Chong Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chong Li has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Dequn Zhou
2 shared publicationsDongdong Li
2 shared publicationsHui Wang
2 shared publicationsDa Sheng Zhu
College of Mechanical and Power Engineering, Nanjing University of Technology, No.5 Xin Mo Fan Road, Nanjing 210009, China
1 shared publicationHanliang Zhu
School of Electronic Engineering Nanjing Xiaozhuang University Nanjing Jiangsu 211171 China
1 shared publicationHuanbo Cheng
1 shared publication
Latest Publications
- 10 November 2023
- Published by Wiley in Energy Technology
- Vol. 12 (2)
Technical, Economic, and Environmental Feasibility Assessment of Grid‐Connected Photovoltaic Power Generation Systems with Different Tracking Models in Hefei, China
Herein, the feasibility of a grid‐connected photovoltaic (PV) power generation system with five tracking models in Hefei is evaluated comprehensively. The comprehensive evaluation of grid‐connected PV power generation system mainly includes three aspects: technology, economy, and environment. The results show that the performance ratio of grid‐connected PV system with dual‐axis tracking device is the highest among the five kinds of PV systems with a value of 81.2%, while the performance ratio of grid‐connected PV system without tracking device is the lowest with a value of 77.3%. The grid‐connected PV system with dual‐axis tracking device is economically attractive, so users can be encouraged to purchase and install such systems to meet their electrical energy needs in Hefei. Furthermore, the grid‐connected PV system with dual‐axis tracking device is the most environmentally friendly and contributes to carbon emission reduction. Finally, it is concluded that the adoption of dual‐axis tracking grid‐connected PV power generation system in Hefei area is very attractive, and can provide a certain reference for the local promotion and use of such grid‐connected PV power generation system.
- 10 November 2023
- Published by Wiley in Energy Technology
- Vol. 12 (2)
Technical, Economic, and Environmental Feasibility Assessment of Grid‐Connected Photovoltaic Power Generation Systems with Different Tracking Models in Hefei, China
Herein, the feasibility of a grid‐connected photovoltaic (PV) power generation system with five tracking models in Hefei is evaluated comprehensively. The comprehensive evaluation of grid‐connected PV power generation system mainly includes three aspects: technology, economy, and environment. The results show that the performance ratio of grid‐connected PV system with dual‐axis tracking device is the highest among the five kinds of PV systems with a value of 81.2%, while the performance ratio of grid‐connected PV system without tracking device is the lowest with a value of 77.3%. The grid‐connected PV system with dual‐axis tracking device is economically attractive, so users can be encouraged to purchase and install such systems to meet their electrical energy needs in Hefei. Furthermore, the grid‐connected PV system with dual‐axis tracking device is the most environmentally friendly and contributes to carbon emission reduction. Finally, it is concluded that the adoption of dual‐axis tracking grid‐connected PV power generation system in Hefei area is very attractive, and can provide a certain reference for the local promotion and use of such grid‐connected PV power generation system.
