Socrates Fragoulis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Socrates Fragoulis has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Apostolos Roubelakis
A Department of Surgery, Division of Cardiac Surgery , St. Michael's Hospital, University of Toronto , Toronto , Canada
2 shared publicationsConstantinos Contrafouris
1st Cardiac Surgery Department, Onassis Cardiac Surgery Center, Athens, Greece
2 shared publications- Dimos Karangelis
Department of Cardiothoracic Surgery, University General Hospital, Democritus University of Thrace, 68100 Alexandroupolis, Greece
2 shared publications - Nektarios Kogerakis
2(nd) Cardiac Surgery Department, Onassis Cardiac Surgery Center, Athens, Greece
2 shared publications Stamatis Adamopoulos
Heart Failure, Transplant, Mechanical Circulatory Support Units, Onassis Cardiac Surgery Center, Athens, Greece
2 shared publicationsA Bairaktaris
First Department of Adult Cardiac Surgery, Onassis Cardiac Surgery Center, Athens, Greece
1 shared publication
Latest Publications
- Open Access
- 30 September 2024
- Published by Elsevier in Hellenic Journal of Cardiology
- Vol. 88, 13-20
Central versus peripheral VA ECMO for cardiogenic shock: an 8-year experience of a tertiary cardiac surgery center in Greece
- 30 September 2024
- Published by Elsevier in Hellenic Journal of Cardiology
- Vol. 88, 13-20
Open AccessCentral versus peripheral VA ECMO for cardiogenic shock: an 8-year experience of a tertiary cardiac surgery center in Greece
- Open Access
- 8 July 2023
- Published by Elsevier in Hellenic Journal of Cardiology
- Vol. 74, 81-82
Retransplantation in Greece: Ethical and practical considerations
- 8 July 2023
- Published by Elsevier in Hellenic Journal of Cardiology
- Vol. 74, 81-82
Open AccessRetransplantation in Greece: Ethical and practical considerations
- 30 June 2021
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 29 (8) , 853
Internal thoracic arteries with early postoperative arteritis
- 30 June 2021
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 29 (8) , 853
Internal thoracic arteries with early postoperative arteritis
- 21 July 2019
- Published by SAGE Publications in Perfusion
- Vol. 35 (2) , 166-168
Reversible right heart failure after redo operation of a post-traumatic Gerbode defect
Introduction: Gerbode defect is a rare entity and represents a small percent of all congenital defects. If left untreated, right heart failure may occur. Case report: We describe a redo case of a 47-year-old patient complaining about the signs and symptoms of decompensating right heart failure after a surgically treated post-traumatic Gerbode defect 8 years prior. Discussion: Although it is described as a congenital defect, in clinical practice, results mostly as an iatrogenic complication after heart valve surgery, endocarditis, nodal ablation, or post-traumatic defect. Surgical correction is the treatment of choice independently of the provided cause. Dimensions, the position of the defect, are very important factors for the interventional approach. At 12 months post-operatively, the patient remained completely asymptomatic. He has an active life and presents all the echocardiographic metrics within normal values. Conclusion: We strongly recommend that in cardiac areas where high wall tension is applied, durable materials such as Dacron should be used. We also believe that a well-documented discussion with the patient, about his medical condition and his therapeutic alternatives, is imperative.
- 21 July 2019
- Published by SAGE Publications in Perfusion
- Vol. 35 (2) , 166-168
Reversible right heart failure after redo operation of a post-traumatic Gerbode defect
Introduction: Gerbode defect is a rare entity and represents a small percent of all congenital defects. If left untreated, right heart failure may occur. Case report: We describe a redo case of a 47-year-old patient complaining about the signs and symptoms of decompensating right heart failure after a surgically treated post-traumatic Gerbode defect 8 years prior. Discussion: Although it is described as a congenital defect, in clinical practice, results mostly as an iatrogenic complication after heart valve surgery, endocarditis, nodal ablation, or post-traumatic defect. Surgical correction is the treatment of choice independently of the provided cause. Dimensions, the position of the defect, are very important factors for the interventional approach. At 12 months post-operatively, the patient remained completely asymptomatic. He has an active life and presents all the echocardiographic metrics within normal values. Conclusion: We strongly recommend that in cardiac areas where high wall tension is applied, durable materials such as Dacron should be used. We also believe that a well-documented discussion with the patient, about his medical condition and his therapeutic alternatives, is imperative.
