Youssef Ghosn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Youssef Ghosn has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
Mohammed Hussein Kamareddine
Faculty of Medicine and Medical Sciences, University of Balamand, El-Koura, Lebanon
7 shared publications- Said Farhat
Department of Gastroenterology, Saint George Hospital University Medical Center, Beirut, Lebanon
5 shared publications - Yara Jabbour
Department of Diagnostic Radiology, American University of Beirut, Beirut, Lebanon
5 shared publications - Antonios Tawk
Faculty of Medicine and Medical Sciences, University of Balamand, El-Koura, Lebanon
3 shared publications - Charbel Saade
American University of Beirut Medical Center
3 shared publications - Nada Abbas
Department of Clinical Nutrition and Dietetics, Research Institute of Medical and Health Sciences, College of Health Sciences, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
3 shared publications
Latest Publications
- Open Access
- 20 August 2025
- Published by Springer Nature in Research Square
Prognostic Value of CT Angiography Findings in Patient with Suspected Active Bleeding
Rational and Objective: This study aimed to identify predictors of 28-day mortality in patients with suspected active bleeding undergoing Computed Tomography Angiography (CTA). Materials and Methods: Retrospective analysis of patients who underwent multi-phasic CTA for suspected active bleeding at a major medical center between January 2019 and November 2021 was performed. The study assessed the association of demographic variables, laboratory data, CTA findings, and interventions performed with 28-day mortality. Statistical analyses included chi-square tests, t-tests, Cox Proportional Hazards Model, and Kaplan-Meier survival curves. Results: A total of 174 patients were analyzed, showing an 18% (n=32) mortality rate within the 28-day period. Cox regression analysis showed that substantial contrast extravasation (HR: 2.49, 95% CI: 1.17 - 5.29, p = 0.018), anticoagulation therapy (HR: 2.46, 95% CI: 1.18 - 5.11, p = 0.016), mean INR (HR: 3.73, 95% CI: 1.78 - 7.82, p < 0.001), and vasopressors use (HR: 4.91, 95% CI: 2.31 - 10.41, p < 0.001) were independently associated with an increased risk of mortality. The type of intervention did not significantly affect mortality rates. Conclusion: Substantial contrast extravasation was the only imaging feature independently associated with increased mortality in patients with suspected active bleeding.
- 20 August 2025
- Published by Springer Nature in Research Square
Open AccessPrognostic Value of CT Angiography Findings in Patient with Suspected Active Bleeding
Rational and Objective: This study aimed to identify predictors of 28-day mortality in patients with suspected active bleeding undergoing Computed Tomography Angiography (CTA). Materials and Methods: Retrospective analysis of patients who underwent multi-phasic CTA for suspected active bleeding at a major medical center between January 2019 and November 2021 was performed. The study assessed the association of demographic variables, laboratory data, CTA findings, and interventions performed with 28-day mortality. Statistical analyses included chi-square tests, t-tests, Cox Proportional Hazards Model, and Kaplan-Meier survival curves. Results: A total of 174 patients were analyzed, showing an 18% (n=32) mortality rate within the 28-day period. Cox regression analysis showed that substantial contrast extravasation (HR: 2.49, 95% CI: 1.17 - 5.29, p = 0.018), anticoagulation therapy (HR: 2.46, 95% CI: 1.18 - 5.11, p = 0.016), mean INR (HR: 3.73, 95% CI: 1.78 - 7.82, p < 0.001), and vasopressors use (HR: 4.91, 95% CI: 2.31 - 10.41, p < 0.001) were independently associated with an increased risk of mortality. The type of intervention did not significantly affect mortality rates. Conclusion: Substantial contrast extravasation was the only imaging feature independently associated with increased mortality in patients with suspected active bleeding.
- Open Access
- 1 March 2025
- Published by SAGE Publications in Journal of Medical Extended Reality
- Vol. 2 (1) , 273-289
Augmented Reality in Interventional Radiology: A Review of Systems, Ergonomics, Applications, and Outcomes
Interventional radiology (IR) procedures traditionally rely on two-dimensional imaging for guidance. Augmented reality (AR) offers a transformative approach by overlaying two-dimensional radiological images or three-dimensional digital reconstructions onto the real-world environment, potentially improving procedural precision and operator ergonomics. This narrative literature review examines AR systems, procedural workflow, operator ergonomics, current clinical applications, and outcomes. Inclusion criteria include studies investigating AR in IR, excluding articles unrelated to IR procedures. Current literature suggests improved ergonomics, mainly enhanced depth perception, decreased eye movement/fatigue, and decreased cybersickness with overall operator tolerability. Clinical studies demonstrated reductions in radiation exposure and procedural times, with comparable accuracy to standard techniques. Limitations include the lack of large-scale clinical data and standardized evaluation metrics.
