Wolfgang Wuest
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wolfgang Wuest has a total of 114 co-authors. Here are the top co-authors by number of shared publications:
- Michael Uder
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
16 shared publications - Matthias Stefan May
Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg and Uniklinikum Erlangen, Erlangen, Germany
15 shared publications - Rafael Heiss
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
13 shared publications - Marco Wiesmueller
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
7 shared publications Michael Uder
Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
5 shared publicationsM. Uder
Radioloical Institute, Friedrich-Alexander-University-Erlangen-Nuremberg, Erlangen, Germany
4 shared publications
Latest Publications
- 10 October 2024
- Published by Springer Nature
- p. 145-264
Nasennebenhöhlen, vordere und zentrale Schädelbasis
- 10 October 2024
- Published by Springer Nature
- p. 145-264
Nasennebenhöhlen, vordere und zentrale Schädelbasis
- Open Access
- 28 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1362
Diagnostic Accuracy and Performance Analysis of a Scanner-Integrated Artificial Intelligence Model for the Detection of Intracranial Hemorrhages in a Traumatology Emergency Department
Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.
- 28 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1362
Open AccessDiagnostic Accuracy and Performance Analysis of a Scanner-Integrated Artificial Intelligence Model for the Detection of Intracranial Hemorrhages in a Traumatology Emergency Department
Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.
- Open Access
- 18 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2403
Free-Breathing and Single-Breath Hold Compressed Sensing Real-Time MRI of Right Ventricular Function in Children with Congenital Heart Disease
(1) Purpose: to compare right ventricular (RV) functional parameters in children with surgically repaired congenital heart disease (CHD) using single/double breath hold (BH) and free-breathing (FB) real-time compressed sensing (CS) cine cardiac magnetic resonance (cMRI) with standard retrospective segmented multi breath hold (RMB) cine cMRI. (2) Methods: Twenty patients with CHD underwent BH and FB, as well as RMB cine cMRI, at 3T to obtain a stack of continuous axial images of the RV. Two radiologists independently performed qualitative analysis of the image quality (rated on a 5-point scale; 1 = non-diagnostic to 5 = excellent) and quantitative analysis of the RV volume measurements. (3) Results: The best image quality was provided by RMB (4.5; range 2–5) compared to BH (3.9; range 3–5; p = 0.04) and FB (3.6; range 3–5; p < 0.01). The RV functional parameters were comparable among BH, FB, and RMB with a difference of less than 5%. The scan times for BH (44 ± 38 s, p < 0.01) and FB (24 ± 7 s, p < 0.01) were significantly reduced compared to for RMB (261 ± 68 s). (4) Conclusions: CS-FB and CS-BH real-time cine cMRI in children with CHD provides diagnostic image quality with excellent accuracy for measuring RV function with a significantly reduced scan time compared to RMB.
- 18 July 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (14) , 2403
Open AccessFree-Breathing and Single-Breath Hold Compressed Sensing Real-Time MRI of Right Ventricular Function in Children with Congenital Heart Disease
(1) Purpose: to compare right ventricular (RV) functional parameters in children with surgically repaired congenital heart disease (CHD) using single/double breath hold (BH) and free-breathing (FB) real-time compressed sensing (CS) cine cardiac magnetic resonance (cMRI) with standard retrospective segmented multi breath hold (RMB) cine cMRI. (2) Methods: Twenty patients with CHD underwent BH and FB, as well as RMB cine cMRI, at 3T to obtain a stack of continuous axial images of the RV. Two radiologists independently performed qualitative analysis of the image quality (rated on a 5-point scale; 1 = non-diagnostic to 5 = excellent) and quantitative analysis of the RV volume measurements. (3) Results: The best image quality was provided by RMB (4.5; range 2–5) compared to BH (3.9; range 3–5; p = 0.04) and FB (3.6; range 3–5; p < 0.01). The RV functional parameters were comparable among BH, FB, and RMB with a difference of less than 5%. The scan times for BH (44 ± 38 s, p < 0.01) and FB (24 ± 7 s, p < 0.01) were significantly reduced compared to for RMB (261 ± 68 s). (4) Conclusions: CS-FB and CS-BH real-time cine cMRI in children with CHD provides diagnostic image quality with excellent accuracy for measuring RV function with a significantly reduced scan time compared to RMB.
