Weihao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Weihao Wu has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Hucheng Chen
Brookhaven National Laboratory
3 shared publications - Kai Chen
Key Laboratory of Quark and Lepton Physics (MOE), Central China Normal University, Wuhan, China
3 shared publications W. Zhi
State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240
3 shared publicationsWei Zhi
The State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University , Shanghai 200240
3 shared publicationsZhizhen Zhou
State Key Laboratory of Dark Matter Physics, the Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, and the School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai, China
3 shared publicationsD.L. Xu
State Key Laboratory of Dark Matter Physics, Tsung-Dao Lee Institute & School of Physics and Astronomy, Tsung-Dao Lee Institute, Shanghai Jiao Tong University, Shanghai, China
2 shared publications
Latest Publications
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10031
The high speed analog optical readout system designed for low temperature experiments
For low-temperature experiments such as liquid xenon dark matter detectors, it is crucial to read out detector signals from cryostats. Traditionally, photoelectrical signals are transmitted from the cryogenic region to the outside using coaxial cables through vacuum feedthroughs on the cryostats. In this paper, we investigate an analog optical transmission method in which the raw electrical signals are converted into optical signals with light intensity linearly proportional to the electrical amplitude, transmitted out of the cryogenic environment through optical fiber, and subsequently converted back into electrical signals by photoelectric devices while preserving the signal waveform. This new approach offers advantages, including low attenuation over long-distance transmission and reduced crosstalk across the feedthroughs. Additionally, the low-temperature optical wavelength multiplexing scheme has been investigated and applied, increasing the transmission capability of a single fiber. At -100 ∘ C, the proposed analog optical readout system achieves a -3 dB bandwidth of larger than 150 MHz, a dynamic range of up to 500 mV, and a low cryogenic-region power consumption of 70 mW per channel, demonstrating its strong potential for low-temperature experiments.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10031
The high speed analog optical readout system designed for low temperature experiments
For low-temperature experiments such as liquid xenon dark matter detectors, it is crucial to read out detector signals from cryostats. Traditionally, photoelectrical signals are transmitted from the cryogenic region to the outside using coaxial cables through vacuum feedthroughs on the cryostats. In this paper, we investigate an analog optical transmission method in which the raw electrical signals are converted into optical signals with light intensity linearly proportional to the electrical amplitude, transmitted out of the cryogenic environment through optical fiber, and subsequently converted back into electrical signals by photoelectric devices while preserving the signal waveform. This new approach offers advantages, including low attenuation over long-distance transmission and reduced crosstalk across the feedthroughs. Additionally, the low-temperature optical wavelength multiplexing scheme has been investigated and applied, increasing the transmission capability of a single fiber. At -100 ∘ C, the proposed analog optical readout system achieves a -3 dB bandwidth of larger than 150 MHz, a dynamic range of up to 500 mV, and a low cryogenic-region power consumption of 70 mW per channel, demonstrating its strong potential for low-temperature experiments.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
A cryogenic characterization platform for commercial off-the-shelf (COTS) electronic devices in liquid xenon detectors for high-energy physics experiments
The increasing deployment of cryogenic noble-liquid detectors in high-energy physics experiments has created a growing demand for reliable qualification methods for electronic components operating at temperatures beyond their specified ranges. However, the operating temperature range specified for commercial off-the-shelf electronic components typically does not extend to cryogenic temperatures, leaving their low-temperature characteristics insufficiently characterized and introducing uncertainties in detector electronics design. This study presents a versatile cryogenic characterization platform that enables systematic qualification of commercial electronic components under detector-relevant operating conditions. The platform provides a stable temperature environment centered at 165 K, corresponding to liquid xenon detector operation, while maintaining the relative humidity below 15% to minimize condensation-related failures. Furthermore, an FPGA-based digital electronics subsystem was developed to support device evaluation, with its key functional modules individually qualified to ensure reliable operation at 165 K before system-level integration. The platform was used to evaluate the performance of an ADI ADS52J65 analog-to-digital converter (ADC) and to characterize the cryogenic behavior of a Hamamatsu S13370 silicon photomultiplier (SiPM). Both devices operated reliably at 165 K. The ADC achieved a signal-to-noise ratio of ∼64 dB with a near-full-scale 1.1 MHz sinusoidal input, while the dark count rate of the SiPM was reduced to below 1 Hz. This study demonstrates a practical platform for the cryogenic characterization of front-end electronic devices intended for liquid xenon detectors. By combining a controlled cryogenic environment with a qualified digital electronics subsystem, the platform provides a reusable experimental infrastructure for evaluating commercial electronic components under cryogenic operating conditions and offers a practical solution for reducing uncertainties in the development of front-end electronics for liquid xenon detectors.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
A cryogenic characterization platform for commercial off-the-shelf (COTS) electronic devices in liquid xenon detectors for high-energy physics experiments
