postoperative cardiovascular surgery, use of renal replacement therapy, serum albumin levels, and position of the greater curvature of the stomach in relation to spinal levels L1 − L2. Results: Data obtained from 442 patients were analyzed. The first-pass success rate was 42.8% (n = 189). Logistic regression analysis demonstrated that the position of the greater curvature of the stomach cephalad to L1 − L2 was only associated with successful placement (odds ratio for first-pass success, 0.62; 95% confidence interval: 0.40 − 0.95). Conclusions: In critically ill patients, the position of the greater curvature of the stomach caudal to L1 − L2 may be associated with a lower first-pass success rate of the blind method for post-pyloric enteral feeding tube placement. Further studies are needed to verify our results because the position of the stomach was estimated by radiographs after enteral feeding tube placement. Trial registration: University Hospital Medical Information Network Clinical Trials Registry (UMIN000036549; April 20, 2019).
- 30 June 2021
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 36 (1) , 71-79
Evaluation of respiratory rate monitoring using a microwave Doppler sensor mounted on the ceiling of an intensive care unit: a prospective observational study
Continuous monitoring of the respiratory rate is crucial in an acute care setting. Contact respiratory monitoring modalities such as capnography and thoracic impedance pneumography are prone to artifacts, causing false alarms. Moreover, their cables can restrict patient behavior or interrupt patient care. A microwave Doppler sensor is a novel non-contact continuous respiratory rate monitor. We compared respiratory rate measurements performed with a microwave Doppler sensor mounted on the ceiling of an intensive care unit with those obtained by conventional methods in conscious and spontaneously breathing patients. Participants’ respiratory rate was simultaneously measured by visual counting of chest wall movements for 60 s; a microwave Doppler sensor; capnography, using an oxygen mask; and thoracic impedance pneumography, using electrocardiogram electrodes. Bland–Altman analysis for repeated measures was performed to calculate bias and 95% limits of agreement between the respiratory rate measured by visual counting (reference) and that measured by each of the other methods. Among 52 participants, there were 336 (microwave Doppler sensor), 275 (capnography), and 336 (thoracic impedance pneumography) paired respiratory rate data points. Bias (95% limits of agreement) estimates were as follows: microwave Doppler sensor, 0.3 (− 6.1 to 6.8) breaths per minute (bpm); capnography, − 1.3 (− 8.6 to 6.0) bpm; and thoracic impedance pneumography, 0.1 (− 4.4 to 4.7) bpm. Compared to visual counting, the microwave Doppler sensor showed small bias; however, the limits of agreement were similar to those observed in other conventional methods. Our monitor and the conventional ones are not interchangeable with visual counting. Trial registration number: UMIN000032021, March/30/2018
- 30 June 2021
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 36 (1) , 71-79
Evaluation of respiratory rate monitoring using a microwave Doppler sensor mounted on the ceiling of an intensive care unit: a prospective observational study
Continuous monitoring of the respiratory rate is crucial in an acute care setting. Contact respiratory monitoring modalities such as capnography and thoracic impedance pneumography are prone to artifacts, causing false alarms. Moreover, their cables can restrict patient behavior or interrupt patient care. A microwave Doppler sensor is a novel non-contact continuous respiratory rate monitor. We compared respiratory rate measurements performed with a microwave Doppler sensor mounted on the ceiling of an intensive care unit with those obtained by conventional methods in conscious and spontaneously breathing patients. Participants’ respiratory rate was simultaneously measured by visual counting of chest wall movements for 60 s; a microwave Doppler sensor; capnography, using an oxygen mask; and thoracic impedance pneumography, using electrocardiogram electrodes. Bland–Altman analysis for repeated measures was performed to calculate bias and 95% limits of agreement between the respiratory rate measured by visual counting (reference) and that measured by each of the other methods. Among 52 participants, there were 336 (microwave Doppler sensor), 275 (capnography), and 336 (thoracic impedance pneumography) paired respiratory rate data points. Bias (95% limits of agreement) estimates were as follows: microwave Doppler sensor, 0.3 (− 6.1 to 6.8) breaths per minute (bpm); capnography, − 1.3 (− 8.6 to 6.0) bpm; and thoracic impedance pneumography, 0.1 (− 4.4 to 4.7) bpm. Compared to visual counting, the microwave Doppler sensor showed small bias; however, the limits of agreement were similar to those observed in other conventional methods. Our monitor and the conventional ones are not interchangeable with visual counting. Trial registration number: UMIN000032021, March/30/2018
- Open Access
- 14 February 2020
- Published by Springer Nature in Journal of Intensive Care
- Vol. 8 (1) , 1-3
A question is “what are the optimal targets for anticoagulant therapies?”
A high mortality rate is found among septic patients with disseminated intravascular coagulation (DIC). Anticoagulants have been used for treating septic DIC especially in Japanese clinical settings; however, their effectiveness is quite controversial across studies. According to several randomized controlled trials and meta-analyses, antithrombin and recombinant thrombomodulin had no therapeutic benefit in the treatment of sepsis. However, the majority of the previous research did not discuss “septic DIC” but simply “sepsis”, and some reviews showed that anticoagulants were benefit only in septic DIC. Although immunothrombosis plays an important role in early host defense, it can lead to DIC and organ failure if dysregulated. Therefore, we advocate anticoagulant therapies might have beneficial effects, but research on optimal patient selection is currently lacking.
- 14 February 2020
- Published by Springer Nature in Journal of Intensive Care
- Vol. 8 (1) , 1-3
Open AccessA question is “what are the optimal targets for anticoagulant therapies?”
A high mortality rate is found among septic patients with disseminated intravascular coagulation (DIC). Anticoagulants have been used for treating septic DIC especially in Japanese clinical settings; however, their effectiveness is quite controversial across studies. According to several randomized controlled trials and meta-analyses, antithrombin and recombinant thrombomodulin had no therapeutic benefit in the treatment of sepsis. However, the majority of the previous research did not discuss “septic DIC” but simply “sepsis”, and some reviews showed that anticoagulants were benefit only in septic DIC. Although immunothrombosis plays an important role in early host defense, it can lead to DIC and organ failure if dysregulated. Therefore, we advocate anticoagulant therapies might have beneficial effects, but research on optimal patient selection is currently lacking.