- Open Access
- 25 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (7) , 1242
Comparison of Diagnostic Performance and Image Quality between Topup-Corrected and Standard Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Cholesteatoma Diagnostics
This study compares the diagnostic performance and image quality of single-shot turbo spin-echo DWI (tseDWI), standard readout-segmented DWI (rsDWI), and a modified rsDWI version (topupDWI) for cholesteatoma diagnostics. Thirty-four patients with newly suspected unilateral cholesteatoma were examined on a 1.5 Tesla MRI scanner. Diagnostic performance was evaluated by calculating and comparing the sensitivity and specificity using histopathological results as the standard of reference. Image quality was independently reviewed by two readers using a 5-point Likert scale evaluating image distortions, susceptibility artifacts, image resolution, lesion conspicuity, and diagnostic confidence. Twenty-five cholesteatomas were histologically confirmed after surgery and originated in the study group. TseDWI showed the highest sensitivity with 96% (95% confidence interval (CI): 88–100%), followed by topupDWI with 92% (95% CI: 81–100%) for both readers. The sensitivity for rsDWI was 76% (95% CI: 59–93%) for reader 1 and 84% (95% CI: 70–98%) for reader 2, respectively. Both tseDWI and topupDWI revealed a specificity of 100% (95% CI: 66–100%) and rsDWI of 89% (95% CI: 52–100%). Both tseDWI and topupDWI showed fewer image distortions and susceptibility artifacts compared to rsDWI. Image resolution was consistently rated best for topupDWI, followed by rsDWI, which both outperformed tseDWI. TopupDWI and tseDWI showed comparable results for lesions’ conspicuity and diagnostic confidence, both outperforming rsDWI. Modified readout-segmented DWI using the topup-correction method is preferable to standard rsDWI and may be regarded as an accurate alternative to single-shot turbo spin-echo DWI in cholesteatoma diagnostics.
- 25 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (7) , 1242
Open AccessComparison of Diagnostic Performance and Image Quality between Topup-Corrected and Standard Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Cholesteatoma Diagnostics
This study compares the diagnostic performance and image quality of single-shot turbo spin-echo DWI (tseDWI), standard readout-segmented DWI (rsDWI), and a modified rsDWI version (topupDWI) for cholesteatoma diagnostics. Thirty-four patients with newly suspected unilateral cholesteatoma were examined on a 1.5 Tesla MRI scanner. Diagnostic performance was evaluated by calculating and comparing the sensitivity and specificity using histopathological results as the standard of reference. Image quality was independently reviewed by two readers using a 5-point Likert scale evaluating image distortions, susceptibility artifacts, image resolution, lesion conspicuity, and diagnostic confidence. Twenty-five cholesteatomas were histologically confirmed after surgery and originated in the study group. TseDWI showed the highest sensitivity with 96% (95% confidence interval (CI): 88–100%), followed by topupDWI with 92% (95% CI: 81–100%) for both readers. The sensitivity for rsDWI was 76% (95% CI: 59–93%) for reader 1 and 84% (95% CI: 70–98%) for reader 2, respectively. Both tseDWI and topupDWI revealed a specificity of 100% (95% CI: 66–100%) and rsDWI of 89% (95% CI: 52–100%). Both tseDWI and topupDWI showed fewer image distortions and susceptibility artifacts compared to rsDWI. Image resolution was consistently rated best for topupDWI, followed by rsDWI, which both outperformed tseDWI. TopupDWI and tseDWI showed comparable results for lesions’ conspicuity and diagnostic confidence, both outperforming rsDWI. Modified readout-segmented DWI using the topup-correction method is preferable to standard rsDWI and may be regarded as an accurate alternative to single-shot turbo spin-echo DWI in cholesteatoma diagnostics.
