AMAntonino Massone

Antonino Massone

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Antonino Massone has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Personalized Exoskeleton Gait Training in Incomplete Spinal Cord Injury

    by Amy Bellitto, Maria Eugenia Cordera, Sergio Mandraccia, Clara Leoncini, Antonino Massone, Maura Casadio, Camilla Pierella

    Spinal cord injury (SCI) profoundly affects motor–sensory functions, reducing mobility and quality of life. Robotic exoskeletons offer a promising solution to support gait training, improve mobility, and prevent secondary complications. Existing research predominantly focuses on complete SCI, with limited exploration of long-term effects and tailored training for incomplete SCI. This study investigates device-based outcomes of personalized exoskeleton gait training in 33 individuals with incomplete SCI, with different lesion levels: cervical, thoracic, and lumbar. Participants underwent up to 39 sessions of gait training with a commercially available lower limb exoskeleton. Session parameters, including duration, intensity, and modality, were tailored to each individual’s clinical needs as determined by a medical team. Analysis focused on endurance, performance on the device, and patient-reported outcomes related to walking fluidity, safety, and satisfaction. Results showed overall improvement in endurance and performance, with the most significant gains observed in participants with thoracic-level injuries. All participants reported increased perceived safety, walking fluidity, and high satisfaction with the training. These findings support the potential of personalized exoskeleton training to enhance outcomes and experiences for individuals with incomplete SCI. The difference in improvement between lesion levels highlights the need for customized approaches to address the diverse clinical conditions within this population.


  • Open Access

    A Body–Machine Interface for Assistive Robot Control in Spinal Cord Injury: System Description and Preliminary Tests

    by Aurora Freccero, Maddalena Feder, Giorgio Grioli, Manuel Giuseppe Catalano, Antonino Massone, Antonio Bicchi, Maura Casadio

    Motor impairments, particularly spinal cord injuries, impact thousands of people each year, resulting in severe sensory and motor disabilities. Assistive technologies play a crucial role in supporting these individuals with activities of daily living. Among such technologies, body–machine interfaces (BoMIs) are particularly important, as they convert residual body movements into control signals for external robotic devices. The main challenge lies in developing versatile control interfaces that can adapt to the unique needs of individual users. This study aims to adapt for people with spinal cord injury a novel control framework designed to translate residual user movements into commands for the humanoid robot Alter-Ego. After testing and refining the control algorithm, we developed an experimental protocol to train users to control the robot in a simulated environment. A total of 12 unimpaired participants and two individuals affected by spinal cord injury participated in this study, which was designed to assess the system’s applicability and gather end-user feedback on its performance in assisting with daily tasks. Key metrics such as the system’s usability, accuracy, performance, and improvement metrics in navigation and reaching tasks were assessed. The results suggest that assistive robots can be effectively controlled using minimal residual movements. Furthermore, structured training sessions significantly enhance overall performance and improve the accuracy of the control algorithm across the selected tasks.


  • Open Access

    Recovery of Distal Arm Movements in Spinal Cord Injured Patients with a Body-Machine Interface: A Proof-of-Concept Study

    by Camilla Pierella, Elisa Galofaro, Alice De Luca, Luca Losio, Simona Gamba, Antonino Massone, Ferdinando A. Mussa-Ivaldi, Maura Casadio

    Background: The recovery of upper limb mobility and functions is essential for people with cervical spinal cord injuries (cSCI) to maximize independence in daily activities and ensure a successful return to normality. The rehabilitative path should include a thorough neuromotor evaluation and personalized treatments aimed at recovering motor functions. Body-machine interfaces (BoMI) have been proven to be capable of harnessing residual joint motions to control objects like computer cursors and virtual or physical wheelchairs and to promote motor recovery. However, their therapeutic application has still been limited to shoulder movements. Here, we expanded the use of BoMI to promote the whole arm’s mobility, with a special focus on elbow movements. We also developed an instrumented evaluation test and a set of kinematic indicators for assessing residual abilities and recovery. Methods: Five inpatient cSCI subjects (four acute, one chronic) participated in a BoMI treatment complementary to their standard rehabilitative routine. The subjects wore a BoMI with sensors placed on both proximal and distal arm districts and practiced for 5 weeks. The BoMI was programmed to promote symmetry between right and left arms use and the forearms’ mobility while playing games. To evaluate the effectiveness of the treatment, the subjects’ kinematics were recorded while performing an evaluation test that involved functional bilateral arms movements, before, at the end, and three months after training. Results: At the end of the training, all subjects learned to efficiently use the interface despite being compelled by it to engage their most impaired movements. The subjects completed the training with bilateral symmetry in body recruitment, already present at the end of the familiarization, and they increased the forearm activity. The instrumental evaluation confirmed this. The elbow motion’s angular amplitude improved for all subjects, and other kinematic parameters showed a trend towards the normality range. Conclusion: The outcomes are preliminary evidence supporting the efficacy of the proposed BoMI as a rehabilitation tool to be considered for clinical practice. It also suggests an instrumental evaluation protocol and a set of indicators to assess and evaluate motor impairment and recovery in cSCI.


  • Open Access

    Exoskeleton for Gait Rehabilitation: Effects of Assistance, Mechanical Structure, and Walking Aids on Muscle Activations

    by Alice De Luca, Amy Bellitto, Sergio Mandraccia, Giorgia Marchesi, Laura Pellegrino, Martina Coscia, Clara Leoncini, Laura Rossi, Simona Gamba, Antonino Massone, et al.

    Several exoskeletons have been developed and increasingly used in clinical settings for training and assisting locomotion. These devices allow people with severe motor deficits to regain mobility and sustain intense and repetitive gait training. However, three factors might affect normal muscle activations during walking: the assistive forces that are provided during walking, the crutches or walker that are always used in combination with the device, and the mechanical structure of the device itself. To investigate these effects, we evaluated eight healthy volunteers walking with the Ekso, which is a battery-powered, wearable exoskeleton. They walked supported by either crutches or a walker under five different assistance modalities: bilateral maximum assistance, no assistance, bilateral adaptive assistance, and unilateral adaptive assistance on each leg. Participants also walked overground without the exoskeleton. Surface electromyography was recorded bilaterally, and the statistical parametric mapping approach and muscle synergies analysis were used to investigate differences in muscular activity across different walking conditions. The lower limb muscle activations while walking with the Ekso were not influenced by the use of crutches or walker aids. Compared to normal walking without robotic assistance, the Ekso reduced the amplitude of activation for the distal lower limb muscles while changing the timing for the others. This depended mainly on the structure of the device, and not on the type or level of assistance. In fact, the presence of assistance did not change the timing of the muscle activations, but instead mainly had the effect of increasing the level of activation of the proximal lower limb muscles. Surprisingly, we found no significant changes in the adaptive control with respect to a maximal fixed assistance that did not account for subjects’ performance. These are important effects to take into careful considerations in clinics where these devices are used for gait rehabilitation in people with neurological diseases.