Thibault Prevost
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thibault Prevost has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Frédéric Colas
EA 2697, L2EP, Laboratoire d’Electrotechnique et d’Electronique de Puissance, HEI, Centrale Lille, Arts et Metiers Paris Tech, Univ. Lille, F-59000 Lille, France
6 shared publications - Xavier Guillaud
Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) Ecole Centrale de Lille Cité Scientifique CS Villeneuve d'Ascq 20048 59651 Hauts-de-France France
6 shared publications - Yorgo Laba
Centrale Lille, Arts et Mtiers Institute of Technology, Junia ULR 2697L2EP Universit de Lille, Lille, France
3 shared publications - Antoine Bruyère
Centrale Lille, Arts et Mtiers Institute of Technology, Junia ULR 2697L2EP Universit de Lille, Lille, France
2 shared publications - Carmen Cardozo
R&D division, Réseau de Transport d’Électricité, La Défense, France
2 shared publications - Francois Gruson
L2EP, Arts et Métiers, ParisTech, 8Bd Louis XIV, 59046 Lille, France
2 shared publications
Latest Publications
- 3 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 263
Voltage control grid-forming for enhanced large disturbance stability under unbalanced conditions
- 3 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 263
Voltage control grid-forming for enhanced large disturbance stability under unbalanced conditions
- 28 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Placing grid-forming controlled converters to enhance power system small-signal stability
- 28 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Placing grid-forming controlled converters to enhance power system small-signal stability
- 27 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 5945-5957
Enhancing Large Disturbance Stability of Direct Voltage Grid-Forming Converters Through Integration of the Virtual Power Method
Grid-Forming control (GFM) plays an increasingly crucial role in modern power grids by ensuring stability and providing inertia, keeping the voltage waveform steady and preventing rapid changes. One of the main challenges in GFM is that it operates as a voltage source, making current control challenging. Since power electronics converters have limited capacity, managing current limitation becomes critical. To address this, certain types of grid-forming embed a current loop (CCGFM); therefore, limiting the current reference can effectively control the current. Despite its effectiveness, a significant issue arises in post-fault states, where current limitation can decrease the stability margin and restrict synchronization. To overcome this challenge, a virtual power-based method has been proposed, which decouples synchronization angle control from current limitation by employing unsaturated current references for power measurement. While effective, continuous current control has been found to reduce the small-signal stability of the system. This paper presents a novel hybrid architecture of Voltage Control Grid-Forming (VCGFM) that improves stability under large disturbances by incorporating the virtual power approach from CCGFM while taking advantage of the small-signal stability superiority of the classical VCGFM by eliminating the impact of current control during normal operation. The proposed method is further validated through experimental testing.
- 27 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 5945-5957
Enhancing Large Disturbance Stability of Direct Voltage Grid-Forming Converters Through Integration of the Virtual Power Method
Grid-Forming control (GFM) plays an increasingly crucial role in modern power grids by ensuring stability and providing inertia, keeping the voltage waveform steady and preventing rapid changes. One of the main challenges in GFM is that it operates as a voltage source, making current control challenging. Since power electronics converters have limited capacity, managing current limitation becomes critical. To address this, certain types of grid-forming embed a current loop (CCGFM); therefore, limiting the current reference can effectively control the current. Despite its effectiveness, a significant issue arises in post-fault states, where current limitation can decrease the stability margin and restrict synchronization. To overcome this challenge, a virtual power-based method has been proposed, which decouples synchronization angle control from current limitation by employing unsaturated current references for power measurement. While effective, continuous current control has been found to reduce the small-signal stability of the system. This paper presents a novel hybrid architecture of Voltage Control Grid-Forming (VCGFM) that improves stability under large disturbances by incorporating the virtual power approach from CCGFM while taking advantage of the small-signal stability superiority of the classical VCGFM by eliminating the impact of current control during normal operation. The proposed method is further validated through experimental testing.
- 18 April 2025
- Published by Elsevier in Signal Processing
- Vol. 236
Multiple-model coding scheme for electrical signal compression
- 18 April 2025
- Published by Elsevier in Signal Processing
- Vol. 236
Multiple-model coding scheme for electrical signal compression
- Top Cited Papers
- 15 July 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 235
Promises and challenges of grid forming: Transmission system operator, manufacturer and academic view points
- 15 July 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 235
Top Cited PapersPromises and challenges of grid forming: Transmission system operator, manufacturer and academic view points
- Top Cited Papers
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 22 (2) , 18-29
Grid-Forming Inverter-Based Resource Research Landscape: Understanding the Key Assets for Renewable-Rich Power Systems
The shift to net zero energy systems has changed the face of our power grid. Traditional large-scale synchronous generators found inside coal and natural gas plants are being replaced with inverter-based resource (IBR) technologies. This transition to an IBR-dominant power grid introduces new characteristics, altering how our grid operates. Therefore, the role of IBRs has expanded, requiring them to provide a range of essential services to keep our grid reliable, resilient, and secure.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 22 (2) , 18-29
Top Cited PapersGrid-Forming Inverter-Based Resource Research Landscape: Understanding the Key Assets for Renewable-Rich Power Systems
The shift to net zero energy systems has changed the face of our power grid. Traditional large-scale synchronous generators found inside coal and natural gas plants are being replaced with inverter-based resource (IBR) technologies. This transition to an IBR-dominant power grid introduces new characteristics, altering how our grid operates. Therefore, the role of IBRs has expanded, requiring them to provide a range of essential services to keep our grid reliable, resilient, and secure.
