Chetan Poudel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chetan Poudel has a total of 213 co-authors. Here are the top co-authors by number of shared publications:
- Clemens Friedrich Kaminski
Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK
10 shared publications - Gabriele Kaminski Schierle
Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK
7 shared publications - Joshua C. Vaughan
Department of Chemistry, University of Washington, Seattle, WA 98195
5 shared publications - Ioanna Mela
Department of Pharmacology University of Cambridge Cambridge UK
4 shared publications Matthew J. Merrins
Madison, WI, Cambridge, United Kingdom
4 shared publications- Clara Lopes Novo
Epigenetics Programme, The Babraham Institute, Cambridge, UK
3 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by Springer Nature in Nature Communications
A microfluidic fluorescence lifetime screening platform bridges in vitro and in vivo formats and enables discovery of Amyloid β aggregation inhibitors
Inhibiting the aggregation of Amyloid β (1-42) is a promising strategy for the development of disease-modifying Alzheimer’s disease therapeutics. To date, however, no sufficiently efficacious inhibitors have been identified, despite the best efforts of more than 200 advanced drug development campaigns. This failure can be partially attributed to limitations in current in vitro compound screening and in vivo validation assays. Here, we report a high throughput assay platform based on the use of a fluorescence lifetime aggregation sensor that can be applied in vitro and in vivo. This microfluidic “nanoFLIM” assay presents a cost-effective and reliable alternative to conventional early-stage small molecule discovery platforms for cell-free Amyloid β aggregation. The fluorescence lifetime sensor can dynamically monitor peptide aggregation in cellular and Caenorhabditis elegans disease models, providing directly comparable aggregation kinetics, which is not achievable by any other method. The power of this unified platform for accelerating hit-to-lead strategies, lowering attrition rates and expediting in vivo screening, was demonstrated with a pilot screening campaign of 445 compounds, revealing an inhibitor that can inhibit Amyloid β self-assembly both in vitro as well as in cellular and whole organism disease models.
- 13 November 2026
- Published by Springer Nature in Nature Communications
Open AccessA microfluidic fluorescence lifetime screening platform bridges in vitro and in vivo formats and enables discovery of Amyloid β aggregation inhibitors
Inhibiting the aggregation of Amyloid β (1-42) is a promising strategy for the development of disease-modifying Alzheimer’s disease therapeutics. To date, however, no sufficiently efficacious inhibitors have been identified, despite the best efforts of more than 200 advanced drug development campaigns. This failure can be partially attributed to limitations in current in vitro compound screening and in vivo validation assays. Here, we report a high throughput assay platform based on the use of a fluorescence lifetime aggregation sensor that can be applied in vitro and in vivo. This microfluidic “nanoFLIM” assay presents a cost-effective and reliable alternative to conventional early-stage small molecule discovery platforms for cell-free Amyloid β aggregation. The fluorescence lifetime sensor can dynamically monitor peptide aggregation in cellular and Caenorhabditis elegans disease models, providing directly comparable aggregation kinetics, which is not achievable by any other method. The power of this unified platform for accelerating hit-to-lead strategies, lowering attrition rates and expediting in vivo screening, was demonstrated with a pilot screening campaign of 445 compounds, revealing an inhibitor that can inhibit Amyloid β self-assembly both in vitro as well as in cellular and whole organism disease models.
- 30 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 18 (869)
Hyperosmotic niche adaptation and tissue polyamines underlie MRSA persistence in the kidney
Methicillin-resistant Staphylococcus aureus (MRSA) bacteremia causes substantial morbidity, but tissue reservoirs that permit bacterial persistence remain poorly defined. Using intravenous USA300 MRSA infection in mice, multiplexed imaging, dual-species transcriptomics, host and bacterial genetics, and cell-based assays, we uncovered the renal inner medulla, the site of urine concentration, as an MRSA reservoir. In this hyperosmotic niche, MRSA evaded immune detection and co-opted tissue polyamines to sustain growth, enabling subsequent spread toward the renal cortex. Neutrophil recruitment to the inner medulla was profoundly delayed owing to osmotic inhibition of immune cell migration. Disruption of medullary osmolality with the loop diuretic furosemide accelerated neutrophil infiltration, limited bacterial spread, and improved renal outcomes. Mechanistically, polyamines promoted MRSA persistence through both extracellular and intracellular actions that depended on local osmolality and pH. In the medullary milieu, polyamines primarily associated with the bacterial surface and stabilized membranes against osmotic stress. Intracellular polyamines enhanced translation of guaB (inosine monophosphate dehydrogenase), the rate-limiting enzyme in bacterial de novo purine biosynthesis. The polyamine-catabolizing gene speG (spermidine acetyltransferase), uniquely present in epidemic USA300 MRSA strains, mitigated polyamine toxicity and conferred a selective advantage in the polyamine-rich kidney. These findings revealed the inner medulla as a physiologically immune-restricted MRSA reservoir and supported modulation of medullary osmolality and bacterial polyamine metabolism as candidate adjunctive strategies for limiting renal persistence and dissemination during MRSA bacteremia.
