ECElżbieta Czekajska-Chehab

Elżbieta Czekajska-Chehab

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Elżbieta Czekajska-Chehab has a total of 245 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Identification of Thermobifida fusca as a main causative agent of mushroom compost worker’s lung – case series

    by Barbara Mackiewicz, Angelina Wójcik-Fatla, Jacek Dutkiewicz, Jan Siwiec, Tomasz Kucharczyk, Elżbieta Czekajska-Chebab, Mariola Paściak, Bogumiła Szponar, Grażyna Cholewa, Janusz Milanowski

    Mushroom compost worker's lung (MCWL) is a hypersensitivity pneumonitis (HP) entity occurring in workers employed at preparing compost for the cultivation of white button mushrooms. The aim of the study is to identify the strains of thermophilic actinobacteria as the potential causative agents of MCWL symptoms in workers. Clinical examinations included chest X-ray, high-resolution computed tomography (HRCT), bronchoscopy with bronchoalveolar lavage (BAL), pulmonary function tests comprising spirometric measurements, DLCO measurements, body pletysmography, and arterial - blood gas tests. Identification of thermophilic actinobacteria was performed by microscopy, culture and genetic methods. Allergological tests included the agar gel precipitation test and inhalation challenge with actinomycetal antigens. Among a group of 20 patients, 15 showed in HRCT ground-glass attenuations solely and were diagnosed with acute HP, 3 showed ground-glass attenuations with pulmonary fibrosis and were diagnosed with subacute HP, while 2 patients were diagnosed with Organic Dust Toxic Syndrome (ODTS). Thermobifida fusca and Laceyella sacchari strains were isolated from the symptom-causing mushroom compost. In 3 workers, strong precipitin reactions to Th. fusca were found, whereas there were no reactions to L. sacchari. Four workers showed a positive inhalation response to small doses of Th. fusca antigen. The results of this study indicate that Th. fusca is most probably a major causative agent of MCWL and should be considered in the diagnosis of HP in workers of the mushroom compost facility.


  • Open Access

    Rare Coexistence of a Single Coronary Artery, Myocardial Bridging, and Bicuspid Aortic Valve Detected by Coronary Computed Tomography Angiography During Preoperative Assessment: A Case Report and Literature Review

    by Piotr Machowiec, Piotr Przybylski, Elżbieta Czekajska-Chehab

    Background and Clinical Significance: Bicuspid aortic valve (BAV) is the most common congenital heart defect and may coexist with other cardiovascular anomalies. Among these is a single coronary artery (SCA), a rare congenital condition in which the entire coronary circulation originates from a single coronary ostium. Cardiac computed tomography (CCT) enables simultaneous evaluation of coronary artery anatomy and aortic valve morphology with high spatial resolution, which may influence procedural strategy in patients undergoing valve interventions. Case Presentation: This report represents the first documented case of a 59-year-old male with mixed aortic valve disease in whom preoperative CCT revealed the coexistence of BAV, SCA (Lipton type L-I), and myocardial bridging (MB) involving the mid segment of the left anterior descending artery (LAD). Identification of these findings was crucial for preoperative assessment and contributed to the selection of an appropriate surgical strategy. Conclusions: CCT plays a key role in the preoperative evaluation of valvular heart disease, including in patients with coexisting BAV and SCA. It enables individualized procedural planning and minimizes the risk of perioperative complications.

  • Open Access

    Assessment of Potential Predictors of Aortic Stenosis Severity Using ECG-Gated Multidetector CT in Patients with Bicuspid and Tricuspid Aortic Valves Prior to TAVI

    by Piotr Machowiec, Piotr Przybylski, Elżbieta Czekajska-Chehab

    Background/Objectives: The aim of this study was to evaluate the usefulness of selected predictive parameters obtainable from cardiac multidetector computed tomography for assessing the severity of aortic valve stenosis in patients scheduled for transcatheter aortic valve implantation (TAVI). Methods: A detailed retrospective analysis was performed on 105 patients with a bicuspid aortic valve (BAV), selected from a cohort of 1000 patients with BAV confirmed on ECG-gated CT, and on 105 patients with a tricuspid aortic valve (TAV) matched for sex and age. All patients included in both groups had significant aortic stenosis confirmed on transthoracic echocardiography. Results: Across the entire cohort, a trend toward higher aortic valve calcium scores was observed in patients with bicuspid compared to tricuspid aortic valves (4194.8 ± 2748.7 vs. 3335.0 ± 1618.8), although this difference did not reach statistical significance (p = 0.080). However, sex-stratified analysis showed higher calcium scores in males with BAV than with TAV (5596.8 ± 2936.6 vs. 4061.4 ± 1659.8, p = 0.002), with no significant difference observed among females (p > 0.05). Univariate regression analysis showed that the aortic valve calcium score was the strongest statistically significant predictor of aortic stenosis severity in both groups, with R2 = 0.224 for BAV and R2 = 0.479 for TAV. In the multiple regression model without interaction terms, the explanatory power increased to R2 = 0.280 for BAV and R2 = 0.495 for TAV. Conclusions: In patients scheduled for TAVI, linear regression models assess the severity of aortic stenosis more accurately than any individual predictive parameter obtainable from ECG-CT, with the aortic valve Agatston score emerging as the most reliable single CT-derived predictor of stenosis severity in both TAV and BAV subgroups.

