Hiroki Kutsuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroki Kutsuma has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Junya Suzuki
Department of Physics, Faculty of Science, Kyoto University, Kyoto 606-8502, Japan
4 shared publications - Shugo Oguri
High Energy Accelerator Research Organization (KEK)
4 shared publications C. Otani
RIKEN Center for Advanced Photonics, Sendai
3 shared publications- Eunil Won
Korea University
3 shared publications - Michael William Peel
Imperial College London
3 shared publications O. Tajima
Kyoto Univ, Phys Dept, Kyoto 6068502, Japan
3 shared publications
Latest Publications
- Open Access
- 24 September 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 713, A295
Design methodology of hybrid-type microwave kinetic inductance detectors toward ground-based mm-submm observations
Context. Microwave kinetic inductance detectors (MKIDs) are superconducting detectors that have the potential to contribute to the construction of over 10 000 pixel cameras required for mm and submm astronomical observations over the next decade. One of the issues related to its application is two-level-system (TLS) noise that creates a 1/ f term in the power spectrum density (PSD) of the detectors. A hybrid-type MKID has been proposed for TLS noise suppression without affecting the MKID performance. In this paper, we present a systematic method to model a hybrid-type MKID for mitigating TLS noise while achieving high sensitivity. Aims. Previous studies have shown that TLS noise in MKIDs depends on the sampling frequency, internal power, device geometry, and temperature. The strength of the electrical field distribution along the resonator line also affects the TLS noise properties. Based on this knowledge, we constructed a noise model of a hybrid-type MKID. Methods. Using this model, we designed MKIDs for the cosmic microwave background radiation experiment, GroundBIRD. We evaluated the 1/ f noise properties and NET of the fabricated devices using the on-site measurements. Based on the NET measurements, we can confirm that the white noise of fabricated detectors is limited by atmospheric photon noise. From the 1/ f noise measurements, we also confirm that it is possible to reach an atmospheric photon noise limit down to a low sampling frequency (i.e., of a few Hz) at the typical observation conditions from Teide observatory. Results. We confirm the design methodology we propose for hybrid-type MKID works well in optimizing the TLS model to the hybrid-type MKID, as evidenced by performance verification measurements carried out in the laboratory and on site.
- 24 September 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 713, A295
Open AccessDesign methodology of hybrid-type microwave kinetic inductance detectors toward ground-based mm-submm observations
Context. Microwave kinetic inductance detectors (MKIDs) are superconducting detectors that have the potential to contribute to the construction of over 10 000 pixel cameras required for mm and submm astronomical observations over the next decade. One of the issues related to its application is two-level-system (TLS) noise that creates a 1/ f term in the power spectrum density (PSD) of the detectors. A hybrid-type MKID has been proposed for TLS noise suppression without affecting the MKID performance. In this paper, we present a systematic method to model a hybrid-type MKID for mitigating TLS noise while achieving high sensitivity. Aims. Previous studies have shown that TLS noise in MKIDs depends on the sampling frequency, internal power, device geometry, and temperature. The strength of the electrical field distribution along the resonator line also affects the TLS noise properties. Based on this knowledge, we constructed a noise model of a hybrid-type MKID. Methods. Using this model, we designed MKIDs for the cosmic microwave background radiation experiment, GroundBIRD. We evaluated the 1/ f noise properties and NET of the fabricated devices using the on-site measurements. Based on the NET measurements, we can confirm that the white noise of fabricated detectors is limited by atmospheric photon noise. From the 1/ f noise measurements, we also confirm that it is possible to reach an atmospheric photon noise limit down to a low sampling frequency (i.e., of a few Hz) at the typical observation conditions from Teide observatory. Results. We confirm the design methodology we propose for hybrid-type MKID works well in optimizing the TLS model to the hybrid-type MKID, as evidenced by performance verification measurements carried out in the laboratory and on site.