- 26 December 2016
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 15 (2) , 83-91
What is the role of sutureless aortic valves in today’s armamentarium?
Introduction: Sutureless and rapid-deployment aortic bioprostheses represent an emerging and promising technology for the treatment of aortic valve stenosis. Unlike traditional aortic bioprostheses, these devices are not hand-sewn, thus allowing a significant reduction in operative times, while facilitating minimally invasive surgery and complex cardiac interventions. Sutureless aortic valve replacement represents a less invasive treatment option and an excellent alternative to conventional aortic valve replacement in elderly and higher risk patients. Areas covered: This review summarizes the current literature on sutureless and rapid-deployment aortic bioprostheses, focusing on their hemodynamic and clinical performance. Moreover, we highlight clinical caveats associated with these devices and report the current recommendations for their use, as advocated by experts in the field. Expert commentary: Finally, we summarize our group’s technical modification with regards to positioning of these bioprostheses and propose some technical aspects which could decrease post-procedural permanent pacemaker requirement.
- 26 December 2016
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 15 (2) , 83-91
What is the role of sutureless aortic valves in today’s armamentarium?
Introduction: Sutureless and rapid-deployment aortic bioprostheses represent an emerging and promising technology for the treatment of aortic valve stenosis. Unlike traditional aortic bioprostheses, these devices are not hand-sewn, thus allowing a significant reduction in operative times, while facilitating minimally invasive surgery and complex cardiac interventions. Sutureless aortic valve replacement represents a less invasive treatment option and an excellent alternative to conventional aortic valve replacement in elderly and higher risk patients. Areas covered: This review summarizes the current literature on sutureless and rapid-deployment aortic bioprostheses, focusing on their hemodynamic and clinical performance. Moreover, we highlight clinical caveats associated with these devices and report the current recommendations for their use, as advocated by experts in the field. Expert commentary: Finally, we summarize our group’s technical modification with regards to positioning of these bioprostheses and propose some technical aspects which could decrease post-procedural permanent pacemaker requirement.
- 21 July 2016
- Published by SAGE Publications in Perfusion
- Vol. 32 (1) , 84-86
Treatment of a pseudoaneurysm of the ascending aorta in association with aortopulmonary fistula following acute Type A dissection
This report describes a rare case of aortic pseudoaneurysm with an aortopulmonary fistula in a 69-year-old woman two years following repair of a Type A aortic dissection. The patient presented with NYHA Class IV symptoms having deteriorated rapidly over a course of six weeks. We describe our successful surgical repair following a failed attempt of percutaneous closure with an atrial septal occlusion device.
- 21 July 2016
- Published by SAGE Publications in Perfusion
- Vol. 32 (1) , 84-86
Treatment of a pseudoaneurysm of the ascending aorta in association with aortopulmonary fistula following acute Type A dissection
This report describes a rare case of aortic pseudoaneurysm with an aortopulmonary fistula in a 69-year-old woman two years following repair of a Type A aortic dissection. The patient presented with NYHA Class IV symptoms having deteriorated rapidly over a course of six weeks. We describe our successful surgical repair following a failed attempt of percutaneous closure with an atrial septal occlusion device.
- 6 October 2014
- Published by SAGE Publications in Perfusion
- Vol. 30 (4) , 345-348
Early onset of prosthesis failure after aortic valve replacement
We report an unusual case of a 78-year-old male who underwent an aortic valve replacement with a 21 mm Labcor tissue porcine aortic valve due to symptomatic aortic stenosis of his native valve. Only 3 months after an uncomplicated postoperative course, on a routine follow-up, transthoracic echo showed restrictive motion of the non-coronary cusp, incomplete closure of the coaptation line and severe aortic regurgitation. The patient was scheduled for a new operation during which the previous prosthetic valve was explanted and a different model was used.
