Chunhai Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chunhai Li has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Haipeng Jia
Department of Radiology, Qilu Hospital of Shandong University, Jinan 250012, China
4 shared publications - Hong Meng
Department of Radiology, Qilu Hospital of Shandong University, Jinan, China
4 shared publications - Bo Liu
Department of Radiology, Qilu Hospital of Shandong University, Jinan, China
3 shared publications Fengmin Pan
Department of Radiology, Qilu Hospital of Shandong University, Jinan, Shandong Province, PR China
2 shared publicationsBin Liu
1 shared publicationBo Liu
Department of Radiology, Qilu Hospital of Shandong University, Jinan, Shandong Province, PR China
1 shared publication
Latest Publications
- 24 January 2020
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (9) , 1249-1257
Diagnostic value of 3.0 T cardiac MRI in children with suspected myocarditis: multi-parameter analysis for the evaluation of acute and chronic myocarditis
Cardiac magnetic resonance (CMR) is an established tool for detection of myocarditis. However, no comprehensive data for CMR based on the “Lake Louise” criteria in pediatric myocarditis exists to date. To evaluate the value of multi-parameter CMR in children with suspected acute (AMC) and chronic myocarditis (CMC). We examined 73 pediatric patients with clinically suspected AMC (n = 25) and CMC (n = 48). We compared them to 17 controls. All individuals underwent CMR, including function analyses, T2 ratio, early gadolinium enhancement ratio (EGEr), and late gadolinium enhancement (LGE). In AMC, 19 (76%) patients were abnormal in any two of three parameters (T2 ratio, EGEr, and LGE). There was a significant difference between AMC and controls in LVEF (51.2% vs. 61.3%), mass (130.2 ± 14.0 vs. 120.5 ± 13.9 g), T2 ratio (1.96 ± 0.2 vs. 1.69 ± 0.13), and EGEr (4.1 ± 0.27 vs. 3.4 ± 0.39) (P < 0.05). In CMC, 26 (54.1%) patients were abnormal in any two of three parameters. There was no significant difference between CMC and controls in LVEF and mass, but there was a statistical difference in T2 ratio (1.88 ± 0.18 vs. 1.69 ± 0.13) and in EGEr (3.93 ± 0.22 vs. 3.4 ± 0.39) (P < 0.05). There was an increase in LVEF while both T2 ratio and EGEr significantly decreased (P < 0.05) during follow-up of acute fulminant myocarditis. Comprehensive CMR may serve as a powerful tool in children with suspected AMC. CMR in assessment of CMC may be valuable, but it is not satisfactory.
- 24 January 2020
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (9) , 1249-1257
Diagnostic value of 3.0 T cardiac MRI in children with suspected myocarditis: multi-parameter analysis for the evaluation of acute and chronic myocarditis
Cardiac magnetic resonance (CMR) is an established tool for detection of myocarditis. However, no comprehensive data for CMR based on the “Lake Louise” criteria in pediatric myocarditis exists to date. To evaluate the value of multi-parameter CMR in children with suspected acute (AMC) and chronic myocarditis (CMC). We examined 73 pediatric patients with clinically suspected AMC (n = 25) and CMC (n = 48). We compared them to 17 controls. All individuals underwent CMR, including function analyses, T2 ratio, early gadolinium enhancement ratio (EGEr), and late gadolinium enhancement (LGE). In AMC, 19 (76%) patients were abnormal in any two of three parameters (T2 ratio, EGEr, and LGE). There was a significant difference between AMC and controls in LVEF (51.2% vs. 61.3%), mass (130.2 ± 14.0 vs. 120.5 ± 13.9 g), T2 ratio (1.96 ± 0.2 vs. 1.69 ± 0.13), and EGEr (4.1 ± 0.27 vs. 3.4 ± 0.39) (P < 0.05). In CMC, 26 (54.1%) patients were abnormal in any two of three parameters. There was no significant difference between CMC and controls in LVEF and mass, but there was a statistical difference in T2 ratio (1.88 ± 0.18 vs. 1.69 ± 0.13) and in EGEr (3.93 ± 0.22 vs. 3.4 ± 0.39) (P < 0.05). There was an increase in LVEF while both T2 ratio and EGEr significantly decreased (P < 0.05) during follow-up of acute fulminant myocarditis. Comprehensive CMR may serve as a powerful tool in children with suspected AMC. CMR in assessment of CMC may be valuable, but it is not satisfactory.
