Sergio Levario-Medina
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sergio Levario-Medina has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Gabriel Valencia-Ortega
Universidad Nacional Autónoma de México
5 shared publications - Marco Antonio Barranco-Jiménez
Escuela Superior de Cómputo del Instituto Politécnico Nacional Av. Miguel Bernard Esq. Av. Miguel Othón de Mendizabal Colonia Lindavista 07738 Ciudad de México México
4 shared publications - Luis Antonio Arias-Hernandez
Departamento de Física Escuela Superior de Física y Matemáticas Instituto Politécnico Nacional U. P. Zacatenco edif. #9 2o Piso Ciudad de México 07738 México
2 shared publications - Cv Radhakrishnan
School of Traffic and Transportation Engineering, Central South University, Changsha, China
1 shared publication - Fernando Angulo-Brown
Departamento de Física, Escuela Superior de Física y Matemáticas, Instituto Politécnico Nacional, Ciudad de México 07738, Mexico
1 shared publication
Latest Publications
- 30 July 2024
- Published by Elsevier in Solar Energy
- Vol. 279
Current trends in single-thermodynamic optimization models towards sustainable designs of central concentrating solar plants
- 30 July 2024
- Published by Elsevier in Solar Energy
- Vol. 279
Current trends in single-thermodynamic optimization models towards sustainable designs of central concentrating solar plants
- Open Access
Energetic optimization considering a generalization of the ecological criterion in traditional simple-cycle and combined cycle power plants
The fundamental issue in the energetic performance of power plants, working both as traditional fuel engines and as combined cycle turbine (gas-steam), lies in quantifying the internal irreversibilities which are associated with the working substance operating in cycles. The purpose of several irreversible energy converter models is to find objective thermodynamic functions that determine operation modes for real thermal engines and at the same time study the trade off between energy losses per cycle and the useful energy. As those objective functions, we focus our attention on a generalization of the so-called ecological function in terms of an $\epsilon$--parameter that depends on the particular heat transfer law used in the irreversible heat engine model. In this work, we mathematically describe the configuration space of an irreversible Curzon-Ahlborn type model. The above allows to determine the optimal relations between the model parameters so that a power plant operates in physically accessible regions, taking into account internal irreversibilities, introduced in two different ways (additively and multiplicatively). In addition, we establish the conditions that the $\epsilon$--parameter must fulfill for the energy converter works in an optimal region between maximum power output and maximum efficiency points.
Open AccessEnergetic optimization considering a generalization of the ecological criterion in traditional simple-cycle and combined cycle power plants
The fundamental issue in the energetic performance of power plants, working both as traditional fuel engines and as combined cycle turbine (gas-steam), lies in quantifying the internal irreversibilities which are associated with the working substance operating in cycles. The purpose of several irreversible energy converter models is to find objective thermodynamic functions that determine operation modes for real thermal engines and at the same time study the trade off between energy losses per cycle and the useful energy. As those objective functions, we focus our attention on a generalization of the so-called ecological function in terms of an $\epsilon$--parameter that depends on the particular heat transfer law used in the irreversible heat engine model. In this work, we mathematically describe the configuration space of an irreversible Curzon-Ahlborn type model. The above allows to determine the optimal relations between the model parameters so that a power plant operates in physically accessible regions, taking into account internal irreversibilities, introduced in two different ways (additively and multiplicatively). In addition, we establish the conditions that the $\epsilon$--parameter must fulfill for the energy converter works in an optimal region between maximum power output and maximum efficiency points.
- 1 July 2020
- Published by Walter de Gruyter GmbH in Journal of Non-Equilibrium Thermodynamics
- Vol. 45 (3) , 269-290
Energetic Optimization Considering a Generalization of the Ecological Criterion in Traditional Simple-Cycle and Combined-Cycle Power Plants
The fundamental issue in the energetic performance of power plants, working both as traditional fuel engines and as combined-cycle turbines (gas-steam), lies in quantifying the internal irreversibilities which are associated with the working substance operating in cycles. The purpose of several irreversible energy converter models is to find objective thermodynamic functions that determine operation modes for real thermal engines and at the same time study the trade-off between energy losses per cycle and the useful energy. As those objective functions, we focus our attention on a generalization of the so-called ecological function in terms of an epsilon parameter that depends on the particular heat transfer law used in the irreversible heat engine model. In this work, we mathematically describe the configuration space of an irreversible Curzon-Ahlborn type model. The above allows to determine the optimal relations between the model parameters so that a power plant operates in physically accessible regions, taking into account internal irreversibilities, introduced in two different ways (additively and multiplicatively). In addition, we establish the conditions that the e parameter must fulfill for the energy converter to work in an optimal region between maximum power output and maximum efficiency points.
