Taylor Howard Newton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Taylor Howard Newton has a total of 165 co-authors. Here are the top co-authors by number of shared publications:
- Esra Neufeld
Foundation for Research on Information Technologies in Society (IT’IS), Zurich, Switzerland
7 shared publications - Niels Kuster
Foundation for Research on Information Technologies in Society (IT’IS), Zurich, Switzerland
6 shared publications - Antonino Mario Cassara
Foundation for Research on Information Technologies in Society (IT'IS), Zeughausstrasse 43, Zürich, 8004, SWITZERLAND
4 shared publications Esra Neufeld
Foundation for Research on Information Technologies in Society Zurich Switzerland
3 shared publicationsKatie Zhuang
Foundation for Research on Information Technologies in Society Zurich Switzerland
3 shared publicationsMarwan Abdellah
Blue Brain Project, École Polytechnique Fédérale de Lausanne (EPFL), Geneva, Switzerland
3 shared publications
Latest Publications
- Open Access
- 8 September 2026
- Published by Springer Nature in Communications Biology
A generalized activating function for rapid and accurate neural response prediction in spinal cord stimulation
We present the Generalized Activating Function (GAF), a biophysics-grounded framework that accelerates neural activation predictions by up to three orders of magnitude relative to NEURON simulations of multi-compartment cable models while maintaining high predictive accuracy ( R 2 = 0.99). By overcoming computational bottlenecks in patient-specific modeling, the GAF enables practical translation of computational optimization into neuromodulation therapies such as spinal cord stimulation (SCS). We verify the GAF’s physiological validity by demonstrating near-perfect agreement with multi-compartment simulations for activation thresholds and spike initiation location/timing across multiple pulse widths in an anatomically realistic spine model. We validate clinical relevance by reproducing a published SCS optimization study for lower-limb motor recovery, matching NEURON-based prediction accuracy while reducing computation time from hours to seconds. Finally, we exploit the GAF’s speed to explore previously intractable parameter spaces: Pareto optimization over pulse waveforms uncovers solutions with approximately seven-fold increased energy efficiency at matched activation, while optimization of multielectrode stimulation (16 currents) increases the functional selectivity index for right hip flexion from 52% (clinical benchmark) to 82% in under one minute. By eliminating computational bottlenecks and enabling gains in efficiency and selectivity, the GAF transforms model-driven optimization into a clinically viable tool for patient-specific neuromodulation.
- 8 September 2026
- Published by Springer Nature in Communications Biology
Open AccessA generalized activating function for rapid and accurate neural response prediction in spinal cord stimulation
We present the Generalized Activating Function (GAF), a biophysics-grounded framework that accelerates neural activation predictions by up to three orders of magnitude relative to NEURON simulations of multi-compartment cable models while maintaining high predictive accuracy ( R 2 = 0.99). By overcoming computational bottlenecks in patient-specific modeling, the GAF enables practical translation of computational optimization into neuromodulation therapies such as spinal cord stimulation (SCS). We verify the GAF’s physiological validity by demonstrating near-perfect agreement with multi-compartment simulations for activation thresholds and spike initiation location/timing across multiple pulse widths in an anatomically realistic spine model. We validate clinical relevance by reproducing a published SCS optimization study for lower-limb motor recovery, matching NEURON-based prediction accuracy while reducing computation time from hours to seconds. Finally, we exploit the GAF’s speed to explore previously intractable parameter spaces: Pareto optimization over pulse waveforms uncovers solutions with approximately seven-fold increased energy efficiency at matched activation, while optimization of multielectrode stimulation (16 currents) increases the functional selectivity index for right hip flexion from 52% (clinical benchmark) to 82% in under one minute. By eliminating computational bottlenecks and enabling gains in efficiency and selectivity, the GAF transforms model-driven optimization into a clinically viable tool for patient-specific neuromodulation.
