David Grajales
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David Grajales has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Cynthia Ménard
Radiation Oncology, Centre de Recherche du Centre Hospitalier de l’Université de Montréal (CRCHUM), Montréal, Québec, Canada
4 shared publications - Frédéric Leblond
Polytechnique Montreal, Montreal, Canada
4 shared publications - Frédérick Dallaire
Polytechnique Montreal
4 shared publications - Samuel Kadoury
Polytechnique Montreal
4 shared publications - Dominique Trudel
Department of Pathology and Cellular Biology, Centre Hospitalier de l'Université de Montréal, Canada; Centre de Recherche du Centre Hospitalier de l'Université de Montréal, Canada; Montreal Cancer Institute, Canada
3 shared publications - Guillaume Sheehy
CHU Montreal, Research Centre, Montreal, Quebec, Canada
3 shared publications
Latest Publications
- Open Access
- 11 February 2026
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 25
Portable Electrical Impedance Prescreening for Breast tissue suspicious for malignancy: Model Optimization and Clinical Performance of the Julieta Device in a Multicenter Cross-Sectional Study in Colombia
Introduction: Breast cancer remains a leading cause of cancer mortality despite being potentially curable when detected early, particularly in low- and middle-income countries where access to screening is limited. This is largely driven by operational gaps, including limited access to screening and delays in diagnosis and treatment. JULIETA is a portable bioimpedance spectroscopy device designed to identify electrical tissue patterns associated with potentially malignant findings and to prioritize women for further diagnostic evaluation. This study assessed the performance of a hierarchical algorithm integrated into JULIETA to distinguish findings without malignant potential (BI-RADS 1-2) from those with malignant potential (BI-RADS ≥3), using mammography as the reference standard. Methods: A cross-sectional observational study with prospective data collection was conducted between May and July 2024 in four Colombian cities. Adult women undergoing screening or follow-up mammography were evaluated with JULIETA prior to imaging. Impedance-derived features, breast density estimates, and individual risk scores were used to retrain a hierarchical classifier combining Random Forest and SVM-RBF models, using an 80/20 stratified split and cross-validation. Results: A total of 1350 women were recruited (mean age 56.5 ± 8.0 years); 67% were BI-RADS 1-2 and 21% BI-RADS 4. After data cleaning, 673 breasts (469 women) were included. The model achieved 73% sensitivity, 76% specificity, 65.5% positive predictive value, and 82.1% negative predictive value. Conclusion: JULIETA is a feasible, safe, and reproducible noninvasive bioimpedance pre-screening tool that may enable scalable triage and support earlier detection and improved equity when integrated into public health pathways.
- 11 February 2026
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 25
Open AccessPortable Electrical Impedance Prescreening for Breast tissue suspicious for malignancy: Model Optimization and Clinical Performance of the Julieta Device in a Multicenter Cross-Sectional Study in Colombia
Introduction: Breast cancer remains a leading cause of cancer mortality despite being potentially curable when detected early, particularly in low- and middle-income countries where access to screening is limited. This is largely driven by operational gaps, including limited access to screening and delays in diagnosis and treatment. JULIETA is a portable bioimpedance spectroscopy device designed to identify electrical tissue patterns associated with potentially malignant findings and to prioritize women for further diagnostic evaluation. This study assessed the performance of a hierarchical algorithm integrated into JULIETA to distinguish findings without malignant potential (BI-RADS 1-2) from those with malignant potential (BI-RADS ≥3), using mammography as the reference standard. Methods: A cross-sectional observational study with prospective data collection was conducted between May and July 2024 in four Colombian cities. Adult women undergoing screening or follow-up mammography were evaluated with JULIETA prior to imaging. Impedance-derived features, breast density estimates, and individual risk scores were used to retrain a hierarchical classifier combining Random Forest and SVM-RBF models, using an 80/20 stratified split and cross-validation. Results: A total of 1350 women were recruited (mean age 56.5 ± 8.0 years); 67% were BI-RADS 1-2 and 21% BI-RADS 4. After data cleaning, 673 breasts (469 women) were included. The model achieved 73% sensitivity, 76% specificity, 65.5% positive predictive value, and 82.1% negative predictive value. Conclusion: JULIETA is a feasible, safe, and reproducible noninvasive bioimpedance pre-screening tool that may enable scalable triage and support earlier detection and improved equity when integrated into public health pathways.