  • Open Access

    Novel case of coronary artery ectasia and myocardial bridging in one segment detected by coronary computed tomography angiography

    by Gabriel Czepe, Piotr Przybylski, Elżbieta Czekajska-Chehab

    Coronary artery ectasia (CAE) is defined as a dilation exceeding 1.5 times the diameter of an adjacent normal artery, predominantly affecting males. Myocardial bridging (MB) is a condition in which the coronary artery runs intramurally within myocardial tissue. Coronary computed tomography angiography (CCTA) offers high-resolution imaging, facilitating accurate diagnosis of these conditions. This report presents the first documented case of a 78-year-old female with CAE and superficial MB coexisting in the same segment of the left anterior descending artery that was detected incidentally by CCTA.


  • Open Access

    Patients with a Bicuspid Aortic Valve (BAV) Diagnosed with ECG-Gated Cardiac Multislice Computed Tomography—Analysis of the Reasons for Referral, Classification of Morphological Phenotypes, Co-Occurring Cardiovascular Abnormalities, and Coronary Artery Stenosis

    by Piotr Machowiec, Piotr Przybylski, Elżbieta Czekajska-Chehab, Andrzej Drop

    Background/Objectives: The aim of this study was to analyze a group of patients with a bicuspid aortic valve (BAV) examined with ECG-gated cardiac CT (ECG-CT), focusing on the assessment of the clinical reasons for cardiac CT, cardiovascular abnormalities coexisting with their BAV, and coronary artery stenosis. Methods: A detailed statistical analysis was conducted on 700 patients with a BAV from a group of 15,670 patients examined with ECG-CT. Results: The incidence of a BAV in ECG-CT was 4.6%. The most common reason for examination was suspicion of coronary heart disease—31.1%. Cardiovascular defects most frequently associated with a BAV were a VSD (4.3%) and coarctation of the aorta (3.6%), while among coronary anomalies, they were high-take-off coronary arteries (6.4%) and paracommissural orifice of coronary arteries (4.4%). The analysis of the coronary artery calcium index showed significantly lower values for type 2 BAV compared to other valve types (p < 0.001), with the lowest average age in this group of patients. Moreover, the presence of a raphe between the coronary and non-coronary cusps was associated with a higher rate of significant coronary stenosis compared to other types of BAVs (p < 0.001). Conclusions: The most common reason for referral for cardiac ECG-CT in the group ≤ 40-year-olds with a BAV was the suspicion of congenital cardiovascular defects, while in the group of over 40-year-olds, it was the suspicion of coronary artery disease. The incidence of cardiovascular abnormalities co-occurring with BAV and diagnosed with ECG-CT differs among specific patient subgroups. The presence of a raphe between the coronary and non-coronary cusps appears to be a potential risk factor for significant coronary stenosis in patients with BAVs.


  • Open Access

    Angle Dependence of Electrode Lead-Related Artifacts in Single- and Dual-Energy Cardiac ECG-Gated CT Scanning—A Phantom Study

    by Piotr Tarkowski, Elżbieta Siek, Grzegorz Staśkiewicz, Dennis K. Bielecki, Elżbieta Czekajska-Chehab

    Background: The electrodes of implantable cardiac devices (ICDs) may cause significant problems in cardiac computed tomography (CT) because they are a source of artifacts that obscure surrounding structures and possible pathology. There are a few million patients currently with ICDs, and some of these patients will require cardiac imaging due to coronary artery disease or problems with ICDs. Modern CT scanners can reduce some of the metal artifacts because of MAR software, but in some vendors, it does not work with ECG gating. Introduced in 2008, dual-energy CT scanners can generate virtual monoenergetic images (VMIs), which are much less susceptible to metal artifacts than standard CT images. Objective: This study aimed to evaluate if dual-energy CT can reduce metal artifacts caused by ICD leads by using VMIs. The second objective was to determine how the angle between the electrode and the plane of imaging affects the severity of the artifacts in three planes of imaging. Methods: A 3D-printed model was constructed to obtain a 0–90-degree field at 5-degree intervals between the electrode and each of the planes: axial, coronal, and sagittal. This electrode was scanned in dual-energy and single-energy protocols. VMIs with an energy of 40–140 keV with 10 keV intervals were reconstructed. The length of the two most extended artifacts originating from the tip of the electrode and 2 cm above it—at the point where the thick metallic defibrillating portion of the electrode begins—was measured. Results: For the sagittal plane, these observations were similar for both points of the ICDs that were used as the reference location. VMIs with an energy over 80 keV produce images with fewer artifacts than similar images obtained in the single-energy scanning mode. Conclusions: Virtual monoenergetic imaging techniques may reduce streak artifacts arising from ICD electrodes and improve the quality of the image. Increasing the angle of the electrode as well as the imaging plane can reduce artifacts. The angle between the electrode and the beam of X-rays can be increased by tilting the gantry of the scanner or lifting the upper body of the patient.