- Open Access
- 13 September 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (3) , 216-222
Time-of-Flight Angiography in Ultra-High-Field 7 T MRI for the Evaluation of Peroneal Perforator Arteries Before Osseomyocutaneous Flap Surgery
Objectives: Presurgical identification and morphologic characterization of the peroneal perforator arteries (PPAs) are essential for osseomyocutaneous flap surgery. The aim of this study was to evaluate PPAs using time-of-flight (TOF) angiography in 7 T magnetic resonance imaging in comparison with dual-energy computed tomographic angiography (CTA). Materials and Methods: In this prospective study, TOF angiography and CTA of both lower legs were acquired before flap surgery from 07/2019 to 02/2020. Magnetic resonance imaging was performed using a dedicated 28-channel knee coil with an acquisition time of 9:55 minutes (voxel size: 0.4 × 0.4 × 0.8 mm). Computed tomographic angiography was acquired with a third-generation dual-source computed tomography on the same day. Virtual monoenergetic reconstructions at 40 keV photon energy served as the standard of reference for PPA identification and subtyping. Two independent readers assessed the image quality, quantity, length assessment, and classification according to surgical considerations of PPAs for TOF angiography and CTA. Both TOF angiography and CTA were used for presurgical flap design and were evaluated by an orofacial surgeon. Results: Ten patients (mean age, 59.9 ± 14.9 years; 7 men) were included. Time-of-flight angiography and CTA identified 53 and 51 PPAs in total, respectively. Time-of-flight angiography showed superior image quality (both readers, P < 0.05). Time-of-flight angiography enabled specific classification of PPA subtypes more often (53 vs 39; P < 0.05), and both readers reported higher diagnostic confidence for TOF angiography than CTA in all patients (interrater agreement κ = 0.8; P < 0.05). Regarding length assessment, PPAs were significantly more conspicuous with TOF angiography (TOFmean, 50 ± 11 mm; CTAmean, 40 ± 9 mm; P = 0.001). In comparison with CTA, TOF angiography prospectively changed the orofacial surgeon's final decision on the presurgical selected PPAs in 60% of cases. Conclusions: Presurgical assessment of PPAs is feasible using TOF in 7 T magnetic resonance imaging. Moreover, TOF angiography was superior to CTA for classifying and identifying PPAs, which may facilitate the planning of reconstructive surgery.
- 13 September 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (3) , 216-222
Open AccessTime-of-Flight Angiography in Ultra-High-Field 7 T MRI for the Evaluation of Peroneal Perforator Arteries Before Osseomyocutaneous Flap Surgery
Objectives: Presurgical identification and morphologic characterization of the peroneal perforator arteries (PPAs) are essential for osseomyocutaneous flap surgery. The aim of this study was to evaluate PPAs using time-of-flight (TOF) angiography in 7 T magnetic resonance imaging in comparison with dual-energy computed tomographic angiography (CTA). Materials and Methods: In this prospective study, TOF angiography and CTA of both lower legs were acquired before flap surgery from 07/2019 to 02/2020. Magnetic resonance imaging was performed using a dedicated 28-channel knee coil with an acquisition time of 9:55 minutes (voxel size: 0.4 × 0.4 × 0.8 mm). Computed tomographic angiography was acquired with a third-generation dual-source computed tomography on the same day. Virtual monoenergetic reconstructions at 40 keV photon energy served as the standard of reference for PPA identification and subtyping. Two independent readers assessed the image quality, quantity, length assessment, and classification according to surgical considerations of PPAs for TOF angiography and CTA. Both TOF angiography and CTA were used for presurgical flap design and were evaluated by an orofacial surgeon. Results: Ten patients (mean age, 59.9 ± 14.9 years; 7 men) were included. Time-of-flight angiography and CTA identified 53 and 51 PPAs in total, respectively. Time-of-flight angiography showed superior image quality (both readers, P < 0.05). Time-of-flight angiography enabled specific classification of PPA subtypes more often (53 vs 39; P < 0.05), and both readers reported higher diagnostic confidence for TOF angiography than CTA in all patients (interrater agreement κ = 0.8; P < 0.05). Regarding length assessment, PPAs were significantly more conspicuous with TOF angiography (TOFmean, 50 ± 11 mm; CTAmean, 40 ± 9 mm; P = 0.001). In comparison with CTA, TOF angiography prospectively changed the orofacial surgeon's final decision on the presurgical selected PPAs in 60% of cases. Conclusions: Presurgical assessment of PPAs is feasible using TOF in 7 T magnetic resonance imaging. Moreover, TOF angiography was superior to CTA for classifying and identifying PPAs, which may facilitate the planning of reconstructive surgery.
