Mohammed S. M. Elbaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammed S. M. Elbaz has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
Michael Markl
Radiology Northwestern University Chicago Illinois USA
11 shared publications- Rob J. van der Geest
Division of Image Processing, Department of Radiology, Leiden University Medical Centre, 2333 Leiden, The Netherlands
10 shared publications James Carr
Radiology Northwestern University Chicago Illinois USA
7 shared publicationsJos J.M. Westenberg
Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
6 shared publications- Pankaj Garg
University of East Anglia, Norwich, UK
6 shared publications Albert de Roos
Department of Radiology, Leiden University Medical Center, Albinusdreef 2, ZA Leiden, The Netherlands
5 shared publications
Latest Publications
- Open Access
DarkSPARC: Dark-Blood Spectral Self-Calibrated Reconstruction of 3D Left Atrial LGE MRI for Post-Ablation Scar Imaging
Purpose: To develop DarkSPARC, a retrospective, training-free, self-calibrated spectral reconstruction method that converts routine bright-blood 3D left atrial (LA) late gadolinium enhancement (LGE) MRI into a dark-blood image, and to quantify its impact on LA scar-pool CNR, SNR, effective CNR (eCNR), and scar quantification accuracy. Methods: DarkSPARC embeds bright-blood LA LGE into a calibrator-conditioned (N+1)-dimensional spectral domain and reconstructs a dark-blood-like image using scan-specific spectral landmarks. A scan-specific 3D numerical phantom framework was built from LAScarQS post-ablation LGE by cloning remote myocardium into the LA wall and imposing controlled scar burden. Five baseline cases spanning the 5th-95th percentiles of native scar-pool CNR, each with multiple scar burdens and 10 CNR degradation levels, yielded 200 phantoms. For every phantom, LA scar-pool CNR, SNR, eCNR, and Scar% were measured on bright-blood and DarkSPARC images. In vivo performance was evaluated in 60 public post-ablation scans of atrial fibrillation patients. Results: In scan-specific phantoms, DarkSPARC increased LA scar-pool CNR, SNR, and eCNR over bright-blood in all 200 experiments, with DarkSPARC/bright-blood ratios up to about 30-fold for CNR and about 6-fold for SNR in the lowest-CNR conditions. At 70% CNR degradation, bright-blood underestimated ground-truth LA Scar% by -37% to -54%, whereas DarkSPARC reduced bias to about -3% to -5%. In vivo, DarkSPARC similarly improved metrics: median scar-pool CNR, SNR, and eCNR increased from 20.0 to 135.9 (6.8x), 70.6 to 200.6 (2.8x), and 0.22 to 0.75 (3.4x), respectively (all p<0.001), and LA Scar% increased from 3.9% to 9.75%. Conclusion: DarkSPARC is a self-calibrated, training-free reconstruction that yields dark-blood 3D LA LGE, boosting CNR/SNR/eCNR and stabilizing reliable scar quantification without extra scans.
