Chih-Ju G. Jou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chih-Ju G. Jou has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Chien-Li Lee
Research and Development Center for Water Resource and Conservation, National Kaohsiung First Univ. of Science and Technology, Kaohsiung City 811, Taiwan
15 shared publicationsChen-Hua Wang
Dept. of Safety, Health and Environmental Engineering, National Kaohsiung First Univ. of Science and Technology, Kaohsiung City 811, Taiwan
3 shared publicationsHsien-Yi Lee
National Kaohsiung First University of Science & Technology
3 shared publicationsChien‐Li Lee
Department of Leisure and Recreation Management, Diwan University, Taiwan
2 shared publicationsChung‐Rung Wu
Department of Safety, Health and Environmental Engineering, National Kaohsiung First University of Science and Technology, Kaohsiung, Taiwan
2 shared publicationsH. Paul Wang
Department of Environmental Engineering, National Cheng Kung University, Taiwan
2 shared publications
Latest Publications
- Open Access
- 8 February 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (2) , 319-326
Utilization of the Tail Gas and Waste Catalyst from the Petrochemical Process to Generate Syngas by Microwave-induced Technology
- 8 February 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (2) , 319-326
Open AccessUtilization of the Tail Gas and Waste Catalyst from the Petrochemical Process to Generate Syngas by Microwave-induced Technology
- 1 October 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Hazardous, Toxic, and Radioactive Waste
- Vol. 22 (4)
Use of Gray Relational Analysis to Manage and Optimize Full-Scale Industrial Furnace Operation
In the context of waste gas energy recovery and management, the gray relational analysis method is applied to construct the optimum parameters and management of the operation conditions for a heating furnace used in the petrochemical industry. Comparing the results of tail gas recycling, the operational parameters are adjusted and the residual oxygen concentration in flue gases, preheated air temperature, and fuel oil temperature are studied for saving energy. The results show that the efficiency of the heating furnace is improved and the fuel consumption and carbon dioxide emissions are reduced. In addition, gray relational analysis is used to predict the parameters to optimize the operation and best energy saving demand. The results show that the optimal operating conditions are between 3.1% and 2.9% by volume, between 226°C and 232°C, and between 127°C and 129°C for residual oxygen concentration in flue gases, preheated air temperature, and fuel oil temperature, respectively. These values agree with the conditions actually used on-site for the optimum operation of heating furnaces. Therefore, gray relational analysis is the best way to evaluate and manage the operation parameters of a reheating furnace.
- 1 October 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Hazardous, Toxic, and Radioactive Waste
- Vol. 22 (4)
Use of Gray Relational Analysis to Manage and Optimize Full-Scale Industrial Furnace Operation
In the context of waste gas energy recovery and management, the gray relational analysis method is applied to construct the optimum parameters and management of the operation conditions for a heating furnace used in the petrochemical industry. Comparing the results of tail gas recycling, the operational parameters are adjusted and the residual oxygen concentration in flue gases, preheated air temperature, and fuel oil temperature are studied for saving energy. The results show that the efficiency of the heating furnace is improved and the fuel consumption and carbon dioxide emissions are reduced. In addition, gray relational analysis is used to predict the parameters to optimize the operation and best energy saving demand. The results show that the optimal operating conditions are between 3.1% and 2.9% by volume, between 226°C and 232°C, and between 127°C and 129°C for residual oxygen concentration in flue gases, preheated air temperature, and fuel oil temperature, respectively. These values agree with the conditions actually used on-site for the optimum operation of heating furnaces. Therefore, gray relational analysis is the best way to evaluate and manage the operation parameters of a reheating furnace.
- Open Access
- 18 August 2014
- Published by Canadian Center of Science and Education in Environment and Pollution
- Vol. 3 (4) , p41
Using Low Energy-Consuming Microwave Technology to Regenerate High Carbon-Containing Pt Catalyst
In this research, the high carbon-containing (coke, >20 wt%) Pt catalyst wasted from a full-scale petrochemical plant are regenerated in quartz and borax glass reactors by applying 250 W microwave irradiation for 18 hours. When irradiated with microwave substances of various dielectric characteristics will consume the microwave energy; the quantity of energy consumed is proportional to dielectric constant. Because borax glass has higher dielectric constant than quartz glass (e.g. 4.6 vs. 3.6 F/M), it causes higher energy loss than quartz glass. Laboratory results reveal that the removal of coke is smaller for the sample placed in the borax glass reactor than in the quartz glass container (17.7 vs. 25.9 %). On the other hand, higher MW output power leads to stronger electrical field to influence the mutual reactions between microwave and dielectric materials (e.g. the absorption of microwave energy), and the overall energy efficiency. The laboratory results also show that when the microwave energy is increased from 250 to 450 W, the carbon removal rate is raised from 25.9 to 38.1% with the sample placed in quartz glass reactor. Using the microwave energy to regenerate high carbon-containing (coke) Pt-catalyst as studied in this research is an innovated technology.
