ECEdward N. Crawford

Edward N. Crawford

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Edward N. Crawford has a total of 54 co-authors. Here are the top co-authors by number of shared publications:

  • Gary D. Housley

    Translational Neuroscience Facility Department of Physiology School of Biomedical Sciences Graduate School of Biomedical Engineering Tyree Institute for Health Engineering (IHealthE) UNSW Sydney NSW 2052 Australia

    6 shared publications
  • Nigel Hamilton Lovell

    UNSW Sydney

    5 shared publications
  • Amr Al Abed

    Graduate School of Biomedical Engineering, UNSW, Sydney, NSW, Australia

    4 shared publications
  • Georg von Jonquieres

    Translational Neuroscience Facility Department of Physiology School of Biomedical Sciences Graduate School of Biomedical Engineering Tyree Institute for Health Engineering (IHealthE) UNSW Sydney NSW 2052 Australia

    4 shared publications
  • Jeremy L. Pinyon

    Translational Neuroscience Facility Department of Physiology School of Biomedical Sciences Graduate School of Biomedical Engineering Tyree Institute for Health Engineering (IHealthE) UNSW Sydney NSW 2052 Australia

    4 shared publications
  • Matthias Klugmann

    Translational Neuroscience Facility Department of Physiology School of Biomedical Sciences Graduate School of Biomedical Engineering Tyree Institute for Health Engineering (IHealthE) UNSW Sydney NSW 2052 Australia

    3 shared publications

Latest Publications

  • Open Access

    Engineering of a wireless single capacitive discharge conductivity-clamped gene electrotransfer probe for naked nucleic acid therapeutics

    by Keng-Yin Lai, Stephen L. Mow, Mathumathi Manoharan, Anastasia Thiessen, Georg von Jonquieres, Jeremy L. Pinyon, Edward N. Crawford, Gary D. Housley, Amr Al Abed, Nigel H. Lovell

    Pulsed electric field gene electrotransfer addresses the need for safe, directed “vector-free” delivery of DNA/mRNA therapeutics in deep tissue targets. We report the development of a disposable needle-type “electro-lens” probe for precision delivery of DNA/mRNA to tissues via translocation of nucleic acids into cells using focused single-pulse electric fields. We developed and manufactured a novel ganged linear bionic electrode array enhanced by incorporating integrated microfluidics to deliver naked DNA expression cassettes in a low-conductivity carrier (“conductivity-clamping,” CC). This system was packaged in a disposable wireless probe for single capacitive discharge conductivity-clamped gene electrotransfer (SCD-CC-GET), powered by an integrated capacitor with automated discharge mechanism. The electrode array was achieved by laser-etching parylene-insulated concentric stainless steel needles, with the lensing effect of the electric field tuned by varying the separation between elongated conductive elements. Our novel SCD-CC-GET probe is fully wireless and standalone, featuring integrated fluidics with minimal dead space, and an automated discharge mechanism. The probe was validated in vitro through HEK293 cell transfection of green fluorescent protein reporter plasmid DNA, where CC significantly expanded the transfection zone by up to 3×. In vivo proof of concept for deep tissue gene delivery by SCD-CC-GET was achieved in the mouse gastrocnemius muscle with long-term expression of mCherry reporter DNA. Our technology for GET is compact, low-cost, and fully wireless, with only a single point of insertion, and produces maximal electric fields at the target zone, allowing for more efficient gene therapies with minimal charge transfer, in a fine needle profile.