Open AccessDarkSPARC: Dark-Blood Spectral Self-Calibrated Reconstruction of 3D Left Atrial LGE MRI for Post-Ablation Scar Imaging
Purpose: To develop DarkSPARC, a retrospective, training-free, self-calibrated spectral reconstruction method that converts routine bright-blood 3D left atrial (LA) late gadolinium enhancement (LGE) MRI into a dark-blood image, and to quantify its impact on LA scar-pool CNR, SNR, effective CNR (eCNR), and scar quantification accuracy. Methods: DarkSPARC embeds bright-blood LA LGE into a calibrator-conditioned (N+1)-dimensional spectral domain and reconstructs a dark-blood-like image using scan-specific spectral landmarks. A scan-specific 3D numerical phantom framework was built from LAScarQS post-ablation LGE by cloning remote myocardium into the LA wall and imposing controlled scar burden. Five baseline cases spanning the 5th-95th percentiles of native scar-pool CNR, each with multiple scar burdens and 10 CNR degradation levels, yielded 200 phantoms. For every phantom, LA scar-pool CNR, SNR, eCNR, and Scar% were measured on bright-blood and DarkSPARC images. In vivo performance was evaluated in 60 public post-ablation scans of atrial fibrillation patients. Results: In scan-specific phantoms, DarkSPARC increased LA scar-pool CNR, SNR, and eCNR over bright-blood in all 200 experiments, with DarkSPARC/bright-blood ratios up to about 30-fold for CNR and about 6-fold for SNR in the lowest-CNR conditions. At 70% CNR degradation, bright-blood underestimated ground-truth LA Scar% by -37% to -54%, whereas DarkSPARC reduced bias to about -3% to -5%. In vivo, DarkSPARC similarly improved metrics: median scar-pool CNR, SNR, and eCNR increased from 20.0 to 135.9 (6.8x), 70.6 to 200.6 (2.8x), and 0.22 to 0.75 (3.4x), respectively (all p<0.001), and LA Scar% increased from 3.9% to 9.75%. Conclusion: DarkSPARC is a self-calibrated, training-free reconstruction that yields dark-blood 3D LA LGE, boosting CNR/SNR/eCNR and stabilizing reliable scar quantification without extra scans.
- Open Access
PathCo-LatticE: Pathology-Constrained Lattice-Of Experts Framework for Fully-supervised Few-Shot Cardiac MRI Segmentation
Few-shot learning (FSL) mitigates data scarcity in cardiac MRI segmentation but typically relies on semi-supervised techniques sensitive to domain shifts and validation bias, restricting zero-shot generalizability. We propose PathCo-LatticE, a fully supervised FSL framework that replaces unlabeled data with pathology-guided synthetic supervision. First, our Virtual Patient Engine models continuous latent disease trajectories from sparse clinical anchors, using generative modeling to synthesize physiologically plausible, fully labeled 3D cohorts. Second, Self-Reinforcing Interleaved Validation (SIV) provides a leakage-free protocol that evaluates models online with progressively challenging synthetic samples, eliminating the need for real validation data. Finally, a dynamic Lattice-of-Experts (LoE) organizes specialized networks within a pathology-aware topology and activates the most relevant experts per input, enabling robust zero-shot generalization to unseen data without target-domain fine-tuning. We evaluated PathCo-LatticE in a strict out-of-distribution (OOD) setting, deriving all anchors and severity statistics from a single-source domain (ACDC) and performing zero-shot testing on the multi-center, multi-vendor M&Ms dataset. PathCo-LatticE outperforms four state-of-the-art FSL methods by 4.2-11% Dice starting from only 7 labeled anchors, and approaches fully supervised performance (within 1% Dice) with only 19 labeled anchors. The method shows superior harmonization across four vendors and generalization to unseen pathologies. [Code will be made publicly available].
Open AccessPathCo-LatticE: Pathology-Constrained Lattice-Of Experts Framework for Fully-supervised Few-Shot Cardiac MRI Segmentation
Few-shot learning (FSL) mitigates data scarcity in cardiac MRI segmentation but typically relies on semi-supervised techniques sensitive to domain shifts and validation bias, restricting zero-shot generalizability. We propose PathCo-LatticE, a fully supervised FSL framework that replaces unlabeled data with pathology-guided synthetic supervision. First, our Virtual Patient Engine models continuous latent disease trajectories from sparse clinical anchors, using generative modeling to synthesize physiologically plausible, fully labeled 3D cohorts. Second, Self-Reinforcing Interleaved Validation (SIV) provides a leakage-free protocol that evaluates models online with progressively challenging synthetic samples, eliminating the need for real validation data. Finally, a dynamic Lattice-of-Experts (LoE) organizes specialized networks within a pathology-aware topology and activates the most relevant experts per input, enabling robust zero-shot generalization to unseen data without target-domain fine-tuning. We evaluated PathCo-LatticE in a strict out-of-distribution (OOD) setting, deriving all anchors and severity statistics from a single-source domain (ACDC) and performing zero-shot testing on the multi-center, multi-vendor M&Ms dataset. PathCo-LatticE outperforms four state-of-the-art FSL methods by 4.2-11% Dice starting from only 7 labeled anchors, and approaches fully supervised performance (within 1% Dice) with only 19 labeled anchors. The method shows superior harmonization across four vendors and generalization to unseen pathologies. [Code will be made publicly available].