- 6 October 2014
- Published by SAGE Publications in Perfusion
- Vol. 30 (4) , 345-348
Early onset of prosthesis failure after aortic valve replacement
We report an unusual case of a 78-year-old male who underwent an aortic valve replacement with a 21 mm Labcor tissue porcine aortic valve due to symptomatic aortic stenosis of his native valve. Only 3 months after an uncomplicated postoperative course, on a routine follow-up, transthoracic echo showed restrictive motion of the non-coronary cusp, incomplete closure of the coaptation line and severe aortic regurgitation. The patient was scheduled for a new operation during which the previous prosthetic valve was explanted and a different model was used.
- Open Access
- 1 January 2014
- Published by Medknow in Journal of Emergencies, Trauma, and Shock
- Vol. 7 (3) , 244-6
Acute aortic dissection is independent of weather conditions but statistically correlates with day of the week
J Emerg Trauma Shock, official publication of the INDO-US Emergency and Trauma Collaborative
- 1 January 2014
- Published by Medknow in Journal of Emergencies, Trauma, and Shock
- Vol. 7 (3) , 244-6
Open AccessAcute aortic dissection is independent of weather conditions but statistically correlates with day of the week
J Emerg Trauma Shock, official publication of the INDO-US Emergency and Trauma Collaborative
- Open Access
- 1 October 2008
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 34 (4) , 907
Fractured prosthetic valve leaflet
A 43-year-old male patient suffered from acute dyspnea while jogging. The patient had a mitral valve replacement (Duromedics 27 mm) 12 years ago. During emergent reoperation, the prosthetic mitral valve was found with one leaflet missing. CT scan revealed two fragments of the prosthetic leaflet (Fig. 1 ) wedged in the arterial tree.
- 1 October 2008
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 34 (4) , 907
Open AccessFractured prosthetic valve leaflet
A 43-year-old male patient suffered from acute dyspnea while jogging. The patient had a mitral valve replacement (Duromedics 27 mm) 12 years ago. During emergent reoperation, the prosthetic mitral valve was found with one leaflet missing. CT scan revealed two fragments of the prosthetic leaflet (Fig. 1 ) wedged in the arterial tree.
- Open Access
- 30 December 2006
- Published by PAGEPress Publications in Monaldi Archives for Chest Disease
- Vol. 65 (4) , 222-4
Malignant triton tumour of the anterior mediastinum as incidental finding
A rare case of malignant peripheral nerve sheath tumour with rhabdomyoblastic differentiation (malignant triton tumour) of the anterior mediastinum in a 30-yearold male is reported. The tumour was an incidental finding during the diagnostic work-up following a motor vehicle accident. The patient underwent median sternotomy with a tumour resection performed. Local relapse was suspected one month later, as per the chest CT-scan, and post-operative chemoradiation was applied, which produced a response. Twelve months later the patient is doing well while radiological findings remain invariable. Localization of a triton tumour in the anterior mediastinum is extremely rare, adjuvant treatment is necessary, recurrence frequently occurs and the prognosis is dismal.
- 30 December 2006
- Published by PAGEPress Publications in Monaldi Archives for Chest Disease
- Vol. 65 (4) , 222-4
Open AccessMalignant triton tumour of the anterior mediastinum as incidental finding
A rare case of malignant peripheral nerve sheath tumour with rhabdomyoblastic differentiation (malignant triton tumour) of the anterior mediastinum in a 30-yearold male is reported. The tumour was an incidental finding during the diagnostic work-up following a motor vehicle accident. The patient underwent median sternotomy with a tumour resection performed. Local relapse was suspected one month later, as per the chest CT-scan, and post-operative chemoradiation was applied, which produced a response. Twelve months later the patient is doing well while radiological findings remain invariable. Localization of a triton tumour in the anterior mediastinum is extremely rare, adjuvant treatment is necessary, recurrence frequently occurs and the prognosis is dismal.