- 4 February 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (2)
Nb - Ti - N nanowire resonators and prospects for spin-photon coupling with electrons on solid neon
- 4 February 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (2)
Nb - Ti - N nanowire resonators and prospects for spin-photon coupling with electrons on solid neon
- 4 December 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (6)
Broadband kinetic inductance parametric amplifiers with impedance engineering
- 4 December 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (6)
Broadband kinetic inductance parametric amplifiers with impedance engineering
- 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Evaluation of NbTiN Superconducting Strip Photon Detectors With 0.1–30 µm Strip Widths
We report the niobium titanium nitride (NbTiN) superconducting strip photon detectors (SSPDs) with strip widths ranging from 0.1 to 30 µm. The bias current dependences of the detection efficiencies at the 1550 nm wavelength and the dark count rates were systematically evaluated in the wide range of the strip widths. Single-photon detection was confirmed and a saturation trend in the bias current dependence of detection efficiency was also observed for all strip width SSPDs. In addition, we measured the physical properties of the NbTiN films and found the switching current of SSPDs gradually deviated lower from the estimated depairing current with increasing the strip width. Furthermore, the dark counts occurred at the lower bias current relative to the depairing current as the strip width increased. These results suggest that the bias current is unevenly distributed as the strip width increases and the concentrated bias current may induce the dark counts. Our results would provide valuable insights into a better understanding of SSPDs with a wide range of strip widths, the origin of dark counts, and the mechanism of photon detection in superconducting strip.
- 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Evaluation of NbTiN Superconducting Strip Photon Detectors With 0.1–30 µm Strip Widths
We report the niobium titanium nitride (NbTiN) superconducting strip photon detectors (SSPDs) with strip widths ranging from 0.1 to 30 µm. The bias current dependences of the detection efficiencies at the 1550 nm wavelength and the dark count rates were systematically evaluated in the wide range of the strip widths. Single-photon detection was confirmed and a saturation trend in the bias current dependence of detection efficiency was also observed for all strip width SSPDs. In addition, we measured the physical properties of the NbTiN films and found the switching current of SSPDs gradually deviated lower from the estimated depairing current with increasing the strip width. Furthermore, the dark counts occurred at the lower bias current relative to the depairing current as the strip width increased. These results suggest that the bias current is unevenly distributed as the strip width increases and the concentrated bias current may induce the dark counts. Our results would provide valuable insights into a better understanding of SSPDs with a wide range of strip widths, the origin of dark counts, and the mechanism of photon detection in superconducting strip.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Loss Mechanisms of Epitaxial NbN Coplanar Waveguide Resonators on an MgO Substrate
We investigated the loss mechanisms of superconducting circuits with epitaxially grown NbN(100) on MgO(100) substrates by measuring quarter-wave coplanar waveguide resonators with various strip and slot widths. The power dependence of the internal quality factor and the temperature dependence of the resonance frequency shift were evaluated in a dilution refrigerator. The measurement and analysis of the loss in these resonators indicate that the loss was dominated by a two-level system (TLS) loss and the TLS host materials were primarily distributed at the surface of the substrate.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Loss Mechanisms of Epitaxial NbN Coplanar Waveguide Resonators on an MgO Substrate
We investigated the loss mechanisms of superconducting circuits with epitaxially grown NbN(100) on MgO(100) substrates by measuring quarter-wave coplanar waveguide resonators with various strip and slot widths. The power dependence of the internal quality factor and the temperature dependence of the resonance frequency shift were evaluated in a dilution refrigerator. The measurement and analysis of the loss in these resonators indicate that the loss was dominated by a two-level system (TLS) loss and the TLS host materials were primarily distributed at the surface of the substrate.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (7) , 1-8
Self-Shunted Superconducting Flux Qubit