- Open Access
BraiNN: A Modern Simulator for Clinically Feasible Personalized Whole-Brain Network Modeling
Personalized whole-brain modeling aims to transform treatment planning for neurological disorders by enabling patient-specific simulations of brain network dynamics. Neural mass models (NMMs) offer a tractable compromise between biophysical detail and computational cost and can be directly linked to macroscopic observables such as EEG. However, scaling NMMs to whole-brain networks with realistic connectivity, conduction delays, and cortical surface resolution—and fitting them to individual patient data—imposes computational demands that existing frameworks cannot meet at clinically relevant timescales. Here we introduce BraiNN , a JAX-based Python framework for large-scale neural mass modeling that achieves speedups of up to two to three orders of magnitude over existing tools by leveraging GPU/TPU-accelerated, XLA-compiled array computation. BraiNN combines a region-level Jansen–Rit network with a subject-specific cortical surface mesh of coupled neural mass models and biophysically grounded EEG forward modeling via reciprocity-based lead fields. Its fully differentiable computational graph enables a hybrid personalization pipeline that pairs Bayesian optimization for global parameter exploration with gradient-based refinement, completing EEG-driven spectral fitting of an eight-dimensional parameter space in approximately 2–3 hours on a single consumer GPU—compared to multiple days with conventional neural mass modeling software. Numerical verification against established benchmarks confirms that BraiNN faithfully reproduces canonical synchronization and bifurcation dynamics of Jansen–Rit networks. By reducing the time requirements for personalizing a high-detail whole-brain surface model from days to a few hours on consumer-grade hardware, BraiNN brings personalized brain network modeling closer to practical use in clinical contexts. We anticipate that BraiNN will serve as a foundation for patient-specific digital twins and EEG-guided neuromodulation planning.
Open AccessBraiNN: A Modern Simulator for Clinically Feasible Personalized Whole-Brain Network Modeling
Personalized whole-brain modeling aims to transform treatment planning for neurological disorders by enabling patient-specific simulations of brain network dynamics. Neural mass models (NMMs) offer a tractable compromise between biophysical detail and computational cost and can be directly linked to macroscopic observables such as EEG. However, scaling NMMs to whole-brain networks with realistic connectivity, conduction delays, and cortical surface resolution—and fitting them to individual patient data—imposes computational demands that existing frameworks cannot meet at clinically relevant timescales. Here we introduce BraiNN , a JAX-based Python framework for large-scale neural mass modeling that achieves speedups of up to two to three orders of magnitude over existing tools by leveraging GPU/TPU-accelerated, XLA-compiled array computation. BraiNN combines a region-level Jansen–Rit network with a subject-specific cortical surface mesh of coupled neural mass models and biophysically grounded EEG forward modeling via reciprocity-based lead fields. Its fully differentiable computational graph enables a hybrid personalization pipeline that pairs Bayesian optimization for global parameter exploration with gradient-based refinement, completing EEG-driven spectral fitting of an eight-dimensional parameter space in approximately 2–3 hours on a single consumer GPU—compared to multiple days with conventional neural mass modeling software. Numerical verification against established benchmarks confirms that BraiNN faithfully reproduces canonical synchronization and bifurcation dynamics of Jansen–Rit networks. By reducing the time requirements for personalizing a high-detail whole-brain surface model from days to a few hours on consumer-grade hardware, BraiNN brings personalized brain network modeling closer to practical use in clinical contexts. We anticipate that BraiNN will serve as a foundation for patient-specific digital twins and EEG-guided neuromodulation planning.
- Open Access
- 1 April 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (2) , 026061
Precision non-invasive brain stimulation: an in silico pipeline for personalized control of brain dynamics
Objective. Non-invasive brain stimulation (NIBS) offers therapeutic benefits for various brain disorders. Personalization may enhance these benefits by optimizing stimulation parameters for individual subjects. Approach. We present a computational pipeline for simulating and assessing the effects of NIBS using personalized, large-scale brain network activity models. Using structural MRI and diffusion-weighted imaging data, the pipeline leverages a convolutional neural network-based segmentation algorithm to generate subject-specific head models with up to 40 tissue types and personalized dielectric properties. We integrate electromagnetic simulations of NIBS exposure with whole-brain network models to predict NIBS-dependent perturbations in brain dynamics, simulate the resulting EEG traces, and quantify metrics of brain dynamics. Main results. The pipeline is implemented on o2S2PARC, an open, cloud-based infrastructure designed for collaborative and reproducible computational life science. Furthermore, a dedicated planning tool provides guidance for optimizing electrode placements for transcranial temporal interference stimulation. In two proof-of-concept applications, we demonstrate that: (i) transcranial alternating current stimulation produces expected shifts in the EEG spectral response, and (ii) simulated baseline network activity exhibits physiologically plausible fluctuations in inter-hemispheric synchronization. Significance. This pipeline facilitates a shift from exposure-based to response-driven optimization of NIBS, supporting new stimulation paradigms that steer brain dynamics towards desired activity patterns in a controlled manner.