- Open Access
- 23 February 2021
- Published by Springer Nature in Research Square
Assessment of survival potential of four grid-connected solar photovoltaic power stations in Jiangsu Province, China
The aim of this study is to analyze the feasibility of the construction of 1-MW grid-connected solar photovoltaic (GCSPV) power stations at four locations of Jiangsu province, China. The economic, emission, sensitivity and risk analyses of the proposed systems are all performed using the RETScreen clean energy management software. The GCSPV system in Xuzhou is more economically viable than those in other regions under consideration, while this system in Nanjing is relatively less economically viable. The GCSPV power stations in Xuzhou have the largest annual Greenhouse gases (GHG) emissions reduction due to its largest electricity production from the proposed system. The sensitivity analysis results on NPV show significant variations due to the variations of electricity export rate (EER) and initial costs (ICs) parameters. The NPV of the proposed system increases from 707,589 $ to 2,046,766 $ with the increase of the EER, while the NPV of the system decreases with the increase of the ICs at the same of EER. The risk analysis shows the largest influence on the NPV of the project is the change of the EER with positive correlation, while the least impact on the NPV is the debt term with positive correlation.- 23 February 2021
- Published by Springer Nature in Research Square
Open AccessAssessment of survival potential of four grid-connected solar photovoltaic power stations in Jiangsu Province, China
The aim of this study is to analyze the feasibility of the construction of 1-MW grid-connected solar photovoltaic (GCSPV) power stations at four locations of Jiangsu province, China. The economic, emission, sensitivity and risk analyses of the proposed systems are all performed using the RETScreen clean energy management software. The GCSPV system in Xuzhou is more economically viable than those in other regions under consideration, while this system in Nanjing is relatively less economically viable. The GCSPV power stations in Xuzhou have the largest annual Greenhouse gases (GHG) emissions reduction due to its largest electricity production from the proposed system. The sensitivity analysis results on NPV show significant variations due to the variations of electricity export rate (EER) and initial costs (ICs) parameters. The NPV of the proposed system increases from 707,589 $ to 2,046,766 $ with the increase of the EER, while the NPV of the system decreases with the increase of the ICs at the same of EER. The risk analysis shows the largest influence on the NPV of the project is the change of the EER with positive correlation, while the least impact on the NPV is the debt term with positive correlation. - 2 December 2020
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 18 (3) , 258-270
Technical and economic potential evaluation of an off-grid hybrid wind-fuel cell-battery energy system in Xining, China
This study proposes a technical and economic evaluation of a stand-alone wind-fuel cell (FC)-battery hybrid energy system for a residential house in Xining, China. The techno-economic analysis of the two different systems including the wind-battery and wind-fuel cell-battery systems has been conducted by employing HOMER (Hybrid Optimization Model for Electric Renewables) software. The optimal allocation of the system types, cash flows, operating conditions, power generation, and sensitivity analysis have all been discussed. The results indicate that the optimal wind-battery hybrid system is more economical, when compared to the wind-FC-battery system, for a house in Xining. The power generation costs of these two energy systems are comparable, which also provides a possibility for the use of wind-FC-battery hybrid power system. Although the wind-FC-battery system is currently expensive, it is an important method to produce hydrogen, which facilitates the widespread use of hydrogen FC vehicles. The wind-battery and wind-FC-battery hybrid energy systems can adequately meet the load requirements for the considered house. The excess electricity from the wind-FC-battery system is less than the wind-battery system, since a portion of the surplus electricity is utilized to electrolyze the water to produce hydrogen.
- 2 December 2020
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 18 (3) , 258-270
Technical and economic potential evaluation of an off-grid hybrid wind-fuel cell-battery energy system in Xining, China
This study proposes a technical and economic evaluation of a stand-alone wind-fuel cell (FC)-battery hybrid energy system for a residential house in Xining, China. The techno-economic analysis of the two different systems including the wind-battery and wind-fuel cell-battery systems has been conducted by employing HOMER (Hybrid Optimization Model for Electric Renewables) software. The optimal allocation of the system types, cash flows, operating conditions, power generation, and sensitivity analysis have all been discussed. The results indicate that the optimal wind-battery hybrid system is more economical, when compared to the wind-FC-battery system, for a house in Xining. The power generation costs of these two energy systems are comparable, which also provides a possibility for the use of wind-FC-battery hybrid power system. Although the wind-FC-battery system is currently expensive, it is an important method to produce hydrogen, which facilitates the widespread use of hydrogen FC vehicles. The wind-battery and wind-FC-battery hybrid energy systems can adequately meet the load requirements for the considered house. The excess electricity from the wind-FC-battery system is less than the wind-battery system, since a portion of the surplus electricity is utilized to electrolyze the water to produce hydrogen.
