Rukmani Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rukmani Singh has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Vishnu Priye
Department of Electronics Engineering, Indian Institute of Technology (Indian School of Mines), Dhanbad, India
4 shared publications Vishnu Priye
Indian Institute of Technology (Indian School of Mines)
3 shared publications- Devendra Chack
Department of Electronics Engineering, Indian Institute of Technology (ISM) Dhanbad, Dhanbad, India
2 shared publications - Francesco Chiavaioli
Istituto di Fisica Applicata “Nello Carrara”, Consiglio Nazionale delle Ricerche
2 shared publications - Ritu Raj Singh
Department of Electronics and Communication Engineering, Netaji Subhas University of Technology, New Delhi 110078, India
2 shared publications - Chen Chen
School of Life Science and Technology, Xidian University
1 shared publication
Latest Publications
- Open Access
- 20 August 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7 (4)
Design of subwavelength grating-based bimodal waveguide interferometric sensor in visible range for enhancing diagnostics sensitivity
The demand for point-of-care biosensors capable of rapid, accurate, and specific detection has grown significantly, particularly in the wake of the COVID-19 pandemic. Silicon photonics-based biosensors, based on evanescent wave sensing, have positioned as competitive candidates to meet these needs due to their high index contrast, compact size, high sensitivity, and specificity, CMOS compatibility, and low cost. Among various configurations, the bimodal waveguide (BiMW) interferometer stands out for its high sensitivity and compact footprint. Meanwhile, subwavelength grating (SWG) waveguides offer enhanced sensitivity by providing a larger active sensing area compared to conventional waveguides. In this work, we propose integrating SWG waveguides with BiMW interferometers, using silicon nitride (Si3N4) as the guiding material in the visible wavelength range to improve sensing performance through enhanced sensitivity and compactness. Si3N4 offers advantages such as low scattering losses and chemical stability in biological environments, while operation in visible range increases compatibility with biological assays, making this approach novel. We present a comprehensive device design, optimization, and analysis of the SWG-based BiMW interferometer for refractive index sensing applications. Three - dimensional (3D) full vectorial simulations were conducted using the finite element method (FEM) in COMSOL Multiphysics for the device design and optimizations. The proposed device demonstrates notable improvements in sensing performance, with an intrinsic bulk sensitivity of 0.1479 RIU/RIU, intrinsic surface sensitivity of 2.41×10⁻⁴ RIU/nm, and a theoretical phase sensitivity of 1318 rad/RIU/mm, all achieved within a compact footprint.
- 20 August 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 7 (4)
Open AccessDesign of subwavelength grating-based bimodal waveguide interferometric sensor in visible range for enhancing diagnostics sensitivity
The demand for point-of-care biosensors capable of rapid, accurate, and specific detection has grown significantly, particularly in the wake of the COVID-19 pandemic. Silicon photonics-based biosensors, based on evanescent wave sensing, have positioned as competitive candidates to meet these needs due to their high index contrast, compact size, high sensitivity, and specificity, CMOS compatibility, and low cost. Among various configurations, the bimodal waveguide (BiMW) interferometer stands out for its high sensitivity and compact footprint. Meanwhile, subwavelength grating (SWG) waveguides offer enhanced sensitivity by providing a larger active sensing area compared to conventional waveguides. In this work, we propose integrating SWG waveguides with BiMW interferometers, using silicon nitride (Si3N4) as the guiding material in the visible wavelength range to improve sensing performance through enhanced sensitivity and compactness. Si3N4 offers advantages such as low scattering losses and chemical stability in biological environments, while operation in visible range increases compatibility with biological assays, making this approach novel. We present a comprehensive device design, optimization, and analysis of the SWG-based BiMW interferometer for refractive index sensing applications. Three - dimensional (3D) full vectorial simulations were conducted using the finite element method (FEM) in COMSOL Multiphysics for the device design and optimizations. The proposed device demonstrates notable improvements in sensing performance, with an intrinsic bulk sensitivity of 0.1479 RIU/RIU, intrinsic surface sensitivity of 2.41×10⁻⁴ RIU/nm, and a theoretical phase sensitivity of 1318 rad/RIU/mm, all achieved within a compact footprint.