- 1 April 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (2) , 026061
Open AccessPrecision non-invasive brain stimulation: an in silico pipeline for personalized control of brain dynamics
Objective. Non-invasive brain stimulation (NIBS) offers therapeutic benefits for various brain disorders. Personalization may enhance these benefits by optimizing stimulation parameters for individual subjects. Approach. We present a computational pipeline for simulating and assessing the effects of NIBS using personalized, large-scale brain network activity models. Using structural MRI and diffusion-weighted imaging data, the pipeline leverages a convolutional neural network-based segmentation algorithm to generate subject-specific head models with up to 40 tissue types and personalized dielectric properties. We integrate electromagnetic simulations of NIBS exposure with whole-brain network models to predict NIBS-dependent perturbations in brain dynamics, simulate the resulting EEG traces, and quantify metrics of brain dynamics. Main results. The pipeline is implemented on o2S2PARC, an open, cloud-based infrastructure designed for collaborative and reproducible computational life science. Furthermore, a dedicated planning tool provides guidance for optimizing electrode placements for transcranial temporal interference stimulation. In two proof-of-concept applications, we demonstrate that: (i) transcranial alternating current stimulation produces expected shifts in the EEG spectral response, and (ii) simulated baseline network activity exhibits physiologically plausible fluctuations in inter-hemispheric synchronization. Significance. This pipeline facilitates a shift from exposure-based to response-driven optimization of NIBS, supporting new stimulation paradigms that steer brain dynamics towards desired activity patterns in a controlled manner.
- Open Access
SpIC3D imaging: Spinal In-situ Contrast 3D imaging
SUMMARY: High-definition visualization techniques are critical for understanding the neuroanatomy of the spinal cord, an essential structure for sensorimotor and autonomic functions, in both healthy and pathological conditions. Magnetic resonance imaging (MRI) is a common method for visualizing neural structures in 3D. However, techniques for spinal cord MRI have historically achieved limited visualization of rootlets and nerves, especially at lower spinal levels, due to their highly complex and compact organization. Here we developed a spinal in-situ contrast 3D imaging (SpIC3D) method that allows visualization of spinal compartments in fixed animal and human specimens with ultra-high resolution at various spinal levels. Using SpIC3D, we achieved quantification of neuronal cell density in dorsal root ganglia, multi-segment identification of individual rootlets and roots, and volumetric reconstruction of multiple spinal structures for computational modeling. SpIC3D provides a basis for accelerated spinal pathology characterization and personalized spinal cord stimulation treatments.
Open AccessSpIC3D imaging: Spinal In-situ Contrast 3D imaging
SUMMARY: High-definition visualization techniques are critical for understanding the neuroanatomy of the spinal cord, an essential structure for sensorimotor and autonomic functions, in both healthy and pathological conditions. Magnetic resonance imaging (MRI) is a common method for visualizing neural structures in 3D. However, techniques for spinal cord MRI have historically achieved limited visualization of rootlets and nerves, especially at lower spinal levels, due to their highly complex and compact organization. Here we developed a spinal in-situ contrast 3D imaging (SpIC3D) method that allows visualization of spinal compartments in fixed animal and human specimens with ultra-high resolution at various spinal levels. Using SpIC3D, we achieved quantification of neuronal cell density in dorsal root ganglia, multi-segment identification of individual rootlets and roots, and volumetric reconstruction of multiple spinal structures for computational modeling. SpIC3D provides a basis for accelerated spinal pathology characterization and personalized spinal cord stimulation treatments.