- 1 March 2025
- Published by SAGE Publications in Journal of Medical Extended Reality
- Vol. 2 (1) , 273-289
Open AccessAugmented Reality in Interventional Radiology: A Review of Systems, Ergonomics, Applications, and Outcomes
Interventional radiology (IR) procedures traditionally rely on two-dimensional imaging for guidance. Augmented reality (AR) offers a transformative approach by overlaying two-dimensional radiological images or three-dimensional digital reconstructions onto the real-world environment, potentially improving procedural precision and operator ergonomics. This narrative literature review examines AR systems, procedural workflow, operator ergonomics, current clinical applications, and outcomes. Inclusion criteria include studies investigating AR in IR, excluding articles unrelated to IR procedures. Current literature suggests improved ergonomics, mainly enhanced depth perception, decreased eye movement/fatigue, and decreased cybersickness with overall operator tolerability. Clinical studies demonstrated reductions in radiation exposure and procedural times, with comparable accuracy to standard techniques. Limitations include the lack of large-scale clinical data and standardized evaluation metrics.
- 3 September 2024
- Published by Elsevier in European Journal of Radiology
- Vol. 181, 111718
Para-articular and intra-articular soft tissue lesions: Radiologic-pathologic correlation
- 3 September 2024
- Published by Elsevier in European Journal of Radiology
- Vol. 181, 111718
Para-articular and intra-articular soft tissue lesions: Radiologic-pathologic correlation
- 3 July 2024
- Published by Springer Nature in Emergency Radiology
- Vol. 31 (5) , 641-652
Factors affecting radiation dose, radiation exposure time and procedural time in arterial embolization for active hemorrhage
Purpose To evaluate patient and procedure-related factors contributing to the radiation dose, cumulative fluoroscopy time (CFT), and procedural time (PT) of Arterial Embolization (AE) for suspected active bleeding. Methods Data on patients who underwent AE for suspected bleeding was retrospectively gathered between January 2019 and April 2022. Data collected included the dependent variables consisting of dose-area product (DAP), CFT, PT, and independent variables consisting of demographic, bleeding-specific, and procedure-specific parameters. All statistical computations were performed in SPSS statistics. The alpha value was set at 0.05. Results Data from a total of 148 AE were collected with an average patient’s age of 61.06 ± 21.57 years. Higher DAP was independently associated with male sex (p < 0.002), age ranges between 46 and 65 years (p = 0.019) and > 66 years (p = 0.027), BMI above 30 (p = 0.016), attending with less than 10 years of experience (p = 0.01), and bleeding in the abdomen and pelvis (p = 0.027). Longer CFT was independently associated with attending with less than 10 years of experience (p < 0.001), having 2 (p = 0.004) or > 3 (p = 0.005) foci of bleed, and age between 46 and 65 years (p = 0.007) and ≥ 66 years (p = 0.017). Longer PT was independently associated with attending with less than 10 years of experience (p < 0.001) and having 2 (p = 0.014) or > 3 (p = 0.005) foci of bleed. Conclusion The interventionist experience influenced radiation dose, CFT and PT. Dose was also affected by patients’ sex, age, BMI, as well as bleeding location. CFT was also affected by patients’ age, and both CFT and PT were also affected by the number of bleeding foci. These findings highlight the multifaceted factors that affect radiation dose and procedural time, emphasizing the importance of interventionist expertise, patient’s age, sex, BMI, location and number of bleeds.
- 3 July 2024
- Published by Springer Nature in Emergency Radiology
- Vol. 31 (5) , 641-652
Factors affecting radiation dose, radiation exposure time and procedural time in arterial embolization for active hemorrhage
Purpose To evaluate patient and procedure-related factors contributing to the radiation dose, cumulative fluoroscopy time (CFT), and procedural time (PT) of Arterial Embolization (AE) for suspected active bleeding. Methods Data on patients who underwent AE for suspected bleeding was retrospectively gathered between January 2019 and April 2022. Data collected included the dependent variables consisting of dose-area product (DAP), CFT, PT, and independent variables consisting of demographic, bleeding-specific, and procedure-specific parameters. All statistical computations were performed in SPSS statistics. The alpha value was set at 0.05. Results Data from a total of 148 AE were collected with an average patient’s age of 61.06 ± 21.57 years. Higher DAP was independently associated with male sex (p < 0.002), age ranges between 46 and 65 years (p = 0.019) and > 66 years (p = 0.027), BMI above 30 (p = 0.016), attending with less than 10 years of experience (p = 0.01), and bleeding in the abdomen and pelvis (p = 0.027). Longer CFT was independently associated with attending with less than 10 years of experience (p < 0.001), having 2 (p = 0.004) or > 3 (p = 0.005) foci of bleed, and age between 46 and 65 years (p = 0.007) and ≥ 66 years (p = 0.017). Longer PT was independently associated with attending with less than 10 years of experience (p < 0.001) and having 2 (p = 0.014) or > 3 (p = 0.005) foci of bleed. Conclusion The interventionist experience influenced radiation dose, CFT and PT. Dose was also affected by patients’ sex, age, BMI, as well as bleeding location. CFT was also affected by patients’ age, and both CFT and PT were also affected by the number of bleeding foci. These findings highlight the multifaceted factors that affect radiation dose and procedural time, emphasizing the importance of interventionist expertise, patient’s age, sex, BMI, location and number of bleeds.
