AGAgnese Giaz

Agnese Giaz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Agnese Giaz has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spectroscopy of Ne Isotopes Toward the \(N = 20\) Island of Inversion

    by D. Genna, S. Bottoni, G. Benzoni, K. Wimmer, P. Aguilera, F. Drent, F. Recchia, G. Andreetta, F. Angelini, M. Balogh, et al.

    The structure of light nuclei approaching the \(N = 20\) Island of Inversion was investigated in two multi-nucleon transfer experiments performed at Legnaro National Laboratories using the AGATA-PRISMA setup. This paper presents preliminary results on the decay level schemes of \(^{23,25}\)Ne. The analysis presented here focuses on the study of negative-parity states to probe the evolution of shell structure along the \(Z = 10\) isotopic chain, and provide stringent constraints for state-of-the-art theoretical models. Published by the Jagiellonian University 2026 authors

  • Open Access

    Fusion of 12C+28Si at deep sub-barrier energies

    by A.M. Stefanini, G. Montagnoli, M. Del Fabbro, A. Goasduff, P.A. Aguilera Jorquera, G. Andreetta, F. Angelini, L.V. D’aUria, M. Balogh, D. Bazzacco, et al.


  • Open Access

    Statistical properties and photon strength functions of the Sn112,114 isotopes below the neutron separation threshold

    by P.-A. Söderström, M. Markova, N. Tsoneva, Y. Xu, A. Kuşoğlu, S. Aogaki, D. L. Balabanski, S. R. Ban, R. Borcea, M. Brezeanu, et al.

    Here we report on the measurements of the γ -ray strength functions and nuclear level densities of Sn 112 , 114 performed for the first time at the 9-MV Tandem accelerator facilities at Horia Hulubei Institute for Physics and Nuclear Engineering using the Oslo method. We extract thermodynamic properties and gross and fine properties of the pygmy dipole resonance for systematic comparison in the chain of Sn isotopes. The results are compared with microscopic models implemented in the TALYS reaction code and the fully microscopic quasiparticle-phonon model for the underlying nuclear structure of the dipole strength in Sn 112 , 114 . The quasiparticle-phonon model results show the importance of complex configurations to the low-energy dipole response in the pygmy dipole resonance energy region. The experimental data are further included in the cross section and reaction rate calculations for the ( n , γ ) reaction of the p -process nuclei Sn 112 , 114 showing a significant increase in reaction rates at high temperatures compared to existing nuclear databases.


  • Open Access

    A Position Sensitive Detector With Real-Time Gamma/Neutron Discrimination Capability

    by O. Halfon, C. Riboldi, K. Urban, G. Borghi, M. Carminati, F. Bonforte, M. Donetti, M. Pullia, F. Camera, A. Giaz, et al.

    In recent years, the demand for a gamma and neutron camera with real time discrimination capabilities has emerged in nuclear physics and medical imaging fields. Specifically, in the field of hadrontherapy, Prompt Gamma Imaging (PGI), a technique for range verification purposes, is strongly affected by the presence of a large neutron background, which can limit the possibility to perform precise range monitoring, especially in the framework of Carbon Ion Radiotherapy (CIRT). This work focuses on the design and development of a compact camera with gamma/neutron discrimination to perform range verification in hadrontherapy, exploiting the gamma signal while discarding the uncorrelated neutron component. Thanks to its dual imaging capability, neutron images can still be stored and used in other applications. Pulse Shape Discrimination (PSD) was selected as the method for gamma/neutron discrimination after evaluating several techniques. Among the available options, we selected a CLYC inorganic scintillator as the optimal choice to perform PSD. The detector, based on a 5 cm × 5 cm × 2 cm CLYC crystal, read out by SiPM tiles and compact electronics, acquires and converts in real time digital PSD coefficients. The use of four 16-channels custom GAMMA ASICs allows to store the channels amplitude information, allowing to retrieve the particle point of interaction in the monolithic crystal and to obtain PSD-resolved images. The system discrimination capability was verified with experimental measurements in laboratory and in beam tests, and a preliminary evaluation of its imaging capability with real-time PSD was successfully conducted.


  • Open Access

    Probing the isospin mixing in the 72Kr compound nucleus via GDR γ decay

    by Agnese Giaz, Oliver Wieland, Angela Bracco, Franco Camera, Soichiro Aogaki, Dimiter L. Balabanski, Maria Brezeanu, Ruxandra Borcea, Marian Boromiza, Ion Burducea, et al.


  • Open Access

    Gamma-Ray Position-of-Interaction Estimation in a Thick Monolithic LaBr 3 Detector Using Artificial Neural Networks

    by T. Ferri, F. Rosellini, A. Caracciolo, G. Borghi, M. Carminati, F. Camera, A. Giaz, C. Fiorini

