Levi Madden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Levi Madden has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Anatoly B. Rosenfeld
Centre for Medical Radiation Physics, University of Wollongong
6 shared publications - Enbang Li
School of Mathematics and Physics, University of Wollongong, Wollongong, NSW 2522, Australia
6 shared publications - James Archer
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2522, Australia
5 shared publications Anatoly Rosenfeld
3 shared publicationsBin Dong
Ingham Institute for Applied Medica, 1 Campbell St, Liverpool, New South Wales, 2170, AUSTRALIA
3 shared publications- Dean Wilkinson
Illawarra Cancer Care Centre, Wollongong Hospital, Wollongong, NSW, 2500, Australia
3 shared publications
Latest Publications
- 26 April 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (3) , 035039
CBCT-DRRs superior to CT-DRRs for target-tracking applications for pancreatic SBRT
Objective. In current radiograph-based intra-fraction markerless target-tracking, digitally reconstructed radiographs (DRRs) from planning CTs (CT-DRRs) are often used to train deep learning models that extract information from the intra-fraction radiographs acquired during treatment. Traditional DRR algorithms were designed for patient alignment (i.e. bone matching) and may not replicate the radiographic image quality of intra-fraction radiographs at treatment. Hypothetically, generating DRRs from pre-treatment Cone-Beam CTs (CBCT-DRRs) with DRR algorithms incorporating physical modelling of on-board-imagers (OBIs) could improve the similarity between intra-fraction radiographs and DRRs by eliminating inter-fraction variation and reducing image-quality mismatches between radiographs and DRRs. In this study, we test the two hypotheses that intra-fraction radiographs are more similar to CBCT-DRRs than CT-DRRs, and that intra-fraction radiographs are more similar to DRRs from algorithms incorporating physical models of OBI components than DRRs from algorithms omitting these models. Approach. DRRs were generated from CBCT and CT image sets collected from 20 patients undergoing pancreas stereotactic body radiotherapy. CBCT-DRRs and CT-DRRs were generated replicating the treatment position of patients and the OBI geometry during intra-fraction radiograph acquisition. To investigate whether the modelling of physical OBI components influenced radiograph-DRR similarity, four DRR algorithms were applied for the generation of CBCT-DRRs and CT-DRRs, incorporating and omitting different combinations of OBI component models. The four DRR algorithms were: a traditional DRR algorithm, a DRR algorithm with source-spectrum modelling, a DRR algorithm with source-spectrum and detector modelling, and a DRR algorithm with source-spectrum, detector and patient material modelling. Similarity between radiographs and matched DRRs was quantified using Pearson’s correlation and Czekanowski’s index, calculated on a per-image basis. Distributions of correlations and indexes were compared to test each of the hypotheses. Distribution differences were determined to be statistically significant when Wilcoxon’s signed rank test and the Kolmogorov-Smirnov two sample test returned p ≤ 0.05 for both tests. Main results. Intra-fraction radiographs were more similar to CBCT-DRRs than CT-DRRs for both metrics across all algorithms, with all p ≤ 0.007. Source-spectrum modelling improved radiograph-DRR similarity for both metrics, with all p < 10−6. OBI detector modelling and patient material modelling did not influence radiograph-DRR similarity for either metric. Significance. Generating DRRs from pre-treatment CBCT-DRRs is feasible, and incorporating CBCT-DRRs into markerless target-tracking methods may promote improved target-tracking accuracies. Incorporating source-spectrum modelling into a treatment planning system’s DRR algorithms may reinforce the safe treatment of cancer patients by aiding in patient alignment.