- 30 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 18 (869)
Hyperosmotic niche adaptation and tissue polyamines underlie MRSA persistence in the kidney
Methicillin-resistant Staphylococcus aureus (MRSA) bacteremia causes substantial morbidity, but tissue reservoirs that permit bacterial persistence remain poorly defined. Using intravenous USA300 MRSA infection in mice, multiplexed imaging, dual-species transcriptomics, host and bacterial genetics, and cell-based assays, we uncovered the renal inner medulla, the site of urine concentration, as an MRSA reservoir. In this hyperosmotic niche, MRSA evaded immune detection and co-opted tissue polyamines to sustain growth, enabling subsequent spread toward the renal cortex. Neutrophil recruitment to the inner medulla was profoundly delayed owing to osmotic inhibition of immune cell migration. Disruption of medullary osmolality with the loop diuretic furosemide accelerated neutrophil infiltration, limited bacterial spread, and improved renal outcomes. Mechanistically, polyamines promoted MRSA persistence through both extracellular and intracellular actions that depended on local osmolality and pH. In the medullary milieu, polyamines primarily associated with the bacterial surface and stabilized membranes against osmotic stress. Intracellular polyamines enhanced translation of guaB (inosine monophosphate dehydrogenase), the rate-limiting enzyme in bacterial de novo purine biosynthesis. The polyamine-catabolizing gene speG (spermidine acetyltransferase), uniquely present in epidemic USA300 MRSA strains, mitigated polyamine toxicity and conferred a selective advantage in the polyamine-rich kidney. These findings revealed the inner medulla as a physiologically immune-restricted MRSA reservoir and supported modulation of medullary osmolality and bacterial polyamine metabolism as candidate adjunctive strategies for limiting renal persistence and dissemination during MRSA bacteremia.
- 25 August 2026
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 39 (8) , 1537-1543
Stenosis of the glomerulotubular neck with chronic kidney disease
We have identified glomerulotubular neck stenoses as a novel feature of kidney histopathology that is associated with chronic kidney disease, independently of interstitial fibrosis and tubular atrophy. Herein we review the occurrence, morphology, and consequences of stenotic glomerulotubular necks, and propose future investigations.
- 25 August 2026
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 39 (8) , 1537-1543
Stenosis of the glomerulotubular neck with chronic kidney disease
We have identified glomerulotubular neck stenoses as a novel feature of kidney histopathology that is associated with chronic kidney disease, independently of interstitial fibrosis and tubular atrophy. Herein we review the occurrence, morphology, and consequences of stenotic glomerulotubular necks, and propose future investigations.
- Open Access
- 30 April 2026
- Published by Springer Nature in Research Square
High-throughput, organ-scale 3D tubule tracking using TubuleMAP
Advances in tissue clearing and lightsheet microscopy enable mesoscale imaging of intact and convoluted tubular networks, yet analytical tools to map tubule continuity and assess injury patterns within and across tubules are limited. Here, we introduce TubuleMAP, a semi-automated pipeline for 3D tubule tracking and reconstruction that adapts to various morphological and staining patterns, leverages parallel processing of terabyte-scale data for large-scale analysis of tubular networks, and uses a napari interface for human oversight. Using TubuleMAP, we reconstruct 1,000 intact mouse nephrons in ~1-millimeter-thick kidney slab with ~400-fold higher throughput and ≤1% human effort compared to prior approaches. These reconstructions enable analysis of mesoscale nephron organization, quantitative profiling of pathologic morphologies, whole-nephron cytometry, and identification of rare morphologies at unprecedented scales. We demonstrate generalizability by reconstructing all seminiferous tubules in a mouse testis within a day. TubuleMAP is released as an open-source Python package.