    Monolithic gamma-ray detectors can be used in SPECT systems for monitoring the delivered dose during Boron Neutron Capture Therapy treatments. Gamma-ray hit localization in thick monolithic scintillator crystals is a challenging task due to internal reflections and Compton scattering. Existing methods like the Center of Gravity (CoG) are susceptible to reconstruction uncertainties at the crystal edges, while approaches including non-linear analytical and statistical models, such as the Maximum-Likelihood, require significant computational resources. Artificial Neural Networks (ANN) offer significant improvements in terms of accuracy and computational speed. In this study, we develop a supervised ANN regression algorithm for real-time position reconstruction in a thick square lanthanum bromide crystal (LaBr3(Ce+Sr)) with 5 cm×5 cm×2 cm dimensions, coupled with an 8×8 matrix of SiPMs. The implemented neural network was trained and tested using calibration data acquired irradiating the crystal with a collimated 137Cs source (pencil-beam irradiation). The detector in combination with the ANN model achieves a positioning accuracy for single-gamma-ray events of approximately 2.6 mm in the central region, evaluated as the Full Width at Half Maximum (FWHM) of the prediction error distribution, slightly worsening towards the edges. The imaging capabilities of the detector in combination with a channel-edge pinhole collimator were then evaluated by acquiring images of a movable uncollimated 137Cs point source. The source was shifted in 9 different positions at 3 mm distance from each other and the resolution of the system was evaluated fitting the images with a Gaussian curve. An image spatial resolution of around 8 mm FWHM was obtained, dominated as expected by the collimator geometry, with an accuracy of 0.7 mm in estimating the position of the point source.


  • Open Access

    Design and commissioning of a Silicon Photomultiplier-based dosimeter for Low Dose Rate (LDR) oncological brachytherapy

    by A. Burdyko, M. Caccia, A. Giaz, R. Santoro, G. Tomaciello

    Brachytherapy is a radiotherapy procedure performed with radioactive sources implanted into the patient's body, close to the area affected by cancer. This is a reference procedure for the treatment of prostate and gynecologic cancer due to the reduction of the dose released close to organs at risk (e.g., rectum, bladder, colon). For this reason, real-time dose verification and source localisation are essential for an optimal treatment plan. The ORIGIN collaboration aims to achieve this goal through a 16-fibre sensor system, designed to house a small volume of scintillating material in a transparent fibre tip to enable point-like measurements. The selected scintillating materials feature a decay time of about 500 μs and the signal associated with the primary γ-ray interaction results in the emission of a sequence of single photons distributed over time. Therefore, the dosimeter requires a detector with single-photon sensitivity and a system designed to provide dose measurements by photon counting. Uniformity of fibre response, system stability and reproducibility of measurements are key features of the dosimeter. The characterisation of the 16-channel dosimeter system equipped with thermo-electrically cooled Silicon Photomultipliers, carried out in the laboratory using an X-ray cabinet, is discussed and the results are compared with an earlier version equipped with SiPMs operated at room temperature.

  • Open Access

    Characterisation of a Silicon Photomultiplier Based Oncological Brachytherapy Fibre Dosimeter

    by Massimo Caccia, Agnese Giaz, Marco Galoppo, Romualdo Santoro, Micheal Martyn, Carla Bianchi, Raffaele Novario, Peter Woulfe, Sinead O’keeffe

    Source localisation and real-time dose verification are at the forefront of medical research in brachytherapy, an oncological radiotherapy procedure based on radioactive sources implanted in the patient body. The ORIGIN project aims to respond to this medical community’s need by targeting the development of a multi-point dose mapping system based on fibre sensors integrating a small volume of scintillating material into the tip and interfaced with silicon photomultipliers operated in counting mode. In this paper, a novel method for the selection of the optimal silicon photomultipliers to be used is presented, as well as a laboratory characterisation based on dosimetric figures of merit. More specifically, a technique exploiting the optical cross-talk to maintain the detector linearity in high-rate conditions is demonstrated. Lastly, it is shown that the ORIGIN system complies with the TG43-U1 protocol in high and low dose rate pre-clinical trials with actual brachytherapy sources, an essential requirement for assessing the proposed system as a dosimeter and comparing the performance of the system prototype against the ORIGIN project specifications.


  • Open Access

    A γ-Ray Detector Based on a 3” LaBr3:Ce:Sr Crystal With SiPM Readout for 80 keV–16 MeV Energy Range With Position Sensitivity for Doppler Correction

    by Marco Agnolin, Davide Di Vita, Giacomo Borghi, Marco Carminati, Franco Camera, Oliver Wieland, Bénédicte Million, Agnese Giaz, Constantin Mihai, Andrei Turturica, et al.

    We report the validation in an extended energy range (80 keV –≃ 16 MeV) of the GAMMA detector, a high-dynamic-range, high-resolution, gamma-ray spectrometer for nuclear physics applications based on a 3" co-doped lanthanum bromide (LaBr 3 :Ce:Sr) crystal (73 ph/keV conversion efficiency, 25 ns decay time) coupled to 144 NUV-HD Silicon Photomultipliers (SiPMs). The detector shows state-of-the-art energy resolution along the entire range thanks to the automatic gain switching feature (Adaptive Gain Control, AGC) of the custom ASICs employed in the system. To the best of our knowledge, this is the first time that SiPMs have been used to measure such high energy together with a wide dynamic range and excellent energy resolution (2.7% at 662 keV). In addition, the pixelated nature of the SiPMs detectors, combined with Machine Learning algorithms, can be exploited to reconstruct the position of the first interaction of the gamma rays inside the scintillation crystal. Previous measurements with a 137 Cs collimated source have achieved a spatial resolution better than 2 cm. This performance in position sensitivity has been used to compensate for the relativistic Doppler broadening effects of gamma rays at 15.110(3) MeV emitted by a carbon nucleus moving at relativistic speed (v/c ≃ 0.05) resulting from a boron-on-deuterium reaction, improving the FWHM resolution of the peak by 15%, which is in agreement with the theoretical expectation.