We proposed and theoretically investigated the selfshunted superconducting flux qubits (SSFQs) with relatively large Josephson junctions with the diameter over 1 μm. Owing to the large self capacitance of several 10 fF in the junctions, the large shunt capacitor with dimensions of several 100 μm of the conventional capacitively-shunted (C-shunt) flux qubits can be eliminated, resulting in significant reduction of the footprint. We systematically calculated the SSFQ performances such as the anharmonicity and investigated their dependences on the circuit parameters. As a result, it was shown that the SSFQs have the large anharmonicity of 400−2000 MHz for the reasonable parameters such as the large junction area of around 1 μm2 and the small critical current density of around 10 A/cm2. Furthermore, we derived and estimated the relative relaxation time of the SSFQs due to the charge and flux noises. As a result, we found that the high anharmonicity over 800 MHz could be achieved without degrading the relaxation time from that of the high-coherence flux qubits. The SSFQs offer the new choice of the highly-scalable qubits, which achieve both the small footprint and high anharmonicity.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (7) , 1-8
Self-Shunted Superconducting Flux Qubit
We proposed and theoretically investigated the selfshunted superconducting flux qubits (SSFQs) with relatively large Josephson junctions with the diameter over 1 μm. Owing to the large self capacitance of several 10 fF in the junctions, the large shunt capacitor with dimensions of several 100 μm of the conventional capacitively-shunted (C-shunt) flux qubits can be eliminated, resulting in significant reduction of the footprint. We systematically calculated the SSFQ performances such as the anharmonicity and investigated their dependences on the circuit parameters. As a result, it was shown that the SSFQs have the large anharmonicity of 400−2000 MHz for the reasonable parameters such as the large junction area of around 1 μm2 and the small critical current density of around 10 A/cm2. Furthermore, we derived and estimated the relative relaxation time of the SSFQs due to the charge and flux noises. As a result, we found that the high anharmonicity over 800 MHz could be achieved without degrading the relaxation time from that of the high-coherence flux qubits. The SSFQs offer the new choice of the highly-scalable qubits, which achieve both the small footprint and high anharmonicity.
- Open Access
- 22 January 2024
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2024 (2)
Pointing Calibration of GroundBIRD Telescope Using Moon Observation Data
Understanding telescope pointing (i.e. line of sight) is important for observing the cosmic microwave background (CMB) and astronomical objects. The Moon is a candidate astronomical source for pointing calibration. Although the visible size of the Moon (30′) is larger than that of the planets, we can frequently observe the Moon once a month with a high signal-to-noise ratio. We developed a method for performing pointing calibration using observational data from the Moon. We considered the tilts of the telescope axes as well as the encoder and collimation offsets for pointing calibration. In addition, we evaluated the effects of the nonuniformity of the brightness temperature of the Moon, which is a dominant systematic error. As a result, we successfully achieved a pointing accuracy of 3.3′. This is one order of magnitude smaller than an angular resolution of 36′. This level of accuracy competes with past achievements in other ground-based CMB experiments using observational data from the planets.
- 22 January 2024
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2024 (2)
Open AccessPointing Calibration of GroundBIRD Telescope Using Moon Observation Data
Understanding telescope pointing (i.e. line of sight) is important for observing the cosmic microwave background (CMB) and astronomical objects. The Moon is a candidate astronomical source for pointing calibration. Although the visible size of the Moon (30′) is larger than that of the planets, we can frequently observe the Moon once a month with a high signal-to-noise ratio. We developed a method for performing pointing calibration using observational data from the Moon. We considered the tilts of the telescope axes as well as the encoder and collimation offsets for pointing calibration. In addition, we evaluated the effects of the nonuniformity of the brightness temperature of the Moon, which is a dominant systematic error. As a result, we successfully achieved a pointing accuracy of 3.3′. This is one order of magnitude smaller than an angular resolution of 36′. This level of accuracy competes with past achievements in other ground-based CMB experiments using observational data from the planets.
- 1 July 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 915 (2) , 88
A Forecast of the Sensitivity on the Measurement of the Optical Depth to Reionization with the GroundBIRD Experiment
We compute the expected sensitivity on measurements of optical depth to reionization for a ground-based experiment at Teide Observatory. We simulate polarized partial sky maps for the GroundBIRD experiment at the frequencies 145 and 220 GHz. We perform fits for the simulated maps with our pixel-based likelihood to extract the optical depth to reionization. The noise levels of polarization maps are estimated as 110 μ K arcmin and 780 μ K arcmin for 145 and 220 GHz, respectively, by assuming a three-year observing campaign and sky coverages of 0.537 for 145 GHz and 0.462 for 220 GHz. Our sensitivities for the optical depth to reionization are found to be σ τ = 0.030 with the simulated GroundBIRD maps, and σ τ = 0.012 by combining with the simulated QUIJOTE maps at 11, 13, 17, 19, 30, and 40 GHz.