- Open Access
- 1 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1860
Apparent Diffusion Coefficient (ADC) Histogram Analysis in Parotid Gland Tumors: Evaluating a Novel Approach for Differentiation between Benign and Malignant Parotid Lesions Based on Full Histogram Distributions
The aim of this study was to assess the diagnostic value of ADC distribution curves for differentiation between benign and malignant parotid gland tumors and to compare with mean ADC values. 73 patients with parotid gland tumors underwent head-and-neck MRI on a 1.5 Tesla scanner prior to surgery and histograms of ADC values were extracted. Histopathological results served as a reference standard for further analysis. ADC histograms were evaluated by comparing their similarity to a reference distribution using Chi2-test-statistics. The assumed reference distribution for benign and malignant parotid gland lesions was calculated after pooling the entire ADC data. In addition, mean ADC values were determined. For both methods, we calculated and compared the sensitivity and specificity between benign and malignant parotid gland tumors and three subgroups (pleomorphic adenoma, Warthin tumor, and malignant lesions), respectively. Moreover, we performed cross-validation (CV) techniques to estimate the predictive performance between ADC distributions and mean values. Histopathological results revealed 30 pleomorphic adenomas, 22 Warthin tumors, and 21 malignant tumors. ADC histogram distribution yielded a better specificity for detection of benign parotid gland lesions (ADChistogram: 75.0% vs. ADCmean: 71.2%), but mean ADC values provided a higher sensitivity (ADCmean: 71.4% vs. ADChistogram: 61.9%). The discrepancies are most pronounced in the differentiation between malignant and Warthin tumors (sensitivity ADCmean: 76.2% vs. ADChistogram: 61.9%; specificity ADChistogram: 81.8% vs. ADCmean: 68.2%). Using CV techniques, ADC distribution revealed consistently better accuracy to differentiate benign from malignant lesions (“leave-one-out CV” accuracy ADChistogram: 71.2% vs. ADCmean: 67.1%). ADC histogram analysis using full distribution curves is a promising new approach for differentiation between primary benign and malignant parotid gland tumors, especially with respect to the advantage in predictive performance based on CV techniques.
- 1 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1860
Open AccessApparent Diffusion Coefficient (ADC) Histogram Analysis in Parotid Gland Tumors: Evaluating a Novel Approach for Differentiation between Benign and Malignant Parotid Lesions Based on Full Histogram Distributions
The aim of this study was to assess the diagnostic value of ADC distribution curves for differentiation between benign and malignant parotid gland tumors and to compare with mean ADC values. 73 patients with parotid gland tumors underwent head-and-neck MRI on a 1.5 Tesla scanner prior to surgery and histograms of ADC values were extracted. Histopathological results served as a reference standard for further analysis. ADC histograms were evaluated by comparing their similarity to a reference distribution using Chi2-test-statistics. The assumed reference distribution for benign and malignant parotid gland lesions was calculated after pooling the entire ADC data. In addition, mean ADC values were determined. For both methods, we calculated and compared the sensitivity and specificity between benign and malignant parotid gland tumors and three subgroups (pleomorphic adenoma, Warthin tumor, and malignant lesions), respectively. Moreover, we performed cross-validation (CV) techniques to estimate the predictive performance between ADC distributions and mean values. Histopathological results revealed 30 pleomorphic adenomas, 22 Warthin tumors, and 21 malignant tumors. ADC histogram distribution yielded a better specificity for detection of benign parotid gland lesions (ADChistogram: 75.0% vs. ADCmean: 71.2%), but mean ADC values provided a higher sensitivity (ADCmean: 71.4% vs. ADChistogram: 61.9%). The discrepancies are most pronounced in the differentiation between malignant and Warthin tumors (sensitivity ADCmean: 76.2% vs. ADChistogram: 61.9%; specificity ADChistogram: 81.8% vs. ADCmean: 68.2%). Using CV techniques, ADC distribution revealed consistently better accuracy to differentiate benign from malignant lesions (“leave-one-out CV” accuracy ADChistogram: 71.2% vs. ADCmean: 67.1%). ADC histogram analysis using full distribution curves is a promising new approach for differentiation between primary benign and malignant parotid gland tumors, especially with respect to the advantage in predictive performance based on CV techniques.