- Open Access
Stochastic Entanglement Configuration for Constructive Entanglement Topologies in Quantum Machine Learning with Application to Cardiac MRI
Efficient entanglement strategies are essential for advancing variational quantum circuits (VQCs) for quantum machine learning (QML). However, most current approaches use fixed entanglement topologies that are not adaptive to task requirements, limiting potential gains over classical models. We introduce a novel stochastic entanglement configuration method that systematically generates diverse entanglement topologies to identify a subspace of constructive entanglement configurations, defined as entanglement topologies that boost hybrid model performance (e.g., classification accuracy) beyond classical baselines. Each configuration is encoded as a stochastic binary matrix, denoting directed entanglement between qubits. This enables scalable exploration of the hyperspace of candidate entanglement topologies using entanglement density and per-qubit constraints as key metrics. We define unconstrained and constrained sampling modes, controlling entanglement per qubit. Using our method, 400 stochastic configurations were generated and evaluated in a hybrid QML for cardiac MRI disease classification. We identified 64 (16%) novel constructive entanglement configurations that consistently outperformed the classical baseline. Ensemble aggregation of top-performing configurations achieved ~0.92 classification accuracy, exceeding the classical model (~0.87) by over 5%. Compared to four conventional topologies (ring, nearest neighbor, no entanglement, fully entangled), none surpassed the classical baseline (maximum accuracy ~0.82), while our configurations delivered up to ~20% higher accuracy. Thus, highlighting the robustness and generalizability of the identified constructive entanglements.
Open AccessStochastic Entanglement Configuration for Constructive Entanglement Topologies in Quantum Machine Learning with Application to Cardiac MRI
Efficient entanglement strategies are essential for advancing variational quantum circuits (VQCs) for quantum machine learning (QML). However, most current approaches use fixed entanglement topologies that are not adaptive to task requirements, limiting potential gains over classical models. We introduce a novel stochastic entanglement configuration method that systematically generates diverse entanglement topologies to identify a subspace of constructive entanglement configurations, defined as entanglement topologies that boost hybrid model performance (e.g., classification accuracy) beyond classical baselines. Each configuration is encoded as a stochastic binary matrix, denoting directed entanglement between qubits. This enables scalable exploration of the hyperspace of candidate entanglement topologies using entanglement density and per-qubit constraints as key metrics. We define unconstrained and constrained sampling modes, controlling entanglement per qubit. Using our method, 400 stochastic configurations were generated and evaluated in a hybrid QML for cardiac MRI disease classification. We identified 64 (16%) novel constructive entanglement configurations that consistently outperformed the classical baseline. Ensemble aggregation of top-performing configurations achieved ~0.92 classification accuracy, exceeding the classical model (~0.87) by over 5%. Compared to four conventional topologies (ring, nearest neighbor, no entanglement, fully entangled), none surpassed the classical baseline (maximum accuracy ~0.82), while our configurations delivered up to ~20% higher accuracy. Thus, highlighting the robustness and generalizability of the identified constructive entanglements.
