Imran Deen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Imran Deen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
I. Zhitomirsky
3 shared publications- Muthukumaran Packirisamy
Concordia University
2 shared publications - D. Landheer
Institute for Microstructural Sciences, National Research Council, Ottawa, Ontario, Canada K1A 0R6
1 shared publication - David Zhitomirsky
McMaster University, Hamilton, ON L8S 4K1 Canada
1 shared publication - Dhilippan Mamsapuram Panneerselvam
Optical-Bio Microsystems Laboratory, Micro-Nano-Bio Integration Center, Department of Mechanical, Industrial and Aerospace Engineering, Concordia University, Montreal, QC H3G 1M8, Canada
1 shared publication - Federico Rosei
University of Trieste Via Giorgeri 1
1 shared publication
Latest Publications
- Open Access
- 12 December 2025
- Published by Springer Nature in Discover Electronics
- Vol. 2 (1)
Improved electrical performance of PDMS and PEDOT: PSS composites with MWCNT and AgNP particles
The online version contains supplementary material available at 10.1007/s44291-025-00136-0. The online version contains supplementary material available at 10.1007/s44291-025-00136-0.
- 12 December 2025
- Published by Springer Nature in Discover Electronics
- Vol. 2 (1)
Open AccessImproved electrical performance of PDMS and PEDOT: PSS composites with MWCNT and AgNP particles
The online version contains supplementary material available at 10.1007/s44291-025-00136-0. The online version contains supplementary material available at 10.1007/s44291-025-00136-0.
- Open Access
- 27 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 382
PEDOT:PSS-MWCNT Nanocomposite Wire for Routing in Energy Harvesting Devices
Polydimethylsiloxane (PDMS) and poly(3,4-ethylene dioxythiophene):poly(4-styrene-sulfonate) (PEDOT:PSS) composites were tested to determine their suitability for charging small-scale batteries in conjunction with a piezoelectric actuator as an energy harvester. Two different PEDOT:PSS patterns (zigzag and serpentine) were tested, and the maximum DC voltage of a system incorporating PEDOT:PSS was determined. The aim of this work is to study the effect of soft corners in the electrical routing of aircraft and IoT sensors. The zigzag and serpentine patterns were considered for this study because of their simplicity in design. Without the polymer, 2.3 V was produced by the actuator, while adding PEDOT:PSS resulted in the voltage being reduced to 1.7 V. The piezoelectric actuator was connected to a 3.6 V rechargeable Li-ion battery, and the battery’s voltage was recorded over 1 h. The voltage from the piezoelectric actuator was 3.8 V. Without PEDOT:PSS, the battery was charged to a maximum of 3 V. Adding the PEDOT:PSS to the circuit reduced the maximum charge to a voltage of 2 V. The results indicate that while PEDOT:PSS composites can be used in conjunction with piezoelectric energy harvesters, more work is still needed to optimize the system to increase efficiency and charging rates.
- 27 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 382
Open AccessPEDOT:PSS-MWCNT Nanocomposite Wire for Routing in Energy Harvesting Devices
Polydimethylsiloxane (PDMS) and poly(3,4-ethylene dioxythiophene):poly(4-styrene-sulfonate) (PEDOT:PSS) composites were tested to determine their suitability for charging small-scale batteries in conjunction with a piezoelectric actuator as an energy harvester. Two different PEDOT:PSS patterns (zigzag and serpentine) were tested, and the maximum DC voltage of a system incorporating PEDOT:PSS was determined. The aim of this work is to study the effect of soft corners in the electrical routing of aircraft and IoT sensors. The zigzag and serpentine patterns were considered for this study because of their simplicity in design. Without the polymer, 2.3 V was produced by the actuator, while adding PEDOT:PSS resulted in the voltage being reduced to 1.7 V. The piezoelectric actuator was connected to a 3.6 V rechargeable Li-ion battery, and the battery’s voltage was recorded over 1 h. The voltage from the piezoelectric actuator was 3.8 V. Without PEDOT:PSS, the battery was charged to a maximum of 3 V. Adding the PEDOT:PSS to the circuit reduced the maximum charge to a voltage of 2 V. The results indicate that while PEDOT:PSS composites can be used in conjunction with piezoelectric energy harvesters, more work is still needed to optimize the system to increase efficiency and charging rates.
