DLDongyuan Liu

Dongyuan Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dongyuan Liu has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Physics-Guided and Data-Driven Conditional GAN Data Augmentation for Depth-Resolved Spatial Frequency Domain Imaging Optical Property Estimation: A Simulation-Based Comparative Study

    by Ghazala Arshad, Dongyuan Liu, Feng Gao

    Background: Spatial frequency domain imaging (SFDI) is a non-contact, wide-field optical imaging technique that quantifies tissue absorption (μₐ) and reduced scattering coefficients (μs′). Conventional SFDI provides depth-averaged 2D maps. Methods: This study presents a simulation-based framework for depth-resolved optical property estimation over five depth layers, including discrete 3D inclusions. The framework also includes a comparison of two conditional GAN (cGAN) designs for synthetic data augmentation. Monte Carlo simulation generated 1000 heterogeneous tissue samples, with μₐ and μs′ varied independently. Two cGANs with identical architectures were trained. The first was a physics-guided (PG-cGAN), with six physics-based loss terms; the second was a data-driven (DD-cGAN) with no physics losses. Each cGAN generated 5000 synthetic samples. A multi-output U-Net was trained on each synthetic dataset separately and evaluated on the same held-out set of 200 real MCX samples to assess downstream optical property estimation accuracy. Results: Synthetic augmentation significantly outperformed the real-only baseline, with DD-cGAN reducing μₐ error by 47.7% and μs′ reducing error by 34.6%, while PG-cGAN reduced μₐ error by 43.2% and μs′ error by 33.5% (Exp4: μₐ R2 = 0.9953, μs′ R2 = 0.9328; Exp9: μₐ R2 = 0.9957, μs′ R2 = 0.9325; ΔR2 < 0.002). Per-slice analysis showed that Exp 9 achieved lower μₐ in deep slices, whereas Exp 4 had advantages in superficial slices. The two synthetic datasets also demonstrated complementary strengths. DD-cGAN produced samples that are closer to the physics targets (DC–μs′ error: 4.9% vs. 28.4%), whereas the PG-cGAN achieved higher image fidelity (paired SSIM: 0.622 vs. 0.599). Both designs achieved equivalent cross-condition diversity (0.789 vs. 0.791). Independent validation on a different MCX dataset (500 samples, seed 2026) confirmed that the derived physics relationships were consistent within the simulated parameter range. Conclusions: Both cGANs designs demonstrate comparable downstream performance. DD-cGAN provides improved physical correlation fidelity, whereas PG-cGAN provides improved image fidelity. These comparisons have been demonstrated using in-distribution MCX test data. Clinical translation will require experimental validation on phantoms and ex vivo tissue samples.

  • Open Access

    Resolving layer-specific optical properties with time-shift inversion to mitigate crosstalk in continuous-wave fNIRS optical topography

    by Dongyuan Liu, Xiaomeng Wang, Tong Zhang, Limin Zhang, Feng Gao

    Functional near-infrared spectroscopy (fNIRS) enables portable, non-invasive monitoring of cerebral oxygenation, yet its quantitative accuracy in continuous-wave optical topography (CW-fNIRS-OT) is often constrained by conventional methods that rely on an empirical differential path length factor (DPF). The empirical DPF typically assumes homogeneous tissue and ignores the layered head structure as well as inter-subject anatomical variability. In this study, we overcome the DPF-induced quantitative limitations in CW-fNIRS-OT by introducing a time-shift inversion strategy that, in tandem with layer-sensitive time-gated windows, achieves an efficient optical properties inversion while effectively decoupling and compensating for path length-dependent distortions. Leveraging a statistical brain model derived from anatomical atlases, our approach synthesizes subject-specific head geometry from simple anthropometric data, explicitly eliminating MRI dependency. Photon-transport simulations are employed to predefine time gates with preferential sensitivity to superficial and deep layers, while a dynamic time-shift correction compensates for residual inter-subject geometric mismatches. Ultimately, this design permits the precise inversion of layer-specific optical properties via a computationally lightweight single-layer diffusion equation model. Validation through numerical simulations, phantom experiments, and in vivo breath-holding tasks demonstrates that the proposed method significantly outperforms conventional empirical-DPF approaches. It corrects systematic path length errors, achieving a quantitativeness ratio of ∼0.95 vs ∼0.85 for conventional methods, and improves spatial fidelity, contrast-to-noise ratio, and task-state discriminability in SVM classification. Affording personalized, high-accuracy DPF inversion with computational efficiency, this framework provides a clinically viable route to individualized cerebral oxygenation assessment and is poised to catalyze the broader adoption of fNIRS in both neuroscientific inquiry and diagnostic practice.