- 1 July 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 915 (2) , 88
A Forecast of the Sensitivity on the Measurement of the Optical Depth to Reionization with the GroundBIRD Experiment
We compute the expected sensitivity on measurements of optical depth to reionization for a ground-based experiment at Teide Observatory. We simulate polarized partial sky maps for the GroundBIRD experiment at the frequencies 145 and 220 GHz. We perform fits for the simulated maps with our pixel-based likelihood to extract the optical depth to reionization. The noise levels of polarization maps are estimated as 110 μ K arcmin and 780 μ K arcmin for 145 and 220 GHz, respectively, by assuming a three-year observing campaign and sky coverages of 0.537 for 145 GHz and 0.462 for 220 GHz. Our sensitivities for the optical depth to reionization are found to be σ τ = 0.030 with the simulated GroundBIRD maps, and σ τ = 0.012 by combining with the simulated QUIJOTE maps at 11, 13, 17, 19, 30, and 40 GHz.
- Open Access
- 1 September 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (9) , 095320
A method to measure superconducting transition temperature of microwave kinetic inductance detector by changing power of readout microwaves
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited on the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle lifetime decreases with the number of quasiparticles. Therefore, we can measure the relation between the quasiparticle lifetime and the detector response by rapidly varying the readout power. From this relation, we evaluate the intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc, the physical temperature of the MKID device, and other known parameters. We obtain Tc by comparing the measured lifetime with that acquired using the theoretical model. Using an MKID fabricated with aluminum, we demonstrate this method at a 0.3 K operation. The results are consistent with those obtained by Tc measured by monitoring the transmittance of the readout microwaves with the variation in the device temperature. The method proposed in this paper is applicable to other types, such as a hybrid-type MKID.
- 1 September 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (9) , 095320
Open AccessA method to measure superconducting transition temperature of microwave kinetic inductance detector by changing power of readout microwaves
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited on the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle lifetime decreases with the number of quasiparticles. Therefore, we can measure the relation between the quasiparticle lifetime and the detector response by rapidly varying the readout power. From this relation, we evaluate the intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc, the physical temperature of the MKID device, and other known parameters. We obtain Tc by comparing the measured lifetime with that acquired using the theoretical model. Using an MKID fabricated with aluminum, we demonstrate this method at a 0.3 K operation. The results are consistent with those obtained by Tc measured by monitoring the transmittance of the readout microwaves with the variation in the device temperature. The method proposed in this paper is applicable to other types, such as a hybrid-type MKID.
- Open Access
A method to measure superconducting transition temperature of microwave kinetic inductance detector by changing power of readout microwaves
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited in the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle lifetime decreases with the number of quasiparticles. Therefore, we can measure the relation between the quasiparticle lifetime and the detector response by rapidly varying the readout power. From this relation, we estimate the intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc, the physical temperature of the MKID device, and other known parameters. We obtain Tc by comparing the measured lifetime with that acquired using the theoretical model. Using an MKID fabricated with aluminum, we demonstrate this method at a 0.3 K operation. The results are consistent with those obtained by Tc measured by monitoring the transmittance of the readout microwaves with the variation in the device temperature. The method proposed in this paper is applicable to other types, such as a hybrid-type MKID.
Open AccessA method to measure superconducting transition temperature of microwave kinetic inductance detector by changing power of readout microwaves
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited in the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle lifetime decreases with the number of quasiparticles. Therefore, we can measure the relation between the quasiparticle lifetime and the detector response by rapidly varying the readout power. From this relation, we estimate the intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc, the physical temperature of the MKID device, and other known parameters. We obtain Tc by comparing the measured lifetime with that acquired using the theoretical model. Using an MKID fabricated with aluminum, we demonstrate this method at a 0.3 K operation. The results are consistent with those obtained by Tc measured by monitoring the transmittance of the readout microwaves with the variation in the device temperature. The method proposed in this paper is applicable to other types, such as a hybrid-type MKID.