- Open Access
- 15 July 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (7) , e0219429
Silk fibroin-derived polypeptides additives to promote hydroxyapatite nucleation in dense collagen hydrogels
Silk fibroin-derived polypeptides (FDPs) are polypeptides resulting from the enzymatic separation of the hydrophobic crystalline (Cp) and hydrophilic electronegative amorphous (Cs) components of silk fibroin (SF). The role of these polypeptides in promoting the nucleation of hydroxyapatite (HA) has been previously investigated, yet is still not fully understood. Here we study the potential of HA mineralization via FDPs incorporated at 1:10, 1:2 and 1:1 in a plastically compressed (PC) and dense collagen (DC) scaffold. Scaffolds were immersed in simulated body fluid (SBF) at physiological conditions (pH = 7.4, 37°C) to promote biomineralization. The effect of Cs and Cp to promote HA nucleation was investigated at different time points, and compared to pure DC scaffolds. Characterization of Cs and Cp fragments using Liquid Chromatography–Mass Spectrometry (LCMS) showed little difference in the amino acid composition of the FDPs. Results obtained in vitro using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR), Scanning Electron Microscopy (SEM) X-Ray Diffraction (XRD) and mass analysis showed little difference between scaffolds that incorporated Cs, Cp, and DC hydrogels. These results demonstrated that silk FDPs incorporation are not yet suitable to promote HA nucleation in vivo without further refining the collagen-FDP system.
- 15 July 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (7) , e0219429
Open AccessSilk fibroin-derived polypeptides additives to promote hydroxyapatite nucleation in dense collagen hydrogels
Silk fibroin-derived polypeptides (FDPs) are polypeptides resulting from the enzymatic separation of the hydrophobic crystalline (Cp) and hydrophilic electronegative amorphous (Cs) components of silk fibroin (SF). The role of these polypeptides in promoting the nucleation of hydroxyapatite (HA) has been previously investigated, yet is still not fully understood. Here we study the potential of HA mineralization via FDPs incorporated at 1:10, 1:2 and 1:1 in a plastically compressed (PC) and dense collagen (DC) scaffold. Scaffolds were immersed in simulated body fluid (SBF) at physiological conditions (pH = 7.4, 37°C) to promote biomineralization. The effect of Cs and Cp to promote HA nucleation was investigated at different time points, and compared to pure DC scaffolds. Characterization of Cs and Cp fragments using Liquid Chromatography–Mass Spectrometry (LCMS) showed little difference in the amino acid composition of the FDPs. Results obtained in vitro using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR), Scanning Electron Microscopy (SEM) X-Ray Diffraction (XRD) and mass analysis showed little difference between scaffolds that incorporated Cs, Cp, and DC hydrogels. These results demonstrated that silk FDPs incorporation are not yet suitable to promote HA nucleation in vivo without further refining the collagen-FDP system.
- 1 February 2014
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 586, S531-S534
Electrophoretic deposition of composite halloysite nanotube–hydroxyapatite–hyaluronic acid films
- 1 February 2014
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 586, S531-S534
Electrophoretic deposition of composite halloysite nanotube–hydroxyapatite–hyaluronic acid films
- 1 September 2012
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 410, 38-44
Electrophoretic deposition of composite chitosan–halloysite nanotube–hydroxyapatite films
- 1 September 2012
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 410, 38-44
Electrophoretic deposition of composite chitosan–halloysite nanotube–hydroxyapatite films
- 1 October 2011
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 362 (2) , 367-374
Electrophoretic deposition of polyacrylic acid and composite films containing nanotubes and oxide particles
- 1 October 2011
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 362 (2) , 367-374
Electrophoretic deposition of polyacrylic acid and composite films containing nanotubes and oxide particles
- Open Access
Microfabricated Reference Electrodes and their Biosensing Applications
Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices have several functional advantages including low cost, their ability to analyze smaller samples, faster analysis time, suitability for automation, and increased reliability and repeatability. Electrical based sensing methods that transduce biological or chemical signals into the electrical domain are a dominant part of the lab-on-chip devices. A vital part of any electrochemical sensing system is the reference electrode, which is a probe that is capable of measuring the potential on the solution side of an electrochemical interface. Research on miniaturization of this crucial component and analysis of the parameters that affect its performance, stability and lifetime, is sparse. In this paper, we present the basic electrochemistry and thermodynamics of these reference electrodes and illustrate the uses of reference electrodes in electrochemical and biological measurements. Different electrochemical systems that are used as reference electrodes will be presented, and an overview of some contemporary advances in electrode miniaturization and their performance will be provided.
Open AccessMicrofabricated Reference Electrodes and their Biosensing Applications
Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices have several functional advantages including low cost, their ability to analyze smaller samples, faster analysis time, suitability for automation, and increased reliability and repeatability. Electrical based sensing methods that transduce biological or chemical signals into the electrical domain are a dominant part of the lab-on-chip devices. A vital part of any electrochemical sensing system is the reference electrode, which is a probe that is capable of measuring the potential on the solution side of an electrochemical interface. Research on miniaturization of this crucial component and analysis of the parameters that affect its performance, stability and lifetime, is sparse. In this paper, we present the basic electrochemistry and thermodynamics of these reference electrodes and illustrate the uses of reference electrodes in electrochemical and biological measurements. Different electrochemical systems that are used as reference electrodes will be presented, and an overview of some contemporary advances in electrode miniaturization and their performance will be provided.