- Open Access
- 22 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (7) , 1761
Controversial Aspects of Diagnostics and Therapy of Arthritis of the Temporomandibular Joint in Rheumatoid and Juvenile Idiopathic Arthritis—An Analysis of Evidence- and Consensus-Based Recommendations Based on an Interdisciplinary Guideline Project
Introduction: Due to potentially severe sequelae (impaired growth, condylar resorption, and ankylosis) early diagnosis of chronic rheumatic arthritis of the temporomandibular joint (TMJ) and timely onset of therapy are essential. Aim: Owing to very limited evidence the aim of the study was to identify and discuss controversial topics in the guideline development to promote further focused research. Methods: Through a systematic literature search, 394 out of 3771 publications were included in a German interdisciplinary guideline draft. Two workgroups (1: oral and maxillofacial surgery, 2: interdisciplinary) voted on 77 recommendations/statements, in 2 independent anonymized and blinded consensus phases (Delphi process). Results: The voting results were relatively homogenous, except for a greater proportion of abstentions amongst the interdisciplinary group (p < 0.001). Eighty-four percent of recommendations/statements were approved in the first round, 89% with strong consensus. Fourteen recommendations/statements (18.2%) required a prolonged consensus phase and further discussion. Discussion: Contrast-enhanced MRI was confirmed as the method of choice for the diagnosis of TMJ arthritis. Intraarticular corticosteroid injection is to be limited to therapy-refractory cases and single injection only. In adults, alloplastic joint replacement is preferable to autologous replacement. In children/adolescents, autologous reconstruction may be performed lacking viable alternatives. Alloplastic options are currently still considered experimental.
- 22 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (7) , 1761
Open AccessControversial Aspects of Diagnostics and Therapy of Arthritis of the Temporomandibular Joint in Rheumatoid and Juvenile Idiopathic Arthritis—An Analysis of Evidence- and Consensus-Based Recommendations Based on an Interdisciplinary Guideline Project
Introduction: Due to potentially severe sequelae (impaired growth, condylar resorption, and ankylosis) early diagnosis of chronic rheumatic arthritis of the temporomandibular joint (TMJ) and timely onset of therapy are essential. Aim: Owing to very limited evidence the aim of the study was to identify and discuss controversial topics in the guideline development to promote further focused research. Methods: Through a systematic literature search, 394 out of 3771 publications were included in a German interdisciplinary guideline draft. Two workgroups (1: oral and maxillofacial surgery, 2: interdisciplinary) voted on 77 recommendations/statements, in 2 independent anonymized and blinded consensus phases (Delphi process). Results: The voting results were relatively homogenous, except for a greater proportion of abstentions amongst the interdisciplinary group (p < 0.001). Eighty-four percent of recommendations/statements were approved in the first round, 89% with strong consensus. Fourteen recommendations/statements (18.2%) required a prolonged consensus phase and further discussion. Discussion: Contrast-enhanced MRI was confirmed as the method of choice for the diagnosis of TMJ arthritis. Intraarticular corticosteroid injection is to be limited to therapy-refractory cases and single injection only. In adults, alloplastic joint replacement is preferable to autologous replacement. In children/adolescents, autologous reconstruction may be performed lacking viable alternatives. Alloplastic options are currently still considered experimental.