- Open Access
- 7 February 2025
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (2) , e22542
Recommendations for the Safe Application of Temporal Interference Stimulation in the Human Brain Part I: Principles of Electrical Neuromodulation and Adverse Effects
Temporal interference stimulation (TIS) is a new form of transcranial electrical stimulation (tES) that has been proposed as a method for targeted, non‐invasive stimulation of deep brain structures. While TIS holds promise for a variety of clinical and non‐clinical applications, little data is yet available regarding its effects in humans and its mechanisms of action. In order to inform the design and safe conduct of experiments involving TIS, researchers require quantitative guidance regarding safe exposure limits and other safety considerations. To this end, we undertook a two‐part effort to determine frequency‐dependent thresholds for applied currents below which TIS is unlikely to pose risk to humans in terms of heating or unwanted stimulation. Part I of this effort, described here, comprises a summary of the current knowledge pertaining to the safety of TIS and related techniques. Specifically, we provide: i) a broad overview of the electrophysiological impacts neurostimulation, ii) a review of the (bio‐)physical principles underlying the mechanisms of action of transcranial alternating/direct stimulation (tACS/tDCS), deep brain stimulation (DBS), and TIS, and iii) a comprehensive survey of the adverse effects (AEs) associated with each technique as reported in the scientific literature and regulatory and clinical databases. In Part II, we perform an in silico study to determine field exposure metrics for tDCS/tACS and DBS under normal (safe) operating conditions and infer frequency‐dependent current thresholds for TIS that result in equivalent levels of exposure.
- 7 February 2025
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (2) , e22542
Open AccessRecommendations for the Safe Application of Temporal Interference Stimulation in the Human Brain Part I: Principles of Electrical Neuromodulation and Adverse Effects
Temporal interference stimulation (TIS) is a new form of transcranial electrical stimulation (tES) that has been proposed as a method for targeted, non‐invasive stimulation of deep brain structures. While TIS holds promise for a variety of clinical and non‐clinical applications, little data is yet available regarding its effects in humans and its mechanisms of action. In order to inform the design and safe conduct of experiments involving TIS, researchers require quantitative guidance regarding safe exposure limits and other safety considerations. To this end, we undertook a two‐part effort to determine frequency‐dependent thresholds for applied currents below which TIS is unlikely to pose risk to humans in terms of heating or unwanted stimulation. Part I of this effort, described here, comprises a summary of the current knowledge pertaining to the safety of TIS and related techniques. Specifically, we provide: i) a broad overview of the electrophysiological impacts neurostimulation, ii) a review of the (bio‐)physical principles underlying the mechanisms of action of transcranial alternating/direct stimulation (tACS/tDCS), deep brain stimulation (DBS), and TIS, and iii) a comprehensive survey of the adverse effects (AEs) associated with each technique as reported in the scientific literature and regulatory and clinical databases. In Part II, we perform an in silico study to determine field exposure metrics for tDCS/tACS and DBS under normal (safe) operating conditions and infer frequency‐dependent current thresholds for TIS that result in equivalent levels of exposure.
- Open Access
- 15 January 2025
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (1) , e22536
Recommendations for the Safe Application of Temporal Interference Stimulation in the Human Brain Part II: Biophysics, Dosimetry, and Safety Recommendations
Temporal interference stimulation (TIS) is a new form of transcranial electrical stimulation (tES) that has been proposed as a method for targeted, noninvasive stimulation of deep brain structures. While TIS holds promise for a variety of clinical and nonclinical applications, little data is yet available regarding its effects in humans and its mechanisms of action. To inform the design and safe conduct of experiments involving TIS, researchers require quantitative guidance regarding safe exposure limits and other safety considerations. To this end, we undertook a two‐part effort to determine frequency‐dependent thresholds for applied currents below which TIS is unlikely to pose risk to humans in terms of heating or unwanted stimulation. In Part II of this effort, described here, we draw on a previously compiled list (see Part I) of adverse effects (AEs) reported for transcranial direct/alternating current stimulation (tDCS/ACS), deep brain stimulation (DBS), and TIS to determine biophysics‐informed exposure metrics for assessing safety. Using an in silico approach, we conduct multiphysics simulations of various tACS, DBS, and TIS exposure scenarios in an anatomically detailed head and brain model. By matching the stimulation in terms of the identified exposure metrics, we infer frequency‐dependent TIS parameters that produce exposure conditions equivalent to those known to be safe for tACS and DBS. Based on the results of our simulations and existing knowledge regarding tES and DBS safety, we propose frequency‐dependent thresholds below which TIS voltages and currents are unlikely to pose a risk to humans. Safety‐related data from ongoing and future human studies are required to verify and refine the thresholds proposed here.
