J. Francis Turner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
J. Francis Turner has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Christoforos Kosmidis
School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
2 shared publications - Konstantinos Sapalidis
3rd Surgical Department, AHEPA University Hospital, Aristotle University of Thessaloniki, 54636 Thessaloniki, Greece
2 shared publications - Paul Zarogoulidis
Pulmonary Department, General Clinic Euromedica, Thessaloniki, Greece
2 shared publications - Aristeidis Ioannidis
Department of Surgery, Aristotle University of Thessaloniki, 54636 Thessaloniki, Greece
1 shared publication Brandy Harmon
Western Regional Medical Center, Cancer Treatment Centers of America, Goodyear/AZ/United States of America
1 shared publicationCherae Bilagody
Northern Arizona University, Flagstaff/AZ/United States of America
1 shared publication
Latest Publications
- Open Access
- 17 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (6) , 3569
Radial-EBUS: CryoBiopsy Versus Conventional Biopsy: Time-Sample and C-Arm
Introduction: Diagnosis of lung nodules is still under investigation. We use computed tomography scans and positron emission tomography in order to identify their origin. Patients and Methods: In our retrospective study, we included 248 patients with a single lung nodule or multiple lung nodules of size ≥1 cm. We used a radial-endobronchial ultrasound and a C-Arm. We used a 1.1 mm cryoprobe versus a 22G needle vs. forceps/brush. We compared the sample size of each biopsy method with the number of cell-block slices. Results: Central lesions indifferent to the method provided the same mean number of cell-block slices (0.04933–0.02410). Cryobiopsies provide less sample size for peripheral lesions due to the higher incidence of pneumothorax (0.04700–0.02296). Conclusion: The larger the lesion ≥2 cm, and central, more cell-blocks are produced indifferent to the biopsy method (0.13386–0.02939). The time of the procedure was observed to be less when the C-Arm was used as an additional navigation tool (0.14854–0.00089).
- 17 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (6) , 3569
Open AccessRadial-EBUS: CryoBiopsy Versus Conventional Biopsy: Time-Sample and C-Arm
Introduction: Diagnosis of lung nodules is still under investigation. We use computed tomography scans and positron emission tomography in order to identify their origin. Patients and Methods: In our retrospective study, we included 248 patients with a single lung nodule or multiple lung nodules of size ≥1 cm. We used a radial-endobronchial ultrasound and a C-Arm. We used a 1.1 mm cryoprobe versus a 22G needle vs. forceps/brush. We compared the sample size of each biopsy method with the number of cell-block slices. Results: Central lesions indifferent to the method provided the same mean number of cell-block slices (0.04933–0.02410). Cryobiopsies provide less sample size for peripheral lesions due to the higher incidence of pneumothorax (0.04700–0.02296). Conclusion: The larger the lesion ≥2 cm, and central, more cell-blocks are produced indifferent to the biopsy method (0.13386–0.02939). The time of the procedure was observed to be less when the C-Arm was used as an additional navigation tool (0.14854–0.00089).
- Open Access
- 11 July 2019
- Published by Hindawi Limited in Case Reports in Pulmonology
- Vol. 2019, 1-5
Chylothorax and Chylopericardium: A Complication of Long-Term Central Venous Catheter Use
The development of chylothorax and chylopericardium is an uncommon complication of the long-term use of central venous catheters. We describe a unique case of an end stage renal disease patient on hemodialysis with a left jugular tunneled catheter who developed superior vena cava syndrome. Our patient presented with both a large pleural and pericardial effusion that despite drainage continued to reaccumulate. Further imaging with CT scan of the thorax revealed stenosis of the superior vena cava leading to recurrent chylothorax and chylopericardium.
- 11 July 2019
- Published by Hindawi Limited in Case Reports in Pulmonology
- Vol. 2019, 1-5
Open AccessChylothorax and Chylopericardium: A Complication of Long-Term Central Venous Catheter Use
The development of chylothorax and chylopericardium is an uncommon complication of the long-term use of central venous catheters. We describe a unique case of an end stage renal disease patient on hemodialysis with a left jugular tunneled catheter who developed superior vena cava syndrome. Our patient presented with both a large pleural and pericardial effusion that despite drainage continued to reaccumulate. Further imaging with CT scan of the thorax revealed stenosis of the superior vena cava leading to recurrent chylothorax and chylopericardium.
- Open Access
- 1 January 2019
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 28, 100952
Endobronchial removal of the high-risk osseous foreign bodies with evaluation and planning by virtual navigation system
- 1 January 2019
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 28, 100952
Open AccessEndobronchial removal of the high-risk osseous foreign bodies with evaluation and planning by virtual navigation system
- 1 January 2017
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 12 (1) , S606-S607
P1.04-019 Final Analysis of Lung Microbiome from Patients Undergoing Bronchoscopy
- 1 January 2017
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 12 (1) , S606-S607
P1.04-019 Final Analysis of Lung Microbiome from Patients Undergoing Bronchoscopy
- Open Access
- 1 December 2015
- Vol. 7, S272-S278
Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration
TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS techniques and reviews the relevant literature.
- 1 December 2015
- Vol. 7, S272-S278
Open AccessEndobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration
TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS techniques and reviews the relevant literature.