- 26 April 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (3) , 035039
CBCT-DRRs superior to CT-DRRs for target-tracking applications for pancreatic SBRT
Objective. In current radiograph-based intra-fraction markerless target-tracking, digitally reconstructed radiographs (DRRs) from planning CTs (CT-DRRs) are often used to train deep learning models that extract information from the intra-fraction radiographs acquired during treatment. Traditional DRR algorithms were designed for patient alignment (i.e. bone matching) and may not replicate the radiographic image quality of intra-fraction radiographs at treatment. Hypothetically, generating DRRs from pre-treatment Cone-Beam CTs (CBCT-DRRs) with DRR algorithms incorporating physical modelling of on-board-imagers (OBIs) could improve the similarity between intra-fraction radiographs and DRRs by eliminating inter-fraction variation and reducing image-quality mismatches between radiographs and DRRs. In this study, we test the two hypotheses that intra-fraction radiographs are more similar to CBCT-DRRs than CT-DRRs, and that intra-fraction radiographs are more similar to DRRs from algorithms incorporating physical models of OBI components than DRRs from algorithms omitting these models. Approach. DRRs were generated from CBCT and CT image sets collected from 20 patients undergoing pancreas stereotactic body radiotherapy. CBCT-DRRs and CT-DRRs were generated replicating the treatment position of patients and the OBI geometry during intra-fraction radiograph acquisition. To investigate whether the modelling of physical OBI components influenced radiograph-DRR similarity, four DRR algorithms were applied for the generation of CBCT-DRRs and CT-DRRs, incorporating and omitting different combinations of OBI component models. The four DRR algorithms were: a traditional DRR algorithm, a DRR algorithm with source-spectrum modelling, a DRR algorithm with source-spectrum and detector modelling, and a DRR algorithm with source-spectrum, detector and patient material modelling. Similarity between radiographs and matched DRRs was quantified using Pearson’s correlation and Czekanowski’s index, calculated on a per-image basis. Distributions of correlations and indexes were compared to test each of the hypotheses. Distribution differences were determined to be statistically significant when Wilcoxon’s signed rank test and the Kolmogorov-Smirnov two sample test returned p ≤ 0.05 for both tests. Main results. Intra-fraction radiographs were more similar to CBCT-DRRs than CT-DRRs for both metrics across all algorithms, with all p ≤ 0.007. Source-spectrum modelling improved radiograph-DRR similarity for both metrics, with all p < 10−6. OBI detector modelling and patient material modelling did not influence radiograph-DRR similarity for either metric. Significance. Generating DRRs from pre-treatment CBCT-DRRs is feasible, and incorporating CBCT-DRRs into markerless target-tracking methods may promote improved target-tracking accuracies. Incorporating source-spectrum modelling into a treatment planning system’s DRR algorithms may reinforce the safe treatment of cancer patients by aiding in patient alignment.
- 7 March 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (3) , 035008
Evaluation of deep learning based implanted fiducial markers tracking in pancreatic cancer patients
Real-time target position verification during pancreas stereotactic body radiation therapy (SBRT) is important for the detection of unplanned tumour motions. Fast and accurate fiducial marker segmentation is a Requirement of real-time marker-based verification. Deep learning (DL) segmentation techniques are ideal because they don’t require additional learning imaging or prior marker information (e.g., shape, orientation). In this study, we evaluated three DL frameworks for marker tracking applied to pancreatic cancer patient data. The DL frameworks evaluated were (1) a convolutional neural network (CNN) classifier with sliding window, (2) a pretrained you-only-look-once (YOLO) version-4 architecture, and (3) a hybrid CNN-YOLO. Intrafraction kV images collected during pancreas SBRT treatments were used as training data (44 fractions, 2017 frames). All patients had 1-4 implanted fiducial markers. Each model was evaluated on unseen kV images (42 fractions, 2517 frames). The ground truth was calculated from manual segmentation and triangulation of markers in orthogonal paired kV/MV images. The sensitivity, specificity, and area under the precision-recall curve (AUC) were calculated. In addition, the mean-absolute-error (MAE), root-mean-square-error (RMSE) and standard-error-of-mean (SEM) were calculated for the centroid of the markers predicted by the models, relative to the ground truth. The sensitivity and specificity of the CNN model were 99.41% and 99.69%, respectively. The AUC was 0.9998. The average precision of the YOLO model for different values of recall was 96.49%. The MAE of the three models in the left-right, superior-inferior, and anterior-posterior directions were under 0.88 ± 0.11 mm, and the RMSE were under 1.09 ± 0.12 mm. The detection times per frame on a GPU were 48.3, 22.9, and 17.1 milliseconds for the CNN, YOLO, and CNN-YOLO, respectively. The results demonstrate submillimeter accuracy of marker position predicted by DL models compared to the ground truth. The marker detection time was fast enough to meet the requirements for real-time application.
