ECEva Crosas

Eva Crosas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eva Crosas has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-pressure macromolecular crystallography as a tool for studying protein flexibility

    by Julia Lieske, Sofiane Saouane, Patrick Y. A. Reinke, Sven Falke, Wiebke Ewert, Jan Meyer, Tim Pakendorf, Anja Burkhardt, Eva Crosas, Johanna Hakanpää, et al.

    Protein function depends on their conformational flexibility. Complementary to temperature-dependent studies, high-pressure (HP) macromolecular crystallography is well suited to exploring the conformational space of proteins at atomic resolution. We have developed a new HP cell concept for macromolecular X-ray crystallography that overcomes the limitations of current devices. It consists of a single-crystalline sapphire capillary, which is loaded with multiple crystals and pressurized with helium at freely adjustable gas pressures of up to 120 MPa. Studying five different proteins, we generally observed a compression of the protein structures and a decrease in thermal displacement parameters at high pressure. Structurally, observations included the compression of a central tunnel of a biotechnologically relevant enzyme and the stabilization of ligand binding in the membrane protein photosynthetic reaction center of Cereibacter sphaeroides . For two pharmaceutically relevant proteins, the human kinase DRAK2 and SARS-CoV-2 main protease, we identified concerted movements of subdomains. Such knowledge is essential for predictions of protein dynamics and defined conformational states, offering the potential for improved structure-based drug development.

  • Open Access

    Rapid and efficient room-temperature serial synchrotron crystallography using the CFEL TapeDrive

    by Kara A Zielinski, Andreas Prester, Hina Andaleeb, Soi Bui, Oleksandr Yefanov, Lucrezia Catapano, Alessandra Henkel, Max O. Wiedorn, Olga Lorbeer, Eva Crosas, et al.

    Serial crystallography at conventional synchrotron light sources (SSX) offers the possibility to routinely collect data at room temperature using micrometre-sized crystals of biological macromolecules. However, SSX data collection is not yet as routine and currently takes significantly longer than the standard rotation series cryo-crystallography. Thus, its use for high-throughput approaches, such as fragment-based drug screening, where the possibility to measure at physiological temperatures would be a great benefit, is impaired. On the way to high-throughput SSX using a conveyor belt based sample delivery system – the CFEL TapeDrive – with three different proteins of biological relevance (Klebsiella pneumoniae CTX-M-14 β-lactamase, Nectria haematococca xylanase GH11 and Aspergillus flavus urate oxidase), it is shown here that complete datasets can be collected in less than a minute and only minimal amounts of sample are required.


  • Improving data quality and expanding BioSAXS experiments to low-molecular-weight and low-concentration protein samples

    by Albert Castellví, Carlos Pascual-Izarra, Eva Crosas, Marc Malfois, Judith Juanhuix

    The addition of compounds to scavenge the radical species produced during biological small-angle X-ray scattering (BioSAXS) experiments is a common strategy to reduce the effects of radiation damage and produce better quality data. As almost half of the experiments leading to structures deposited in the SASBDB database used scavengers, finding potent scavengers would be advantageous for many experiments. Here, four compounds, three nucleosides and one nitrogenous base, are presented which can act as very effective radical-scavenging additives and increase the critical dose by up to 20 times without altering the stability or reducing the contrast of the tested protein solutions. The efficacy of these scavengers is higher than those commonly used in the field to date, as verified for lysozyme solutions at various concentrations from 7.0 to 0.5 mg ml−1. The compounds are also very efficient at mitigating radiation damage to four proteins with molecular weights ranging from 7 to 240 kDa and pH values from 3 to 8, with the extreme case being catalase at 6.7 mg ml−1, with a scavenging factor exceeding 100. These scavengers can therefore be instrumental in expanding BioSAXS to low-molecular-weight and low-concentration protein samples that were previously inaccessible owing to poor data quality. It is also demonstrated that an increase in the critical dose in standard BioSAXS experiments leads to an increment in the retrieved information, in particular at higher angles, and thus to higher resolution of the model.


  • Open Access

    1 kHz fixed-target serial crystallography using a multilayer monochromator and an integrating pixel detector

    by A. Tolstikova, M. Levantino, O. Yefanov, V. Hennicke, P. Fischer, J. Meyer, A. Mozzanica, S. Redford, E. Crosas, N. L. Opara, et al.

    Reliable sample delivery and efficient use of limited beam time have remained bottlenecks for serial crystallography (SX). Using a high-intensity polychromatic X-ray beam in combination with a newly developed charge-integrating JUNGFRAU detector, we have applied the method of fixed-target SX to collect data at a rate of 1 kHz at a synchrotron-radiation facility. According to our data analysis for the given experimental conditions, only about 3 000 diffraction patterns are required for a high-quality diffraction dataset. With indexing rates of up to 25%, recording of such a dataset takes less than 30 s.


  • Open Access

    On-chip crystallization for serial crystallography experiments and on-chip ligand-binding studies

    by Julia Lieske, Maximilian Cerv, Stefan Kreida, Dana Komadina, Janine Fischer, Miriam Barthelmess, Pontus Fischer, Tim Pakendorf, Oleksandr Yefanov, Valerio Mariani, et al.

    Efficient and reliable sample delivery has remained one of the bottlenecks for serial crystallography experiments. Compared with other methods, fixed-target sample delivery offers the advantage of significantly reduced sample consumption and shorter data collection times owing to higher hit rates. Here, a new method of on-chip crystallization is reported which allows the efficient and reproducible growth of large numbers of protein crystals directly on micro-patterned silicon chips for in-situ serial crystallography experiments. Crystals are grown by sitting-drop vapor diffusion and previously established crystallization conditions can be directly applied. By reducing the number of crystal-handling steps, the method is particularly well suited for sensitive crystal systems. Excessive mother liquor can be efficiently removed from the crystals by blotting, and no sealing of the fixed-target sample holders is required to prevent the crystals from dehydrating. As a consequence, `naked' crystals are obtained on the chip, resulting in very low background scattering levels and making the crystals highly accessible for external manipulation such as the application of ligand solutions. Serial diffraction experiments carried out at cryogenic temperatures at a synchrotron and at room temperature at an X-ray free-electron laser yielded high-quality X-ray structures of the human membrane protein aquaporin 2 and two new ligand-bound structures of thermolysin and the human kinase DRAK2. The results highlight the applicability of the method for future high-throughput on-chip screening of pharmaceutical compounds.