- Open Access
Assessing Foundational Medical 'Segment Anything' (Med-SAM1, Med-SAM2) Deep Learning Models for Left Atrial Segmentation in 3D LGE MRI
Atrial fibrillation (AF), the most common cardiac arrhythmia, is associated with heart failure and stroke. Accurate segmentation of the left atrium (LA) in 3D late gadolinium-enhanced (LGE) MRI is helpful for evaluating AF, as fibrotic remodeling in the LA myocardium contributes to arrhythmia and serves as a key determinant of therapeutic strategies. However, manual LA segmentation is labor-intensive and challenging. Recent foundational deep learning models, such as the Segment Anything Model (SAM), pre-trained on diverse datasets, have demonstrated promise in generic segmentation tasks. MedSAM, a fine-tuned version of SAM for medical applications, enables efficient, zero-shot segmentation without domain-specific training. Despite the potential of MedSAM model, it has not yet been evaluated for the complex task of LA segmentation in 3D LGE-MRI. This study aims to (1) evaluate the performance of MedSAM in automating LA segmentation, (2) compare the performance of the MedSAM2 model, which uses a single prompt with automated tracking, with the MedSAM1 model, which requires separate prompt for each slice, and (3) analyze the performance of MedSAM1 in terms of Dice score(i.e., segmentation accuracy) by varying the size and location of the box prompt.
Open AccessAssessing Foundational Medical 'Segment Anything' (Med-SAM1, Med-SAM2) Deep Learning Models for Left Atrial Segmentation in 3D LGE MRI
Atrial fibrillation (AF), the most common cardiac arrhythmia, is associated with heart failure and stroke. Accurate segmentation of the left atrium (LA) in 3D late gadolinium-enhanced (LGE) MRI is helpful for evaluating AF, as fibrotic remodeling in the LA myocardium contributes to arrhythmia and serves as a key determinant of therapeutic strategies. However, manual LA segmentation is labor-intensive and challenging. Recent foundational deep learning models, such as the Segment Anything Model (SAM), pre-trained on diverse datasets, have demonstrated promise in generic segmentation tasks. MedSAM, a fine-tuned version of SAM for medical applications, enables efficient, zero-shot segmentation without domain-specific training. Despite the potential of MedSAM model, it has not yet been evaluated for the complex task of LA segmentation in 3D LGE-MRI. This study aims to (1) evaluate the performance of MedSAM in automating LA segmentation, (2) compare the performance of the MedSAM2 model, which uses a single prompt with automated tracking, with the MedSAM1 model, which requires separate prompt for each slice, and (3) analyze the performance of MedSAM1 in terms of Dice score(i.e., segmentation accuracy) by varying the size and location of the box prompt.
- Open Access
- 28 October 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (5) , 2130-2143
3D Vortex‐Energetics in the Left Pulmonary Artery for Differentiating Pulmonary Arterial Hypertension and Pulmonary Venous Hypertension Groups Using 4D Flow MRI
Background: Pulmonary hypertension (PH) is a life‐threatening. Differentiation pulmonary arterial hypertension (PAH) from pulmonary venous hypertension (PVH) is important due to distinct treatment protocols. Invasive right heart catheterization (RHC) remains the reference standard but noninvasive alternatives are needed.Purpose/Hypothesis: To evaluate 4D Flow MRI‐derived 3D vortex energetics in the left pulmonary artery (LPA) for distinguishing PAH from PVH.Study Type: Prospective case–control.Population/Subjects: Fourteen PAH patients (11 female) and 18 PVH patients (9 female) diagnosed from RHC, 23 healthy controls (9 female).Field Strength/Sequence: 1.5 T; gradient recalled echo 4D flow and balanced steady‐state free precession (bSSFP) cardiac cine sequences.Assessment: LPA 3D vortex cores were identified using the lambda2 method. Peak vortex‐contained kinetic energy (vortex‐KE) and viscous energy loss (vortex‐EL) were computed from 4D flow MRI. Left and right ventricular (LV, RV) stroke volume (LVSV, RVSV) and ejection fraction (LVEF, RVEF) were computed from bSSFP. In PH patients, mean pulmonary artery pressure (mPAP), pulmonary capillary