- 7 March 2023
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (3) , 035008
Evaluation of deep learning based implanted fiducial markers tracking in pancreatic cancer patients
Real-time target position verification during pancreas stereotactic body radiation therapy (SBRT) is important for the detection of unplanned tumour motions. Fast and accurate fiducial marker segmentation is a Requirement of real-time marker-based verification. Deep learning (DL) segmentation techniques are ideal because they don’t require additional learning imaging or prior marker information (e.g., shape, orientation). In this study, we evaluated three DL frameworks for marker tracking applied to pancreatic cancer patient data. The DL frameworks evaluated were (1) a convolutional neural network (CNN) classifier with sliding window, (2) a pretrained you-only-look-once (YOLO) version-4 architecture, and (3) a hybrid CNN-YOLO. Intrafraction kV images collected during pancreas SBRT treatments were used as training data (44 fractions, 2017 frames). All patients had 1-4 implanted fiducial markers. Each model was evaluated on unseen kV images (42 fractions, 2517 frames). The ground truth was calculated from manual segmentation and triangulation of markers in orthogonal paired kV/MV images. The sensitivity, specificity, and area under the precision-recall curve (AUC) were calculated. In addition, the mean-absolute-error (MAE), root-mean-square-error (RMSE) and standard-error-of-mean (SEM) were calculated for the centroid of the markers predicted by the models, relative to the ground truth. The sensitivity and specificity of the CNN model were 99.41% and 99.69%, respectively. The AUC was 0.9998. The average precision of the YOLO model for different values of recall was 96.49%. The MAE of the three models in the left-right, superior-inferior, and anterior-posterior directions were under 0.88 ± 0.11 mm, and the RMSE were under 1.09 ± 0.12 mm. The detection times per frame on a GPU were 48.3, 22.9, and 17.1 milliseconds for the CNN, YOLO, and CNN-YOLO, respectively. The results demonstrate submillimeter accuracy of marker position predicted by DL models compared to the ground truth. The marker detection time was fast enough to meet the requirements for real-time application.
- 1 December 2021
- Published by Elsevier in Radiation Measurements
- Vol. 149
Deconvolution analysis improves real-time OSL of BeO ceramic
- 1 December 2021
- Published by Elsevier in Radiation Measurements
- Vol. 149
Deconvolution analysis improves real-time OSL of BeO ceramic
- 11 February 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (2) , 025012
In-line MRI-LINAC depth dose measurements using an in-house plastic scintillation dosimeter
Plastic scintillation dosimeters (PSDs) have many properties that make them desirable for relative dosimetry with MRI-LINACs. An in-house PSD, Farmer ionisation chamber and Gafchromic EBT3 film were used to measure central axis percentage depth dose distributions (PDDs) at the Australian MRI-LINAC Mean errors were calculated between each detector’s responses, where the in-house PSD was on average within 0.7% of the Farmer chamber and 1.4% of film, while the Farmer chamber and film were on average within 1.1% of each other. However, the PSD systematically over-estimated the dose as depth increased, approaching a maximum overestimation of the order of 3.5% for the smallest field size measured. This trend was statistically insignificant for all other field sizes measured; further investigation is required to determine the source of this effect. The calculated values of mean absolute error are comparable to the those of trusted dosimeters reported in the literature. These mean absolute errors, and the ubiquity of desirable dosimetric qualities inherent to PSDs suggest that PSDs in general are accurate for relative dosimetry with the MRI-LINAC. Further investigation is required into the source of the reported systematic trends dependent on field-size and depth of measurement.