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 2 (03) , 1-14
Deployment of a real-time prostate cancer confirmation system with Raman spectroscopy: fine-tuning versus test-time adaptation of 1D CNNs
SignificanceProstate cancer (PCa) confirmation during needle-based procedures is limited by the lack of intraoperative diagnostic tools. Raman spectroscopy (RS), combined with classification models, offers a promising solution for real-time tissue characterization, potentially improving sampling accuracy and therapy guidance. However, such models require tissue- and organ-specific data, making deployment in studies challenging due to limited data availability.AimThe aim is to develop a one-dimensional convolutional neural network (1D-CNN) for real-time PCa detection using RS on prospectively collected ex vivo data, leveraging multi-organ pre-training and evaluating two domain adaptation strategies.ApproachA ResNet-based 1D-CNN was trained for binary cancer/normal tissue classification. We implemented a pre-training strategy using retrospective RS data from brain, breast, and prostate (202 patients), along with pre-trained bacterial models, followed by efficient fine-tuning and test-time adaptation (TTA) to adapt to unseen domains.ResultsProspective RS data were acquired using a robotic system from 10 PCa patients (two to five biopsies each). The fine-tuned model achieved 0.76 area under the receiver operating characteristic curve, 0.79 accuracy, 0.83 sensitivity, and 0.72 specificity, outperforming support vector machines. TTA improved predictions when labels were unavailable.ConclusionsPre-trained 1D-CNNs combined with efficient fine-tuning or TTA enable accurate PCa detection in small-cohort settings using real-time RS.
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 2 (03) , 1-14
Open AccessDeployment of a real-time prostate cancer confirmation system with Raman spectroscopy: fine-tuning versus test-time adaptation of 1D CNNs
SignificanceProstate cancer (PCa) confirmation during needle-based procedures is limited by the lack of intraoperative diagnostic tools. Raman spectroscopy (RS), combined with classification models, offers a promising solution for real-time tissue characterization, potentially improving sampling accuracy and therapy guidance. However, such models require tissue- and organ-specific data, making deployment in studies challenging due to limited data availability.AimThe aim is to develop a one-dimensional convolutional neural network (1D-CNN) for real-time PCa detection using RS on prospectively collected ex vivo data, leveraging multi-organ pre-training and evaluating two domain adaptation strategies.ApproachA ResNet-based 1D-CNN was trained for binary cancer/normal tissue classification. We implemented a pre-training strategy using retrospective RS data from brain, breast, and prostate (202 patients), along with pre-trained bacterial models, followed by efficient fine-tuning and test-time adaptation (TTA) to adapt to unseen domains.ResultsProspective RS data were acquired using a robotic system from 10 PCa patients (two to five biopsies each). The fine-tuned model achieved 0.76 area under the receiver operating characteristic curve, 0.79 accuracy, 0.83 sensitivity, and 0.72 specificity, outperforming support vector machines. TTA improved predictions when labels were unavailable.ConclusionsPre-trained 1D-CNNs combined with efficient fine-tuning or TTA enable accurate PCa detection in small-cohort settings using real-time RS.
- 4 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (6) , 1103-1111
Robot-assisted biopsy sampling for online Raman spectroscopy cancer confirmation in the operating room
Purpose Cancer confirmation in the operating room (OR) is crucial to improve local control in cancer therapies. Histopathological analysis remains the gold standard, but there is a lack of real-time in situ cancer confirmation to support margin confirmation or remnant tissue. Raman spectroscopy (RS), as a label-free optical technique, has proven its power in cancer detection and, when integrated into a robotic assistance system, can positively impact the efficiency of procedures and the quality of life of patients, avoiding potential recurrence. Methods A workflow is proposed where a 6-DOF robotic system (optical camera + MECA500 robotic arm) assists the characterization of fresh tissue samples using RS. Three calibration methods are compared for the robot, and the temporal efficiency is compared with standard hand-held analysis. For healthy/cancerous tissue discrimination, a 1D-convolutional neural network is proposed and tested on three ex vivo datasets (brain, breast, and prostate) containing processed RS and histopathology ground truth. Results The robot achieves a minimum error of 0.20 mm (0.12) on a set of 30 test landmarks and demonstrates significant time reduction in 4 of the 5 proposed tasks. The proposed classification model can identify brain, breast, and prostate cancer with an accuracy of 0.83 (0.02), 0.93 (0.01), and 0.71 (0.01), respectively. Conclusion Automated RS analysis with deep learning demonstrates promising classification performance compared to commonly used support vector machines. Robotic assistance in tissue characterization can contribute to highly accurate, rapid, and robust biopsy analysis in the OR. These two elements are an important step toward real-time cancer confirmation using RS and OR integration.