- 18 August 2014
- Published by Canadian Center of Science and Education in Environment and Pollution
- Vol. 3 (4) , p41
Open AccessUsing Low Energy-Consuming Microwave Technology to Regenerate High Carbon-Containing Pt Catalyst
In this research, the high carbon-containing (coke, >20 wt%) Pt catalyst wasted from a full-scale petrochemical plant are regenerated in quartz and borax glass reactors by applying 250 W microwave irradiation for 18 hours. When irradiated with microwave substances of various dielectric characteristics will consume the microwave energy; the quantity of energy consumed is proportional to dielectric constant. Because borax glass has higher dielectric constant than quartz glass (e.g. 4.6 vs. 3.6 F/M), it causes higher energy loss than quartz glass. Laboratory results reveal that the removal of coke is smaller for the sample placed in the borax glass reactor than in the quartz glass container (17.7 vs. 25.9 %). On the other hand, higher MW output power leads to stronger electrical field to influence the mutual reactions between microwave and dielectric materials (e.g. the absorption of microwave energy), and the overall energy efficiency. The laboratory results also show that when the microwave energy is increased from 250 to 450 W, the carbon removal rate is raised from 25.9 to 38.1% with the sample placed in quartz glass reactor. Using the microwave energy to regenerate high carbon-containing (coke) Pt-catalyst as studied in this research is an innovated technology.
- Open Access
- 17 June 2013
- Published by Canadian Center of Science and Education in Energy and Environment Research
- Vol. 3 (2) , p1
Enhancing Furnace Thermal Efficiency by Adjusting Fuel Temperature
Increasing fuel temperature leads to lower fuel density so that speed of the fuel leaving the nozzle increases causing the fuel to reach the burning point sooner. Hence, a higher temperature can be maintained in the furnace to reduce heat loss. Increasing the fuel temperature also causes higher temperature of the hot gas surrounding the burner nozzle, faster flowing velocity for the hot gas flow in the furnace, more even thermal distribution in the furnace, as well as faster thermal flow rising velocity and higher temperature in the furnace radiation zone. Hence, the fuel consumption and carbon dioxide emission are significantly reduced. In this study, results obtained with a full-scale furnace show that when the fuel temperature is raised from 95 o C to 130 o C, the hot gas temperature in the convective zone of the furnace rises by 21 o C; the furnace pressure increases by 2.5 mm H 2 O so that oxygen concentration in the excess air drops by 1.2 vol %. Under these conditions, 7.5 x 10 5 m 3 of fuel cost can be saved, and 858 ton per year of CO 2 emission can be reduced.
- 17 June 2013
- Published by Canadian Center of Science and Education in Energy and Environment Research
- Vol. 3 (2) , p1
Open AccessEnhancing Furnace Thermal Efficiency by Adjusting Fuel Temperature
Increasing fuel temperature leads to lower fuel density so that speed of the fuel leaving the nozzle increases causing the fuel to reach the burning point sooner. Hence, a higher temperature can be maintained in the furnace to reduce heat loss. Increasing the fuel temperature also causes higher temperature of the hot gas surrounding the burner nozzle, faster flowing velocity for the hot gas flow in the furnace, more even thermal distribution in the furnace, as well as faster thermal flow rising velocity and higher temperature in the furnace radiation zone. Hence, the fuel consumption and carbon dioxide emission are significantly reduced. In this study, results obtained with a full-scale furnace show that when the fuel temperature is raised from 95 o C to 130 o C, the hot gas temperature in the convective zone of the furnace rises by 21 o C; the furnace pressure increases by 2.5 mm H 2 O so that oxygen concentration in the excess air drops by 1.2 vol %. Under these conditions, 7.5 x 10 5 m 3 of fuel cost can be saved, and 858 ton per year of CO 2 emission can be reduced.
- 26 December 2012
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 38 (5) , 2504-2509
Improving furnace energy efficiency through adjustment of damper angle
- 26 December 2012
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 38 (5) , 2504-2509
Improving furnace energy efficiency through adjustment of damper angle
- Open Access
- 12 November 2012
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 62 (12) , 1443-1448
Microwave-induced nanoscale zero-valent iron degradation of perchloroethylene and pentachlorophenol.