- 11 February 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (2) , 025012
In-line MRI-LINAC depth dose measurements using an in-house plastic scintillation dosimeter
Plastic scintillation dosimeters (PSDs) have many properties that make them desirable for relative dosimetry with MRI-LINACs. An in-house PSD, Farmer ionisation chamber and Gafchromic EBT3 film were used to measure central axis percentage depth dose distributions (PDDs) at the Australian MRI-LINAC Mean errors were calculated between each detector’s responses, where the in-house PSD was on average within 0.7% of the Farmer chamber and 1.4% of film, while the Farmer chamber and film were on average within 1.1% of each other. However, the PSD systematically over-estimated the dose as depth increased, approaching a maximum overestimation of the order of 3.5% for the smallest field size measured. This trend was statistically insignificant for all other field sizes measured; further investigation is required to determine the source of this effect. The calculated values of mean absolute error are comparable to the those of trusted dosimeters reported in the literature. These mean absolute errors, and the ubiquity of desirable dosimetric qualities inherent to PSDs suggest that PSDs in general are accurate for relative dosimetry with the MRI-LINAC. Further investigation is required into the source of the reported systematic trends dependent on field-size and depth of measurement.
- 1 May 2020
- Published by Elsevier in Physica Medica
- Vol. 73, 111-116
MRI-LINAC beam profile measurements using a plastic scintillation dosimeter.
- 1 May 2020
- Published by Elsevier in Physica Medica
- Vol. 73, 111-116
MRI-LINAC beam profile measurements using a plastic scintillation dosimeter.
- 12 September 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 166, 108490
2D photon dosimetry with a scintillation fibre optic dosimeter
- 12 September 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 166, 108490
2D photon dosimetry with a scintillation fibre optic dosimeter
- 1 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (17) , 175015
First measurements with a plastic scintillation dosimeter at the Australian MRI-LINAC
MRI-LINACs combine MRI and LINAC technologies with the potential for image guided radiation therapy with optimal soft-tissue contrast. In this work, we present the advantages and limitations of plastic scintillation dosimeters (PSDs) for relative dosimetry with MRI-LINACs. PSDs possess many desirable qualities, including magnetic field insensitivity and irradiation angle independence, which are expected to make them suitable for dosimetry with MRI-LINACs. An in-house PSD was used to measure field size output factors as well as a percent depth dose distribution and the beam quality index TPR 20/10 at a cm 2 field size. Measurements were repeated with a Scanditronix/Wellhofer FC65-G ionisation chamber and PTW 60019 microDiamond detector for comparison. Relative differences were calculated between the three detectors, where the mean difference in dose was 1.2% between the PSD and ionisation chamber, 1.9% between the PSD and microDiamond detector and 1.3% between the microDiamond detector and the ionisation chamber. The closeness between the three mean differences in doses suggests that PSDs are feasible for relative dosimetry with MRI-LINACs.
- 1 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (17) , 175015
First measurements with a plastic scintillation dosimeter at the Australian MRI-LINAC
MRI-LINACs combine MRI and LINAC technologies with the potential for image guided radiation therapy with optimal soft-tissue contrast. In this work, we present the advantages and limitations of plastic scintillation dosimeters (PSDs) for relative dosimetry with MRI-LINACs. PSDs possess many desirable qualities, including magnetic field insensitivity and irradiation angle independence, which are expected to make them suitable for dosimetry with MRI-LINACs. An in-house PSD was used to measure field size output factors as well as a percent depth dose distribution and the beam quality index TPR 20/10 at a cm 2 field size. Measurements were repeated with a Scanditronix/Wellhofer FC65-G ionisation chamber and PTW 60019 microDiamond detector for comparison. Relative differences were calculated between the three detectors, where the mean difference in dose was 1.2% between the PSD and ionisation chamber, 1.9% between the PSD and microDiamond detector and 1.3% between the microDiamond detector and the ionisation chamber. The closeness between the three mean differences in doses suggests that PSDs are feasible for relative dosimetry with MRI-LINACs.