- 21 March 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (6) , 2187-2196
Prostate cancer in PI-RADS scores 1 and 2 version 2.1: a comparison to previous PI-RADS versions
Purpose To evaluate the validity of PI-RADS categories 1 and 2 version 2.1 (V2.1) as predictors of the absence of carcinoma and to reevaluate lesions that were analysed as suspicious prior to PI-RADS or according to PI-RADS versions 1 and 2 and classified as PI-RADS 1 or 2 in V2.1. Methods Retrospective evaluation of 1170 multiparametric MRIs performed at one academic teaching hospital (2012–2019). Study cohort comprised 188 men that achieved PI-RADS scores 1 or 2 (V2.1) and underwent systematic and targeted biopsy, split into one group with suspect findings in the original reports that were created prior to PI-RADS or with version 1 and 2, and another group with unremarkable reports. Differences in presence of prostate cancer and PSA density were assessed by Chi-square and Fisher’s exact test, and the negative predictive value (NPV) for both groups was conducted. Results The NPV for clinically significant carcinoma (csCa) was 89.1% for 55 men with suspect findings in the original report and 93.2% for 133 men with negative MRI. There was no difference between the groups regarding the detection of csCa (p = 0.103). PSA density was significantly higher in the group with suspect original reports (p = 0.015). Conclusion A PI-RADS score 1 or 2 appears less likely to miss existing prostate cancer, although a small amount of csCa can be overlooked. In case of clinical suspicion or elevated PSA density and PI-RADS score 1 or 2, an individual decision has to be taken if biopsy is necessary or if monitoring is sufficient. Graphical abstract
- 21 March 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (6) , 2187-2196
Prostate cancer in PI-RADS scores 1 and 2 version 2.1: a comparison to previous PI-RADS versions
Purpose To evaluate the validity of PI-RADS categories 1 and 2 version 2.1 (V2.1) as predictors of the absence of carcinoma and to reevaluate lesions that were analysed as suspicious prior to PI-RADS or according to PI-RADS versions 1 and 2 and classified as PI-RADS 1 or 2 in V2.1. Methods Retrospective evaluation of 1170 multiparametric MRIs performed at one academic teaching hospital (2012–2019). Study cohort comprised 188 men that achieved PI-RADS scores 1 or 2 (V2.1) and underwent systematic and targeted biopsy, split into one group with suspect findings in the original reports that were created prior to PI-RADS or with version 1 and 2, and another group with unremarkable reports. Differences in presence of prostate cancer and PSA density were assessed by Chi-square and Fisher’s exact test, and the negative predictive value (NPV) for both groups was conducted. Results The NPV for clinically significant carcinoma (csCa) was 89.1% for 55 men with suspect findings in the original report and 93.2% for 133 men with negative MRI. There was no difference between the groups regarding the detection of csCa (p = 0.103). PSA density was significantly higher in the group with suspect original reports (p = 0.015). Conclusion A PI-RADS score 1 or 2 appears less likely to miss existing prostate cancer, although a small amount of csCa can be overlooked. In case of clinical suspicion or elevated PSA density and PI-RADS score 1 or 2, an individual decision has to be taken if biopsy is necessary or if monitoring is sufficient. Graphical abstract
- Open Access
- 29 January 2022
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 38 (2) , 411
Correction to: Effect of long term CPAP therapy on cardiac parameters assessed with cardiac MRI
- 29 January 2022
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 38 (2) , 411
Open AccessCorrection to: Effect of long term CPAP therapy on cardiac parameters assessed with cardiac MRI
- Open Access
- 26 October 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 1989
Dual-Energy Lung Perfusion in Portal Venous Phase CT—A Comparison with the Pulmonary Arterial Phase