- 4 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (6) , 1103-1111
Robot-assisted biopsy sampling for online Raman spectroscopy cancer confirmation in the operating room
Purpose Cancer confirmation in the operating room (OR) is crucial to improve local control in cancer therapies. Histopathological analysis remains the gold standard, but there is a lack of real-time in situ cancer confirmation to support margin confirmation or remnant tissue. Raman spectroscopy (RS), as a label-free optical technique, has proven its power in cancer detection and, when integrated into a robotic assistance system, can positively impact the efficiency of procedures and the quality of life of patients, avoiding potential recurrence. Methods A workflow is proposed where a 6-DOF robotic system (optical camera + MECA500 robotic arm) assists the characterization of fresh tissue samples using RS. Three calibration methods are compared for the robot, and the temporal efficiency is compared with standard hand-held analysis. For healthy/cancerous tissue discrimination, a 1D-convolutional neural network is proposed and tested on three ex vivo datasets (brain, breast, and prostate) containing processed RS and histopathology ground truth. Results The robot achieves a minimum error of 0.20 mm (0.12) on a set of 30 test landmarks and demonstrates significant time reduction in 4 of the 5 proposed tasks. The proposed classification model can identify brain, breast, and prostate cancer with an accuracy of 0.83 (0.02), 0.93 (0.01), and 0.71 (0.01), respectively. Conclusion Automated RS analysis with deep learning demonstrates promising classification performance compared to commonly used support vector machines. Robotic assistance in tissue characterization can contribute to highly accurate, rapid, and robust biopsy analysis in the OR. These two elements are an important step toward real-time cancer confirmation using RS and OR integration.
- 7 October 2023
- Published by Springer Nature
- p. 17-28
Towards Real-Time Confirmation of Breast Cancer in the OR Using CNN-Based Raman Spectroscopy Classification
- 7 October 2023
- Published by Springer Nature
- p. 17-28
Towards Real-Time Confirmation of Breast Cancer in the OR Using CNN-Based Raman Spectroscopy Classification
- Open Access
- 9 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 095004-16
Image-guided Raman spectroscopy navigation system to improve transperineal prostate cancer detection. Part 2: in-vivo tumor-targeting using a classification model combining spectral and MRI-radiomics features
Transperineal biopsy and high-dose-rate (HDR) brachytherapy are two needle-based procedures for diagnosing and treating prostate cancer (PCa), respectively. HDR brachytherapy allows the delivery of a considerable dose of radiation to the tumor site using temporary implants while reducing the surrounding tissue involvement.1,2 Although using transrectal ultrasound (TRUS)-guided biopsy is the standard of care, it can have up to 30% false-negative rates and does not allow in situ characterization.3,4 It is clear that the efficiency of both techniques relies significantly on accurate localization of the tumor and needle.
- 9 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 095004-16
Open AccessImage-guided Raman spectroscopy navigation system to improve transperineal prostate cancer detection. Part 2: in-vivo tumor-targeting using a classification model combining spectral and MRI-radiomics features
Transperineal biopsy and high-dose-rate (HDR) brachytherapy are two needle-based procedures for diagnosing and treating prostate cancer (PCa), respectively. HDR brachytherapy allows the delivery of a considerable dose of radiation to the tumor site using temporary implants while reducing the surrounding tissue involvement.1,2 Although using transrectal ultrasound (TRUS)-guided biopsy is the standard of care, it can have up to 30% false-negative rates and does not allow in situ characterization.3,4 It is clear that the efficiency of both techniques relies significantly on accurate localization of the tumor and needle.