- 15 January 2025
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (1) , e22536
Open AccessRecommendations for the Safe Application of Temporal Interference Stimulation in the Human Brain Part II: Biophysics, Dosimetry, and Safety Recommendations
Temporal interference stimulation (TIS) is a new form of transcranial electrical stimulation (tES) that has been proposed as a method for targeted, noninvasive stimulation of deep brain structures. While TIS holds promise for a variety of clinical and nonclinical applications, little data is yet available regarding its effects in humans and its mechanisms of action. To inform the design and safe conduct of experiments involving TIS, researchers require quantitative guidance regarding safe exposure limits and other safety considerations. To this end, we undertook a two‐part effort to determine frequency‐dependent thresholds for applied currents below which TIS is unlikely to pose risk to humans in terms of heating or unwanted stimulation. In Part II of this effort, described here, we draw on a previously compiled list (see Part I) of adverse effects (AEs) reported for transcranial direct/alternating current stimulation (tDCS/ACS), deep brain stimulation (DBS), and TIS to determine biophysics‐informed exposure metrics for assessing safety. Using an in silico approach, we conduct multiphysics simulations of various tACS, DBS, and TIS exposure scenarios in an anatomically detailed head and brain model. By matching the stimulation in terms of the identified exposure metrics, we infer frequency‐dependent TIS parameters that produce exposure conditions equivalent to those known to be safe for tACS and DBS. Based on the results of our simulations and existing knowledge regarding tES and DBS safety, we propose frequency‐dependent thresholds below which TIS voltages and currents are unlikely to pose a risk to humans. Safety‐related data from ongoing and future human studies are required to verify and refine the thresholds proposed here.
- Open Access
- 1 June 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (3) , 036032
A novel CNN-based image segmentation pipeline for individualized feline spinal cord stimulation modeling
Objective. Spinal cord stimulation (SCS) is a well-established treatment for managing certain chronic pain conditions. More recently, it has also garnered attention as a means of modulating neural activity to restore lost autonomic or sensory-motor function. Personalized modeling and treatment planning are critical aspects of safe and effective SCS (Rowald and Amft 2022 Front. Neurorobotics 16 983072, Wagneret al2018 Nature 563 65–71). However, the generation of spine models at the required level of detail and accuracy requires time and labor intensive manual image segmentation by human experts. This study aims to develop a maximally automated segmentation routine capable of producing high-quality anatomical models, even with limited data, to facilitate safe and effective personalized SCS treatment planning.Approach. We developed an automated image segmentation and model generation pipeline based on a novel convolutional neural network (CNN) architecture trained on feline spinal cord magnetic resonance imaging data. The pipeline includes steps for image preprocessing, data augmentation, transfer learning, and cleanup. To assess the relative importance of each step in the pipeline and our choice of CNN architecture, we systematically dropped steps or substituted architectures, quantifying the downstream effects in terms of tissue segmentation quality (Jaccard index and Hausdorff distance) and predicted nerve recruitment (estimated axonal depolarization).Main results. The leave-one-out analysis demonstrated that each pipeline step contributed a small but measurable increment to mean segmentation quality. Surprisingly, minor differences in segmentation accuracy translated to significant deviations (ranging between 4% and 13% for each pipeline step) in predicted nerve recruitment, highlighting the importance of careful workflow design. Additionally, transfer learning techniques enhanced segmentation metric consistency and allowed generalization to a completely different spine region with minimal additional training data.Significance. To our knowledge, this work is the first to assess the downstream impacts of segmentation quality differences on neurostimulation predictions. It highlights the role of each step in the pipeline and paves the way towards fully automated, personalized SCS treatment planning in clinical settings.