The increasing deployment of cryogenic noble-liquid detectors in high-energy physics experiments has created a growing demand for reliable qualification methods for electronic components operating at temperatures beyond their specified ranges. However, the operating temperature range specified for commercial off-the-shelf electronic components typically does not extend to cryogenic temperatures, leaving their low-temperature characteristics insufficiently characterized and introducing uncertainties in detector electronics design. This study presents a versatile cryogenic characterization platform that enables systematic qualification of commercial electronic components under detector-relevant operating conditions. The platform provides a stable temperature environment centered at 165 K, corresponding to liquid xenon detector operation, while maintaining the relative humidity below 15% to minimize condensation-related failures. Furthermore, an FPGA-based digital electronics subsystem was developed to support device evaluation, with its key functional modules individually qualified to ensure reliable operation at 165 K before system-level integration. The platform was used to evaluate the performance of an ADI ADS52J65 analog-to-digital converter (ADC) and to characterize the cryogenic behavior of a Hamamatsu S13370 silicon photomultiplier (SiPM). Both devices operated reliably at 165 K. The ADC achieved a signal-to-noise ratio of ∼64 dB with a near-full-scale 1.1 MHz sinusoidal input, while the dark count rate of the SiPM was reduced to below 1 Hz. This study demonstrates a practical platform for the cryogenic characterization of front-end electronic devices intended for liquid xenon detectors. By combining a controlled cryogenic environment with a qualified digital electronics subsystem, the platform provides a reusable experimental infrastructure for evaluating commercial electronic components under cryogenic operating conditions and offers a practical solution for reducing uncertainties in the development of front-end electronics for liquid xenon detectors.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2511-2519
Performance Study and Circuit Simulation for R12699-406-M4 Photomultiplier Tube Base
The next-generation liquid xenon experiments like PandaX-xT target an energy range from sub-keV to multi-MeV to address the requirement of multiple physics searches. The Hamamatsu R12699-406-M4 photomultiplier tubes (PMTs) were developed and selected as photon sensors for PandaX-xT. Their voltage-divider base is optimized for a broad dynamic range, from single-photoelectron (SPE) sensitivity to 30 nC collected charge (matching the 2.458 MeV Q-value of 136Xe neutrinoless double beta decay (NLDBD)). Using a dedicated test bench, we characterize the saturation and suppression responses of R12699-406-M4 PMTs with this base design. Based on measured PMT-base responses, we develop a circuit simulation model that accurately reproduces the physical mechanisms underlying these effects with key parameters tuned via experimental data. The combined simulation and bench-test approach guides base design and optimization, enabling improved detector dynamic range and supporting future saturation and suppression correction studies in data analysis.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2511-2519
Performance Study and Circuit Simulation for R12699-406-M4 Photomultiplier Tube Base
The next-generation liquid xenon experiments like PandaX-xT target an energy range from sub-keV to multi-MeV to address the requirement of multiple physics searches. The Hamamatsu R12699-406-M4 photomultiplier tubes (PMTs) were developed and selected as photon sensors for PandaX-xT. Their voltage-divider base is optimized for a broad dynamic range, from single-photoelectron (SPE) sensitivity to 30 nC collected charge (matching the 2.458 MeV Q-value of 136Xe neutrinoless double beta decay (NLDBD)). Using a dedicated test bench, we characterize the saturation and suppression responses of R12699-406-M4 PMTs with this base design. Based on measured PMT-base responses, we develop a circuit simulation model that accurately reproduces the physical mechanisms underlying these effects with key parameters tuned via experimental data. The combined simulation and bench-test approach guides base design and optimization, enabling improved detector dynamic range and supporting future saturation and suppression correction studies in data analysis.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
A Sub-mW Ultra-Low-Power PMT Base with High-Voltage Boosting
A sub-mW ultra-low-power high-voltage (HV) boosting PMT base is presented, achieving power consumption as low as 0.42 mW at +1250 V and 0.89 mW at +2000 V, representing a significant improvement in power efficiency compared to previously reported PMT base designs. The core of the proposed PMT base is a high-voltage boosting circuit developed from a modified flyback converter integrated with a voltage multiplier. The operating principles of the circuit are analyzed in detail, including the mechanism of voltage boosting and energy transfer. Furthermore, the power dissipation of the HV boosting circuit is theoretically analyzed and optimized. To validate the theoretical model, we conducted an experiment measuring the oscillation period and power consumption before and after adding a capacitor in parallel with the secondary winding, confirming the accuracy of the calculations. Finally, the proposed PMT base is experimentally verified through a series of joint tests with a PMT, including high counting rate and large signal conditions, demonstrating stable and correct operation.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
A Sub-mW Ultra-Low-Power PMT Base with High-Voltage Boosting
A sub-mW ultra-low-power high-voltage (HV) boosting PMT base is presented, achieving power consumption as low as 0.42 mW at +1250 V and 0.89 mW at +2000 V, representing a significant improvement in power efficiency compared to previously reported PMT base designs. The core of the proposed PMT base is a high-voltage boosting circuit developed from a modified flyback converter integrated with a voltage multiplier. The operating principles of the circuit are analyzed in detail, including the mechanism of voltage boosting and energy transfer. Furthermore, the power dissipation of the HV boosting circuit is theoretically analyzed and optimized. To validate the theoretical model, we conducted an experiment measuring the oscillation period and power consumption before and after adding a capacitor in parallel with the secondary winding, confirming the accuracy of the calculations. Finally, the proposed PMT base is experimentally verified through a series of joint tests with a PMT, including high counting rate and large signal conditions, demonstrating stable and correct operation.