  • Open Access

    Outcomes of Open Repair Treatment for Acute Versus Chronic Achilles Tendon Ruptures: Long-Term Retrospective Follow-Up of a Minimum 10 Years—A Pilot Study

    by Marta Tarczyńska, Mateusz Szubstarski, Krzysztof Gawęda, Piotr Przybylski, Elżbieta Czekajska-Chehab

    The aim of the present study was to compare repaired Achilles tendon (AT) remodelling, whether its function was restored and what effects the surgery had on our patients’ gait cycle in a long-term follow-up study. The study population comprised 30 human subjects treated acutely and chronically for AT ruptures, using the same surgical technique in all cases. The study group was divided into two subgroups regarding the age of their AT injury, i.e., how much time elapsed between the injury and when a correct diagnosis was made and when adequate treatment was applied. Following these criteria, persons presenting at less than 4 weeks postinjury were classified as acute rupture (AR) patients and those presenting at more than 4 weeks after injury were grouped as chronic rupture (CR) patients. Both patient groups were operated on using a surgical method favoured at least a decade ago, i.e., open repair through a posteromedial approach. The AT was augmented with a plantaris longus tendon autograft, followed by suturing using the pull-out suture technique. The results were measured using clinical, ultrasonographic (US) and pedobarographic methods. Our ultrasonographic and pedobarographic findings revealed differences between both patient groups, thus indicating that delayed surgery had negative impacts on treatment success, however, with good long-term functional score outcomes in both patient groups. Nevertheless, delayed treatment of AT ruptures did not leave individual gait phases unaffected, as it also affected the plantar surface and balance performance of the affected limb. As per the results, the Achilles tendon manifested decreased capacity following delayed treatment; however, its long-term functional outcomes were favourable, irrespective of whether it was for acute or chronic patients.


  • Open Access

    Atrial fibrillation ablation: the position of computed tomography in pre-procedural imaging

    by Milena Stachyra, Andrzej Glowniak, Elzbieta Czekajska-Chehab

    Atrial fibrillation (AF) is the most common supraventricular arrhythmia. Despite significant advances in its treatment, it still remains one of the leading causes of cardiovascular morbidity and mortality. In the last two decades, pulmonary vein isolation (PVI) was developed as the most effective treatment option. The reported effectiveness of a single ablation procedure ranges from 40% to 69% with single, and up to 88% with repeated procedures, with acceptable safety profile. The PubMed database was searched, using terms including ‘atrial fibrillation ablation’, ‘pulmonary vein isolation’, ‘computed tomography’, ‘pulmonary vein anatomy’ and ‘ovality index’. Papers were reviewed for relevance and scientific merit. Different imaging techniques are used for pre-procedural assessment of left atrial (LA) anatomy, of which computed tomography (CT) is the most common. It allows assessing pulmonary vein (PV) anatomy, the LA wall thickness in different regions and the left atrial appendage (LAA) anatomy, together with excluding the presence of intracardiac thrombi. Pre-procedural PVs imaging is important regardless of the selected ablation technique, however, cryoballoon (CB) ablation seems to be particularly anatomy-dependent. Additionally, CT also permits assessment of several PVs characteristics (geometry, dimensions, angulations, the ostium area, orientation and ovality index (OI), which are essential for the patients’ qualification and designing the strategy of AF ablation. In this paper, we have reviewed the role of CT imaging in patients undergoing ablation procedure due to recurrent/symptomatic atrial fibrillation. Moreover, we discussed the relevant literature.


  • Open Access

    Dual-Energy Heart CT: Beyond Better Angiography—Review

    by Piotr Tarkowski, Elżbieta Czekajska-Chehab

    Heart CT has undergone substantial development from the use of calcium scores performed on electron beam CT to modern 256+-row CT scanners. The latest big step in its evolution was the invention of dual-energy scanners with much greater capabilities than just performing better ECG-gated angio-CT. In this review, we present the unique features of dual-energy CT in heart diagnostics.


  • Open Access

    Atypical Cardiac Location of Melanoma of Unknown Origin

    by Agnieszka Styczeń, Mariusz Kozak, Marta Karaś-Głodek, Elżbieta Czekajska-Chehab, Andrzej Tomaszewski, Andrzej Wysokiński, Tomasz Zapolski

    The subject was a 66-year-old woman, suffering from the chest pain evoked by physical activity. Transthoracic echocardiography (TTE) revealed an abnormal structure, 41 × 29 mm. In MSCT, a hypodensic mobile tissue lesion that was infiltrating the whole thickness of left ventricle was confirmed. PET excluded the existence of other remote lesions. After surgical tumor removal, histopathological differential diagnosis revealed melanoma, myoepithelial cancer, and MPNST “high–grade” sarcoma. A control TTE detected a tumor that was 14 × 10 mm. After immunohistochemical results, immunotherapy with pembrolizumab was used, which resulted in complete tumor resolution. Presently, surgical resection and neoadjuvant targeted immunochemotherapy remain the treatment of choice for clinical stage III/IV melanoma.