- 18 May 2024
- Published by Springer Nature in Emergency Radiology
- Vol. 31 (4) , 439-446
Does delayed phase imaging in CT angiography provide additional information in patients with suspected active bleeding?
Purpose We hypothesize that delayed phase imaging does not provide additional diagnostic information in patients who undergo multi-phasic CTA for suspected active bleeding. Methods Data on patients who underwent multiphasic CTA (pre-contrast, arterial, porto-venous, and delayed phases) for suspected acute bleed were retrospectively collected between January 2019 and November 2021. CTA images were reviewed by a general radiologist, an interventional radiologist, and a body imaging radiologist independently. Each reader evaluated if delayed phase images provided additional information that would change the final impression of the CTA report. Additional information regarding bleeding location, time needed for delayed image acquisition, and radiation exposure were also obtained. Results A total of 104 patients with CTAs were analyzed with an average age of 58 years ± 22. Studies rated with absent additional findings on delayed images were 102 (98.1%) by the interventional radiologist, 101 (97.1%) by the body imaging radiologist, and 100 (96.1%) by the general radiologist with percent agreement of 96.15% (kappa 0.54, p < 0.001). All the findings were characterized as unlikely to be clinically significant. Mean time added to complete a delayed phase images was 3.61 ± 3.4 min. The average CT dose length product (DLP) for the total exam was 3621.78 ± 2129.57 mGy.cm with delayed acquisition adding a mean DLP of 847.75 ± 508.8 mGy.cm. Conclusion Delayed phase imaging does not provide significant additional diagnostic information in evaluating patients with suspected active bleeding but is associated with increased examination time and radiation exposure.
- 18 May 2024
- Published by Springer Nature in Emergency Radiology
- Vol. 31 (4) , 439-446
Does delayed phase imaging in CT angiography provide additional information in patients with suspected active bleeding?
Purpose We hypothesize that delayed phase imaging does not provide additional diagnostic information in patients who undergo multi-phasic CTA for suspected active bleeding. Methods Data on patients who underwent multiphasic CTA (pre-contrast, arterial, porto-venous, and delayed phases) for suspected acute bleed were retrospectively collected between January 2019 and November 2021. CTA images were reviewed by a general radiologist, an interventional radiologist, and a body imaging radiologist independently. Each reader evaluated if delayed phase images provided additional information that would change the final impression of the CTA report. Additional information regarding bleeding location, time needed for delayed image acquisition, and radiation exposure were also obtained. Results A total of 104 patients with CTAs were analyzed with an average age of 58 years ± 22. Studies rated with absent additional findings on delayed images were 102 (98.1%) by the interventional radiologist, 101 (97.1%) by the body imaging radiologist, and 100 (96.1%) by the general radiologist with percent agreement of 96.15% (kappa 0.54, p < 0.001). All the findings were characterized as unlikely to be clinically significant. Mean time added to complete a delayed phase images was 3.61 ± 3.4 min. The average CT dose length product (DLP) for the total exam was 3621.78 ± 2129.57 mGy.cm with delayed acquisition adding a mean DLP of 847.75 ± 508.8 mGy.cm. Conclusion Delayed phase imaging does not provide significant additional diagnostic information in evaluating patients with suspected active bleeding but is associated with increased examination time and radiation exposure.
- Open Access
- 21 March 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 53 (12) , 2713-2721
Massive spinal epidural infantile hemangioma, image findings, and treatment: a case report and review of literature
Spinal involvement of infantile hemangiomas is rare with the predilection to involve the epidural space. A proper diagnosis might be challenging due to the atypical location and variable/inconsistent use of the International Society for the Study of Vascular Anomalies (ISSVA) classification by radiologists, pathologists, and clinicians. A proper diagnosis of epidural infantile hemangioma is key due to the different aggressiveness of the treatment options with inconstant literature regarding the best available treatment. Herein, we present a case of a massive epidural infantile hemangioma successfully treated with only beta-blocker. We discuss the clinical, MRI, CT, ultrasound, and histological features of this lesion as we review the literature with the objective of addressing some of the confusion surrounding the subject.
