W. Denis Markiewicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
W. Denis Markiewicz has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hongyu Bai
National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
2 shared publications Iain Dixon
National High Magnetic Field Laboratory
2 shared publications- Iain R. Dixon
National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
2 shared publications - Andrey Vladimir Gavrilin
National High Magnetic Field Laboratory, Tallahassee, FL, USA
1 shared publication Brent Jarvis
National High Magnetic Field Laboratory
1 shared publicationC.A. Swenson
Tallahassee, FL, USA
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (7) , 075034
Control of turn-to-turn contact resistivity in no-insulation REBCO coils
No-insulation (NI) REBCO magnets with optimized contact resistivity feature short ramp times and low ramp losses while maintaining the advantages of NI coils with high engineering current density and tolerance for defects in the REBCO conductor. Control of the turn-to-turn contact resistivity ( ρ c ) is key to NI technology. ρ c must be sufficiently high to prevent a large transient current, which could result in high mechanical stress during magnet quenches. Meanwhile it must be lower than the quench propagation limit to avoid conductor burn-out during a quench. Therefore, it is critical to control ρ c within a suitable range of values which is usually coil specific. Previously, we discovered that ρ c between two REBCO tapes with a stainless steel interlayer decreases dramatically with contact pressure cycling by up to three orders of magnitude. This drastic change makes it impossible to design a suitable ρ c value for a stainless steel co-wound NI magnet. In this work, we first present methods for mitigating ρ c pressure cycling sensitivity. We found that by adding conductive fillers, such as conductive paste or epoxy, the ρ c load cycling sensitivity is largely mitigated. For dry-wound coils, ρ c load cycling sensitivity is mitigated by coating REBCO tape with a layer of 2–3 µ m of PbSn solder. In addition, ρ c can be controlled by oxidizing the stainless steel co-wind tape by heating stainless steel tapes at different temperatures in air. Using above methods, short sample tests showed that ρ c was controlled to prescribed values of 1000 and 5000 µ Ω-cm 2 and was not sensitive to contact pressure cycling up to 30 000 cycles at 4.2 K. The new ρ c control method was applied to a 6 double-pancake test coil which was tested at 4.2 K. The ρ c in this test coil was comparable with the short sample results. This demonstrated the ability of this new method to control ρ c in large coils. Moreover, we propose a method of measuring coil’s ρ c by the decay time of coil’s inductive voltage.
- 1 July 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (7) , 075034
Open AccessControl of turn-to-turn contact resistivity in no-insulation REBCO coils
No-insulation (NI) REBCO magnets with optimized contact resistivity feature short ramp times and low ramp losses while maintaining the advantages of NI coils with high engineering current density and tolerance for defects in the REBCO conductor. Control of the turn-to-turn contact resistivity ( ρ c ) is key to NI technology. ρ c must be sufficiently high to prevent a large transient current, which could result in high mechanical stress during magnet quenches. Meanwhile it must be lower than the quench propagation limit to avoid conductor burn-out during a quench. Therefore, it is critical to control ρ c within a suitable range of values which is usually coil specific. Previously, we discovered that ρ c between two REBCO tapes with a stainless steel interlayer decreases dramatically with contact pressure cycling by up to three orders of magnitude. This drastic change makes it impossible to design a suitable ρ c value for a stainless steel co-wound NI magnet. In this work, we first present methods for mitigating ρ c pressure cycling sensitivity. We found that by adding conductive fillers, such as conductive paste or epoxy, the ρ c load cycling sensitivity is largely mitigated. For dry-wound coils, ρ c load cycling sensitivity is mitigated by coating REBCO tape with a layer of 2–3 µ m of PbSn solder. In addition, ρ c can be controlled by oxidizing the stainless steel co-wind tape by heating stainless steel tapes at different temperatures in air. Using above methods, short sample tests showed that ρ c was controlled to prescribed values of 1000 and 5000 µ Ω-cm 2 and was not sensitive to contact pressure cycling up to 30 000 cycles at 4.2 K. The new ρ c control method was applied to a 6 double-pancake test coil which was tested at 4.2 K. The ρ c in this test coil was comparable with the short sample results. This demonstrated the ability of this new method to control ρ c in large coils. Moreover, we propose a method of measuring coil’s ρ c by the decay time of coil’s inductive voltage.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Screening Current Induced Stress/Strain Analysis of High Field REBCO Coils With Co-Winding or Over-Banding Reinforcement
Inclusion of screening current induced stress (SCIS) is becoming more commonplace in the design of ultra-high field magnets with REBCO tapes. It is desired to comprehensively manage tensile hoop stress, compressive hoop stress, and tilting angle caused by the SCIS. In this study, we have implemented effects of winding and cooldown processes to an already developed FEM model and analyzed the stress/strain behavior considering the SCIS on REBCO pancake coils in a 35 T LTS/HTS magnet with co-winding or over-banding reinforcement. Effects of thermal contraction and winding tension, and advantages/disadvantages of the co-winding or over-banding method are discussed.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Screening Current Induced Stress/Strain Analysis of High Field REBCO Coils With Co-Winding or Over-Banding Reinforcement
Inclusion of screening current induced stress (SCIS) is becoming more commonplace in the design of ultra-high field magnets with REBCO tapes. It is desired to comprehensively manage tensile hoop stress, compressive hoop stress, and tilting angle caused by the SCIS. In this study, we have implemented effects of winding and cooldown processes to an already developed FEM model and analyzed the stress/strain behavior considering the SCIS on REBCO pancake coils in a 35 T LTS/HTS magnet with co-winding or over-banding reinforcement. Effects of thermal contraction and winding tension, and advantages/disadvantages of the co-winding or over-banding method are discussed.