- Open Access
Enhanced TVI for Grid Forming VSC under Unbalanced Faults
With an increasing capacity of inverter-based generation and with a 100% renewable energy power system on the horizon, grid forming converters have the potential to become the prevalent control mode in the grid. Thus, the correct performance of these devices is going to be crucial for system stability and security of supply. Most research related to the grid-forming control is focused on normal operating conditions, although significant effort has been devoted to current limitation strategies to ensure Low Voltage Ride Through (LVRT) capability. However, most contributions usually consider only balanced faults. This paper, proposes a new current limiting method based on the well-known threshold virtual impedance (TVI) that keeps the voltage source behaviour associated to the grid forming (GFM) capability, even when the current limit is reached, while reducing the voltage unbalance according to user-defined settings.
Open AccessEnhanced TVI for Grid Forming VSC under Unbalanced Faults
With an increasing capacity of inverter-based generation and with a 100% renewable energy power system on the horizon, grid forming converters have the potential to become the prevalent control mode in the grid. Thus, the correct performance of these devices is going to be crucial for system stability and security of supply. Most research related to the grid-forming control is focused on normal operating conditions, although significant effort has been devoted to current limitation strategies to ensure Low Voltage Ride Through (LVRT) capability. However, most contributions usually consider only balanced faults. This paper, proposes a new current limiting method based on the well-known threshold virtual impedance (TVI) that keeps the voltage source behaviour associated to the grid forming (GFM) capability, even when the current limit is reached, while reducing the voltage unbalance according to user-defined settings.
- 30 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2209-2219
Implementation and Validation of a Model Predictive Controller on a Lab-Scale Three-Terminal MTDC Grid
In this paper, a reliable methodology is proposed in order to implement and validate a Model Predictive Control (MPC) scheme on an actual Voltage Source Converter (VSC) integrated in a scale-down multi-terminal DC grid. The objective of the investigated MPC controller is to enable AC frequency support among two asynchronous AC areas through a High Voltage Direct Current (HVDC) grid, while considering physical constraints, such as maximum and minimum DC voltage. A systematic and accurate implementation strategy is proposed, based mainly on the Hardware In the Loop (HIL) and Power Hardware In the Loop (PHIL), leading to the real-life testing on VSC, controlled by a classical microcontroller. The technical problems during the implementation process, as well as the proposed solutions, are described in detail through this paper. This procedure is deemed valuable to bridge the gap between offline simulation and the actual implementation of such advanced control scheme on experimental test rig.
- 30 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2209-2219
Implementation and Validation of a Model Predictive Controller on a Lab-Scale Three-Terminal MTDC Grid
In this paper, a reliable methodology is proposed in order to implement and validate a Model Predictive Control (MPC) scheme on an actual Voltage Source Converter (VSC) integrated in a scale-down multi-terminal DC grid. The objective of the investigated MPC controller is to enable AC frequency support among two asynchronous AC areas through a High Voltage Direct Current (HVDC) grid, while considering physical constraints, such as maximum and minimum DC voltage. A systematic and accurate implementation strategy is proposed, based mainly on the Hardware In the Loop (HIL) and Power Hardware In the Loop (PHIL), leading to the real-life testing on VSC, controlled by a classical microcontroller. The technical problems during the implementation process, as well as the proposed solutions, are described in detail through this paper. This procedure is deemed valuable to bridge the gap between offline simulation and the actual implementation of such advanced control scheme on experimental test rig.
- Top Cited Papers
- 12 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1050-1061
Critical Clearing Time Determination and Enhancement of Grid-Forming Converters Embedding Virtual Impedance as Current Limitation Algorithm
The present paper deals with the post-fault synchronization of a voltage source converter based on the droop control. In case of large disturbances on the grid, the current is limited via current limitation algorithms such as the virtual impedance. During the fault, the power converter internal frequency deviates resulting in a converter angle divergence. Thereby, the system may lose the synchronism after fault clearing and which may lead to instability. Hence, this paper proposes a theoretical approach to explain the dynamic behavior of the grid forming converter subject to a three phase bolted fault. A literal expression of the critical clearing time is defined. Due to the precise analysis of the phenomenon, a simple algorithm can be derived to enhance the transient stability. It is based on adaptive gain included in the droop control. These objectives have been achieved with no external information and without switching from one control to the other. To prove the effectiveness of the developed control, experimental test cases have been performed in different faulted conditions.
- 12 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (2) , 1050-1061
Top Cited PapersCritical Clearing Time Determination and Enhancement of Grid-Forming Converters Embedding Virtual Impedance as Current Limitation Algorithm
The present paper deals with the post-fault synchronization of a voltage source converter based on the droop control. In case of large disturbances on the grid, the current is limited via current limitation algorithms such as the virtual impedance. During the fault, the power converter internal frequency deviates resulting in a converter angle divergence. Thereby, the system may lose the synchronism after fault clearing and which may lead to instability. Hence, this paper proposes a theoretical approach to explain the dynamic behavior of the grid forming converter subject to a three phase bolted fault. A literal expression of the critical clearing time is defined. Due to the precise analysis of the phenomenon, a simple algorithm can be derived to enhance the transient stability. It is based on adaptive gain included in the droop control. These objectives have been achieved with no external information and without switching from one control to the other. To prove the effectiveness of the developed control, experimental test cases have been performed in different faulted conditions.
- 17 July 2019
- Published by Wiley in Wind Energy
- Vol. 22 (10) , 1343-1355
Model‐based control addition to prescribe DFIG wind turbine fast frequency response
- 17 July 2019
- Published by Wiley in Wind Energy
- Vol. 22 (10) , 1343-1355
Model‐based control addition to prescribe DFIG wind turbine fast frequency response