AJArshad Javed

Arshad Javed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arshad Javed has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Next-Gen Microfluidics: Reinforcement Learning Driven Droplet Size Precision System

    by Sameer Dubey, Badar Ali, Tvs Ramarao, Arshad Javed, Satish Dubey, Sanket Goel

    This study introduces a novel device with control, prediction and characterization feature designed for precise droplet size control using AI algorithms. The device employs a pressure by-pass valve to regulate the droplet size, ensuring droplet generation of the desired size. The system also employs an IOT-based droplet size training and prediction system, which predicts droplet sizes and builds a dataset based on the database uploaded by users. The device has a RaspberryPi-5 for AI code execution and image processing, an Arduino mini for in-built syringe pump control, and a digital microscope lens for droplet observation. The prediction system in the device helps the users to ascertain which droplet sizes can be achieved under particular microfluidic channel sizes, flow, viscosity and temperature conditions. This feature also allows to characterize biochemical processes which lead to abnormal drop size change. The device operates iteratively, running RL algorithms to achieve a user-defined target droplet size. After set iterations, the device prompts the user for permission to increase the iteration count or alter flow conditions as per the prediction algorithm. The effectiveness and versatility of the device in achieving precise droplet size is evaluated using experiments conducted under various experimental conditions. The device will contribute to the advancement of microfluidic droplet development technologies for various applications, including drug delivery, diagnostics, and chemical analysis.


  • A Portable Handheld Microfluidic Colorimetric Device for the Detection of Organophosphorus Pesticides

    by K. S. Deepak, Satish Kumar Dubey, Sanket Goel, Arshad Javed

    The increasing usage of organophosphorus pesticides (OP) has posed a public concern. To tackle these concerns we developed a portable microfluidic device with integrated electronics and IoT capabilities for rapid and on-site OP residue detection. Malathion, Chlorpyrifos, Dimethoate and a mix of 8 pesticides were chosen for device calibration owing to their wide usage in agriculture. The developed device works on the colorimetric principle and consists of an optoelectronic circuit comprising an LED-Photodiode detection unit, a trans-impedance amplifier unit, a microcontroller, and a filter circuit. The miniaturized device is powered using a 9V power supply and housed in a 3D-printed enclosure. A PDMS-based microfluidic chip was developed for facilitating the molybdenum-based chemical reaction with split and recombine, and spiral micromixers for mixing. The device could detect pesticides within the maximum residual limits as reported by International Food standards with a limit of Detection (LoD) for malathion, chlorpyrifos, dimethoate and OP mix found to be 2.35, 0.20, 0.63, and 0.07 ppm respectively. The findings substantiated that the developed rapid, low-cost point-of-care testing device is an integrated solution for the non-destructive detection of OP residues in citrus fruits and vegetables thus exploring the arenas of point-of-care testing devices for various food safety applications in limited resource settings.


  • Disposable Paper-Based Miniaturized Device for Sensing of Phthalates

    by Jaligam Murali Mohan, Sanjeet Kumar, Khairunnisa Amreen, Arshad Javed, Satish Kumar Dubey, Sanket Goel

    One of the most frequent plasticizers that can cause endocrine disruption is phthalates. The phthalates are utilized in the production of consumer plastic items, leading to increase the risk of exposure of the items stored in water bottles, beverage drinks and food. Further, bioaccumulation and harmful consequences amongst animal life is also prevalent. Therefore, detection of phthalates over a period of time is crucial in food safety and quality. The present work aims to develop a point-of-care, screen-printed, disposable paper device, for detection of phthalates. The device was integrated with buckypaper for efficient detection of phthalates. Primarily, phthalates response was analyzed in the standard three-electrode system where the buckypaper was used as a working electrode. Further, a paper device was fabricated using screen-printing approach and the device was tested for phthalates sensing. The traditional approach and the screen-printed device exhibited a very similar electrocatalytic oxidation of phthalates at E = -0.25 V using the miniaturized portable Potentiostat. Hence, can be used for point-of-care analysis. Subsequently, various electrochemical parameters were also examined. The device provided a linear range of 70 ppm to 15 ppm with a detection limit of 12.64 ppm and quantification limit as 42.03 ppm. Finally, the device was validated for repeatability and stability. As the analysis for real time sensing, local tap water was used with the standard addition method and the recovery percentages were remarkable. Based on the promising results and benchmarked form-factor, this device has the potential to be used as point-of-care testing platform.


  • Microfluidic Device Integrated With PDMS Microchannel and Unmodified ITO Glass Electrodes for Highly Sensitive, Specific, and Point-of-Care Detection of Copper and Mercury

    by Jaligam Murali Mohan, Sohan Dudala, Khairunnisa Amreen, Arshad Javed, Satish Kumar Dubey, Sanket Goel