- Open Access
- 10 July 2019
- Published by Wiley in Thoracic Cancer
- Vol. 10 (8) , 1710-1716
Efficacy and safety of artificial pneumothorax with position adjustment for CT‐guided percutaneous transthoracic microwave ablation of small subpleural lung tumors
Background To evaluate the efficacy and safety of artificial pneumothorax with position adjustment for computed tomograpy (CT)‐guided percutaneous transthoracic microwave ablation (MWA) of small subpleural lung tumors. Methods Fifty‐six patients with small subpleural lung tumors (< 3.0 cm) entered the study and underwent CT‐guided MWA with (group I: 24 patients with 24 tumors) or without (group II: 32 patients with 34 tumors) the support of artificial pneumothorax. Follow‐up contrast‐enhanced CT scans were reviewed. Pain VAS (visual analog scale) scores at, during, and after ablation were compared between the two groups. Technical success, technique efficacy, local tumor control and complications were compared. Results Creation of the artificial pneumothorax was achieved for 24/24 (100%) in group I and no complication related to the procedure was observed. Technical success of MWA was achieved for all 58 tumors. Primary efficacy of MWA was achieved in 23 of 24 tumors (95.8%) treated in group I, and 32 of 34 tumors (94.1%) treated in group II (P = 0.771). The 12‐month local tumor control was achieved in 87.5% (21/24) in group I compared with 88.2% (30/34) in group II (P = 0.833). Pain VAS scores in group I were significantly decreased after the pneumothorax induction at, during, and after ablation compared with group II (P < 0.05). There was no significant difference in MWA‐related complications (P > 0.05). Conclusion Artificial pneumothorax with position adjustment for CT‐guided MWA is effective and may be safely applied to small subpleural lung tumors. Artificial pneumothorax is a reliable therapy for pain relief.
- 10 July 2019
- Published by Wiley in Thoracic Cancer
- Vol. 10 (8) , 1710-1716
Open AccessEfficacy and safety of artificial pneumothorax with position adjustment for CT‐guided percutaneous transthoracic microwave ablation of small subpleural lung tumors
Background To evaluate the efficacy and safety of artificial pneumothorax with position adjustment for computed tomograpy (CT)‐guided percutaneous transthoracic microwave ablation (MWA) of small subpleural lung tumors. Methods Fifty‐six patients with small subpleural lung tumors (< 3.0 cm) entered the study and underwent CT‐guided MWA with (group I: 24 patients with 24 tumors) or without (group II: 32 patients with 34 tumors) the support of artificial pneumothorax. Follow‐up contrast‐enhanced CT scans were reviewed. Pain VAS (visual analog scale) scores at, during, and after ablation were compared between the two groups. Technical success, technique efficacy, local tumor control and complications were compared. Results Creation of the artificial pneumothorax was achieved for 24/24 (100%) in group I and no complication related to the procedure was observed. Technical success of MWA was achieved for all 58 tumors. Primary efficacy of MWA was achieved in 23 of 24 tumors (95.8%) treated in group I, and 32 of 34 tumors (94.1%) treated in group II (P = 0.771). The 12‐month local tumor control was achieved in 87.5% (21/24) in group I compared with 88.2% (30/34) in group II (P = 0.833). Pain VAS scores in group I were significantly decreased after the pneumothorax induction at, during, and after ablation compared with group II (P < 0.05). There was no significant difference in MWA‐related complications (P > 0.05). Conclusion Artificial pneumothorax with position adjustment for CT‐guided MWA is effective and may be safely applied to small subpleural lung tumors. Artificial pneumothorax is a reliable therapy for pain relief.
- 1 January 2019
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 30 (1) , 95-102
Efficacy and Radiation Exposure of Ultra-Low-Dose Chest CT at 100 kVp with Tin Filtration in CT-Guided Percutaneous Core Needle Biopsy for Small Pulmonary Lesions Using a Third-Generation Dual-Source CT Scanner
- 1 January 2019
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 30 (1) , 95-102
Efficacy and Radiation Exposure of Ultra-Low-Dose Chest CT at 100 kVp with Tin Filtration in CT-Guided Percutaneous Core Needle Biopsy for Small Pulmonary Lesions Using a Third-Generation Dual-Source CT Scanner
- Open Access
- 26 July 2018
- Published by Wiley in Thoracic Cancer
- Vol. 9 (9) , 1145-1150
Computed tomography‐guided hook wire localization facilitates video‐assisted thoracoscopic surgery of pulmonary ground‐glass nodules
Background: This retrospectively study was conducted to assess the efficiency and safety of computed tomography (CT)‐guided hook wire localization of pulmonary ground‐glass nodules (GGNs) prior to video‐assisted thoracoscopic surgery (VATS).Methods: From 2015 to 2018, a total of 86 patients with 86 pulmonary GGNs underwent preoperative CT‐guided hook wire localization before VATS. The technical details and clinicopathological findings were analyzed.Results: All 86 pulmonary GGNs (25 pure GGNs and 61 part‐solid GGNs) were successfully located and resected. The mean diameter of the GGNs was 1.4 ± 0.4 cm (range 0.6–2.2) and the mean lesion distance to the pleural surface was 7.3 ± 4.3 mm (range 2–19). Complications of hook wire marking included asymptomatic minor pneumothorax in 21 patients (24%) and focal pulmonary hemorrhage in 18 (21%). The median hook wire localization time was 19.1 minutes (range 10–30) and the median VATS time was 49 minutes (range 28–89). Pathology revealed 72 precancerous lesions or primary lung adenocarcinomas, 5 metastatic tumors, and 9 benign lesions.Conclusions: Preoperative localization of small pulmonary GGNs using CT‐guided hook wire was efficient and safe prior to VATS resection.