- Open Access
- 7 July 2025
- Published by Elsevier in Journal of Advanced Research
- Vol. 82, 295-313
Evanescent wave-based optical biosensors for innovations, medical application and future perspectives
- 7 July 2025
- Published by Elsevier in Journal of Advanced Research
- Vol. 82, 295-313
Open AccessEvanescent wave-based optical biosensors for innovations, medical application and future perspectives
- Open Access
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Reviews
- Vol. 2, 157-169
Functional Nanomaterial Coatings on Optical Fibers: Toward Enhanced Biosensing Performance
This work explores the recent advances in the integration of functional nanomaterial coatings with optical fibers to enhance the biosensing performance applied to various domains, including medical diagnostics, environmental monitoring, and food safety. Optical fiber-based biosensors (OFBs) have shown significant advantages over planar/chip-based technology, such as unique control in guiding light, extreme miniaturization, lightness, and remote capabilities. Through different techniques like surface plasmon resonance (SPR), evanescent wave sensing, or other resonance-based approaches, these biosensors showcase rapid, highly selective, and accurate detection of target analytes. Nanomaterials, such as metals, oxides, and polymers are employed as functional coatings to improve not only sensitivity, specificity, and stability under challenging conditions, but also multi-analyte sensing and multi-functionality. Advanced nanotechnological fabrication methods, such as electrospinning, chemical vapor deposition, atomic layer deposition, and self-assembly monolayer allow precise control over nanomaterial coating, optimizing the performance in different applications. Despite low-cost scalability, reproducibility in complex environments mimicking clinical settings, and effective surface functionalization remain open challenges in the field, promising solutions for real-world deployment in terms of point-of-care (POC) diagnostics and in vivo sensing are showcased.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Reviews
- Vol. 2, 157-169
Open AccessFunctional Nanomaterial Coatings on Optical Fibers: Toward Enhanced Biosensing Performance
This work explores the recent advances in the integration of functional nanomaterial coatings with optical fibers to enhance the biosensing performance applied to various domains, including medical diagnostics, environmental monitoring, and food safety. Optical fiber-based biosensors (OFBs) have shown significant advantages over planar/chip-based technology, such as unique control in guiding light, extreme miniaturization, lightness, and remote capabilities. Through different techniques like surface plasmon resonance (SPR), evanescent wave sensing, or other resonance-based approaches, these biosensors showcase rapid, highly selective, and accurate detection of target analytes. Nanomaterials, such as metals, oxides, and polymers are employed as functional coatings to improve not only sensitivity, specificity, and stability under challenging conditions, but also multi-analyte sensing and multi-functionality. Advanced nanotechnological fabrication methods, such as electrospinning, chemical vapor deposition, atomic layer deposition, and self-assembly monolayer allow precise control over nanomaterial coating, optimizing the performance in different applications. Despite low-cost scalability, reproducibility in complex environments mimicking clinical settings, and effective surface functionalization remain open challenges in the field, promising solutions for real-world deployment in terms of point-of-care (POC) diagnostics and in vivo sensing are showcased.