  • Camera-free NIR-II fluorescence molecular tomography via single-pixel spatial frequency domain imaging with photon counting detection

    by Wenxing Bai, Dongyuan Liu, Ye Wu, Chengsi Chai, Jingyu Cao, Feng Gao

    While fluorescence molecular tomography (FMT) in the second near-infrared window (NIR-II) offers improved penetration and contrast, quantitative deep-tissue recovery remains fundamentally ill-conditioned due to photon diffusion and is constrained by the cost, noise floor, and scalability limitations of short-wave infrared (SWIR) focal-plane arrays. We report a camera-free NIR-II FMT architecture integrating NIR-I spatial-frequency-domain (SFD) structured illumination with NIR-II single-pixel photon-counting detection. Co-registered excitation-reference and fluorescence measurements are fused through a multi-frequency normalized Born formulation to reconstruct the effective fluorescence-yield distribution. Phantom experiments demonstrate millimeter-scale dual-inclusion separability and sub-millimeter axial localization at depths up to approximately 7 mm, with a near-linear fluorescence-yield response. This hardware-efficient framework provides a scalable route toward high-sensitivity NIR-II fluorescence tomography.

  • Open Access

    High-synchronization wearable fNIRS-EEG system for investigating neurovascular coupling dynamics at millisecond temporal resolution

    by Yuke Wang, Zeying Li, Wenrui Zhu, Baole Wang, Mengyu Jia, Limin Zhang, Feng Gao, Dongyuan Liu

  • Improving diffuse optical tomography reconstruction using an attention-based U-Net post-processing framework

    by Limin Zhang, Xi Zhang, Xinzheng Yu, Dongyuan Liu, Shitong Wang, Feng Gao

    Diffuse optical tomography (DOT) is a noninvasive imaging technique with promising biomedical applications; however, its reconstruction is severely ill-posed, leading to low spatial resolution, quantitative accuracy, and pronounced robustness when using conventional algorithms. In this study, an attention-enhanced deep learning post-processing method, termed ART-U-Net-CBAM, is proposed to improve DOT image reconstruction. The method combines the physics-based algebraic reconstruction technique (ART) with a U-Net network integrated with a convolutional block attention module (CBAM), enabling adaptive emphasis on informative spatial and channel features. Trained exclusively on simulated data, the proposed network was evaluated using both numerical simulations and phantom experiments involving circular and elliptical targets. Quantitative results demonstrate that ART-U-Net-CBAM consistently outperforms ART and ART-U-Net in terms of reconstruction accuracy, noise robustness, spatial resolution, and structural similarity. These findings indicate that attention-enhanced deep learning post-processing provides an effective and generalizable strategy for enhancing DOT image quality.