Pulmonary arterial dual-energy (aDE) CT is an established technique for evaluating pulmonary perfusion blood volume (PBV). As DECT protocols are increasingly used for thoraco-abdominal CT, this study assessed image quality and clinical findings in portal–venous phase dual-energy (vDE) CT and compared it to aDE. In 95 patients, vDE-CT was performed using a dual-source scanner (70/Sn150 kV, 560/140 ref.mAs). Pulmonary triggered aDE-CT served as reference (n = 94). PBV was reconstructed using a dedicated algorithm. Mean relative attenuation was measured in the pulmonary trunk, aorta, and segmented lung parenchyma. A distribution ratio (DL) between vessels and parenchyma was calculated to assess the iodine uptake of the lung parenchyma. Subjective overall diagnostic image quality was assessed for PBV images on a five-point Likert scale. Image artifacts were classified into five groups based on scale rating and compared between vDE and aDE. Pathological findings were correlated with the anatomical image datasets. Mean relative attenuation of the lung parenchyma was comparable in both groups (vDE: 23 ± 6 HU and aDE: 22 ± 7 HU), but significantly lower in the vessels of vDE. Therefore, iodine uptake of the lung parenchyma was significantly higher in vDE (DL: 10% vs. 8%, p < 0.01). The subjective overall image quality of the PBV images was comparable (p = 0.5). Rotation and streak artifacts were found in most of the patients (>86%, both p > 0.6). Dual-source artifacts were found in only a few patients in both groups (vDE 5%, aDE 7%, p = 0.5). Recess and subpleural artifacts were increased in vDE (vDE 53/27%, aDE 24/7%, both p < 0.001). Pathological findings were found in 19% of the vDE patients and 59% of the aDE patients. Comparable objective and subjective image quality of lung perfusion can be obtained in vDE and aDE. Iodine uptake of the lung parenchyma is increased in vDE compared to aDE, suggesting an interstitial pooling effect. Knowledge of the different appearances of artifacts will aid in the interpretation of the images. Additional clinical information about the lung parenchyma can be provided by PBV evaluation in vDE.
- 26 October 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 1989
Open AccessDual-Energy Lung Perfusion in Portal Venous Phase CT—A Comparison with the Pulmonary Arterial Phase
Pulmonary arterial dual-energy (aDE) CT is an established technique for evaluating pulmonary perfusion blood volume (PBV). As DECT protocols are increasingly used for thoraco-abdominal CT, this study assessed image quality and clinical findings in portal–venous phase dual-energy (vDE) CT and compared it to aDE. In 95 patients, vDE-CT was performed using a dual-source scanner (70/Sn150 kV, 560/140 ref.mAs). Pulmonary triggered aDE-CT served as reference (n = 94). PBV was reconstructed using a dedicated algorithm. Mean relative attenuation was measured in the pulmonary trunk, aorta, and segmented lung parenchyma. A distribution ratio (DL) between vessels and parenchyma was calculated to assess the iodine uptake of the lung parenchyma. Subjective overall diagnostic image quality was assessed for PBV images on a five-point Likert scale. Image artifacts were classified into five groups based on scale rating and compared between vDE and aDE. Pathological findings were correlated with the anatomical image datasets. Mean relative attenuation of the lung parenchyma was comparable in both groups (vDE: 23 ± 6 HU and aDE: 22 ± 7 HU), but significantly lower in the vessels of vDE. Therefore, iodine uptake of the lung parenchyma was significantly higher in vDE (DL: 10% vs. 8%, p < 0.01). The subjective overall image quality of the PBV images was comparable (p = 0.5). Rotation and streak artifacts were found in most of the patients (>86%, both p > 0.6). Dual-source artifacts were found in only a few patients in both groups (vDE 5%, aDE 7%, p = 0.5). Recess and subpleural artifacts were increased in vDE (vDE 53/27%, aDE 24/7%, both p < 0.001). Pathological findings were found in 19% of the vDE patients and 59% of the aDE patients. Comparable objective and subjective image quality of lung perfusion can be obtained in vDE and aDE. Iodine uptake of the lung parenchyma is increased in vDE compared to aDE, suggesting an interstitial pooling effect. Knowledge of the different appearances of artifacts will aid in the interpretation of the images. Additional clinical information about the lung parenchyma can be provided by PBV evaluation in vDE.