Serge Olszewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Serge Olszewski has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Volodymyr Lytvynenko
Kherson National Technical University
5 shared publications - Violetta Demchenko
State Institution “Kundiiev Institute of Occupational Health of the National Academy of Medical Sciences of Ukraine”, Kyiv, Ukraine
4 shared publications - Ye. Zajets
State Institution “Kundiiev Institute of Occupational Health of the National Academy of Medical Sciences of Ukraine”, Kyiv, Ukraine
4 shared publications - Iryna Lurie
Kherson National Technical University
3 shared publications - Mariia Voronenko
Kherson National Technical University
3 shared publications - Oleg Boskin
Kherson National Technical University
3 shared publications
Latest Publications
- Open Access
- 20 March 2026
- Published by Taras Shevchenko National University of Kyiv in Collection of scientific works of the Military Institute of Kyiv National Taras Shevchenko University
- No. 90,p. 17-28
COMPARATIVE ANALYSIS OF CONTACT AND CONTACTLESS METHODS FOR DETERMINING THE ELECTRICAL CONDUCTIVITY OF AQUEOUS SOLUTIONS
The purpose of this study is a comparative analysis of the direct contact measurement of the electrical conductivity of aqueous solutions and the impedance-based approach, which is considered as the first stage in the development of a contactless sensor for determining the conductivity of aqueous solutions. A two-electrode contact conductivity sensor with a cell constant K = 0.993 cm⁻¹ was used in this work. For the same sample of municipal water, the long-term drift of the direct contact channel was analyzed, and the influence of the reference resistor value on the accuracy of determining the impedance modulus of the electrolytic cell in an AC voltage divider circuit with controlled selection of the reference element was investigated. The switching of reference resistors with nominal values from 1 kΩ to 220 kΩ was performed by a CD4051 analog multiplexer controlled by an STM32G431 microcontroller, while the input and output voltages were digitized by the built-in analog-to-digital converter. It was experimentally established that the direct contact channel demonstrates a relative conductivity drift of about 12.03 % for an unchanged water sample, which is caused by polarization processes at the electrode–electrolyte interface, the formation of the electric double layer and the slow dynamics of the near-electrode layer. It is shown that even a simplified single-frequency impedance channel significantly reduces the influence of slow drift processes compared to the direct contact channel, and the smallest error of determining the impedance modulus, equal to 0.21 %, is achieved when the reference resistor is matched to the modulus of the impedance under study, which fully corresponds to the theoretical minimum of the error coefficient. Based on the obtained results, the expediency of a further transition to contactless conductivity measurement through the analysis of the full shape of the electrochemical impedance spectrum in a wide frequency range is substantiated, which will make it possible to obtain not only an integral conductivity value, but also additional informative parameters related to the concentration and mobility of ions in the solution.
- 20 March 2026
- Published by Taras Shevchenko National University of Kyiv in Collection of scientific works of the Military Institute of Kyiv National Taras Shevchenko University
- No. 90,p. 17-28
Open AccessCOMPARATIVE ANALYSIS OF CONTACT AND CONTACTLESS METHODS FOR DETERMINING THE ELECTRICAL CONDUCTIVITY OF AQUEOUS SOLUTIONS
The purpose of this study is a comparative analysis of the direct contact measurement of the electrical conductivity of aqueous solutions and the impedance-based approach, which is considered as the first stage in the development of a contactless sensor for determining the conductivity of aqueous solutions. A two-electrode contact conductivity sensor with a cell constant K = 0.993 cm⁻¹ was used in this work. For the same sample of municipal water, the long-term drift of the direct contact channel was analyzed, and the influence of the reference resistor value on the accuracy of determining the impedance modulus of the electrolytic cell in an AC voltage divider circuit with controlled selection of the reference element was investigated. The switching of reference resistors with nominal values from 1 kΩ to 220 kΩ was performed by a CD4051 analog multiplexer controlled by an STM32G431 microcontroller, while the input and output voltages were digitized by the built-in analog-to-digital converter. It was experimentally established that the direct contact channel demonstrates a relative conductivity drift of about 12.03 % for an unchanged water sample, which is caused by polarization processes at the electrode–electrolyte interface, the formation of the electric double layer and the slow dynamics of the near-electrode layer. It is shown that even a simplified single-frequency impedance channel significantly reduces the influence of slow drift processes compared to the direct contact channel, and the smallest error of determining the impedance modulus, equal to 0.21 %, is achieved when the reference resistor is matched to the modulus of the impedance under study, which fully corresponds to the theoretical minimum of the error coefficient. Based on the obtained results, the expediency of a further transition to contactless conductivity measurement through the analysis of the full shape of the electrochemical impedance spectrum in a wide frequency range is substantiated, which will make it possible to obtain not only an integral conductivity value, but also additional informative parameters related to the concentration and mobility of ions in the solution.