- 21 March 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 53 (12) , 2713-2721
Open AccessMassive spinal epidural infantile hemangioma, image findings, and treatment: a case report and review of literature
Spinal involvement of infantile hemangiomas is rare with the predilection to involve the epidural space. A proper diagnosis might be challenging due to the atypical location and variable/inconsistent use of the International Society for the Study of Vascular Anomalies (ISSVA) classification by radiologists, pathologists, and clinicians. A proper diagnosis of epidural infantile hemangioma is key due to the different aggressiveness of the treatment options with inconstant literature regarding the best available treatment. Herein, we present a case of a massive epidural infantile hemangioma successfully treated with only beta-blocker. We discuss the clinical, MRI, CT, ultrasound, and histological features of this lesion as we review the literature with the objective of addressing some of the confusion surrounding the subject.
- Open Access
ChatGPT 4 Versus ChatGPT 3.5 on The Final FRCR Part A Sample Questions. Assessing Performance and Accuracy of Explanations
Objective To evaluate the performance of two versions of ChatGPT, GPT4 and GPT3.5, on the Final FRCR (Part A) also referred to as FRCR Part 2A radiology exam. The primary objective is to assess whether these large language models (LLMs) can effectively answer radiology test questions while providing accurate explanations for the answers. Methods The evaluation involves a total of 281 multiple choice questions, combining the 41 FRCR sample questions found on The Royal Collage of Radiologists website and 240 questions from a supplementary test bank. Both GPT4 and GPT3.5 were given the 281 questions with the answer choices, and their responses were assessed for correctness and accuracy of the explanations provided. The 41 FRCR sample questions difficulty was ranked into “low order” and “high order” questions. A significance level of pResults GPT4 demonstrated significant improvement over GPT3.5 in answering the 281 questions, achieving 76.5% correct answers compared to 52.7%, respectively (pConclusion The findings of this study demonstrate a significant improvement in the performance of GPT4 compared to GPT3.5 on FRCR style examination. However, the accuracy of the provided explanations might limit the models’ reliability as learning tools. Advances in Knowledge The study indirectly explores the potential of LLMs to contribute to the diagnostic accuracy and efficiency of medical imaging while raising questions about the current LLMs limitations in providing reliable explanations for radiology related questions hindering its uses for learning and in clinical practice. Highlights ChatGPT4 passed an FRCR part 2A style exam while ChatGPT3.5 did not. ChatGPT4 showed significantly higher correctness of answers and accuracy of explanations. No significant difference in performance was observed between “high order” and “lower order” questions. Explanation accuracy was lower than correct answers rate limiting the Models’ reliability as learning tools.
Open AccessChatGPT 4 Versus ChatGPT 3.5 on The Final FRCR Part A Sample Questions. Assessing Performance and Accuracy of Explanations
Objective To evaluate the performance of two versions of ChatGPT, GPT4 and GPT3.5, on the Final FRCR (Part A) also referred to as FRCR Part 2A radiology exam. The primary objective is to assess whether these large language models (LLMs) can effectively answer radiology test questions while providing accurate explanations for the answers. Methods The evaluation involves a total of 281 multiple choice questions, combining the 41 FRCR sample questions found on The Royal Collage of Radiologists website and 240 questions from a supplementary test bank. Both GPT4 and GPT3.5 were given the 281 questions with the answer choices, and their responses were assessed for correctness and accuracy of the explanations provided. The 41 FRCR sample questions difficulty was ranked into “low order” and “high order” questions. A significance level of pResults GPT4 demonstrated significant improvement over GPT3.5 in answering the 281 questions, achieving 76.5% correct answers compared to 52.7%, respectively (pConclusion The findings of this study demonstrate a significant improvement in the performance of GPT4 compared to GPT3.5 on FRCR style examination. However, the accuracy of the provided explanations might limit the models’ reliability as learning tools. Advances in Knowledge The study indirectly explores the potential of LLMs to contribute to the diagnostic accuracy and efficiency of medical imaging while raising questions about the current LLMs limitations in providing reliable explanations for radiology related questions hindering its uses for learning and in clinical practice. Highlights ChatGPT4 passed an FRCR part 2A style exam while ChatGPT3.5 did not. ChatGPT4 showed significantly higher correctness of answers and accuracy of explanations. No significant difference in performance was observed between “high order” and “lower order” questions. Explanation accuracy was lower than correct answers rate limiting the Models’ reliability as learning tools.
- 17 January 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 148, 110162
Diagnostic value of procedural images in CT-guided interventions
- 17 January 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 148, 110162
Diagnostic value of procedural images in CT-guided interventions
- 1 May 2020
- Published by Elsevier in Radiography
- Vol. 26 (2) , 174-182
State of the art of coronary computed tomography angiography
- 1 May 2020
- Published by Elsevier in Radiography
- Vol. 26 (2) , 174-182
State of the art of coronary computed tomography angiography