Sopida Thavornpradit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sopida Thavornpradit has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Kevin Burgess
Department of Chemistry, Texas A & M University, Box 30012, College Station, Texas 77842, USA
3 shared publications - Syed Muhammad Usama
Department of Chemistry, University of Texas at San Antonio, 1 UTSA Circle, San Antonio, Texas 78249, United States
3 shared publications - Arthorn Loisruangsin
Division of Chemistry, Department of Physical and Material Sciences, Faculty of Liberal Arts and Science, Kasetsart University, Kamphaeng Saen Campus, Nakhon Pathom 73140, Thailand
1 shared publication - Chen-Ming Lin
Department of Chemistry, Texas A & M University, Box 30012, College Station, TX 77842, USA
1 shared publication - David E. Bergbreiter
Department of Chemistry, Texas A&M University, College Station, TX 77843, USA
1 shared publication G. Kate Park
Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114, United States
1 shared publication
Latest Publications
- 7 January 2026
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 50 (4) , 1787-1795
New colorimetric rhodamine–helicene “OFF–ON” fluorescence sensor based on FRET for quantitative and qualitative Hg 2+ determination
A novel fluorescent sensor designated as DGM was synthesized by integrating rhodamine 6G with a [5]helicene derivative that served as the binding scaffold and tris(2-aminoethyl)amine as the linking agent. The DGM sensor exhibited a “turn-on” fluorescence response specific to Hg2+, which had a substantial Stokes shift of 176 nm and a detection limit of 21 ppb. This sensor functioned through the Hg2+-induced ring-opening of the rhodamine 6G spirolactam, triggering an efficient Förster resonance energy transfer process from the [5]helicene to rhodamine 6G. DGM demonstrated excellent selectivity toward Hg2+ compared to other metal ions, highlighting the sensor's suitability for detecting Hg2+ in real water samples. Moreover, the sensor enabled qualitative, on-site investigation through a distinct colorimetric change from pale yellow to pink, which is readily observable by the naked eye.
- 7 January 2026
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 50 (4) , 1787-1795
New colorimetric rhodamine–helicene “OFF–ON” fluorescence sensor based on FRET for quantitative and qualitative Hg 2+ determination
A novel fluorescent sensor designated as DGM was synthesized by integrating rhodamine 6G with a [5]helicene derivative that served as the binding scaffold and tris(2-aminoethyl)amine as the linking agent. The DGM sensor exhibited a “turn-on” fluorescence response specific to Hg2+, which had a substantial Stokes shift of 176 nm and a detection limit of 21 ppb. This sensor functioned through the Hg2+-induced ring-opening of the rhodamine 6G spirolactam, triggering an efficient Förster resonance energy transfer process from the [5]helicene to rhodamine 6G. DGM demonstrated excellent selectivity toward Hg2+ compared to other metal ions, highlighting the sensor's suitability for detecting Hg2+ in real water samples. Moreover, the sensor enabled qualitative, on-site investigation through a distinct colorimetric change from pale yellow to pink, which is readily observable by the naked eye.
- 18 February 2022
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 13 (3) , 470-474
QuatCy-I2 and MHI-I2 in Photodynamic Therapy
MHI-I2 (1) and QuatCy-I2 (2) were compared in terms of properties important for early-stage photodynamic therapy preclinical candidates. Thus, experiments were performed to monitor dark cytotoxicities, light/dark cytotoxicity ratios, selectivity of localization in tumors over other organs, and clearance from the plasma.
- 18 February 2022
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 13 (3) , 470-474
QuatCy-I2 and MHI-I2 in Photodynamic Therapy
MHI-I2 (1) and QuatCy-I2 (2) were compared in terms of properties important for early-stage photodynamic therapy preclinical candidates. Thus, experiments were performed to monitor dark cytotoxicities, light/dark cytotoxicity ratios, selectivity of localization in tumors over other organs, and clearance from the plasma.
- 18 May 2020
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 18 (22) , 4248-4256
Minimizing solvent waste in catalytic reactions in highly recyclable hydrocarbon solvents
This paper describes chemistry using organocatalysts in hydrocarbon solvents that minimizes solvent waste by using inexpensive, non-volatile, relatively inflammable, and easily recyclable poly(α-olefin)s (PAOs) as hydrocarbon solvents.
- 18 May 2020
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 18 (22) , 4248-4256
Minimizing solvent waste in catalytic reactions in highly recyclable hydrocarbon solvents
This paper describes chemistry using organocatalysts in hydrocarbon solvents that minimizes solvent waste by using inexpensive, non-volatile, relatively inflammable, and easily recyclable poly(α-olefin)s (PAOs) as hydrocarbon solvents.
- 18 July 2019
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 17 (30) , 7150-7154
Protein labelling and albumin binding characteristics of the near-IR Cy7 fluorophore, QuatCy
“QuatCy” selectively labels Cys side-chains, and proteins with exposed Cys residues over albumin.
- 18 July 2019
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 17 (30) , 7150-7154
Protein labelling and albumin binding characteristics of the near-IR Cy7 fluorophore, QuatCy
“QuatCy” selectively labels Cys side-chains, and proteins with exposed Cys residues over albumin.
- 17 September 2018
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 1 (4) , 1195-1205
Optimized Heptamethine Cyanines for Photodynamic Therapy
Over 10 near-IR fluorescent sensitizers were prepared to explore their properties relevant to potential applications in photodynamic therapy (PDT). Key properties of these compounds are that they can be excited around 800 nm, (i) are hydrophilic, (ii) generate singlet oxygen with acceptable quantum yields, and (iii) are imported into cancer cells via the organic anion transporter proteins (OATPs). (This is crucial to tumor localization.) The N-substituents of these cyanines were varied to adjust their charges and polarities and to accommodate conjugation to other entities (e.g., biomolecules or fragments to expand their theranostic modalities). Thus, it was possible to optimize their photocytotoxicities without compromising their other desirable characteristics for PDT. Overall, sensitizers like this have superior characteristics relative to clinically approved sensitizers for PDT insofar as they can be excited at greater depths in tissue.
- 17 September 2018
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 1 (4) , 1195-1205
Optimized Heptamethine Cyanines for Photodynamic Therapy
Over 10 near-IR fluorescent sensitizers were prepared to explore their properties relevant to potential applications in photodynamic therapy (PDT). Key properties of these compounds are that they can be excited around 800 nm, (i) are hydrophilic, (ii) generate singlet oxygen with acceptable quantum yields, and (iii) are imported into cancer cells via the organic anion transporter proteins (OATPs). (This is crucial to tumor localization.) The N-substituents of these cyanines were varied to adjust their charges and polarities and to accommodate conjugation to other entities (e.g., biomolecules or fragments to expand their theranostic modalities). Thus, it was possible to optimize their photocytotoxicities without compromising their other desirable characteristics for PDT. Overall, sensitizers like this have superior characteristics relative to clinically approved sensitizers for PDT insofar as they can be excited at greater depths in tissue.