Liebin Zhao
Liebin Zhao has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Fei Wang
Synyi Research, Shanghai, China
2 shared publications - Handong Ma
Synyi Research, Shanghai, China
2 shared publications - Jiang Han
Pediatric Translational Medicine Institute, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 shared publications - Ken Chen
Synyi Research, Shanghai, China
2 shared publications - Lei Fang
Synyi Research, Shanghai, China
2 shared publications - Shaodian Zhang
Synyi Research, Shanghai, China
2 shared publications
Latest Publications
- 2 February 2026
- Published by Wiley in International Journal of Imaging Systems and Technology
- Vol. 36 (2)
A Dual‐Center Study on Intelligent Detection of Ventricular Septal Defect in Pediatric Echocardiographic Videos Using the TSDNet Model
This study aimed to develop an automated transthoracic echocardiography (TTE)‐based system for detecting ventricular septal defects (VSD) by jointly analyzing systolic‐phase temporal shunt dynamics and precisely localizing defect regions. This multicenter retrospective study analyzed transthoracic echocardiography videos from 324 pediatric patients (150 VSD ‐positive and 174 VSD ‐negative), supplemented by an external validation cohort of 60 cases. To address challenges inherent to dynamic cardiac hemodynamics and view‐dependent variability, we developed a Temporal–Spatial Decoupled Network ( TSDNet ). The methodological contributions of TSDNet are fourfold: (1) a temporal–spatial decoupling strategy that separates transient systolic shunt dynamics from static anatomical localization, overcoming the limitations of conventional spatiotemporal coupling; (2) a dual‐branch architecture that integrates a UniFormer ‐based temporal classifier with a YOLOv5 ‐based spatial detector to jointly perform video‐level diagnosis and frame‐level shunt localization; (3) multi‐view fusion across five standard echocardiographic views to capture complementary anatomical structures and hemodynamic signatures; and (4) a comprehensive evaluation framework encompassing accuracy, recall, specificity, F1 ‐score, PPV , and NPV , supplemented by experiments across multiple temporal window lengths and comparative analyses against state‐of‐the‐art object detection models. T SDNet demonstrated high performance in both video‐level classification and frame‐level VSD detection. Video‐level accuracy on the internal test set reached 96.19%, with external performance remaining consistently strong across varying temporal windows (87.37%–90.37% accuracy). For frame‐level detection, TSDNet achieved 86.86% accuracy on the internal test set and 73.75% on the external cohort, with longer temporal windows yielding progressively improved results. Across all evaluated metrics, TSDNet outperformed leading detection frameworks—including Sparse R‐ CNN , DINO , FCOS , RetinaNet , Faster R‐ CNN , and DCNv2 . Multi‐view analysis further confirmed stable detection performance, particularly in the A4C , PSAX , and subRVOT views, underscoring the effectiveness of combining diverse echocardiographic perspectives with temporal–spatial decoupling for robust VSD identification. T SDNet provides accurate, robust, and interpretable detection of VSD from pediatric echocardiography videos. Its strong generalizability and seamless alignment with clinical workflows underscore its potential to enhance diagnostic capability in primary healthcare settings and to support early identification of congenital heart disease.
- 2 February 2026
- Published by Wiley in International Journal of Imaging Systems and Technology
- Vol. 36 (2)
A Dual‐Center Study on Intelligent Detection of Ventricular Septal Defect in Pediatric Echocardiographic Videos Using the TSDNet Model
This study aimed to develop an automated transthoracic echocardiography (TTE)‐based system for detecting ventricular septal defects (VSD) by jointly analyzing systolic‐phase temporal shunt dynamics and precisely localizing defect regions. This multicenter retrospective study analyzed transthoracic echocardiography videos from 324 pediatric patients (150 VSD ‐positive and 174 VSD ‐negative), supplemented by an external validation cohort of 60 cases. To address challenges inherent to dynamic cardiac hemodynamics and view‐dependent variability, we developed a Temporal–Spatial Decoupled Network ( TSDNet ). The methodological contributions of TSDNet are fourfold: (1) a temporal–spatial decoupling strategy that separates transient systolic shunt dynamics from static anatomical localization, overcoming the limitations of conventional spatiotemporal coupling; (2) a dual‐branch architecture that integrates a UniFormer ‐based temporal classifier with a YOLOv5 ‐based spatial detector to jointly perform video‐level diagnosis and frame‐level shunt localization; (3) multi‐view fusion across five standard echocardiographic views to capture complementary anatomical structures and hemodynamic signatures; and (4) a comprehensive evaluation framework encompassing accuracy, recall, specificity, F1 ‐score, PPV , and NPV , supplemented by experiments across multiple temporal window lengths and comparative analyses against state‐of‐the‐art object detection models. T SDNet demonstrated high performance in both video‐level classification and frame‐level VSD detection. Video‐level accuracy on the internal test set reached 96.19%, with external performance remaining consistently strong across varying temporal windows (87.37%–90.37% accuracy). For frame‐level detection, TSDNet achieved 86.86% accuracy on the internal test set and 73.75% on the external cohort, with longer temporal windows yielding progressively improved results. Across all evaluated metrics, TSDNet outperformed leading detection frameworks—including Sparse R‐ CNN , DINO , FCOS , RetinaNet , Faster R‐ CNN , and DCNv2 . Multi‐view analysis further confirmed stable detection performance, particularly in the A4C , PSAX , and subRVOT views, underscoring the effectiveness of combining diverse echocardiographic perspectives with temporal–spatial decoupling for robust VSD identification. T SDNet provides accurate, robust, and interpretable detection of VSD from pediatric echocardiography videos. Its strong generalizability and seamless alignment with clinical workflows underscore its potential to enhance diagnostic capability in primary healthcare settings and to support early identification of congenital heart disease.
