Chaoyang Wang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chaoyang Wang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Junjie Yan
15 shared publicationsMing Liu
7 shared publications- Ming Liu
Xi’an Jiaotong University
7 shared publications Yongliang Zhao
7 shared publicationsZefeng Liu
4 shared publicationsJianlin Fan
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Elsevier in SSRN Electronic Journal
Effects of dry-out migration and flow maldistribution on thermomechanical stress and fatigue of water wall tubes during low-load ramp-up
During low load rapid ramp up of ultra-supercritical once-through boilers, dry-out heat transfer deterioration and flow maldistribution can cause pronounced thermomechanical stress concentration in water wall tubes, posing a potential threat to their structural integrity. This study investigates the effects of dry-out, flow maldistribution, and power ramp rate on the thermomechanical stress and low-cycle fatigue of water wall tubes in a 1100 MW ultra-supercritical coal-fired unit. Transient fluid pressure, mass flux, vapor quality, and heat transfer coefficient obtained from the thermal-hydraulic calculation are transferred to the wall temperature model and subsequently to a thermomechanical stress model and an ASME based fatigue assessment. The results show that dry-out induced heat transfer deterioration and subsequent heat transfer recovery cause asynchronous thermal responses between the inner and outer tube walls, resulting in a transient amplification of the radial temperature gradient and local stress concentration. Flow maldistribution shifts the dry-out region toward lower elevations with higher furnace heat flux, thereby increasing both thermomechanical stress and fatigue damage. At 30% THA, a 6% flow deviation increases the maximum equivalent stress to 136.6 MPa. During ramp-up from 30% to 50% THA, the maximum power ramp rates satisfying the 550 °C wall temperature criterion decrease from 2.0% Pe·min-1 under uniform flow to 1.5% and 1.0% Pe·min-1 under 3% and 6% flow deviations, respectively. At these respective operating limits, the fatigue life consumption rate increases from 2.83×10-5 to 2.96×10-5 and 3.97×10-5. These results indicate that satisfying the wall temperature criterion does not necessarily ensure an equivalent fatigue margin and demonstrate the importance of dry-out migration and flow maldistribution in the structural integrity assessment of water wall tubes.
- 1 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEffects of dry-out migration and flow maldistribution on thermomechanical stress and fatigue of water wall tubes during low-load ramp-up
During low load rapid ramp up of ultra-supercritical once-through boilers, dry-out heat transfer deterioration and flow maldistribution can cause pronounced thermomechanical stress concentration in water wall tubes, posing a potential threat to their structural integrity. This study investigates the effects of dry-out, flow maldistribution, and power ramp rate on the thermomechanical stress and low-cycle fatigue of water wall tubes in a 1100 MW ultra-supercritical coal-fired unit. Transient fluid pressure, mass flux, vapor quality, and heat transfer coefficient obtained from the thermal-hydraulic calculation are transferred to the wall temperature model and subsequently to a thermomechanical stress model and an ASME based fatigue assessment. The results show that dry-out induced heat transfer deterioration and subsequent heat transfer recovery cause asynchronous thermal responses between the inner and outer tube walls, resulting in a transient amplification of the radial temperature gradient and local stress concentration. Flow maldistribution shifts the dry-out region toward lower elevations with higher furnace heat flux, thereby increasing both thermomechanical stress and fatigue damage. At 30% THA, a 6% flow deviation increases the maximum equivalent stress to 136.6 MPa. During ramp-up from 30% to 50% THA, the maximum power ramp rates satisfying the 550 °C wall temperature criterion decrease from 2.0% Pe·min-1 under uniform flow to 1.5% and 1.0% Pe·min-1 under 3% and 6% flow deviations, respectively. At these respective operating limits, the fatigue life consumption rate increases from 2.83×10-5 to 2.96×10-5 and 3.97×10-5. These results indicate that satisfying the wall temperature criterion does not necessarily ensure an equivalent fatigue margin and demonstrate the importance of dry-out migration and flow maldistribution in the structural integrity assessment of water wall tubes.