- 1 June 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (3) , 036032
Open AccessA novel CNN-based image segmentation pipeline for individualized feline spinal cord stimulation modeling
Objective. Spinal cord stimulation (SCS) is a well-established treatment for managing certain chronic pain conditions. More recently, it has also garnered attention as a means of modulating neural activity to restore lost autonomic or sensory-motor function. Personalized modeling and treatment planning are critical aspects of safe and effective SCS (Rowald and Amft 2022 Front. Neurorobotics 16 983072, Wagneret al2018 Nature 563 65–71). However, the generation of spine models at the required level of detail and accuracy requires time and labor intensive manual image segmentation by human experts. This study aims to develop a maximally automated segmentation routine capable of producing high-quality anatomical models, even with limited data, to facilitate safe and effective personalized SCS treatment planning.Approach. We developed an automated image segmentation and model generation pipeline based on a novel convolutional neural network (CNN) architecture trained on feline spinal cord magnetic resonance imaging data. The pipeline includes steps for image preprocessing, data augmentation, transfer learning, and cleanup. To assess the relative importance of each step in the pipeline and our choice of CNN architecture, we systematically dropped steps or substituted architectures, quantifying the downstream effects in terms of tissue segmentation quality (Jaccard index and Hausdorff distance) and predicted nerve recruitment (estimated axonal depolarization).Main results. The leave-one-out analysis demonstrated that each pipeline step contributed a small but measurable increment to mean segmentation quality. Surprisingly, minor differences in segmentation accuracy translated to significant deviations (ranging between 4% and 13% for each pipeline step) in predicted nerve recruitment, highlighting the importance of careful workflow design. Additionally, transfer learning techniques enhanced segmentation metric consistency and allowed generalization to a completely different spine region with minimal additional training data.Significance. To our knowledge, this work is the first to assess the downstream impacts of segmentation quality differences on neurostimulation predictions. It highlights the role of each step in the pipeline and paves the way towards fully automated, personalized SCS treatment planning in clinical settings.
- Open Access
Safety Recommendations for Temporal Interference Stimulation in the Brain
Temporal interference stimulation (TIS) is a new form of transcranial electrical stimulation (tES) that has been proposed as a method for targeted, non-invasive stimulation of deep brain structures. While TIS holds promise for a variety of clinical and non-clinical applications, little data is yet available regarding its effects in humans. To inform the design and approval of experiments involving TIS, researchers require quantitative guidance regarding exposure limits and other safety concerns. To this end, we sought to delineate a safe range of exposure parameters (voltages and currents applied via external scalp electrodes) for TIS in humans through comparisons with well-established but related brain stimulation modalities. Specifically, we surveyed the literature for adverse events (AEs) associated with transcranial alternating/direct current stimulation (tACS/tDCS), deep brain stimulation (DBS), and TIS to establish known boundaries for safe operating conditions. Drawing on the biophysical mechanisms associated with the identified AEs, we determined appropriate exposure metrics for each stimulation modality. Using these metrics, we conducted an in silico comparison of various exposure scenarios for tACS, DBS, and TIS using multiphysics simulations in an anatomically detailed head model with realistic current strengths. By matching stimulation scenarios in terms of biophysical impact, we inferred the frequency-dependent TIS stimulation parameters that resulted in exposure magnitudes known to be safe for tACS and DBS. Based on the results of our simulations and existing knowledge regarding tES and DBS safety, we propose frequency-dependent thresholds below which TIS voltages and currents are unlikely to pose a risk to humans. Safety-related data from ongoing and future human studies are required to verify and refine the thresholds proposed here.
Open AccessSafety Recommendations for Temporal Interference Stimulation in the Brain
Temporal interference stimulation (TIS) is a new form of transcranial electrical stimulation (tES) that has been proposed as a method for targeted, non-invasive stimulation of deep brain structures. While TIS holds promise for a variety of clinical and non-clinical applications, little data is yet available regarding its effects in humans. To inform the design and approval of experiments involving TIS, researchers require quantitative guidance regarding exposure limits and other safety concerns. To this end, we sought to delineate a safe range of exposure parameters (voltages and currents applied via external scalp electrodes) for TIS in humans through comparisons with well-established but related brain stimulation modalities. Specifically, we surveyed the literature for adverse events (AEs) associated with transcranial alternating/direct current stimulation (tACS/tDCS), deep brain stimulation (DBS), and TIS to establish known boundaries for safe operating conditions. Drawing on the biophysical mechanisms associated with the identified AEs, we determined appropriate exposure metrics for each stimulation modality. Using these metrics, we conducted an in silico comparison of various exposure scenarios for tACS, DBS, and TIS using multiphysics simulations in an anatomically detailed head model with realistic current strengths. By matching stimulation scenarios in terms of biophysical impact, we inferred the frequency-dependent TIS stimulation parameters that resulted in exposure magnitudes known to be safe for tACS and DBS. Based on the results of our simulations and existing knowledge regarding tES and DBS safety, we propose frequency-dependent thresholds below which TIS voltages and currents are unlikely to pose a risk to humans. Safety-related data from ongoing and future human studies are required to verify and refine the thresholds proposed here.