  • Open Access

    Synergistic TD-DOS/TD-DCS with Time-gating for Layer-specific Hemodynamics

    by Jing Bai, Yingchao Wu, Tong Zhang, Zeying Li, Limin Zhang, Dongyuan Liu, Feng Gao

    Diffuse optical techniques such as time-domain diffuse optical spectroscopy (TD-DOS) and diffuse correlation spectroscopy (TD-DCS) enable noninvasive assessment of tissue hemodynamics and oxygenation, yet their quantitative accuracy in layered tissues is fundamentally limited by depth-dependent sensitivity and parameter coupling. Here, we propose a time-gated hierarchical TD-DOS/TD-DCS framework, implemented on a fully synchronized multi-wavelength dual-modal platform, that exploits the temporal encoding of photon path length to achieve depth-resolved recovery of optical, hemodynamic, and metabolic parameters. Under a unified time-resolved acquisition scheme, early- and late-arriving photons are sequentially analyzed first to estimate superficial optical properties using a single-layer model, followed by stable recovery of deep-layer absorption and blood flow using a constrained two-layer model. This approach improves parameter identifiability without increasing model complexity. The method was validated using bilayer liquid phantoms and in vivo experiments. In phantoms, the proposed strategy reduced deep-layer absorption error from ~25.6% to ~9.5% compared to conventional single-layer fitting, and improved sensitivity to deep-layer flow changes by ~2.8×. In forearm occlusion measurements, the recovered deep-layer blood flow exhibited significantly greater dynamic contrast than conventional estimates. Breath-holding experiments further demonstrated robust recovery of cerebral blood flow, oxygenation, and metabolic parameters, with physiologically plausible temporal dynamics and a significant correlation between rCBF and rCMRO₂ (r = 0.67 ± 0.06). These results demonstrate that the proposed framework enables robust depth-resolved quantification in layered tissues and provides a unified approach for simultaneous assessment of blood flow, oxygenation, and metabolism in diffuse optical measurements.

  • Performance enhancement of fluorescence molecular tomography imaging based on maximally weighted iteration strategy

    by Zishuo Li, Limin Zhang, Wenjing Sun, Wenhao Sun, Mengyu Jia, Dongyuan Liu, Feng Gao

    Fluorescence molecular tomography (FMT) reconstruction represents an ill-posed inverse problem, and the existing solution methods often serve as estimators that tend to introduce reconstruction errors. In this study, we present a maximally weighted iteration (MWI) based FMT imaging framework designed to mitigate the ill-posedness of the inverse problems by strategically controlling the ill-conditioned weighting matrix through iterative weighted decomposition and a weighted correction term. Furthermore, four types of weighting matrices incorporating L1, L2, Frobenius, and L-inf norms are introduced and quantitatively compared with the conventional Tikhonov regularization method through numerical simulations, phantom and in vivo experiments for both single- and double-target scenarios. These results demonstrate that the MWI-based algorithms, particularly the one using the L2-norm, exhibit superior performance in terms of noise robustness, reconstruction accuracy, and spatial resolution. This study provides an effective strategy to enhance the FMT imaging quality.

  • Open Access

    Machine Learning-Powered fNIRS Detection of Idiopathic Central Precocious Puberty via Prefrontal Cortex Activation

    by Zeying Li, Lifang Jia, Yingxue Zou, Mengyu Jia, Limin Zhang, Dongyuan Liu, Feng Gao

    Objective and Impact Statement: This study examines prefrontal cortex (PFC) hemodynamic responses in children with idiopathic central precocious puberty (ICPP) versus normals and constructs a noninvasive diagnostic model using functional near-infrared spectroscopy (fNIRS) augmented by machine learning. Introduction: Current ICPP diagnosis relies on invasive and time-consuming gonadotropin-releasing hormone stimulation tests. While fNIRS offers a noninvasive alternative, the neural mechanisms underlying ICPP remain unclear, and reliable automated diagnostic tools distinguishing patients from healthy peers are lacking. Methods: fNIRS data were acquired from 167 participants (82 ICPP and 85 normal) during a mental arithmetic (MA) task. General linear models and statistical tests were employed to analyze group and gender-specific activation patterns. Multidimensional features were extracted from hemodynamic signals, and a conditional denoising diffusion probabilistic model (C-DDPM) was introduced for data augmentation. Results: Analysis revealed gender-specific disparities, with the normal group exhibiting more extensive PFC activation than the ICPP group. In classification, a decision tree model using features from key negatively correlated channels achieved 86.57% accuracy. Notably, integrating C-DDPM-generated synthetic data further improved classifier performance metrics. Conclusion: The study elucidates the mechanisms of PFC activation in both normative and ICPP-affected cohorts during MA tasks and validates the effectiveness of machine learning in distinguishing between normal and ICPP children. This study provides a scientific basis for the development of automated, noninvasive rapid diagnostic tools for ICPP.