- Open Access
- 1 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 095003-14
Image-guided Raman spectroscopy navigation system to improve transperineal prostate cancer detection. Part 1: Raman spectroscopy fiber-optics system and in situ tissue characterization
In 2020, 1.4 million cases of prostate cancer (PCa) were diagnosed worldwide with an estimated 375,000 deaths.1 In the United States, PCa is the most common and second deadliest cancer for men, accounting for 11% of total cancer deaths.2 Trans-rectal ultrasound-guided (TRUS) biopsy procedure is the standard of care for diagnosis of PCa due to its real-time capabilities and convenience.3 – 5 However, the genotypic and phenotypic heterogeneity of prostate tumors presents challenges in validating their position, type, extent, and grade to establish the diagnosis and prognosis.6,7 As a result, a significant rate of false negatives is reported for prostate biopsy procedures, reaching up to 30%.8,9
- 1 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 095003-14
Open AccessImage-guided Raman spectroscopy navigation system to improve transperineal prostate cancer detection. Part 1: Raman spectroscopy fiber-optics system and in situ tissue characterization
In 2020, 1.4 million cases of prostate cancer (PCa) were diagnosed worldwide with an estimated 375,000 deaths.1 In the United States, PCa is the most common and second deadliest cancer for men, accounting for 11% of total cancer deaths.2 Trans-rectal ultrasound-guided (TRUS) biopsy procedure is the standard of care for diagnosis of PCa due to its real-time capabilities and convenience.3 – 5 However, the genotypic and phenotypic heterogeneity of prostate tumors presents challenges in validating their position, type, extent, and grade to establish the diagnosis and prognosis.6,7 As a result, a significant rate of false negatives is reported for prostate biopsy procedures, reaching up to 30%.8,9
- Open Access
- 17 October 2019
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 94,p. 97-101
Effective sericin-fibroin separation from Bombyx mori silkworms fibers and low-cost salt removal from fibroin solution
Silk from Bombyx mori has two main proteins: fibroin and sericin. Fibroin is a protein that exhibits good biocompatibility and high surface reactivity, desirable properties for many biomedical applications. Sericin is related with adverse immune response in some medical uses. Therefore, its removal (degumming) is desirable in almost all fields, including the textile industry and biological applications. In this study, three degumming methods (distilled water, liquid neutral detergent and sodium carbonate solution) were evaluated using Raman spectroscopy. Degummed silk treated with sodium carbonate solution exhibits a pattern consistent with previous studies for sericin-free fibroin, and significant differences with the untreated silk pattern. Also, degummed fibroin fibers were dissolved in a calcium chloride solution, in pursuit of a more versatile material. Additionally, different porous membranes of dialysis tubes were tested to remove residual salts, and were compared by conductivity measurements and EDS analysis, identifying good performance for an affordable food cellulose membrane. The results showed that it is possible to obtain fibroin with adequate chemical properties, using low-cost process and membrane of dialysis tubes.
- 17 October 2019
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 94,p. 97-101
Open AccessEffective sericin-fibroin separation from Bombyx mori silkworms fibers and low-cost salt removal from fibroin solution
Silk from Bombyx mori has two main proteins: fibroin and sericin. Fibroin is a protein that exhibits good biocompatibility and high surface reactivity, desirable properties for many biomedical applications. Sericin is related with adverse immune response in some medical uses. Therefore, its removal (degumming) is desirable in almost all fields, including the textile industry and biological applications. In this study, three degumming methods (distilled water, liquid neutral detergent and sodium carbonate solution) were evaluated using Raman spectroscopy. Degummed silk treated with sodium carbonate solution exhibits a pattern consistent with previous studies for sericin-free fibroin, and significant differences with the untreated silk pattern. Also, degummed fibroin fibers were dissolved in a calcium chloride solution, in pursuit of a more versatile material. Additionally, different porous membranes of dialysis tubes were tested to remove residual salts, and were compared by conductivity measurements and EDS analysis, identifying good performance for an affordable food cellulose membrane. The results showed that it is possible to obtain fibroin with adequate chemical properties, using low-cost process and membrane of dialysis tubes.