- 20 September 2019
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 44 (2) , 5473-5489
Economic and performance evaluation of grid-connected residential solar photovoltaic systems in Northwest China
The purpose of the study is to assess and compare the economy and performance of a hypothetical 5 kWp grid-connected residential solar photovoltaic (PV) system with and without batteries in Northwest China. The performance and economic analysis of the grid-connected residential PV system in five different locations (Xi’an, Lanzhou, Xining, Yinchuan, and Urumqi) of Northwest China has been performed through System Advisor Model (SAM) software developed by National Renewable Energy Laboratory (NREL) using the typical meteorological year (TMY) data of EnergyPlus weather database. The results indicate that the feasible system comprises 16 Shanghai JA Solar Technology JAM6-72-275 mono-crystalline modules rated at 275Wp, two GCI-3K-2G-H inverters rated at 2,990 W, and without flooded lead acid battery storage. The grid-connected PV systems are economically viable in the five locations, whereas the grid-connect PV/battery systems are not viable under the existing assumptions. The loan term has the greatest impact on the real LCOE and NPV compared to the considered sensitivity variables when the range of variation is within ±20%.
- 20 September 2019
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 44 (2) , 5473-5489
Economic and performance evaluation of grid-connected residential solar photovoltaic systems in Northwest China
The purpose of the study is to assess and compare the economy and performance of a hypothetical 5 kWp grid-connected residential solar photovoltaic (PV) system with and without batteries in Northwest China. The performance and economic analysis of the grid-connected residential PV system in five different locations (Xi’an, Lanzhou, Xining, Yinchuan, and Urumqi) of Northwest China has been performed through System Advisor Model (SAM) software developed by National Renewable Energy Laboratory (NREL) using the typical meteorological year (TMY) data of EnergyPlus weather database. The results indicate that the feasible system comprises 16 Shanghai JA Solar Technology JAM6-72-275 mono-crystalline modules rated at 275Wp, two GCI-3K-2G-H inverters rated at 2,990 W, and without flooded lead acid battery storage. The grid-connected PV systems are economically viable in the five locations, whereas the grid-connect PV/battery systems are not viable under the existing assumptions. The loan term has the greatest impact on the real LCOE and NPV compared to the considered sensitivity variables when the range of variation is within ±20%.
- 19 November 2018
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 41 (13) , 1588-1604
Techno-economic study of off-grid hybrid photovoltaic/battery and photovoltaic/battery/fuel cell power systems in Kunming, China
The objective of this study is to evaluate the technical and economic feasibility of stand-alone hybrid photovoltaic (PV)/battery and PV/battery/fuel cell (FC) power systems for a community center comprising 100 households in Kunming by using the Hybrid Optimization Model for Electric Renewable (HOMER) software. HOMER is used to define the optimum sizing and techno-economic feasibility of the system equipment based on the geographical and meteorological data of the study region. In this study, different hybrid power systems are analyzed to select the optimum energy system while considering total net present cost (NPC) and levelized cost of energy (COE). The results showed that the optimal hybrid PV/battery system comprised 500 kW PV modules, 1200 7.6-kWh battery units, and 500 kW power converters. The proposed system has an initial cost of $6,670,000, an annual operating cost of $82,763/yr, a total NPC of $7,727,992, and a levelized COE of $1.536/kWh. While the PV/battery/FC power system is possible, the cost increases were due to the investment cost of the FC system. The optimal PV/battery/FC system has an initial cost of $6,763,000, an annual operating cost of $82,312/yr, a total NPC of $7,815,223, and a levelized COE of $1.553/kWh.