- Open Access
- 28 August 2026
- Published by Elsevier in SSRN Electronic Journal
Coordinated control of water wall overheating and fatigue risk during rapid load cycling of ultra-supercritical coal-fired units considering dry-out heat transfer deterioration
Rapid load cycling of ultra-supercritical coal-fired units is essential for high renewable penetration, but it creates thermal and structural risks in water wall tubes, particularly under low load dry-out conditions. This study develops a coupled dynamic simulation and safety assessment framework for a 1100 MW ultra-supercritical once-through coal-fired unit, integrating water wall thermal hydraulic behavior, metal temperature evolution, plane strain thermomechanical stress calculation, and ASME based low-cycle fatigue assessment. The framework evaluates metal temperature, thermomechanical stress, and fatigue life consumption during the 30% to 50% THA ramp-up transient. Dry-out induced heat transfer deterioration strictly constrains the allowable power ramp rate. Under the original control strategy with uniform flow, peak wall temperatures at 39.0, 40.5, and 42.0 m reached 599.4, 578.9, and 564.6 °C at 3.0% Pe·min-1, exceeding the 550 °C limit for 15CrMoG. Reducing the ramping rate to 2.0% Pe·min-1 kept all monitored sections within the material limit. Flow maldistribution reduced the safety margin, lowering the permissible ramping rate to 1.5% Pe·min-1 and 1.0% Pe·min-1 for 3% and 6% flow deviation cases, respectively. An active feedwater control strategy triggered by dry-out zone wall temperature was proposed. Under uniform flow, staged feedwater compensation limited peak temperatures to below 550 °C at 3.0% Pe·min-1, reduced the maximum von Mises stress by 5.2%–6.3%, and decreased fatigue life consumption by 24.7%–26.8%. Under the 6% flow deviation case, overheated sections returned to a safe range, and fatigue life consumption decreased by approximately 17%–18%. These findings support safety constrained rapid load cycling and fatigue life management.
- 28 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCoordinated control of water wall overheating and fatigue risk during rapid load cycling of ultra-supercritical coal-fired units considering dry-out heat transfer deterioration
Rapid load cycling of ultra-supercritical coal-fired units is essential for high renewable penetration, but it creates thermal and structural risks in water wall tubes, particularly under low load dry-out conditions. This study develops a coupled dynamic simulation and safety assessment framework for a 1100 MW ultra-supercritical once-through coal-fired unit, integrating water wall thermal hydraulic behavior, metal temperature evolution, plane strain thermomechanical stress calculation, and ASME based low-cycle fatigue assessment. The framework evaluates metal temperature, thermomechanical stress, and fatigue life consumption during the 30% to 50% THA ramp-up transient. Dry-out induced heat transfer deterioration strictly constrains the allowable power ramp rate. Under the original control strategy with uniform flow, peak wall temperatures at 39.0, 40.5, and 42.0 m reached 599.4, 578.9, and 564.6 °C at 3.0% Pe·min-1, exceeding the 550 °C limit for 15CrMoG. Reducing the ramping rate to 2.0% Pe·min-1 kept all monitored sections within the material limit. Flow maldistribution reduced the safety margin, lowering the permissible ramping rate to 1.5% Pe·min-1 and 1.0% Pe·min-1 for 3% and 6% flow deviation cases, respectively. An active feedwater control strategy triggered by dry-out zone wall temperature was proposed. Under uniform flow, staged feedwater compensation limited peak temperatures to below 550 °C at 3.0% Pe·min-1, reduced the maximum von Mises stress by 5.2%–6.3%, and decreased fatigue life consumption by 24.7%–26.8%. Under the 6% flow deviation case, overheated sections returned to a safe range, and fatigue life consumption decreased by approximately 17%–18%. These findings support safety constrained rapid load cycling and fatigue life management.
- 29 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 245
Performance evaluation and operation optimization of a combined heat and power plant integrated with molten salt heat storage system
- 29 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 245
Performance evaluation and operation optimization of a combined heat and power plant integrated with molten salt heat storage system