Minshun Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Minshun Wu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cheng-Fu Yang
Department of Chemical and Materials Engineering, National University of Kaohsiung, Kaohsiung 811, Taiwan
1 shared publication - Guohe Zhang
Xi’an Jiaotong University
1 shared publication - Jiangtao Xu
School of Microelectronics, Xian Jiaotong University, Xian, China
1 shared publication - Ruizhi Zhang
School of Microelectronics, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Sufen Wei
School of Ocean Information Engineering, Jimei University, Xiamen 361021, China
1 shared publication - Yawei Wang
School of Microelectronics, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
- 21 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 814
A High-Accuracy Ultra-Low-Power Offset-Cancelation On-Off Bandgap Reference for Implantable Medical Electronics
An ultra-low-power and high-accuracy on-off bandgap reference (BGR) is demonstrated in this paper for implantable medical electronics. The proposed BGR shows an average current consumption of 78 nA under 2.8 V supply and an output voltage of 1.17 V with an untrimmed accuracy of 0.69%. The on-off bandgap combined with sample-and-hold switched-RC filter is developed to reduce power consumption and noise. The on-off mechanism allows a relatively higher current in the sample phase to alleviate the process variation of bipolar transistors. To compensate the error caused by operational amplifier offset, the correlated double sampling strategy is adopted in the BGR. The proposed BGR is implemented in 0.35 μm standard CMOS process and occupies a total area of 0.063 mm2. Measurement results show that the circuit works properly in the supply voltage range of 1.8–3.2 V and achieves a line regulation of 0.59 mV/V. When the temperature varies from −20 to 80 °C, an average temperature coefficient of 19.6 ppm/°C is achieved.
- 21 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 814
Open AccessA High-Accuracy Ultra-Low-Power Offset-Cancelation On-Off Bandgap Reference for Implantable Medical Electronics
An ultra-low-power and high-accuracy on-off bandgap reference (BGR) is demonstrated in this paper for implantable medical electronics. The proposed BGR shows an average current consumption of 78 nA under 2.8 V supply and an output voltage of 1.17 V with an untrimmed accuracy of 0.69%. The on-off bandgap combined with sample-and-hold switched-RC filter is developed to reduce power consumption and noise. The on-off mechanism allows a relatively higher current in the sample phase to alleviate the process variation of bipolar transistors. To compensate the error caused by operational amplifier offset, the correlated double sampling strategy is adopted in the BGR. The proposed BGR is implemented in 0.35 μm standard CMOS process and occupies a total area of 0.063 mm2. Measurement results show that the circuit works properly in the supply voltage range of 1.8–3.2 V and achieves a line regulation of 0.59 mV/V. When the temperature varies from −20 to 80 °C, an average temperature coefficient of 19.6 ppm/°C is achieved.