SLShi-Yu Li

Shi-Yu Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shi-Yu Li has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • Zhaoshen Li

    National Clinical Research Center for Digestive Diseases, Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China

    2 shared publications
  • Zhijie Wang

    Department of Gastroenterology, Affiliated Hangzhou First People's Hospital, School of Medicine, Westlake University, Hangzhou, Zhejiang, 310006, China

    2 shared publications
  • Chen Cui

    Department of Magnetic Resonance Imaging, Imaging Center, Fuwai Hospital,State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

    1 shared publication
  • Cheng Luo

    1 shared publication
  • Cheng‐Ye Pan

    Department of Gastroenterology, Changhai Hospital Naval Medical University Shanghai China

    1 shared publication
  • Chuanchao Xia

    Department of Gastroenterology, Changhai Hospital, Navy/Second Military Medical University, Shanghai, China

    1 shared publication

Latest Publications

  • Adverse events of 20–22G second‐generation endoscopic ultrasound‐guided fine‐needle biopsy needles for solid lesions in the upper gastrointestinal tract and adjacent organs: Systematic review and meta‐analysis

    by Cheng‐Ye Pan, Shi‐Min Wang, Dong‐Hao Cai, Jia‐Yi Ma, Shi‐Yu Li, Yibin Guo, Sun Jing, Jin Zhendong, Kaixuan Wang

    Objectives: Previous research has conducted meta‐analyses on the diagnostic accuracy of endoscopic ultrasound‐guided fine‐needle biopsy (EUS‐FNB). However, studies on adverse events (AEs) have been limited and sporadic and have included a highly diverse group of patients (with upper and lower gastrointestinal tract issues) and needles of varying sizes (19‐22‐25G). The purpose of this systematic review and meta‐analysis was to determine the incidence of AEs related to the utilization of 20–22G second‐generation EUS‐FNB needles subsequent to puncture of the upper gastrointestinal tract and adjacent organs.Methods: We searched the PubMed, Embase, and SCIE databases from January 1, 2010, to December 31, 2023. The primary outcome was percentage of summary AEs. Subgroup analyses were based on needle type, needle size, and lesion site.Results: A total of 99 studies were included in the analysis, with 9303 patients. The overall AE rate for 20–22G second generation EUS‐FNB needles in upper gastrointestinal EUS‐FNB was 1.8% (166/9303), with bleeding being the most common AE at 44.0%. The percentages of pancreatitis, abdominal pain, and other AEs were 24.1%, 21.1%, and 10.8%, respectively. Patients undergoing hepatic EUS‐FNB had the highest incidence of AEs at 14.0%, followed by submucosal lesions at 3.2% and pancreatic lesions at 2.6%.Conclusion: EUS‐FNB is a safe procedure with a relatively low risk of upper gastrointestinal AEs (1.8%) and no associated deaths. Postoperative bleeding and pancreatitis are the most common complications of EUS‐FNB. Most AEs are mild and self‐limiting in severity, and serious complications are very rare.


  • Sonography-based multimodal information platform for identifying the surgical pathology of ductal carcinoma in situ

    by Huaiyu Wu, Yitao Jiang, Hongtian Tian, Xiuqin Ye, Chen Cui, Siyuan Shi, Ming Chen, Zhimin Ding, Shiyu Li, Zhibin Huang, et al.


  • Open Access

    Clinicopathological Features of Sessile Serrated Polyps in China: A Retrospective Study of a Tertiary Hospital

    by Zhi-Jie Wang, Cheng Luo, Lin-Lin Zhao, Shi-Yu Li, Hong-Yu Fu, Xiao-Ju Su, Zhao-Shen Li

    Background: Serrated polyps have been recognized as the important premalignant lesions. In this study, we aimed to analyze the clinicopathological features of sessile serrated polyps and determine the association between sessile serrated polyps and synchronous advanced adenomas. Methods: Consecutive patients undergoing diagnostic or therapeutic colonoscopies (including 156 681 diagnostic colonoscopies) from 2011 to 2019 were included. Results: A total of 958 patients, including 699 (73%) males, were detected with at least 1 sessile serrated polyp, and 65.9% (n = 658) of sessile serrated polyps were located in the distal colon. Advanced serrated lesions accounted for 9.1% (n = 91) of all the sessile serrated polyp (n = 999). The types of SSP included flat type (953/999, 95.4%) and sub-pedunculated or pedunculated type (46/999, 4.6%). Meanwhile, there was no obvious evidence supporting the association between advanced adenomas and characteristics of advanced serrated lesions or sessile serrated polyps. Conclusion: Sessile serrated polyps seem to be more frequently seen in the distal colon of men in this study. However, more evidence is required to confirm the actual distribution of sessile serrated polyp in colon among Chinese people. There is still much room for improvement of sessile serrated polyp detection rate, and more importance should be attached to sessile serrated polyp both for pathologists and endoscopists. Cite this article as: Wang Z, Luo C, Zhao L, et al. Clinicopathological features of sessile serrated polyps in China: A retrospective study of a tertiary hospital. Turk J Gastroenterol. 2023;34(2):101-107.


  • Open Access

    Cryo-EM structures reveal the activation and substrate recognition mechanism of human enteropeptidase

    by Xiaoli Yang, Zhanyu Ding, Lisi Peng, Qiuyue Song, Deyu Zhang, Fang Cui, Chuanchao Xia, Keliang Li, Hua Yin, Shiyu Li, et al.

    Enteropeptidase (EP) initiates intestinal digestion by proteolytically processing trypsinogen, generating catalytically active trypsin. EP dysfunction causes a series of pancreatic diseases including acute necrotizing pancreatitis. However, the molecular mechanisms of EP activation and substrate recognition remain elusive, due to the lack of structural information on the EP heavy chain. Here, we report cryo-EM structures ofhumanEP in inactive, active, and substrate-bound states at resolutions from 2.7 to 4.9 Å. The EP heavy chain was observed to clamp the light chain with CUB2 domain for substrate recognition. The EP light chain N-terminus induced a rearrangement of surface-loops from inactive to active conformations, resulting in activated EP. The heavy chain then served as a hinge for light-chain conformational changes to recruit and subsequently cleave substrate. Our study provides structural insights into rearrangements of EP surface-loops and heavy chain dynamics in the EP catalytic cycle, advancing our understanding of EP-associated pancreatitis.


  • Endoscopic closure of large colonic perforations with a novel endoscopic clip device: An animal study (with videos)

    by Zhi‐Jie Wang, Shi‐Yu Li, Yan‐Hui Zhang, Yan Chen, Ping‐Ping Zhang, Zhao‐Shen Li, Yu Bai, Dong Wang

    Background and Aim: An endoscopic clip device was newly designed to accomplish the closure of large gastrointestinal defects. The aim of this study was to determine the feasibility and efficacy of this device in an ex vivo experimental setting.Methods: This prospective study was conducted in porcine colons (n = 5). A large (3–4 cm) linear full‐thickness incision was created using a scalpel externally. The device was used for endoscopic closure. The procedure time, number of clips, and success rate of closure were determined.Results: Ten defects were created in five porcine colons (two incisions in each specimen). Successful closure was achieved in all defects. The mean procedure time was 24.30 ± 4.42 min, the mean leak pressure is 28.30 ± 9.49 mmHg, and the mean number of additional conventional hemostatic clips used was 5.10 ± 0.99.Conclusions: The results indicated that this clip achieved the convenient and reliable closure of large defects in the colon wall in an ex vivo porcine model and seems to be a promising option for closing large gastrointestinal perforations.