    This work delves upon developing a two-layer plasma-bonded microfluidic device with a microchannel layer and electrodes for electroanalytical detection of heavy metal ions. The three-electrode system was realized on an ITO-glass slide by suitably etching the ITO layer with the help of CO 2 laser. The microchannel layer was fabricated using a PDMS soft-lithography method wherein the mold created by maskless lithography. The optimized dimensions opted to develop a microfluidic device with length of 20 mm, width of 0.5 mm and gap of 1 mm. The device, with bare unmodified ITO electrodes, was tested to detect Cu and Hg by a portable potentiostat connected with a smartphone. The analytes were introduced in the microfluidic device with a peristaltic pump at an optimal flow rate of 90 μL/min. The device exhibited sensitive electro-catalytic sensing of both the metals by achieving an oxidation peak at -0.4 V and 0.1 V for Cu and Hg respectively. Furthermore, square wave voltammetry (SWV) approach was used to analyze the scan rate effect and concentration effect. The device also used to simultaneously detect both the analytes. During simultaneous sensing of Hg and Cu, the linear range was observed between 2 μM to 100 μM, the limit of detection (LOD) was found to be 0.04 μM and 3.19 μM for Cu and Hg respectively. Further, no interference with other co-existing metal ions was found manifesting the specificity of the device to Cu and Hg. Finally, the device was successfully tested with real samples like tap water, lake water, and serum with remarkable recovery percentages. Such portable devices pave way for detecting various heavy metal ions in a point-of-care environment. The developed device can also be used for detection of other heavy metals like cadmium, lead, zinc etc., by modifying the working electrode with the various nanocomposites.


  • Statistical analysis and optimization of fuel cells using the design of experiment

    by Sarthak Dwivedi, Lanka Tata Rao, Shashwat Goel, Satish Kumar Dubey, Arshad Javed, Sanket Goel

    Evidently, paper-based microfluidic devices, including fuel cells, have been proven to power low-power integrated miniaturized devices. However, the harvested energy depends on various design parameters, positioning and other ancillary factors. Herein, design of experiment is used to make a boisterous study of the data used in paper-based microfluidic fuel cell and to make various optimizations and studies of the raw data used in the microbial fuel cell paper. The paper-based microfluidic fuel cell was analysed for two different positioning, horizontal and vertical, and the maximum power outputs were noted. A statistical technique based on full factorial design was used to study the performance of paper-based microfluidic fuel cell. In the microbial fuel cell, a rigorous study was conducted pertaining to the electrode separation, channel variation and absorbent pad stability. In both these cases, the analysis of mean, analysis of variance, signal-to-noise ratio and desirability study were performed. For the paper-based microfluidic fuel cell, the best desirability values for the horizontal and vertical arrangements were measured to be 0.8842 and 0.92768, respectively. For the microbial fuel cell, in the case of 2 mm electrode separation, the present analysis of variance model came out to be significant. Inclusively, this work provides a pathway to realize optimum paper-based microfluidic fuel cell, and such study can be extrapolated to develop other microfluidic devices.


  • Open Access

    Lab-on-Chip Integrated Platform with Screen Printed Electrodes and Laser Induced Graphene Heater for Simultaneous Culture and Electrochemical Detection of Bacteria

    by Sangam Srikanth, U. S. Jayapiriya, Satish Kumar Dubey, Arshad Javed, Sanket Goel

    Cultivation of bacteria through traditional approach in microbiology is laborious and time intensive. To identify the bacteria concentration after culture, various detection techniques, such as plating, optical imaging or biological modifications, are employed, which are expensive and demands skilled personnel. Therefore, that there is a need to integrate culture and detection processes on a single platform while achieving the same performance. Inspired by such challenges, herein, a simple, cost-effective and miniaturized lab-on-a-chip platform has been developed amenable to perform simultaneous cultivation and detection of bacteria. To achieve this, a microfluidic chamber was integrated to screen-printed carbon electrodes for electrochemical detection of bacteria. The temperature required for the bacteria culture was provided through the optimized laser induced graphene heaters earlier established by our group. The concentration of bacteria was quantified accurately with the three electrode system in the range of 2 × 104 to 1.1 × 109 CFU/ml without any need of biological modifications to the electrodes. The cultured bacteria in microfluidic device was compared to that of the conventionally cultured bacteria and the growth was found to be relatively equal. In addition, the viability of cultured bacteria in the microfluidic device was also confirmed through fluorescent imaging. Furthermore, the metabolic activity of the cultured bacteria was validated by using it as a miniaturized microbial fuel cell. Finally, a handheld and portable lab-on-a-chip platform was realized by 3D packaging integrated with a portable potentiostat for real time and on-field applications. Such platform is amenable to be leveraged for diverse biotechnological applications.


  • Parametric analysis of topologically optimized mechanical member considering dynamic loading

    by G Lakshmi Srinivas, Arshad Javed

    The optimal topology and its performance in dynamic loading situations result in discontinue function corresponding to the input factors such as volume fraction, thickness, material property, and loading conditions. In a realist scenario, the performance prediction becomes erroneous and challenging for the components under dynamic loading conditions with uncertainties. The conventional closed-form deterministic approaches are complicated for these problems. Here, a method is presented to establish the relative influence and function relationship of the input factors with the performance values, including controllable and non-controllable uncertainties. The design of experiment approach is used to apply full factorial design with Taguchi’s orthogonal array; performances of the optimal topologies are considered responses. The non-uniform topology generation method is applied based on the deflection threshold value to generate topologies for dynamic conditions. A dynamic model of the manipulator-link is developed to apply boundary conditions and provide performance values: compliance, deflection, Stress, and energy consumption values. Statistical techniques such as the analysis-of-mean (ANOM), analysis-of-variance (ANOVA), signal-to-noise-ratio (SNR), and mean performance values are employed to observe the significance of input factors and generate equivalent preformation relation. From ANOM and ANOVA, all input parameters show mutual interaction; force is observed as the most significant factor. From SNR values, experimental combination number 9,9,6,1 is observed as the most robust for compliance (21.13), deflection (43.93), Stress (−16.64), and energy consumption (12.05). Similarly, at the same combinations, the mean performance values are minimum and coefficient of determination (R2) percentages of the model are 94.64%, 96.93%, 73.69%, and 95.14%.