wedge pressure (PCWR) and pulmonary vascular resistance (PVR) were determined from RHC.Statistical Tests: Mann–Whitney U test for group comparisons, Spearman's rho for correlations, logistic regression for identifying predictors of PAH vs. PVH and develop models, area under the receiver operating characteristic curve (AUC) for model performance. Significance was set at P < 0.05.Results: PAH patients showed significantly lower vortex‐KE (37.14 [14.68–78.52] vs. 76.48 [51.07–120.51]) and vortex‐EL (9.93 [5.69–25.70] vs. 24.22 [12.20–32.01]) than PVH patients. The combined vortex‐KE and LVEF model achieved an AUC of 0.89 for differentiating PAH from PVH. Vortex‐EL showed significant negative correlations with mPAP (rho = −0.43), PCWP (rho = 0.37), PVR (rho = −0.64). In the PAH group, PVR was significantly negatively correlated with LPA vortex‐KE (rho = −0.73) and vortex‐EL (rho = −0.71), and vortex‐KE significantly correlated with RVEF (rho = 0.69), RVSV, (rho = 0.70). In the PVH group, vortex‐KE (rho = 0.52), vortex‐EL significantly correlated with RVSV (rho = 0.58).Data Conclusion: These preliminary findings suggest that 4D flow MRI‐derived LPA vortex energetics have potential to noninvasively differentiate PAH from PVH and correlate with invasive hemodynamic parameters.Evidence Level: 1Technical Efficacy: Stage 3
- 28 October 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (5) , 2130-2143
Open Access3D Vortex‐Energetics in the Left Pulmonary Artery for Differentiating Pulmonary Arterial Hypertension and Pulmonary Venous Hypertension Groups Using 4D Flow MRI
Background: Pulmonary hypertension (PH) is a life‐threatening. Differentiation pulmonary arterial hypertension (PAH) from pulmonary venous hypertension (PVH) is important due to distinct treatment protocols. Invasive right heart catheterization (RHC) remains the reference standard but noninvasive alternatives are needed.Purpose/Hypothesis: To evaluate 4D Flow MRI‐derived 3D vortex energetics in the left pulmonary artery (LPA) for distinguishing PAH from PVH.Study Type: Prospective case–control.Population/Subjects: Fourteen PAH patients (11 female) and 18 PVH patients (9 female) diagnosed from RHC, 23 healthy controls (9 female).Field Strength/Sequence: 1.5 T; gradient recalled echo 4D flow and balanced steady‐state free precession (bSSFP) cardiac cine sequences.Assessment: LPA 3D vortex cores were identified using the lambda2 method. Peak vortex‐contained kinetic energy (vortex‐KE) and viscous energy loss (vortex‐EL) were computed from 4D flow MRI. Left and right ventricular (LV, RV) stroke volume (LVSV, RVSV) and ejection fraction (LVEF, RVEF) were computed from bSSFP. In PH patients, mean pulmonary artery pressure (mPAP), pulmonary capillary wedge pressure (PCWR) and pulmonary vascular resistance (PVR) were determined from RHC.Statistical Tests: Mann–Whitney U test for group comparisons, Spearman's rho for correlations, logistic regression for identifying predictors of PAH vs. PVH and develop models, area under the receiver operating characteristic curve (AUC) for model performance. Significance was set at P < 0.05.Results: PAH patients showed significantly lower vortex‐KE (37.14 [14.68–78.52] vs. 76.48 [51.07–120.51]) and vortex‐EL (9.93 [5.69–25.70] vs. 24.22 [12.20–32.01]) than PVH patients. The combined vortex‐KE and LVEF model achieved an AUC of 0.89 for differentiating PAH from PVH. Vortex‐EL showed significant negative correlations with mPAP (rho = −0.43), PCWP (rho = 0.37), PVR (rho = −0.64). In the PAH group, PVR was significantly negatively correlated with LPA vortex‐KE (rho = −0.73) and vortex‐EL (rho = −0.71), and vortex‐KE significantly correlated with RVEF (rho = 0.69), RVSV, (rho = 0.70). In the PVH group, vortex‐KE (rho = 0.52), vortex‐EL significantly correlated with RVSV (rho = 0.58).Data Conclusion: These preliminary findings suggest that 4D flow MRI‐derived LPA vortex energetics have potential to noninvasively differentiate PAH from PVH and correlate with invasive hemodynamic parameters.Evidence Level: 1Technical Efficacy: Stage 3
- Open Access
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (3) , 856-869
Novel Self-Calibrated Threshold-Free Probabilistic Fibrosis Signature Technique for 3D Late Gadolinium Enhancement MRI