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , T08002
Exploration of optimized front-end readout circuit for time measurement of large-area SiPM arrays
The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An application-specific integrated circuit (ASIC) is being developed to aim at high-resolution time measurement of large-area SiPM arrays. This work investigates four architectures of readout circuits including different input stages (common gate stage and negative feedback common gate stage) and discriminators (two types of current discriminator and one voltage discriminator) using a 180 nm CMOS process for optimizing time resolution. The experimental measurements show that single photon time resolutions performed using Hamamatsu S13360-3050PE SiPMs are around 260 ps full width at half maximum (FWHM). A timing jitter less than 500 ps FWHM when connecting a 6 × 6 mm2 SiPM array is achieved. The power consumption is less than 7 mW/channel. Additionally, a digital summation is applied to reduce the number of output interfaces. The measured performances of the ASIC cater to the TRIDENT application requirements.
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , T08002
Exploration of optimized front-end readout circuit for time measurement of large-area SiPM arrays
The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An application-specific integrated circuit (ASIC) is being developed to aim at high-resolution time measurement of large-area SiPM arrays. This work investigates four architectures of readout circuits including different input stages (common gate stage and negative feedback common gate stage) and discriminators (two types of current discriminator and one voltage discriminator) using a 180 nm CMOS process for optimizing time resolution. The experimental measurements show that single photon time resolutions performed using Hamamatsu S13360-3050PE SiPMs are around 260 ps full width at half maximum (FWHM). A timing jitter less than 500 ps FWHM when connecting a 6 × 6 mm2 SiPM array is achieved. The power consumption is less than 7 mW/channel. Additionally, a digital summation is applied to reduce the number of output interfaces. The measured performances of the ASIC cater to the TRIDENT application requirements.
- Open Access
- 14 May 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (5) , 1-19
Measurement of two-neutrino double electron capture half-life of 124Xe with PandaX-4T
Detailed studies of two-neutrino double electron capture (2νDEC) is a crucial step towards searching for the neutrinoless mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2νDEC process in 124Xe, utilizing a total exposure of 1.73 tonne year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $$ \mathcal{O} $$ (10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2νDEC process to be (1.03 ± 0.15stat ± 0.08sys) × 1022 yr. Furthermore, we have evaluated the capture fraction for both electrons captured from the K shell (KK) to be (65 ± 5)%, which aligns with the 124Xe nuclear model calculations within 1.8 σ.- 14 May 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (5) , 1-19
Open AccessMeasurement of two-neutrino double electron capture half-life of 124Xe with PandaX-4T
Detailed studies of two-neutrino double electron capture (2νDEC) is a crucial step towards searching for the neutrinoless mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2νDEC process in 124Xe, utilizing a total exposure of 1.73 tonne year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $$ \mathcal{O} $$ (10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2νDEC process to be (1.03 ± 0.15stat ± 0.08sys) × 1022 yr. Furthermore, we have evaluated the capture fraction for both electrons captured from the K shell (KK) to be (65 ± 5)%, which aligns with the 124Xe nuclear model calculations within 1.8 σ. - 17 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 400-405
A Prototype of the Timing Electronic System for the CALICE SDHCAL
The upgrade of the CALICE (Calorimeter for Linear Collider Experiment) Semi-Digital Hadronic Calorimeter (SDHCAL) to Timing-SDHCAL aims to leverage high-resolution time information by replacing the active layers made of Glass Resistive Plate Chamber (GRPC) detectors with Multi-gap Resistive Plate Chamber (MRPC) ones. This enhancement allows for the identification of neutral and charged particles and the separation of close-by showers. Consequently, a new electronic system is required to read out the MRPC signals. In this paper, we present a prototype of timing electronics based on the Petiroc2B ASIC, along with a Data Acquisition (DAQ) system built on the Zynq UltraScale+ SoC. The system demonstrates a satisfactory single-shot time resolution of 41.9 picoseconds. Additionally, the prototype has been tested with MRPC to detect cosmic rays. This prototype provides a feasible approach to constructing high-resolution timing electronic systems for MRPC and serves as a preparatory step for the Timing-SDHCAL.