- 1 July 2020
- Published by Walter de Gruyter GmbH in Journal of Non-Equilibrium Thermodynamics
- Vol. 45 (3) , 269-290
Energetic Optimization Considering a Generalization of the Ecological Criterion in Traditional Simple-Cycle and Combined-Cycle Power Plants
The fundamental issue in the energetic performance of power plants, working both as traditional fuel engines and as combined-cycle turbines (gas-steam), lies in quantifying the internal irreversibilities which are associated with the working substance operating in cycles. The purpose of several irreversible energy converter models is to find objective thermodynamic functions that determine operation modes for real thermal engines and at the same time study the trade-off between energy losses per cycle and the useful energy. As those objective functions, we focus our attention on a generalization of the so-called ecological function in terms of an epsilon parameter that depends on the particular heat transfer law used in the irreversible heat engine model. In this work, we mathematically describe the configuration space of an irreversible Curzon-Ahlborn type model. The above allows to determine the optimal relations between the model parameters so that a power plant operates in physically accessible regions, taking into account internal irreversibilities, introduced in two different ways (additively and multiplicatively). In addition, we establish the conditions that the e parameter must fulfill for the energy converter to work in an optimal region between maximum power output and maximum efficiency points.
- Open Access
The $PΦ$-Compromise Function as a criterion of merit to optimize irreversible thermal engines
Several authors have proposed out of equilibrium thermal engines models, allowing optimization processes involving a trade off between the power output of the engine and its dissipation. These operating regimes are achieved by using objective functions such as the ecological function ($EF$). In order to measure the quality of the balance between these characteristic functions, it was proposed a relationship where power output and dissipation are evaluated in the above mentioned $EF$-regime and they are compared with respect to its values at the regime of maximum power output. We called this relationship "Compromise Function" and only depends of a parameter that measures the quality of the compromise. Thereafter this function was used to select a value of the mentioned parameter to obtain the generalization of some different objective functions (generalizations of ecological function, omega function and efficient power), by demanding that these generalization parameters maximize the above mentioned functions. In this work we demonstrate that this function can be used directly as an objective function: the "$P{\Phi}$-Compromise Function" ($C_{P\Phi}$), also that the operation modes corresponding to the maximum Generalized Ecological Function, maximum Generalized Omega Function and maximum Efficient power output, are special cases of the operation mode of maximum $C_{P\Phi}$, having the same optimum high reduced temperature, then the characteristic functions will be the same in any of the above three working regimes, independent of the algebraic complexity of each generalized function. These results are presented for two different models of an irreversible energy converter: a non-endoreversible and a totally irreversible, both with heat leakage.Open AccessThe $PΦ$-Compromise Function as a criterion of merit to optimize irreversible thermal engines
Several authors have proposed out of equilibrium thermal engines models, allowing optimization processes involving a trade off between the power output of the engine and its dissipation. These operating regimes are achieved by using objective functions such as the ecological function ($EF$). In order to measure the quality of the balance between these characteristic functions, it was proposed a relationship where power output and dissipation are evaluated in the above mentioned $EF$-regime and they are compared with respect to its values at the regime of maximum power output. We called this relationship "Compromise Function" and only depends of a parameter that measures the quality of the compromise. Thereafter this function was used to select a value of the mentioned parameter to obtain the generalization of some different objective functions (generalizations of ecological function, omega function and efficient power), by demanding that these generalization parameters maximize the above mentioned functions. In this work we demonstrate that this function can be used directly as an objective function: the "$P{\Phi}$-Compromise Function" ($C_{P\Phi}$), also that the operation modes corresponding to the maximum Generalized Ecological Function, maximum Generalized Omega Function and maximum Efficient power output, are special cases of the operation mode of maximum $C_{P\Phi}$, having the same optimum high reduced temperature, then the characteristic functions will be the same in any of the above three working regimes, independent of the algebraic complexity of each generalized function. These results are presented for two different models of an irreversible energy converter: a non-endoreversible and a totally irreversible, both with heat leakage. - 22 July 2019
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 134 (7) , 1-13
Thermal optimization of Curzon-Ahlborn heat engines operating under some generalized efficient power regimes
- 22 July 2019
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 134 (7) , 1-13
Thermal optimization of Curzon-Ahlborn heat engines operating under some generalized efficient power regimes