Microwave (MW) is applied to enhance perchloroethylene (PCE) or pentachlorophenol (PCP) removal using zero-valent iron (ZVI; Fe0) as the dielectric medium. ZVI has a much higher dielectric loss factor (39.5) than other media; it is capable of absorbing MW radiation rapidly to speed up the release of electrons, leading to rises of the ZVI particle surface temperature. If the MW power is continued, excessive electricity will accumulated inside ZVI particles, resulting in sparks. The results show that during the initial 5 sec (700 W), the linear aliphatic PCE has a faster decomposing rate than the ringed PCP (82.0% vs. 4.8%) because less energy is required for decomposing the linear-chlorine bond (90 kcal mol−1) than ring-chlorine bonds (95 kcal mol−1). Later, the removal rate for either PCE or PCP remains the same when the exposure time is between 5 and 60 sec. Without MW irradiation, linear PCE molecules have larger surface area to contact ZVI, and hence they have better removal efficiencies than PCP molecules. Using Fe0 as a microwave dielectric medium to treat PCE or PCP is a new and worthwhile treatment technology; it is environmentally friendly, and its use will eliminate the secondary pollution.
- 12 November 2012
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 62 (12) , 1443-1448
Open AccessMicrowave-induced nanoscale zero-valent iron degradation of perchloroethylene and pentachlorophenol.
Microwave (MW) is applied to enhance perchloroethylene (PCE) or pentachlorophenol (PCP) removal using zero-valent iron (ZVI; Fe0) as the dielectric medium. ZVI has a much higher dielectric loss factor (39.5) than other media; it is capable of absorbing MW radiation rapidly to speed up the release of electrons, leading to rises of the ZVI particle surface temperature. If the MW power is continued, excessive electricity will accumulated inside ZVI particles, resulting in sparks. The results show that during the initial 5 sec (700 W), the linear aliphatic PCE has a faster decomposing rate than the ringed PCP (82.0% vs. 4.8%) because less energy is required for decomposing the linear-chlorine bond (90 kcal mol−1) than ring-chlorine bonds (95 kcal mol−1). Later, the removal rate for either PCE or PCP remains the same when the exposure time is between 5 and 60 sec. Without MW irradiation, linear PCE molecules have larger surface area to contact ZVI, and hence they have better removal efficiencies than PCP molecules. Using Fe0 as a microwave dielectric medium to treat PCE or PCP is a new and worthwhile treatment technology; it is environmentally friendly, and its use will eliminate the secondary pollution.
- Open Access
- 16 August 2012
- Published by Canadian Center of Science and Education in Environment and Pollution
- Vol. 2 (1) , p73
Microwave-induced Degradation of Chlorobenzene Using Fe0 and TiO2 Coated on Cordierites as Catalyst
In this research, MW is used to irradiate and induce Fe 0 /cordierite (Fe 0 coated cordierite particles) and TiO 2 /cordierite (TiO 2 coated cordierite particles) for improving the catalytic decomposition rate to remove chlorobenzene (CB) dissolved in aqueous solution. Laboratory results show that when 30 W of microwave energy is applied for 300 sec the irradiation of microwave than without microwave irradiation improves the CB removal efficiency by 3.2 times (57.4% vs. 18.2%) for Fe 0 /cordierite and 2.7 times (43.3% vs. 15.8%) for TiO 2 /cordierite. Hence, applying the microwave induced cordierite coated Fe 0 or TiO 2 particles is a new application that has been proved effective to remove chlorine-containing organic pollutants.
- 16 August 2012
- Published by Canadian Center of Science and Education in Environment and Pollution
- Vol. 2 (1) , p73
Open AccessMicrowave-induced Degradation of Chlorobenzene Using Fe0 and TiO2 Coated on Cordierites as Catalyst
In this research, MW is used to irradiate and induce Fe 0 /cordierite (Fe 0 coated cordierite particles) and TiO 2 /cordierite (TiO 2 coated cordierite particles) for improving the catalytic decomposition rate to remove chlorobenzene (CB) dissolved in aqueous solution. Laboratory results show that when 30 W of microwave energy is applied for 300 sec the irradiation of microwave than without microwave irradiation improves the CB removal efficiency by 3.2 times (57.4% vs. 18.2%) for Fe 0 /cordierite and 2.7 times (43.3% vs. 15.8%) for TiO 2 /cordierite. Hence, applying the microwave induced cordierite coated Fe 0 or TiO 2 particles is a new application that has been proved effective to remove chlorine-containing organic pollutants.