- 4 September 2022
- Published by Springer Nature
- p. 747-756
Silicon on Insulator-Based Ultra-Small Micro-Ring Resonator for Temperature Sensing
- 4 September 2022
- Published by Springer Nature
- p. 747-756
Silicon on Insulator-Based Ultra-Small Micro-Ring Resonator for Temperature Sensing
- 4 September 2022
- Published by Springer Nature
- p. 273-281
High Sensitive Surface Refractive Index Sensor Using Multiple Vertical Silicon Nanowire-Based PIC Waveguide
- 4 September 2022
- Published by Springer Nature
- p. 273-281
High Sensitive Surface Refractive Index Sensor Using Multiple Vertical Silicon Nanowire-Based PIC Waveguide
- 21 July 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (22) , 6510-6517
SNROW-based highly sensitive label-free surface biosensor for hepatitis B detection
Despite the availability of effective hepatitis B vaccinations, the hepatitis B virus remains a serious global health concern. It is expected that early detection could aid in initiating therapy before the infection progresses to liver damage. A silicon nanowire rectangular optical waveguide has been demonstrated theoretically to detect the surface antigen of hepatitis B “HBsAg” based on label-free surface sensing using finite-element method-based COMSOL Multiphysics. Different procedural segments of the biomarker detection have been mimicked on the surface of a waveguide as adlayers to investigate the device theoretically. Initially, the parameters of the waveguide have been optimized to provide a large interaction of light and bio-analyte, i.e., to provide high sensitivity. The analyses are first performed at the waveguide level based on the light-analyte interaction. Furthermore, performances of the sensor have been obtained by incorporating this waveguide structure in the sensing arm of the Mach–Zehnder interferometer. The device structure shows ultra-high surface sensitivities such as phase surface sensitivity of 7.03 × 2 π r a d / n m and MZI surface sensitivity of 3421.89 µW/nm with an excellent detection limit of 2.92 × 10 − 3 p g / m m 2 for HBsAg detection. The proposed device can measure the HBsAg concentration as low as 0.00973 ng/mL, which is significantly low to detect the infection in an early stage.
- 21 July 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (22) , 6510-6517
SNROW-based highly sensitive label-free surface biosensor for hepatitis B detection
Despite the availability of effective hepatitis B vaccinations, the hepatitis B virus remains a serious global health concern. It is expected that early detection could aid in initiating therapy before the infection progresses to liver damage. A silicon nanowire rectangular optical waveguide has been demonstrated theoretically to detect the surface antigen of hepatitis B “HBsAg” based on label-free surface sensing using finite-element method-based COMSOL Multiphysics. Different procedural segments of the biomarker detection have been mimicked on the surface of a waveguide as adlayers to investigate the device theoretically. Initially, the parameters of the waveguide have been optimized to provide a large interaction of light and bio-analyte, i.e., to provide high sensitivity. The analyses are first performed at the waveguide level based on the light-analyte interaction. Furthermore, performances of the sensor have been obtained by incorporating this waveguide structure in the sensing arm of the Mach–Zehnder interferometer. The device structure shows ultra-high surface sensitivities such as phase surface sensitivity of 7.03 × 2 π r a d / n m and MZI surface sensitivity of 3421.89 µW/nm with an excellent detection limit of 2.92 × 10 − 3 p g / m m 2 for HBsAg detection. The proposed device can measure the HBsAg concentration as low as 0.00973 ng/mL, which is significantly low to detect the infection in an early stage.
- 9 January 2022
- Published by Taylor & Francis in IETE Technical Review
- Vol. 39 (6) , 1463-1472
Highly Sensitive Refractive Index-Based Sensor for DNA Hybridization Using Subwavelength Grating Waveguide
A biosensor for detecting DNA hybridization via refractive index sensing has been demonstrated using a subwavelength grating (SWG) waveguide. Waveguide dimensions are selected by parametric optimizations to increase the mode-analyte overlap with considerations of typical silicon-on-insulator fabrications technology. DNA layer is added with a linker layer on silicon pillars of the SWG waveguide to optimize and detect the DNA hybridization. Some essential characteristics such as mode overlap factor, change in effective refractive index, waveguide sensitivity, and shift in resonance wavelength are computed for the different dimensional parameters of the SWG waveguide in DNA hybridization along with mode field intensity and normalized power using the finite element method. The DNA hybridization is shown by variation in normalized power of interacting light in cladding region of the waveguide for 0% to 100% fractional change of dsDNA and ssDNA. Waveguide sensitivity, shift in resonance wavelength, device sensitivity, and intrinsic limit of detection are obtained to ∼ 0.157, 7.01, 605 nm/RIU, and 1.30 × 10−4 RIU, respectively, for the optimized structure of SWG waveguide in sensing of DNA hybridization, which could be suitable aspects for detecting DNA hybridization.