- 12 September 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (10) , 105010
Quench transient current and quench propagation limit in pancake wound REBCO coils as a function of contact resistance, critical current, and coil size
It is a general belief that no insulation (NI) coil technology is a path to very high field superconducting coils. Recent experience has shown that there are aspects of NI coil design that, if not addressed, can possibly lead to coil failures. One potential problem area is the large transient currents that are associated with quench propagation in NI coils. In an attempt to understand and possibly find ways to minimize the potential for damage from quench transients, a parameter study was undertaken to examine the factors that influence the magnitude of transient currents during quench in NI coils. The characteristics of the transient currents are first examined. A study is then made of a set of test coils, looking at quench propagation and the transient current magnitude as a function of contact resistance, critical current, and importantly coil size. For each coil size, it is found that as the contact resistance increases, the magnitude of quench transient currents is reduced until a condition where effective quench propagation ceases, called the quench propagation limit (QPL). As the QPL is approached, the amplitude of the transient current is decreased and may provide a regime where quench induced stress can be effectively contained in coil designs. As coil size increases, the value of contact resistance associated with the limit of quench propagation increases as well. At large coil sizes that will be characteristic of high field REBCO magnets, the QPL extends to truly large values of contact resistance compared to values observed between bare conductors. The use of methods such as resistive films on conductors and co-wind steel will be required to increase contact resistance. In recognition of this development, the use of high contact resistance achieved in this manner is appropriately called resistive insulation coil technology.
- 12 September 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (10) , 105010
Quench transient current and quench propagation limit in pancake wound REBCO coils as a function of contact resistance, critical current, and coil size
It is a general belief that no insulation (NI) coil technology is a path to very high field superconducting coils. Recent experience has shown that there are aspects of NI coil design that, if not addressed, can possibly lead to coil failures. One potential problem area is the large transient currents that are associated with quench propagation in NI coils. In an attempt to understand and possibly find ways to minimize the potential for damage from quench transients, a parameter study was undertaken to examine the factors that influence the magnitude of transient currents during quench in NI coils. The characteristics of the transient currents are first examined. A study is then made of a set of test coils, looking at quench propagation and the transient current magnitude as a function of contact resistance, critical current, and importantly coil size. For each coil size, it is found that as the contact resistance increases, the magnitude of quench transient currents is reduced until a condition where effective quench propagation ceases, called the quench propagation limit (QPL). As the QPL is approached, the amplitude of the transient current is decreased and may provide a regime where quench induced stress can be effectively contained in coil designs. As coil size increases, the value of contact resistance associated with the limit of quench propagation increases as well. At large coil sizes that will be characteristic of high field REBCO magnets, the QPL extends to truly large values of contact resistance compared to values observed between bare conductors. The use of methods such as resistive films on conductors and co-wind steel will be required to increase contact resistance. In recognition of this development, the use of high contact resistance achieved in this manner is appropriately called resistive insulation coil technology.
- 1 June 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 9 (2) , 2513-2516
Critical current and n-value of Nb/sub 3/Sn conductors for the wide bore 900 MHz NMR magnet
- 1 June 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 9 (2) , 2513-2516
Critical current and n-value of Nb/sub 3/Sn conductors for the wide bore 900 MHz NMR magnet
- 1 November 1997
- Published by Elsevier in Solid State Nuclear Magnetic Resonance
- Vol. 9 (1) , 73-76
1 GHz NMR spectroscopy: innovation in magnet technology
- 1 November 1997
- Published by Elsevier in Solid State Nuclear Magnetic Resonance
- Vol. 9 (1) , 73-76
1 GHz NMR spectroscopy: innovation in magnet technology