- Open Access
- 16 January 2014
- Published by S. Karger AG in Case Reports in Oncology
- Vol. 7 (1) , 39-42
A Case of Pulmonary Infiltrates in a Patient with Colon Carcinoma
A 31-year-old white male with a known history of colon carcinoma was referred to the Interventional Pulmonary service for right lower lobe infiltrates and mucous plugging on computed tomography with concern for pneumonia. Bronchoscopy was performed revealing a broad based mass completely obstructing the bronchus intermedius. It was possible to pass a probe into the right lower lobe, and subsequent photoablation and mechanical debulking revealed that the mass was arising near the origin of the superior basal segment of the right lower lobe (RB6) and could be resected. Pathology confirmed this was consistent with the patient's known primary colon carcinoma. The potential for endobronchial metastasis in patients with colorectal carcinoma should be investigated in those patients with new or worsening pulmonary symptoms and signs.
- 16 January 2014
- Published by S. Karger AG in Case Reports in Oncology
- Vol. 7 (1) , 39-42
Open AccessA Case of Pulmonary Infiltrates in a Patient with Colon Carcinoma
A 31-year-old white male with a known history of colon carcinoma was referred to the Interventional Pulmonary service for right lower lobe infiltrates and mucous plugging on computed tomography with concern for pneumonia. Bronchoscopy was performed revealing a broad based mass completely obstructing the bronchus intermedius. It was possible to pass a probe into the right lower lobe, and subsequent photoablation and mechanical debulking revealed that the mass was arising near the origin of the superior basal segment of the right lower lobe (RB6) and could be resected. Pathology confirmed this was consistent with the patient's known primary colon carcinoma. The potential for endobronchial metastasis in patients with colorectal carcinoma should be investigated in those patients with new or worsening pulmonary symptoms and signs.
- 1 October 2007
- Published by Wolters Kluwer Health in Journal of Bronchology
- Vol. 14 (4) , 246-250
TBNA Versus TENA in the Diagnosis and Staging of Bronchogenic Carcinoma: “A Comparative Study”
Background Transbronchial needle aspiration (TBNA) through the flexible bronchoscope still remains underused and a poorly understood procedure. Recently, transesophageal needle aspiration (TENA) under ultrasound guidance has been used to help stage the posterior mediastinal lymph nodes. Objective TBNA and TENA have both been used for the diagnosis and staging of bronchogenic carcinoma. This study is to compare the efficacy and complimentary potential of these techniques. Design Retrospective review and comparison of a series of consecutive patients. Setting Tertiary referral hospital. Patients Nineteen adult patients with mediastinal adenopathy. Interventions TBNA and TENA. Main Outcome Measurements Specific diagnostic yield of TBNA compared with TENA in adenopathy of the left paratracheal and subcarinal locations. Results Out of 19 patients, specific diagnosis was made in 15 patients (79%) by TBNA and in 13 patients (68%) by TENA. TBNA and TENA were both positive in 5 patients. TBNA alone was positive in 7 patients and TENA alone was positive in 1 patient. In the comparative study group lymph node stations 7, 8, and 5 (L4), there were no significant differences in the diagnostic yield of TBNA and TENA. Limitations Small sample size. Conclusions TBNA remains highly effective for sampling mediastinal lymph node stations. TENA is limited for subcarinal, paraesophageal, and aorto-pulmonary window lymph nodes, which are adjacent to the esophagus. Adding TENA to TBNA did not increase the diagnostic yield even in these subgroups of lymph nodes in our study.
- 1 October 2007
- Published by Wolters Kluwer Health in Journal of Bronchology
- Vol. 14 (4) , 246-250
TBNA Versus TENA in the Diagnosis and Staging of Bronchogenic Carcinoma: “A Comparative Study”
Background Transbronchial needle aspiration (TBNA) through the flexible bronchoscope still remains underused and a poorly understood procedure. Recently, transesophageal needle aspiration (TENA) under ultrasound guidance has been used to help stage the posterior mediastinal lymph nodes. Objective TBNA and TENA have both been used for the diagnosis and staging of bronchogenic carcinoma. This study is to compare the efficacy and complimentary potential of these techniques. Design Retrospective review and comparison of a series of consecutive patients. Setting Tertiary referral hospital. Patients Nineteen adult patients with mediastinal adenopathy. Interventions TBNA and TENA. Main Outcome Measurements Specific diagnostic yield of TBNA compared with TENA in adenopathy of the left paratracheal and subcarinal locations. Results Out of 19 patients, specific diagnosis was made in 15 patients (79%) by TBNA and in 13 patients (68%) by TENA. TBNA and TENA were both positive in 5 patients. TBNA alone was positive in 7 patients and TENA alone was positive in 1 patient. In the comparative study group lymph node stations 7, 8, and 5 (L4), there were no significant differences in the diagnostic yield of TBNA and TENA. Limitations Small sample size. Conclusions TBNA remains highly effective for sampling mediastinal lymph node stations. TENA is limited for subcarinal, paraesophageal, and aorto-pulmonary window lymph nodes, which are adjacent to the esophagus. Adding TENA to TBNA did not increase the diagnostic yield even in these subgroups of lymph nodes in our study.
- 1 January 2005
- Published by Wolters Kluwer Health in Journal of Bronchology
- Vol. 12 (1) , 39-40
Metastatic Osteosarcoma
- 1 January 2005
- Published by Wolters Kluwer Health in Journal of Bronchology
- Vol. 12 (1) , 39-40
Metastatic Osteosarcoma