- Open Access
- 16 July 2019
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 7 (3) , e13331
Improving the Efficacy of the Data Entry Process for Clinical Research With a Natural Language Processing–Driven Medical Information Extraction System: Quantitative Field Research
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The growing interest in observational trials using patient historical data from electric medical records (EMRs) poses challenges to both efficiency and quality of clinical data collection and management. However, even using electronic data capture (EDC) system and electronic case report form (eCRF), a manual data entry process followed by chart review is still inevitable and becomes an efficiency bottleneck. Objective: To facilitate the data entry process, we developed a natural language processing (NLP)-driven medical information extraction system (NLP-MIES) based on the i2b2 reference standard. We aimed to evaluate whether our NLP-MIES based eCRF application could improve both the accuracy and speed of the data entry process. Methods: We conducted a randomized and controlled field experiment and recruited a total of 24 eligible participants, 12 for manual group and 12 for NLP-MIES support group. We simulated the real-world eCRF filling process using our system and compared the performance of data entry on two research topics, pediatric congenital heart disease and pneumonia. Results: For congenital heart disease eCRF, NLP-MIES support was associated with an increasing of 15% (95% CI 4% to 120%, P=0.0269) in geometric mean accuracy and a reduction of 33% (95% CI 22% to 42%, P <0.001) in geometric mean of the time consumed. For pneumonia eCRF, NLP-MIES support was associated with an increasing of 18% (95% CI 6% to 32%, P =0.0075) in geometric mean accuracy and a reduction of 31% (95% CI 19% to 41%, P =0.001) in geometric mean of the time consumed. Conclusions: Our system could improve both the accuracy and speed of the data entry process.
- 16 July 2019
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 7 (3) , e13331
Open AccessImproving the Efficacy of the Data Entry Process for Clinical Research With a Natural Language Processing–Driven Medical Information Extraction System: Quantitative Field Research
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The growing interest in observational trials using patient historical data from electric medical records (EMRs) poses challenges to both efficiency and quality of clinical data collection and management. However, even using electronic data capture (EDC) system and electronic case report form (eCRF), a manual data entry process followed by chart review is still inevitable and becomes an efficiency bottleneck. Objective: To facilitate the data entry process, we developed a natural language processing (NLP)-driven medical information extraction system (NLP-MIES) based on the i2b2 reference standard. We aimed to evaluate whether our NLP-MIES based eCRF application could improve both the accuracy and speed of the data entry process. Methods: We conducted a randomized and controlled field experiment and recruited a total of 24 eligible participants, 12 for manual group and 12 for NLP-MIES support group. We simulated the real-world eCRF filling process using our system and compared the performance of data entry on two research topics, pediatric congenital heart disease and pneumonia. Results: For congenital heart disease eCRF, NLP-MIES support was associated with an increasing of 15% (95% CI 4% to 120%, P=0.0269) in geometric mean accuracy and a reduction of 33% (95% CI 22% to 42%, P <0.001) in geometric mean of the time consumed. For pneumonia eCRF, NLP-MIES support was associated with an increasing of 18% (95% CI 6% to 32%, P =0.0075) in geometric mean accuracy and a reduction of 31% (95% CI 19% to 41%, P =0.001) in geometric mean of the time consumed. Conclusions: Our system could improve both the accuracy and speed of the data entry process.
- Open Access
- 18 January 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Improving the Efficacy of the Data Entry Process for Clinical Research With a Natural Language Processing–Driven Medical Information Extraction System: Quantitative Field Research (Preprint)
BACKGROUND The growing interest in observational trials using patient data from electronic medical records poses challenges to both efficiency and quality of clinical data collection and management. Even with the help of electronic data capture systems and electronic case report forms (eCRFs), the manual data entry process followed by chart review is still time consuming. OBJECTIVE To facilitate the data entry process, we developed a natural language processing–driven medical information extraction system (NLP-MIES) based on the i2b2 reference standard. We aimed to evaluate whether the NLP-MIES–based eCRF application could improve the accuracy and efficiency of the data entry process. METHODS We conducted a randomized and controlled field experiment, and 24 eligible participants were recruited (12 for the manual group and 12 for NLP-MIES–supported group). We simulated the real-world eCRF completion process using our system and compared the performance of data entry on two research topics, pediatric congenital heart disease and pneumonia. RESULTS For the congenital heart disease condition, the NLP-MIES–supported group increased accuracy by 15% (95% CI 4%-120%, P=.03) and reduced elapsed time by 33% (95% CI 22%-42%, P<.001) compared with the manual group. For the pneumonia condition, the NLP-MIES–supported group increased accuracy by 18% (95% CI 6%-32%, P=.008) and reduced elapsed time by 31% (95% CI 19%-41%, P<.001). CONCLUSIONS Our system could improve both the accuracy and efficiency of the data entry process.