- 1 November 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (22) , 225004
Temporal separation of Cerenkov radiation and scintillation using a clinical LINAC and artificial intelligence
Convolutional neural network (CNN) type artificial intelligences were trained to estimate the Cerenkov radiation present in the temporal response of a LINAC irradiated scintillator-fiber optic dosimeter. The CNN estimate of Cerenkov radiation is subtracted from the combined scintillation and Cerenkov radiation temporal response of the irradiated scintillator-fiber optic dosimeter, giving the sole scintillation signal, which is proportional to the scintillator dose. The CNN measured scintillator dose was compared to the background subtraction measured scintillator dose and ionisation chamber measured dose. The dose discrepancy of the CNN measured dose was on average 1.4% with respect to the ionisation chamber measured dose, matching the 1.4% average dose discrepancy of the background subtraction measured dose with respect to the ionisation chamber measured dose. The developed CNNs had an average time of 3 ms to calculate scintillator dose, permitting the CNNs presented to be applicable for dosimetry in real time.
- 1 November 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (22) , 225004
Temporal separation of Cerenkov radiation and scintillation using a clinical LINAC and artificial intelligence
Convolutional neural network (CNN) type artificial intelligences were trained to estimate the Cerenkov radiation present in the temporal response of a LINAC irradiated scintillator-fiber optic dosimeter. The CNN estimate of Cerenkov radiation is subtracted from the combined scintillation and Cerenkov radiation temporal response of the irradiated scintillator-fiber optic dosimeter, giving the sole scintillation signal, which is proportional to the scintillator dose. The CNN measured scintillator dose was compared to the background subtraction measured scintillator dose and ionisation chamber measured dose. The dose discrepancy of the CNN measured dose was on average 1.4% with respect to the ionisation chamber measured dose, matching the 1.4% average dose discrepancy of the background subtraction measured dose with respect to the ionisation chamber measured dose. The developed CNNs had an average time of 3 ms to calculate scintillator dose, permitting the CNNs presented to be applicable for dosimetry in real time.
- 1 October 2018
- Published by Elsevier in Physica Medica
- Vol. 54, 131-136
Temporal separation of Cerenkov radiation and scintillation using artificial neural networks in Clinical LINACs
- 1 October 2018
- Published by Elsevier in Physica Medica
- Vol. 54, 131-136
Temporal separation of Cerenkov radiation and scintillation using artificial neural networks in Clinical LINACs
- 1 July 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 044003
A comparison of temporal Cherenkov separation techniques in pulsed signal scintillator dosimetry
Cherenkov radiation is the primary source of unwanted light in a scintillator dosimetry system. In this work we compare two techniques for temporally separating Cherenkov radiation from a slow scintillator signal. These techniques are applicable to a pulsed radiation beam. We found that by analysing the rising edge of the light pulse to identify the fast Cherenkov light only removed 74% of the Cherenkov light. By integrating the tail of the signal where only scintillation light is present a more accurate result is achieved. The average of the results of the two methods provides up to a 90% improvement in the accuracy of the relative dose when compared to ionisation chamber, in certain measurements. This work demonstrates an alternative methodology for the removal of Cherenkov light using signal analysis, while preserving all the scintillation light signal and minimising the bulk of the experimental equipment.
- 1 July 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 044003
A comparison of temporal Cherenkov separation techniques in pulsed signal scintillator dosimetry
Cherenkov radiation is the primary source of unwanted light in a scintillator dosimetry system. In this work we compare two techniques for temporally separating Cherenkov radiation from a slow scintillator signal. These techniques are applicable to a pulsed radiation beam. We found that by analysing the rising edge of the light pulse to identify the fast Cherenkov light only removed 74% of the Cherenkov light. By integrating the tail of the signal where only scintillation light is present a more accurate result is achieved. The average of the results of the two methods provides up to a 90% improvement in the accuracy of the relative dose when compared to ionisation chamber, in certain measurements. This work demonstrates an alternative methodology for the removal of Cherenkov light using signal analysis, while preserving all the scintillation light signal and minimising the bulk of the experimental equipment.