- 9 January 2022
- Published by Taylor & Francis in IETE Technical Review
- Vol. 39 (6) , 1463-1472
Highly Sensitive Refractive Index-Based Sensor for DNA Hybridization Using Subwavelength Grating Waveguide
A biosensor for detecting DNA hybridization via refractive index sensing has been demonstrated using a subwavelength grating (SWG) waveguide. Waveguide dimensions are selected by parametric optimizations to increase the mode-analyte overlap with considerations of typical silicon-on-insulator fabrications technology. DNA layer is added with a linker layer on silicon pillars of the SWG waveguide to optimize and detect the DNA hybridization. Some essential characteristics such as mode overlap factor, change in effective refractive index, waveguide sensitivity, and shift in resonance wavelength are computed for the different dimensional parameters of the SWG waveguide in DNA hybridization along with mode field intensity and normalized power using the finite element method. The DNA hybridization is shown by variation in normalized power of interacting light in cladding region of the waveguide for 0% to 100% fractional change of dsDNA and ssDNA. Waveguide sensitivity, shift in resonance wavelength, device sensitivity, and intrinsic limit of detection are obtained to ∼ 0.157, 7.01, 605 nm/RIU, and 1.30 × 10−4 RIU, respectively, for the optimized structure of SWG waveguide in sensing of DNA hybridization, which could be suitable aspects for detecting DNA hybridization.
- 5 January 2021
- Published by Springer Nature in Silicon
- Vol. 14 (3) , 859-867
Si3N4 – SiO2 Based Curve Slot Waveguide for High Confinement Factor and Low Mode Effective Area along with Biosensing Application
- 5 January 2021
- Published by Springer Nature in Silicon
- Vol. 14 (3) , 859-867
Si3N4 – SiO2 Based Curve Slot Waveguide for High Confinement Factor and Low Mode Effective Area along with Biosensing Application
- 13 November 2020
- Published by Walter de Gruyter GmbH in Frequenz
- Vol. 75 (3-4) , 135-142
Non-invasive detection and discrimination of breast tumors at early stage using spiral antenna
In this paper, an Archimedean spiral antenna-based biosensor has been proposed for the early detection of breast tumor. By monitoring the variation of S11 over 1–3.5 GHz frequency range, the proposed scheme can identify the tumor location, as well as distinguish the types of tumor (benign or malignant) based on shapes and dielectric properties contrast. To validate the concept, full wave simulation using CST microwave suite are performed along with VNA based experimental measurements on breast phantoms and tumors, prepared by easily available materials like glass, petroleum jelly, mixture of water and wheat flour. The demonstrated device is able to detect the tumor of less than 1 mm in radius and positioned anywhere in 5 × 5 × 5 cm of breast fat. The proposed method is easy to use, low cost, safe, comfortable, non-invasive and non- ionizing in nature.
- 13 November 2020
- Published by Walter de Gruyter GmbH in Frequenz
- Vol. 75 (3-4) , 135-142
Non-invasive detection and discrimination of breast tumors at early stage using spiral antenna
In this paper, an Archimedean spiral antenna-based biosensor has been proposed for the early detection of breast tumor. By monitoring the variation of S11 over 1–3.5 GHz frequency range, the proposed scheme can identify the tumor location, as well as distinguish the types of tumor (benign or malignant) based on shapes and dielectric properties contrast. To validate the concept, full wave simulation using CST microwave suite are performed along with VNA based experimental measurements on breast phantoms and tumors, prepared by easily available materials like glass, petroleum jelly, mixture of water and wheat flour. The demonstrated device is able to detect the tumor of less than 1 mm in radius and positioned anywhere in 5 × 5 × 5 cm of breast fat. The proposed method is easy to use, low cost, safe, comfortable, non-invasive and non- ionizing in nature.
- 22 July 2019
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 51 (8) , 1-10
Parametric optimization of fiber to waveguide coupler using Bragg gratings
- 22 July 2019
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 51 (8) , 1-10
Parametric optimization of fiber to waveguide coupler using Bragg gratings