- 19 November 2018
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 41 (13) , 1588-1604
Techno-economic study of off-grid hybrid photovoltaic/battery and photovoltaic/battery/fuel cell power systems in Kunming, China
The objective of this study is to evaluate the technical and economic feasibility of stand-alone hybrid photovoltaic (PV)/battery and PV/battery/fuel cell (FC) power systems for a community center comprising 100 households in Kunming by using the Hybrid Optimization Model for Electric Renewable (HOMER) software. HOMER is used to define the optimum sizing and techno-economic feasibility of the system equipment based on the geographical and meteorological data of the study region. In this study, different hybrid power systems are analyzed to select the optimum energy system while considering total net present cost (NPC) and levelized cost of energy (COE). The results showed that the optimal hybrid PV/battery system comprised 500 kW PV modules, 1200 7.6-kWh battery units, and 500 kW power converters. The proposed system has an initial cost of $6,670,000, an annual operating cost of $82,763/yr, a total NPC of $7,727,992, and a levelized COE of $1.536/kWh. While the PV/battery/FC power system is possible, the cost increases were due to the investment cost of the FC system. The optimal PV/battery/FC system has an initial cost of $6,763,000, an annual operating cost of $82,312/yr, a total NPC of $7,815,223, and a levelized COE of $1.553/kWh.
- Open Access
- 14 October 2018
- Published by Wiley in International Journal of Photoenergy
- Vol. 2018, 1-9
Comparative Performance Analysis of Grid-Connected PV Power Systems with Different PV Technologies in the Hot Summer and Cold Winter Zone
The objective of this paper is to establish the performance of 8 kWp grid-connected photovoltaic (PV) power systems based on different PV module technologies in Nanjing, China. Nanjing has a hot summer and a cold winter which are considered based on monthly average solar irradiation and ambient temperature specifically for the deployment of grid-connected PV systems. The study focuses on performance assessment of grid-connected PV systems using typical PV modules made of monocrystalline silicon (m-Si), polycrystalline silicon (p-Si), edge-defined film-fed growth silicon (EFG-Si), cadmium telluride (CdTe) thin film, copper indium selenide (CIS) thin film, heterojunction with intrinsic thin layer (HIT), and hydrogenated amorphous silicon single-junction (a-Si:H single-PV) installed on location. The yearly average energy output, PV module and system efficiency, array yield, final yield, reference yield, performance ratio, monthly average array capture losses, and system losses of seven PV module technologies are all analyzed. The results show that grid-connected PV power system performance depends on geographical location, PV module types, and climate conditions such as solar radiation and ambient temperature. In addition, based on energy output and efficiency, the HIT PV power technology can be considered as the best option and CdTe and p-Si as the least suitable options for this area. The monthly average performance ratio of the CdTe technology was higher than those of other technologies over the monitoring period in Nanjing.
- 14 October 2018
- Published by Wiley in International Journal of Photoenergy
- Vol. 2018, 1-9
Open AccessComparative Performance Analysis of Grid-Connected PV Power Systems with Different PV Technologies in the Hot Summer and Cold Winter Zone
The objective of this paper is to establish the performance of 8 kWp grid-connected photovoltaic (PV) power systems based on different PV module technologies in Nanjing, China. Nanjing has a hot summer and a cold winter which are considered based on monthly average solar irradiation and ambient temperature specifically for the deployment of grid-connected PV systems. The study focuses on performance assessment of grid-connected PV systems using typical PV modules made of monocrystalline silicon (m-Si), polycrystalline silicon (p-Si), edge-defined film-fed growth silicon (EFG-Si), cadmium telluride (CdTe) thin film, copper indium selenide (CIS) thin film, heterojunction with intrinsic thin layer (HIT), and hydrogenated amorphous silicon single-junction (a-Si:H single-PV) installed on location. The yearly average energy output, PV module and system efficiency, array yield, final yield, reference yield, performance ratio, monthly average array capture losses, and system losses of seven PV module technologies are all analyzed. The results show that grid-connected PV power system performance depends on geographical location, PV module types, and climate conditions such as solar radiation and ambient temperature. In addition, based on energy output and efficiency, the HIT PV power technology can be considered as the best option and CdTe and p-Si as the least suitable options for this area. The monthly average performance ratio of the CdTe technology was higher than those of other technologies over the monitoring period in Nanjing.
- Open Access
- 29 July 2016
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 67, 06035
Prediction of Tensile Strength of Nano-short-fiber-reinforced Rubber Composites
- 29 July 2016
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 67, 06035
Open AccessPrediction of Tensile Strength of Nano-short-fiber-reinforced Rubber Composites