JunHee Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
JunHee Han has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Wansoo Nah
Sungkyunkwan University
2 shared publications - Doojin Lee
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
1 shared publication - Hosang Lee
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
1 shared publication - Jangbom Chai
Ajou University
1 shared publication - Jawad Yousaf
Abu Dhabi University
1 shared publication - Jeongeun Kim
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
1 shared publication
Latest Publications
- Open Access
- 23 November 2020
- Published by MDPI AG in Electronics
- Vol. 9 (11) , 1984
Quantitative Analysis of Insulator Degradation in a Single Layer Solenoid by Renormalization of the Transmission Parameter
In this paper, a novel method to quantitatively analyze insulator degradation in a single layer solenoid is proposed. The suggested method employs renormalization of scattering parameters to efficiently detect changes of permittivity in a degraded solenoid. Firstly, a transmission line model, including a locally degraded part in the insulator, was developed, and it was determined that the phase information of the transmission parameter was very informative to check the permittivity change in the transmission line. To check the workability of this idea in a solenoid, a 30-turn single-layer solenoid was designed and fabricated, and 51 degraded states for mimicking insulation deterioration in each turn were introduced by installing additional insulator rings, which increased local relative permittivity. The phase data of the measured transmission parameter turned out to be useful for quantifying changes of the insulator in the solenoid. To maximize the detectability, the measured scattering parameters were renormalized with different reference impedances, which was very useful for detecting degradation in the transmission parameter. In this paper, detailed procedures for quantitatively analyzing degradation of an insulator are proposed and we verify that the suggested renormalization technique is very promising for effectively evaluating the degradation of a solenoid.
- 23 November 2020
- Published by MDPI AG in Electronics
- Vol. 9 (11) , 1984
Open AccessQuantitative Analysis of Insulator Degradation in a Single Layer Solenoid by Renormalization of the Transmission Parameter
In this paper, a novel method to quantitatively analyze insulator degradation in a single layer solenoid is proposed. The suggested method employs renormalization of scattering parameters to efficiently detect changes of permittivity in a degraded solenoid. Firstly, a transmission line model, including a locally degraded part in the insulator, was developed, and it was determined that the phase information of the transmission parameter was very informative to check the permittivity change in the transmission line. To check the workability of this idea in a solenoid, a 30-turn single-layer solenoid was designed and fabricated, and 51 degraded states for mimicking insulation deterioration in each turn were introduced by installing additional insulator rings, which increased local relative permittivity. The phase data of the measured transmission parameter turned out to be useful for quantifying changes of the insulator in the solenoid. To maximize the detectability, the measured scattering parameters were renormalized with different reference impedances, which was very useful for detecting degradation in the transmission parameter. In this paper, detailed procedures for quantitatively analyzing degradation of an insulator are proposed and we verify that the suggested renormalization technique is very promising for effectively evaluating the degradation of a solenoid.
- Open Access
- 16 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 797
Near-Field Immunity Test Method for Fast Radiated Immunity Test Debugging of Automotive Electronics
This study presents a near-field immunity test (NFIT) method for the fast debugging of radiated susceptibility of industrial devices. The proposed approach is based on the development of an NFIT setup which comprises of developed near-field electric and magnetic field probes and device under test (DUT). The developed small-size and handy near-field testing probes inject the high electric (up to 1000 V/m) and magnetic (up to 2.4 A/m) fields on the DUT in the radar pulse ranges (1.2 to 1.4 GHz and 2.7 to 3.1 GHz) with the lower fed input power (up to 15 W) from the power amplifier in the developed NFIT setup. The proof of concept is validated with the successful near-field immunity debugging of an electric power steering (EPS) device used in the automotive industry with the developed NFIT setup. The radiated susceptibility debugging test results of developed NFIT method and conventional method of ISO 11452-2 test setup turned out to be close to each other for the tested DUT in immunity performance. The proposed procedure has advantages of industry usefulness with fast, handy, and cost-effective radiated immunity debugging of the DUT without the requirement of large antenna, high-power amplifiers, optical DUT connecting harness, and an anechoic chamber as needed in ISO 11452-2 standard setup for the debugging analysis.
- 16 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 797
Open AccessNear-Field Immunity Test Method for Fast Radiated Immunity Test Debugging of Automotive Electronics
This study presents a near-field immunity test (NFIT) method for the fast debugging of radiated susceptibility of industrial devices. The proposed approach is based on the development of an NFIT setup which comprises of developed near-field electric and magnetic field probes and device under test (DUT). The developed small-size and handy near-field testing probes inject the high electric (up to 1000 V/m) and magnetic (up to 2.4 A/m) fields on the DUT in the radar pulse ranges (1.2 to 1.4 GHz and 2.7 to 3.1 GHz) with the lower fed input power (up to 15 W) from the power amplifier in the developed NFIT setup. The proof of concept is validated with the successful near-field immunity debugging of an electric power steering (EPS) device used in the automotive industry with the developed NFIT setup. The radiated susceptibility debugging test results of developed NFIT method and conventional method of ISO 11452-2 test setup turned out to be close to each other for the tested DUT in immunity performance. The proposed procedure has advantages of industry usefulness with fast, handy, and cost-effective radiated immunity debugging of the DUT without the requirement of large antenna, high-power amplifiers, optical DUT connecting harness, and an anechoic chamber as needed in ISO 11452-2 standard setup for the debugging analysis.