- 30 April 2026
- Published by Springer Nature in Research Square
Open AccessHigh-throughput, organ-scale 3D tubule tracking using TubuleMAP
Advances in tissue clearing and lightsheet microscopy enable mesoscale imaging of intact and convoluted tubular networks, yet analytical tools to map tubule continuity and assess injury patterns within and across tubules are limited. Here, we introduce TubuleMAP, a semi-automated pipeline for 3D tubule tracking and reconstruction that adapts to various morphological and staining patterns, leverages parallel processing of terabyte-scale data for large-scale analysis of tubular networks, and uses a napari interface for human oversight. Using TubuleMAP, we reconstruct 1,000 intact mouse nephrons in ~1-millimeter-thick kidney slab with ~400-fold higher throughput and ≤1% human effort compared to prior approaches. These reconstructions enable analysis of mesoscale nephron organization, quantitative profiling of pathologic morphologies, whole-nephron cytometry, and identification of rare morphologies at unprecedented scales. We demonstrate generalizability by reconstructing all seminiferous tubules in a mouse testis within a day. TubuleMAP is released as an open-source Python package.
- Open Access
High-throughput, organ-scale 3D tubule tracking using TubuleMAP
Advances in tissue clearing and lightsheet microscopy enable mesoscale imaging of intact and convoluted tubular networks, yet analytical tools to map tubule continuity and assess injury patterns within and across tubules are limited. Here, we introduce TubuleMAP, a semi-automated pipeline for 3D tubule tracking and reconstruction that adapts to various morphological and staining patterns, leverages parallel processing of terabyte-scale data for large-scale analysis of tubular networks, and uses a napari interface for human oversight. Using TubuleMAP, we reconstruct 1,000 intact mouse nephrons in ~1-millimeter-thick kidney slab with ~400-fold higher throughput and <1% human effort compared to prior approaches. These reconstructions enable analysis of mesoscale nephron organization, quantitative profiling of pathologic morphologies, whole-nephron cytometry, and identification of rare morphologies at unprecedented scales. We demonstrate generalizability by reconstructing all seminiferous tubules in a mouse testis within a day. TubuleMAP is released as an open-source Python package.
Open AccessHigh-throughput, organ-scale 3D tubule tracking using TubuleMAP
Advances in tissue clearing and lightsheet microscopy enable mesoscale imaging of intact and convoluted tubular networks, yet analytical tools to map tubule continuity and assess injury patterns within and across tubules are limited. Here, we introduce TubuleMAP, a semi-automated pipeline for 3D tubule tracking and reconstruction that adapts to various morphological and staining patterns, leverages parallel processing of terabyte-scale data for large-scale analysis of tubular networks, and uses a napari interface for human oversight. Using TubuleMAP, we reconstruct 1,000 intact mouse nephrons in ~1-millimeter-thick kidney slab with ~400-fold higher throughput and <1% human effort compared to prior approaches. These reconstructions enable analysis of mesoscale nephron organization, quantitative profiling of pathologic morphologies, whole-nephron cytometry, and identification of rare morphologies at unprecedented scales. We demonstrate generalizability by reconstructing all seminiferous tubules in a mouse testis within a day. TubuleMAP is released as an open-source Python package.
- Open Access
- 13 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (50) , eadk8829
Highly multiplexed fluorescence microscopy with spectrally tunable semiconducting polymer dots
Current studies of biological tissues require visualizing diverse cell types and molecular interactions, creating a growing need for versatile techniques to simultaneously probe numerous targets. Traditional multiplexed imaging is limited to around five targets at once. Emerging methods using sequential rounds of staining, imaging, and signal removal can probe tens of targets but require specialized hardware and time-consuming workflows and face challenges with sample distortion and artifacts. We present a highly multiplexed fluorescence microscopy method using semiconducting polymer dots (Pdots) in a single round of staining and imaging. Pdots are small, bright, and photostable fluorescent probes with a wide range of tunable Stokes shifts (20 to 450 nanometers). Multiple series of Pdots with varying excitation wavelengths allow for fast (<1 minute) and single-round imaging of up to 21 targets in the brain and kidney. This method is based on a simple immunofluorescence workflow, efficient use of spectral space, standard hardware, and straightforward analysis, making it widely applicable for bioimaging laboratories.
- 13 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (50) , eadk8829
Open AccessHighly multiplexed fluorescence microscopy with spectrally tunable semiconducting polymer dots
Current studies of biological tissues require visualizing diverse cell types and molecular interactions, creating a growing need for versatile techniques to simultaneously probe numerous targets. Traditional multiplexed imaging is limited to around five targets at once. Emerging methods using sequential rounds of staining, imaging, and signal removal can probe tens of targets but require specialized hardware and time-consuming workflows and face challenges with sample distortion and artifacts. We present a highly multiplexed fluorescence microscopy method using semiconducting polymer dots (Pdots) in a single round of staining and imaging. Pdots are small, bright, and photostable fluorescent probes with a wide range of tunable Stokes shifts (20 to 450 nanometers). Multiple series of Pdots with varying excitation wavelengths allow for fast (<1 minute) and single-round imaging of up to 21 targets in the brain and kidney. This method is based on a simple immunofluorescence workflow, efficient use of spectral space, standard hardware, and straightforward analysis, making it widely applicable for bioimaging laboratories.