Myocardial fibrosis is a crucial marker of heart muscle injury in several heart disease like myocardial infarction, cardiomyopathies, and atrial fibrillation (AF). Fibrosis and associated scarring (dense fibrosis) are also vital for assessing heart muscle pre- and post-intervention, such as evaluating left atrial (LA) fibrosis/scarring in patients undergoing catheter ablation for AF. Although cardiac MRI is the gold standard for fibrosis assessment, current quantification methods are unreliable due to their reliance on variable thresholding and sensitivity to MRI uncertainties, lacking standardization and reproducibility. Importantly, current methods focus solely on quantifying fibrosis volume ignoring the unique MRI characteristics of fibrosis density and unique distribution, that could better inform on disease severity. To address these issues, we propose a novel threshold-free self-calibrating probabilistic method called “Fibrosis Signatures.” This method efficiently encodes ∼9 billion MRI intensity co-disparities per scan into standardized probability density functions, deriving a unique MRI fibrosis signature index (FSI). The FSI index quantitatively encodes fibrosis/scar extent, density, and distribution patterns simultaneously, providing a detailed assessment of burden/severity. Our self-calibrating design mitigates impacts of MRI uncertainties, ensuring robust evaluations pre- and post-intervention under varying MRI qualities. Extensively validated using a novel numerical phantom and 143 in vivo LA 3D MRIs of AF patients (pre- and post- ablation and serial post-ablation scans) and compared to 5 existing methods, our FSI index demonstrated strong correlations with traditional fibrosis measures and was able to quantify density and distribution pattern beyond entropy. FSI was up to 9 times more reliable and reproducible to MRI uncertainties (noise, segmentation, spatial resolution), highlighting its potential to improve cardiac MRI reliability and clinical utility.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (3) , 856-869
Open AccessNovel Self-Calibrated Threshold-Free Probabilistic Fibrosis Signature Technique for 3D Late Gadolinium Enhancement MRI
Myocardial fibrosis is a crucial marker of heart muscle injury in several heart disease like myocardial infarction, cardiomyopathies, and atrial fibrillation (AF). Fibrosis and associated scarring (dense fibrosis) are also vital for assessing heart muscle pre- and post-intervention, such as evaluating left atrial (LA) fibrosis/scarring in patients undergoing catheter ablation for AF. Although cardiac MRI is the gold standard for fibrosis assessment, current quantification methods are unreliable due to their reliance on variable thresholding and sensitivity to MRI uncertainties, lacking standardization and reproducibility. Importantly, current methods focus solely on quantifying fibrosis volume ignoring the unique MRI characteristics of fibrosis density and unique distribution, that could better inform on disease severity. To address these issues, we propose a novel threshold-free self-calibrating probabilistic method called “Fibrosis Signatures.” This method efficiently encodes ∼9 billion MRI intensity co-disparities per scan into standardized probability density functions, deriving a unique MRI fibrosis signature index (FSI). The FSI index quantitatively encodes fibrosis/scar extent, density, and distribution patterns simultaneously, providing a detailed assessment of burden/severity. Our self-calibrating design mitigates impacts of MRI uncertainties, ensuring robust evaluations pre- and post-intervention under varying MRI qualities. Extensively validated using a novel numerical phantom and 143 in vivo LA 3D MRIs of AF patients (pre- and post- ablation and serial post-ablation scans) and compared to 5 existing methods, our FSI index demonstrated strong correlations with traditional fibrosis measures and was able to quantify density and distribution pattern beyond entropy. FSI was up to 9 times more reliable and reproducible to MRI uncertainties (noise, segmentation, spatial resolution), highlighting its potential to improve cardiac MRI reliability and clinical utility.