- 18 January 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessImproving the Efficacy of the Data Entry Process for Clinical Research With a Natural Language Processing–Driven Medical Information Extraction System: Quantitative Field Research (Preprint)
BACKGROUND The growing interest in observational trials using patient data from electronic medical records poses challenges to both efficiency and quality of clinical data collection and management. Even with the help of electronic data capture systems and electronic case report forms (eCRFs), the manual data entry process followed by chart review is still time consuming. OBJECTIVE To facilitate the data entry process, we developed a natural language processing–driven medical information extraction system (NLP-MIES) based on the i2b2 reference standard. We aimed to evaluate whether the NLP-MIES–based eCRF application could improve the accuracy and efficiency of the data entry process. METHODS We conducted a randomized and controlled field experiment, and 24 eligible participants were recruited (12 for the manual group and 12 for NLP-MIES–supported group). We simulated the real-world eCRF completion process using our system and compared the performance of data entry on two research topics, pediatric congenital heart disease and pneumonia. RESULTS For the congenital heart disease condition, the NLP-MIES–supported group increased accuracy by 15% (95% CI 4%-120%, P=.03) and reduced elapsed time by 33% (95% CI 22%-42%, P<.001) compared with the manual group. For the pneumonia condition, the NLP-MIES–supported group increased accuracy by 18% (95% CI 6%-32%, P=.008) and reduced elapsed time by 31% (95% CI 19%-41%, P<.001). CONCLUSIONS Our system could improve both the accuracy and efficiency of the data entry process.
- Open Access
- 1 January 2016
- Published by Japan Atherosclerosis Society in Journal of Atherosclerosis and Thrombosis
- Vol. 23 (2) , 216-224
Free Triiodothyronine Concentrations are Inversely Associated with Elevated Carotid Intima-Media Thickness in Middle-Aged and Elderly Chinese Population
Aim : Increased carotid artery intima media thickness (C-IMT) is an early feature of atherosclerosis. It has been reported to be altered in patients with thyroid dysfunction, and the evidence is still controversial. The present study aimed to explore the relationship between C-IMT and possible variations in thyroid function in Chinese adults aged 40 years and above. Methods : A community-based cross-sectional study was conducted among 2276 non-diabetic participants. Serum free triiodothyronine (FT3), free thyroxine (FT4), and thyroid stimulating hormone (TSH) were determined by chemiluminescent microparticle immunoassay. Results : The prevalence of elevated C-IMT decreased according to FT3 quartiles (29.8%, 24.3%, 24.2%, and 22.2%, P for trend=0.005). In both univariate and multivariate linear regression analyses, FT3 levels were inversely associated with C-IMT (both P values ≤ 0.002). Multivariate-adjusted logistic regression analysis showed that high FT3 levels were associated with low prevalent elevated C-IMT. The adjusted odds ratio for elevated C-IMT was 0.71 (95% confidence interval, 0.52-0.99, P=0.04) when comparing the highest with the lowest quartile of FT3. Conclusions: Serum FT3 levels were inversely associated with elevated C-IMT in middle-aged and elderly Chinese adults without diabetes, independent of traditional risk factors for atherosclerosis.
- 1 January 2016
- Published by Japan Atherosclerosis Society in Journal of Atherosclerosis and Thrombosis
- Vol. 23 (2) , 216-224
Open AccessFree Triiodothyronine Concentrations are Inversely Associated with Elevated Carotid Intima-Media Thickness in Middle-Aged and Elderly Chinese Population
Aim : Increased carotid artery intima media thickness (C-IMT) is an early feature of atherosclerosis. It has been reported to be altered in patients with thyroid dysfunction, and the evidence is still controversial. The present study aimed to explore the relationship between C-IMT and possible variations in thyroid function in Chinese adults aged 40 years and above. Methods : A community-based cross-sectional study was conducted among 2276 non-diabetic participants. Serum free triiodothyronine (FT3), free thyroxine (FT4), and thyroid stimulating hormone (TSH) were determined by chemiluminescent microparticle immunoassay. Results : The prevalence of elevated C-IMT decreased according to FT3 quartiles (29.8%, 24.3%, 24.2%, and 22.2%, P for trend=0.005). In both univariate and multivariate linear regression analyses, FT3 levels were inversely associated with C-IMT (both P values ≤ 0.002). Multivariate-adjusted logistic regression analysis showed that high FT3 levels were associated with low prevalent elevated C-IMT. The adjusted odds ratio for elevated C-IMT was 0.71 (95% confidence interval, 0.52-0.99, P=0.04) when comparing the highest with the lowest quartile of FT3. Conclusions: Serum FT3 levels were inversely associated with elevated C-IMT in middle-aged and elderly Chinese adults without diabetes, independent of traditional risk factors for atherosclerosis.