- Open Access
Highly Multiplexed Fluorescence Microscopy with Spectrally Tunable Semiconducting Polymer Dots
Current studies of biological tissues require visualizing diverse cell types and molecular interactions, creating a growing need for versatile techniques to simultaneously probe numerous targets. Traditional multiplexed imaging is limited to around five targets at once. Emerging methods utilizing sequential rounds of staining, imaging, and signal removal can probe tens of targets but require specialized hardware, time-consuming workflows, and face some challenges with sample distortion and artifacts. Here we present a new method for highly-multiplexed fluorescence microscopy using semiconducting polymer dots (Pdots) in a single round of staining and imaging. Pdots are small, bright, and photostable fluorescent probes with a wide range of tunable Stokes shifts (20–450 nm). Multiple series of Pdots with varying excitation wavelengths allow for fast (<1 minute) and single-round imaging of up to 21 targets in brain and kidney. This method is based on a simple immunofluorescence workflow, efficient use of spectral space, standard hardware, and straightforward analysis, making it widely applicable for bioimaging laboratories.
Open AccessHighly Multiplexed Fluorescence Microscopy with Spectrally Tunable Semiconducting Polymer Dots
Current studies of biological tissues require visualizing diverse cell types and molecular interactions, creating a growing need for versatile techniques to simultaneously probe numerous targets. Traditional multiplexed imaging is limited to around five targets at once. Emerging methods utilizing sequential rounds of staining, imaging, and signal removal can probe tens of targets but require specialized hardware, time-consuming workflows, and face some challenges with sample distortion and artifacts. Here we present a new method for highly-multiplexed fluorescence microscopy using semiconducting polymer dots (Pdots) in a single round of staining and imaging. Pdots are small, bright, and photostable fluorescent probes with a wide range of tunable Stokes shifts (20–450 nm). Multiple series of Pdots with varying excitation wavelengths allow for fast (<1 minute) and single-round imaging of up to 21 targets in brain and kidney. This method is based on a simple immunofluorescence workflow, efficient use of spectral space, standard hardware, and straightforward analysis, making it widely applicable for bioimaging laboratories.
- Open Access
An end-to-end workflow for non-destructive 3D pathology
Recent advances in 3D pathology offer the ability to image orders-of-magnitude more tissue than conventional pathology while providing a volumetric context that is lacking with 2D tissue sections, all without requiring destructive tissue sectioning. Generating high-quality 3D pathology datasets on a consistent basis is non-trivial, requiring careful attention to many details regarding tissue preparation, imaging, and data/image processing in an iterative process. Here we provide an end-to-end protocol covering all aspects of a 3D pathology workflow (using light-sheet microscopy as an illustrative imaging platform) with sufficient detail to perform well-controlled preclinical and clinical studies. While 3D pathology is compatible with diverse staining protocols and computationally generated color palettes for visual analysis, this protocol will focus on a fluorescent analog of hematoxylin and eosin (H&E), which remains the most common stain for gold-standard diagnostic determinations. We present our guidelines for a broad range of end-users (e.g., biologists, clinical researchers, and engineers) in a simple tutorial format.
Open AccessAn end-to-end workflow for non-destructive 3D pathology
Recent advances in 3D pathology offer the ability to image orders-of-magnitude more tissue than conventional pathology while providing a volumetric context that is lacking with 2D tissue sections, all without requiring destructive tissue sectioning. Generating high-quality 3D pathology datasets on a consistent basis is non-trivial, requiring careful attention to many details regarding tissue preparation, imaging, and data/image processing in an iterative process. Here we provide an end-to-end protocol covering all aspects of a 3D pathology workflow (using light-sheet microscopy as an illustrative imaging platform) with sufficient detail to perform well-controlled preclinical and clinical studies. While 3D pathology is compatible with diverse staining protocols and computationally generated color palettes for visual analysis, this protocol will focus on a fluorescent analog of hematoxylin and eosin (H&E), which remains the most common stain for gold-standard diagnostic determinations. We present our guidelines for a broad range of end-users (e.g., biologists, clinical researchers, and engineers) in a simple tutorial format.