- Open Access
- 15 December 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 92, 103065
Robust and fast stochastic 4D flow vector-field signature technique for quantifying composite flow dynamics from 4D flow MRI: Application to left atrial flow in atrial fibrillation
- 15 December 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 92, 103065
Open AccessRobust and fast stochastic 4D flow vector-field signature technique for quantifying composite flow dynamics from 4D flow MRI: Application to left atrial flow in atrial fibrillation
- Open Access
- 6 December 2021
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 23 (1) , 138-13
Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
- 6 December 2021
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 23 (1) , 138-13
Open AccessDirect mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR
- 21 September 2021
- Published by Springer Nature
- p. 215-224
Stochastic 4D Flow Vector-Field Signatures: A New Approach for Comprehensive 4D Flow MRI Quantification
- 21 September 2021
- Published by Springer Nature
- p. 215-224
Stochastic 4D Flow Vector-Field Signatures: A New Approach for Comprehensive 4D Flow MRI Quantification
- 1 April 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 320 (4) , H1687-H1698
Hemodynamic interplay of vorticity, viscous energy loss, and kinetic energy from 4D Flow MRI and link to cardiac function in healthy subjects and Fontan patients
The purpose of this study was to directly assess (patho)physiology of intraventricular hemodynamic interplay between four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI)-derived vorticity with kinetic energy (KE) and viscous energy loss (EL) over the cardiac cycle and their association to ejection fraction (EF) and stroke volume (SV). Fifteen healthy subjects and thirty Fontan patients underwent whole heart 4D Flow MRI. Ventricular vorticity, KE, and EL were computed over systole (vorticity_volavg systole, KEavg systole, and ELavg systole) and diastole (vorticity_volavg diastole, KEavg diastole, and ELavg diastole). The association between vorticity_vol and KE and EL was tested by Spearman correlation. Fontan patients were grouped to normal and impaired EF groups. A significant correlation was found between SV and vorticity in healthy subjects (systolic: ρ = 0.84, P < 0.001; diastolic: ρ = 0.81, P < 0.001) and in Fontan patients (systolic: ρ = 0.61, P < 0.001; diastolic: ρ = 0.54, P = 0.002). Healthy subjects showed positive correlation between vorticity_vol versus KE (systole: ρ = 0.96, P < 0.001; diastole: ρ = 0.90, P < 0.001) and EL (systole: ρ = 0.85, P < 0.001; diastole: ρ = 0.84, P < 0.001). Fontan patients showed significantly elevated vorticity_vol compared with healthy subjects (vorticity_volavg systole: 3.1 [2.3–3.9] vs. 1.7 [1.3–2.4] L/s, P < 0.001; vorticity_volavg diastole: 3.1 [2.0–3.7] vs. 2.1 [1.6–2.8] L/s, P = 0.002). This elevated vorticity in Fontan patients showed strong association with KE (systole: ρ = 0.91, P < 0.001; diastole: ρ = 0.85, P < 0.001) and EL (systole: ρ = 0.82, P < 0.001; diastole: ρ = 0.89, P < 0.001). Fontan patients with normal EF showed significantly higher vorticity_volavg systole and ELavg systole, but significantly decreased KE avg diastole, in the presence of normal SV, compared with healthy subjects. Healthy subjects show strong physiological hemodynamic interplay between vorticity with KE and EL. Fontan patients demonstrate a pathophysiological hemodynamic interplay characterized by correlation of elevated vorticity with KE and EL in the presence of maintained normal stroke volume. Altered vorticity and energetic hemodynamics are found in the presence of normal EF in Fontan patients. NEW & NOTEWORTHY Physiologic intraventricular hemodynamic interplay/coupling is present in the healthy left ventricle between vorticity versus viscous energy loss and kinetic energy from four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI). Conversely, Fontan patients present compensatory pathophysiologic hemodynamic coupling by an increase in intraventricular vorticity that positively correlates to viscous energy loss and kinetic energy levels in the presence of maintained normal stroke volume. Altered vorticity and energetics are found in the presence of normal ejection fraction in Fontan patients.