  • Open Access

    Electrotactile frequency perception over multiple stimulation sites does not use a winner‐takes‐all mechanism

    by Alwin So, Hiroyuki Kajimoto, Edward N. Crawford, Richard M. Vickery, Ingvars Birznieks

    It is not known how the brain extracts vibrotactile stimulus frequency from the peripheral afferent population whose afferents exhibit a wide range of response patterns to a pure frequency stimulus, including afferents which do not respond to every vibration cycle of the stimulus and thus have lower firing rates. One hypothesis is a winner‐takes‐all mechanism based on the peripheral afferents with the highest or most regular firing rate, which discounts those firing at lower rates. We used a high‐resolution fingertip electrode array and activated some electrodes at 40 Hz and others at 20 Hz to investigate integration of tactile afferent population input signalling frequency information. Participants ( n = 12) gave ratings of frequency for these mixed‐frequency stimuli against a standard pure frequency. Participants reported perceiving a unified holistic frequency for the mixed‐frequency stimuli. This perceived frequency did not match any inter‐pulse intervals in the stimulus; instead, it appeared to represent a weighted measure of the two presented frequencies. Our findings add to previous reports of frequency averaging for multiple mechanical stimuli, which suggest that activity across the whole population of activated afferents determines frequency perception. That frequency perception may be based on weighted averaging across all afferents has implications for applications of electrical nerve stimulation for sensory feedback. image Key points: Vibration of the skin causes a wide range of response patterns in tactile afferents of the responding neural population. It has been proposed that a winner‐takes‐all mechanism favouring afferents with the highest or most regular firing rate enables the nervous system to extract the vibration frequency of the applied stimulus. We stimulated fingertip tactile afferents via an electrical array, with a variable proportion of electrodes activated at 40 Hz and the rest at 20 Hz, and asked participants to make judgements about the stimulus frequency. The perceived frequency was not locked to the highest presented frequency, but instead increased gradually in all participants as the proportion of electrodes delivering 40 Hz increased. This shows that a winner‐takes‐all mechanism does not operate; instead, the entire population of responding afferents contribute with some weighting factor to vibration frequency perception.


  • Open Access

    Computational modeling for precision targeting of conductivity-clamped gene electrotransfer within the striatum of the human brain

    by Keng-Yin Lai, Stephen L Mow, Mathumathi Manoharan, Lily J Pearson, Georg von Jonquieres, Jeremy L Pinyon, Edward N Crawford, Frederic von Wegner, Gary D Housley, Nigel H Lovell, et al.

    Objective. Bionic array-directed gene electrotransfer (GET) is an emerging technology for precision ‘vector-free’ transfection of naked delivery of nucleic acid (DNA/mRNA) to target tissues, utilizing electro-lens focusing of a pulsed electric field. The efficiency of this translocation of naked polyanionic macromolecular nucleic acids (NAs) to the plasma membrane is greatly enhanced by reducing tissue conductivity (‘conductivity-clamping’) CC by the displacement of extracellular ionic species using a low-conductivity carrier (sucrose). This increases the electric field strength, minimizes the charge transfer, and significantly enhances gene transfection. Approach. T1 and diffusion weighted imaging clinical magnetic resonance imaging data, along with spatiotemporal mapping of sucrose-mediated ion CC in the guinea pig brain, enabled computational modeling of electric field manipulation. The scalable model was informed by in vitro single capacitive discharge GET of green fluorescent protein reporter plasmid DNA in HEK293 cells, and in vivo CC in the guinea pig brain striatum where spatiotemporal mapping of local tissue conductivity reduction was recorded proximal to the infusion site and at distance. Main results. These data enabled the prediction of the shape and volume of the transfection zone with respect to the GET pulse current amplitude, electrode orientation, and current steering between the electrodes. The predicted suprathreshold brain tissue volume for GET in the striatal region of the human brain increases by 130% with CC. Significance. This experimentally refined model was translated into the human brain to enable the integration of precise 3D targeting of NA therapeutics for directing gene-based treatments, such as the striatal basal ganglia target for Parkinson’s disease.


  • Open Access

    Vector‐Free Deep Tissue Targeting of DNA/RNA Therapeutics via Single Capacitive Discharge Conductivity‐Clamped Gene Electrotransfer

    by Jeremy L. Pinyon, Georg von Jonquieres, Stephen L. Mow, Amr Al Abed, Keng‐Yin Lai, Mathumathi Manoharan, Edward N. Crawford, Stanley H. Xue, Sarah Smith‐Moore, Lisa J. Caproni, et al.