  • Open Access

    Development of a statistically standardized optical digital wrist model through integrated MRI-diffuse optical imaging methodology

    by Tong Zhang, Lingxiu Xing, Wenjing Sun, Mai Dan, Wenxing Bai, Jiao Li, Dongyuan Liu, Limin Zhang, Feng Gao

    SignificanceCurrent optical health-sensing devices rely on simplified homogeneous tissue models or semi-empirical ratiometric methods, which inadequately address anatomical complexity and inter-individual optical variability. This introduces systematic errors in light propagation modeling, compromising measurement accuracy and clinical robustness, necessitating organ-specific optical models for reliable physiological sensing.AimTo develop a standard optical digital wrist (DW) model by integrating magnetic resonance imaging (MRI) and diffuse optical imaging (DOI), enabling anatomically accurate and optically realistic modeling of wrist tissues for improved precision in wearable optical health monitoring applications.ApproachThe multimodal MRI-DOI framework was implemented, comprising three key components: (1) statistical integration of high-resolution MRI datasets generated a population-averaged anatomical DW template; (2) region-based time-domain diffuse optical tomography (TD-DOT) with MRI-derived anatomical priors, extracted depth-resolved optical properties of subsurface tissues; (3) spatial frequency domain imaging (SFDI) supplemented high-resolution optical properties of superficial skin layers.ResultsSimulation experiments demonstrated the high accuracy of region-based TD-DOT reconstruction, with mean errors below 8.57% (μa) and 9.63% (μs′), quantitatively supporting the precision of the proposed approach. Phantom experiments with wrist-mimicking phantoms yielded mean reconstruction errors of 10.52% (μa) and 13.23% (μs′) for TD-DOT, and the SFDI top-layer quantification yielded lower errors of 4.48% (μa) and 8.69% (μs′), validating the performance of the TD-DOT system and the SFDI system. Furthermore, in vivo optical property measurements showed strong agreement with literature values, further validating the reliability and practicality of the methodology.ConclusionsWe establish a standard DW template and develop an in vivo optical structure acquisition methodology, transitioning biosensing models from homogeneous approximations to anatomically layered models. The approach can enhance the customization, dynamic adaptability, and clinical validity of biosensing technologies.


  • Enhancing Functional Breast Imaging: A sCMOS Camera‐Based Lock‐in Implementation for Dynamic Tomography

    by Yujie Zheng, Limin Zhang, Weijie Song, Feng Gao, Dongyuan Liu

    Diffuse optical tomography (DOT) enables the in vivo quantification of tissue chromophores, specifically the discernment of oxy‐ and deoxy‐hemoglobin (HbO and HbR, correspondingly). This specific criterion is useful in detecting and predicting early‐stage neoadjuvant breast cancer treatment response. To address the issues of the limited channels in the fiber‐dependent breast DOT system and limited signal‐to‐noise ratio in the camera‐dependent systems, we hereby present a camera‐based lock‐in detection scheme to achieve dynamic DOT with improved SNR, which adopted orthogonal frequency division multiplexing technology. The evaluation of the system performance was conducted on tissue phantoms and neoplastic rats, and the results show that this system boasts the capability of executing parallel measurement utilizing a camera detector, enabling the achievement of highly sensitive, and dynamic tomography for breast screening applications.