- 26 July 2018
- Published by Wiley in Thoracic Cancer
- Vol. 9 (9) , 1145-1150
Open AccessComputed tomography‐guided hook wire localization facilitates video‐assisted thoracoscopic surgery of pulmonary ground‐glass nodules
Background: This retrospectively study was conducted to assess the efficiency and safety of computed tomography (CT)‐guided hook wire localization of pulmonary ground‐glass nodules (GGNs) prior to video‐assisted thoracoscopic surgery (VATS).Methods: From 2015 to 2018, a total of 86 patients with 86 pulmonary GGNs underwent preoperative CT‐guided hook wire localization before VATS. The technical details and clinicopathological findings were analyzed.Results: All 86 pulmonary GGNs (25 pure GGNs and 61 part‐solid GGNs) were successfully located and resected. The mean diameter of the GGNs was 1.4 ± 0.4 cm (range 0.6–2.2) and the mean lesion distance to the pleural surface was 7.3 ± 4.3 mm (range 2–19). Complications of hook wire marking included asymptomatic minor pneumothorax in 21 patients (24%) and focal pulmonary hemorrhage in 18 (21%). The median hook wire localization time was 19.1 minutes (range 10–30) and the median VATS time was 49 minutes (range 28–89). Pathology revealed 72 precancerous lesions or primary lung adenocarcinomas, 5 metastatic tumors, and 9 benign lesions.Conclusions: Preoperative localization of small pulmonary GGNs using CT‐guided hook wire was efficient and safe prior to VATS resection.
- 1 April 2011
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 113 (3) , 178-182
Transcatheter arterial chemoembolization versus systemic methotrexate for the management of cesarean scar pregnancy
Objective: To evaluate the effectiveness/safety of systemic methotrexate (MTX) treatment versus transcatheter arterial chemoembolization using different embolic agents for termination of cesarean scar pregnancy (CSP).Methods: Women with CSP were randomized to receive intravenous infusion of MTX (group 1, n = 13), or chemoembolization with MTX and either gelatin sponge (GS; group 2, n = 15) or polyvinyl alcohol (PVA; group 3, n = 16) particles. Uterine suction curettage followed all procedures. Bleeding volume, time until resolution of serum β‐hCG, and length of hospital stay were recorded as outcome endpoints.Results: Bleeding volume was smaller in groups 2 (mean ± SD, 73 ± 20 mL) and 3 (63 ± 22 mL) than in group 1 (952 ± 471 mL) (P < 0.001). Time until resolution of β‐hCG was shorter in groups 2 (29 ± 16 days) and 3 (30 ± 19 days) than in group 1 (57 ± 25 days) (P < 0.01). Length of hospital stay was shorter in groups 2 (13 ± 4 days) and 3 (12 ± 3 days) than in group 1 (36 ± 8 days) (P < 0.01).Conclusion: Transcatheter arterial chemoembolization was more effective than systemic MTX treatment for termination of CSP. Large cohort studies are warranted to compare effectiveness between PVA and GS particles.
- 1 April 2011
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 113 (3) , 178-182
Transcatheter arterial chemoembolization versus systemic methotrexate for the management of cesarean scar pregnancy
Objective: To evaluate the effectiveness/safety of systemic methotrexate (MTX) treatment versus transcatheter arterial chemoembolization using different embolic agents for termination of cesarean scar pregnancy (CSP).Methods: Women with CSP were randomized to receive intravenous infusion of MTX (group 1, n = 13), or chemoembolization with MTX and either gelatin sponge (GS; group 2, n = 15) or polyvinyl alcohol (PVA; group 3, n = 16) particles. Uterine suction curettage followed all procedures. Bleeding volume, time until resolution of serum β‐hCG, and length of hospital stay were recorded as outcome endpoints.Results: Bleeding volume was smaller in groups 2 (mean ± SD, 73 ± 20 mL) and 3 (63 ± 22 mL) than in group 1 (952 ± 471 mL) (P < 0.001). Time until resolution of β‐hCG was shorter in groups 2 (29 ± 16 days) and 3 (30 ± 19 days) than in group 1 (57 ± 25 days) (P < 0.01). Length of hospital stay was shorter in groups 2 (13 ± 4 days) and 3 (12 ± 3 days) than in group 1 (36 ± 8 days) (P < 0.01).Conclusion: Transcatheter arterial chemoembolization was more effective than systemic MTX treatment for termination of CSP. Large cohort studies are warranted to compare effectiveness between PVA and GS particles.