- Open Access
- 23 June 2022
- Published by Wiley in Journal of Microscopy
- Vol. 287 (3) , 138-147
A method for the fast and photon‐efficient analysis of time‐domain fluorescence lifetime image data over large dynamic ranges
Fluorescence lifetime imaging (FLIM) allows the quantification of sub‐cellular processes in situ, in living cells. A number of approaches have been developed to extract the lifetime from time‐domain FLIM data, but they are often limited in terms of speed, photon efficiency, precision or the dynamic range of lifetimes they can measure. Here, we focus on one of the best performing methods in the field, the centre‐of‐mass method (CMM), that conveys advantages in terms of speed and photon efficiency over others. In this paper, however, we identify a loss of photon efficiency of CMM for short lifetimes when background noise is present. We subsequently present a new development and generalization of CMM that provides for the rapid and accurate extraction of fluorescence lifetime over a large lifetime dynamic range. We provide software tools to simulate, validate and analyse FLIM data sets and compare the performance of our approach against the standard CMM and the commonly employed least‐square minimization (LSM) methods. Our method features a better photon efficiency than standard CMM and LSM and is robust in the presence of background noise. The algorithm is applicable to any time‐domain FLIM data set.
- 23 June 2022
- Published by Wiley in Journal of Microscopy
- Vol. 287 (3) , 138-147
Open AccessA method for the fast and photon‐efficient analysis of time‐domain fluorescence lifetime image data over large dynamic ranges
Fluorescence lifetime imaging (FLIM) allows the quantification of sub‐cellular processes in situ, in living cells. A number of approaches have been developed to extract the lifetime from time‐domain FLIM data, but they are often limited in terms of speed, photon efficiency, precision or the dynamic range of lifetimes they can measure. Here, we focus on one of the best performing methods in the field, the centre‐of‐mass method (CMM), that conveys advantages in terms of speed and photon efficiency over others. In this paper, however, we identify a loss of photon efficiency of CMM for short lifetimes when background noise is present. We subsequently present a new development and generalization of CMM that provides for the rapid and accurate extraction of fluorescence lifetime over a large lifetime dynamic range. We provide software tools to simulate, validate and analyse FLIM data sets and compare the performance of our approach against the standard CMM and the commonly employed least‐square minimization (LSM) methods. Our method features a better photon efficiency than standard CMM and LSM and is robust in the presence of background noise. The algorithm is applicable to any time‐domain FLIM data set.
- Open Access
- 20 June 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-16
Satellite repeat transcripts modulate heterochromatin condensates and safeguard chromosome stability in mouse embryonic stem cells
Heterochromatin maintains genome integrity and function, and is organised into distinct nuclear domains. Some of these domains are proposed to form by phase separation through the accumulation of HP1ɑ. Mouse heterochromatin contains noncoding major satellite repeats (MSR), which are highly transcribed in mouse embryonic stem cells (ESCs). Here, we report that MSR transcripts can drive the formation of HP1ɑ droplets in vitro, and modulate heterochromatin into dynamic condensates in ESCs, contributing to the formation of large nuclear domains that are characteristic of pluripotent cells. Depleting MSR transcripts causes heterochromatin to transition into a more compact and static state. Unexpectedly, changing heterochromatin’s biophysical properties has severe consequences for ESCs, including chromosome instability and mitotic defects. These findings uncover an essential role for MSR transcripts in modulating the organisation and properties of heterochromatin to preserve genome stability. They also provide insights into the processes that could regulate phase separation and the functional consequences of disrupting the properties of heterochromatin condensates.
- 20 June 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-16
Open AccessSatellite repeat transcripts modulate heterochromatin condensates and safeguard chromosome stability in mouse embryonic stem cells
Heterochromatin maintains genome integrity and function, and is organised into distinct nuclear domains. Some of these domains are proposed to form by phase separation through the accumulation of HP1ɑ. Mouse heterochromatin contains noncoding major satellite repeats (MSR), which are highly transcribed in mouse embryonic stem cells (ESCs). Here, we report that MSR transcripts can drive the formation of HP1ɑ droplets in vitro, and modulate heterochromatin into dynamic condensates in ESCs, contributing to the formation of large nuclear domains that are characteristic of pluripotent cells. Depleting MSR transcripts causes heterochromatin to transition into a more compact and static state. Unexpectedly, changing heterochromatin’s biophysical properties has severe consequences for ESCs, including chromosome instability and mitotic defects. These findings uncover an essential role for MSR transcripts in modulating the organisation and properties of heterochromatin to preserve genome stability. They also provide insights into the processes that could regulate phase separation and the functional consequences of disrupting the properties of heterochromatin condensates.