- 1 April 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 320 (4) , H1687-H1698
Hemodynamic interplay of vorticity, viscous energy loss, and kinetic energy from 4D Flow MRI and link to cardiac function in healthy subjects and Fontan patients
The purpose of this study was to directly assess (patho)physiology of intraventricular hemodynamic interplay between four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI)-derived vorticity with kinetic energy (KE) and viscous energy loss (EL) over the cardiac cycle and their association to ejection fraction (EF) and stroke volume (SV). Fifteen healthy subjects and thirty Fontan patients underwent whole heart 4D Flow MRI. Ventricular vorticity, KE, and EL were computed over systole (vorticity_volavg systole, KEavg systole, and ELavg systole) and diastole (vorticity_volavg diastole, KEavg diastole, and ELavg diastole). The association between vorticity_vol and KE and EL was tested by Spearman correlation. Fontan patients were grouped to normal and impaired EF groups. A significant correlation was found between SV and vorticity in healthy subjects (systolic: ρ = 0.84, P < 0.001; diastolic: ρ = 0.81, P < 0.001) and in Fontan patients (systolic: ρ = 0.61, P < 0.001; diastolic: ρ = 0.54, P = 0.002). Healthy subjects showed positive correlation between vorticity_vol versus KE (systole: ρ = 0.96, P < 0.001; diastole: ρ = 0.90, P < 0.001) and EL (systole: ρ = 0.85, P < 0.001; diastole: ρ = 0.84, P < 0.001). Fontan patients showed significantly elevated vorticity_vol compared with healthy subjects (vorticity_volavg systole: 3.1 [2.3–3.9] vs. 1.7 [1.3–2.4] L/s, P < 0.001; vorticity_volavg diastole: 3.1 [2.0–3.7] vs. 2.1 [1.6–2.8] L/s, P = 0.002). This elevated vorticity in Fontan patients showed strong association with KE (systole: ρ = 0.91, P < 0.001; diastole: ρ = 0.85, P < 0.001) and EL (systole: ρ = 0.82, P < 0.001; diastole: ρ = 0.89, P < 0.001). Fontan patients with normal EF showed significantly higher vorticity_volavg systole and ELavg systole, but significantly decreased KE avg diastole, in the presence of normal SV, compared with healthy subjects. Healthy subjects show strong physiological hemodynamic interplay between vorticity with KE and EL. Fontan patients demonstrate a pathophysiological hemodynamic interplay characterized by correlation of elevated vorticity with KE and EL in the presence of maintained normal stroke volume. Altered vorticity and energetic hemodynamics are found in the presence of normal EF in Fontan patients. NEW & NOTEWORTHY Physiologic intraventricular hemodynamic interplay/coupling is present in the healthy left ventricle between vorticity versus viscous energy loss and kinetic energy from four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI). Conversely, Fontan patients present compensatory pathophysiologic hemodynamic coupling by an increase in intraventricular vorticity that positively correlates to viscous energy loss and kinetic energy levels in the presence of maintained normal stroke volume. Altered vorticity and energetics are found in the presence of normal ejection fraction in Fontan patients.