    Viral vector and lipid nanoparticle based gene delivery have limitations around spatiotemporal control, transgene packaging size, and vector immune reactivity, compromising translation of nucleic acid (NA) therapeutics. In the emerging field of DNA and particularly RNA‐based gene therapies, vector‐free delivery platforms are identified as a key unmet need. Here, this work addresses these challenges through gene electrotransfer (GET) of “naked” polyanionic DNA/mRNA using a single needle form‐factor which supports “electro‐lens” based compression of the local electric field, and local control of tissue conductivity, enabling single capacitive discharge minimal charge gene delivery. Proof‐of‐concept studies for “single capacitive discharge conductivity‐clamped gene electrotransfer” (SCD‐CC‐GET) deep tissue delivery of naked DNA and mRNA in the mouse hindlimb skeletal muscle achieve stable (>18 month) expression of luciferase reporter synthetic DNA, and mRNA encoding the reporter yield rapid onset (<3 h) high transient expression for several weeks. Delivery of DNAs encoding secreted alkaline phosphatase and Cal/09 influenza virus hemagglutinin antigen generate high systemic circulating recombinant protein levels and antibody titres. The findings support adoption of SCD‐CC‐GET for vaccines and immunotherapies, and extend the utility of this technology to meet the demand for efficient vector‐free, precision, deep tissue delivery of NA therapeutics.


  • Open Access

    Gene Electrotransfer via Conductivity‐Clamped Electric Field Focusing Pivots Sensori‐Motor DNA Therapeutics: “A Spoonful of Sugar Helps the Medicine Go Down”

    by Jeremy L. Pinyon, Georg von Jonquieres, Edward N. Crawford, Amr Al Abed, John M. Power, Matthias Klugmann, Cherylea J. Browne, David M. Housley, Andrew K. Wise, James B. Fallon, et al.

    Viral vectors and lipofection‐based gene therapies have dispersion‐dependent transduction/transfection profiles that thwart precise targeting. The study describes the development of focused close‐field gene electrotransfer (GET) technology, refining spatial control of gene expression. Integration of fluidics for precise delivery of “naked” plasmid deoxyribonucleic acid (DNA) in sucrose carrier within the focused electric field enables negative biasing of near‐field conductivity (“conductivity‐clamping”–CC), increasing the efficiency of plasma membrane molecular translocation. This enables titratable gene delivery with unprecedently low charge transfer. The clinic‐ready bionics‐derived CC‐GET device achieved neurotrophin‐encoding miniplasmid DNA delivery to the cochlea to promote auditory nerve regeneration; validated in deafened guinea pig and cat models, leading to improved central auditory tuning with bionics‐based hearing. The performance of CC‐GET is evaluated in the brain, an organ problematic for pulsed electric field‐based plasmid DNA delivery, due to high required currents causing Joule‐heating and damaging electroporation. Here CC‐GET enables safe precision targeting of gene expression. In the guinea pig, reporter expression is enabled in physiologically critical brainstem regions, and in the striatum (globus pallidus region) delivery of a red‐shifted channelrhodopsin and a genetically‐encoded Ca2+ sensor, achieved photoactivated neuromodulation relevant to the treatment of Parkinson's Disease and other focal brain disorders.


  • Neurotrophin gene augmentation by electrotransfer to improve cochlear implant hearing outcomes

    by Jeremy L. Pinyon, Georg von Jonquieres, Edward N. Crawford, Mayryl Duxbury, Amr Al Abed, Nigel H. Lovell, Matthias Klugmann, Andrew K. Wise, James B. Fallon, Robert K. Shepherd, et al.


  • Cochlear Implant Close-Field Electroporation

    by Gary D. Housley, Cherylea J. Browne, Edward N. Crawford, Matthias Klugmann, Nigel H. Lovell, Jeremy L. Pinyon