- 1 June 2012
- Published by SAGE Publications in Environmental Engineering Science
- Vol. 29 (6) , 432-435
Degradation of Chlorobenzene with Microwave-Aided Zerovalent Iron Particles
Microwave (MW) was applied to enhance chlorobenzene (CB) removal using commercial micron iron (μ-Fe) particles, nanoscale iron particles (nC-Fe0), and nanoscale iron particles freshly prepared in our laboratory (nP-Fe0) as the dielectric media. CB solution irradiated with 250 W MW for 150 s achieved better CB removal than without MW irradiation, because MW radiation increased the iron oxidization rate, surface activity, and hence, the CB removal rate. MW-induced iron particles were capable of removing 13.6 times (61.2% vs. 4.5% for μ-Fe), 2.8 times (76.5% vs. 27.5% for nP-Fe0), and 3.6 times (65.4% vs. 18.1% for nC-Fe0) more CB, and the CB activation energy decreased to 16.8 kJ/mol (μ-Fe), 3.3 kJ/mol (nP-Fe0), or 3.5 kJ/mol (nC-Fe0). MW-induced iron particles can potentially decompose toxic organic substances as demonstrated in this laboratory study.
- 1 June 2012
- Published by SAGE Publications in Environmental Engineering Science
- Vol. 29 (6) , 432-435
Degradation of Chlorobenzene with Microwave-Aided Zerovalent Iron Particles
Microwave (MW) was applied to enhance chlorobenzene (CB) removal using commercial micron iron (μ-Fe) particles, nanoscale iron particles (nC-Fe0), and nanoscale iron particles freshly prepared in our laboratory (nP-Fe0) as the dielectric media. CB solution irradiated with 250 W MW for 150 s achieved better CB removal than without MW irradiation, because MW radiation increased the iron oxidization rate, surface activity, and hence, the CB removal rate. MW-induced iron particles were capable of removing 13.6 times (61.2% vs. 4.5% for μ-Fe), 2.8 times (76.5% vs. 27.5% for nP-Fe0), and 3.6 times (65.4% vs. 18.1% for nC-Fe0) more CB, and the CB activation energy decreased to 16.8 kJ/mol (μ-Fe), 3.3 kJ/mol (nP-Fe0), or 3.5 kJ/mol (nC-Fe0). MW-induced iron particles can potentially decompose toxic organic substances as demonstrated in this laboratory study.
- 31 December 2011
- Published by Elsevier in Fuel Processing Technology
- Vol. 92 (12) , 2335-2340
Saving fuel consumption and reducing pollution emissions for industrial furnace
- 31 December 2011
- Published by Elsevier in Fuel Processing Technology
- Vol. 92 (12) , 2335-2340
Saving fuel consumption and reducing pollution emissions for industrial furnace
- 25 April 2011
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 31 (1) , 157-162
Improving furnace and boiler cost‐effectiveness and CO2 emission by adjusting excess air
Reducing the input excess air or airflow rate to a furnace or boiler will result in decreasing transmission rate of the thermal flow from the radiation zone to the convection heating surface zone in the furnace. Results of the plant‐scale test presented in this article show that if the furnace is operated at 3.6 × 107 kcal/h of combustion capacity, decreasing the residual O2 concentration in the furnace flue gas from 4% to 2.5% will save 9.3 × 103 m3 of natural gas consumption, and 2.1 × 104 tons of CO2 emission annually. For the boiler tested in the study, 1.8 × 105 m3 of natural gas consumption and 3.9 × 105 tons of CO2 emission will be reduced annually if it is operated with 90 ton/h steam yield. Hence, controlling the input excess air (or oxygen) as an important operating alternative to enhance thermal efficiency, and alleviate environmental impact of a heater furnace and boiler has been confirmed in this research. © 2011 American Institute of Chemical Engineers Environ Prog, 2012
- 25 April 2011
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 31 (1) , 157-162
Improving furnace and boiler cost‐effectiveness and CO2 emission by adjusting excess air
Reducing the input excess air or airflow rate to a furnace or boiler will result in decreasing transmission rate of the thermal flow from the radiation zone to the convection heating surface zone in the furnace. Results of the plant‐scale test presented in this article show that if the furnace is operated at 3.6 × 107 kcal/h of combustion capacity, decreasing the residual O2 concentration in the furnace flue gas from 4% to 2.5% will save 9.3 × 103 m3 of natural gas consumption, and 2.1 × 104 tons of CO2 emission annually. For the boiler tested in the study, 1.8 × 105 m3 of natural gas consumption and 3.9 × 105 tons of CO2 emission will be reduced annually if it is operated with 90 ton/h steam yield. Hence, controlling the input excess air (or oxygen) as an important operating alternative to enhance thermal efficiency, and alleviate environmental impact of a heater furnace and boiler has been confirmed in this research. © 2011 American Institute of Chemical Engineers Environ Prog, 2012