- 17 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 400-405
A Prototype of the Timing Electronic System for the CALICE SDHCAL
The upgrade of the CALICE (Calorimeter for Linear Collider Experiment) Semi-Digital Hadronic Calorimeter (SDHCAL) to Timing-SDHCAL aims to leverage high-resolution time information by replacing the active layers made of Glass Resistive Plate Chamber (GRPC) detectors with Multi-gap Resistive Plate Chamber (MRPC) ones. This enhancement allows for the identification of neutral and charged particles and the separation of close-by showers. Consequently, a new electronic system is required to read out the MRPC signals. In this paper, we present a prototype of timing electronics based on the Petiroc2B ASIC, along with a Data Acquisition (DAQ) system built on the Zynq UltraScale+ SoC. The system demonstrates a satisfactory single-shot time resolution of 41.9 picoseconds. Additionally, the prototype has been tested with MRPC to detect cosmic rays. This prototype provides a feasible approach to constructing high-resolution timing electronic systems for MRPC and serves as a preparatory step for the Timing-SDHCAL.
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , P06011
Front-end electronics development of large-area SiPM arrays for high-precision single-photon time measurement
TRopIcal DEep-sea Neutrino Telescope (TRIDENT) plans to incorporate silicon photomultipliers (SiPMs) with superior time resolution in addition to photomultiplier tubes (PMTs) into its detection units, namely hybrid Digital Optical Modules (hDOMs), to improve its angular resolution. However, the time resolution significantly degrades for large-area SiPMs due to the large detector capacitance, posing significant challenges for the readout electronics of SiPMs in hDOM. We analyzed the influences of series and parallel connections when constructing a large-area SiPM array and designed a series-parallel connection SiPM array with differential output. We also designed a high-speed pre-amplifier based on transformers (MABA-007159) and radio frequency amplifiers (BGA2803), and an analog multi-channel summing circuit based on operational amplifiers (LMH6629). We measured the single photon time resolution (SPTR) of a 4 × 4 SiPM (Hamamatsu S13360-3050PE) array (12 × 12 mm2) of approximately 300 ps FWHM. This front-end readout design enables the large-area SiPM array to achieve high-precision single photon time measurement in one readout channel.
- 1 June 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (06) , P06011
Front-end electronics development of large-area SiPM arrays for high-precision single-photon time measurement
TRopIcal DEep-sea Neutrino Telescope (TRIDENT) plans to incorporate silicon photomultipliers (SiPMs) with superior time resolution in addition to photomultiplier tubes (PMTs) into its detection units, namely hybrid Digital Optical Modules (hDOMs), to improve its angular resolution. However, the time resolution significantly degrades for large-area SiPMs due to the large detector capacitance, posing significant challenges for the readout electronics of SiPMs in hDOM. We analyzed the influences of series and parallel connections when constructing a large-area SiPM array and designed a series-parallel connection SiPM array with differential output. We also designed a high-speed pre-amplifier based on transformers (MABA-007159) and radio frequency amplifiers (BGA2803), and an analog multi-channel summing circuit based on operational amplifiers (LMH6629). We measured the single photon time resolution (SPTR) of a 4 × 4 SiPM (Hamamatsu S13360-3050PE) array (12 × 12 mm2) of approximately 300 ps FWHM. This front-end readout design enables the large-area SiPM array to achieve high-precision single photon time measurement in one readout channel.
- Top Cited PapersOpen Access
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05063
The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3
The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 1034 cm-2 s-1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 1034 cm-2 s-1, with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05063
Top Cited PapersOpen AccessThe ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3
The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 1034 cm-2 s-1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 1034 cm-2 s-1, with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.