- 31 December 2023
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2023 (Suppl) , 347-372
Application of mutual information assessment methods for feature selection in regression models predicting percutaneous penetration of pesticides
Application of mutual information assessment methods for feature selection in regression models predicting percutaneous penetration of pesticides: ISSN 2223-6775 Ukrainian Journal of Occupational Health, Vol. 19, 2023, Supplementhttps://doi.org/10.33573/ujoh2023.05.347 Application of mutual information assessment methods for feature selection in regression models predicting percutaneous penetration
- 31 December 2023
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2023 (Suppl) , 347-372
Application of mutual information assessment methods for feature selection in regression models predicting percutaneous penetration of pesticides
Application of mutual information assessment methods for feature selection in regression models predicting percutaneous penetration of pesticides: ISSN 2223-6775 Ukrainian Journal of Occupational Health, Vol. 19, 2023, Supplementhttps://doi.org/10.33573/ujoh2023.05.347 Application of mutual information assessment methods for feature selection in regression models predicting percutaneous penetration
- 31 December 2023
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2023 (Suppl) , 343-346
Development of classical methods for pesticides identification in the realities of modern innovations
Development of classical methods for pesticides identification in the realities of modern innovations: ISSN 2223-6775 Ukrainian Journal of Occupational Health, Vol. 19, 2023, Supplementhttps://doi.org/10.33573/ujoh2023.05.343 Development of classical methods for pesticides identification in the realities of modern innovations Olszewski S. V., Demchenko V.
- 31 December 2023
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2023 (Suppl) , 343-346
Development of classical methods for pesticides identification in the realities of modern innovations
Development of classical methods for pesticides identification in the realities of modern innovations: ISSN 2223-6775 Ukrainian Journal of Occupational Health, Vol. 19, 2023, Supplementhttps://doi.org/10.33573/ujoh2023.05.343 Development of classical methods for pesticides identification in the realities of modern innovations Olszewski S. V., Demchenko V.
- Open Access
- 1 January 2021
- Published by Publishing House Helvetica (Publications) in Scientific notes of Taurida National V.I. Vernadsky University. Series: Technical Sciences
- Vol. 1 (1) , 28-32
INVESTIGATION OF THE INFLUENCE OF THE DEFECT IN THE MAGNETRON RESONATORY SYSTEM ON THE PARAMETERS OF IT’S MICROWAVE FIELD
- 1 January 2021
- Published by Publishing House Helvetica (Publications) in Scientific notes of Taurida National V.I. Vernadsky University. Series: Technical Sciences
- Vol. 1 (1) , 28-32
Open AccessINVESTIGATION OF THE INFLUENCE OF THE DEFECT IN THE MAGNETRON RESONATORY SYSTEM ON THE PARAMETERS OF IT’S MICROWAVE FIELD
- 26 July 2020
- Published by Springer Nature
- p. 567-584
Application of Inductive Bayesian Hierarchical Clustering Algorithm to Identify Brain Tumors
- 26 July 2020
- Published by Springer Nature
- p. 567-584
Application of Inductive Bayesian Hierarchical Clustering Algorithm to Identify Brain Tumors
- 24 July 2019
- Published by Springer Nature
- p. 20-34
Some Features of the Numerical Deconvolution of Mixed Molecular Spectra
- 24 July 2019
- Published by Springer Nature
- p. 20-34
Some Features of the Numerical Deconvolution of Mixed Molecular Spectra
- Open Access
- 2 January 2013
- Published by Czech Technical University in Prague - Central Library in Acta Polytechnica
- Vol. 53 (2)
Long-Lived Plasma Process, Created by Impulse Discharge in Micro-Disperse Droplet Environment
The processes of organic compound (phenol and cation-active surfactants) destruction in water solutions, which stay under the influence of plasma treatment have been investigated in different dynamic plasma-liquid systems (PLS) with discharges in droplet micro-disperse environments (DMDE). The long-lived plasma process with separate spectral properties has been observed for pulsed discharge in DMDE. The approximate computer model is being proposed for a description of this effect. According to the introduced model this long-lived process is the aggregation of correlated discharges between charged droplets.
- 2 January 2013
- Published by Czech Technical University in Prague - Central Library in Acta Polytechnica
- Vol. 53 (2)
Open AccessLong-Lived Plasma Process, Created by Impulse Discharge in Micro-Disperse Droplet Environment
The processes of organic compound (phenol and cation-active surfactants) destruction in water solutions, which stay under the influence of plasma treatment have been investigated in different dynamic plasma-liquid systems (PLS) with discharges in droplet micro-disperse environments (DMDE). The long-lived plasma process with separate spectral properties has been observed for pulsed discharge in DMDE. The approximate computer model is being proposed for a description of this effect. According to the introduced model this long-lived process is the aggregation of correlated discharges between charged droplets.
- 23 March 2011
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 44 (14)
Plasma kinetics in ethanol/water/air mixture in a ‘tornado’-type electrical discharge
This paper presents the results of a theoretical and experimental study of plasma-assisted reforming of ethanol into molecular hydrogen in a modified ‘tornado’-type electrical discharge. Numerical modelling clarifies the nature of non-thermal conversion and explains the kinetic mechanism of non-equilibrium plasma chemical transformations in the gas–liquid system and the evolution of hydrogen during the reforming as a function of discharge parameters and ethanol-to-water ratio in the mixture. We also propose a scheme of chemical reactions for plasma kinetics description. It is shown that some characteristics of the investigated reactor are at least not inferior to the characteristics of other plasma chemical reactors.
- 23 March 2011
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 44 (14)
Plasma kinetics in ethanol/water/air mixture in a ‘tornado’-type electrical discharge
This paper presents the results of a theoretical and experimental study of plasma-assisted reforming of ethanol into molecular hydrogen in a modified ‘tornado’-type electrical discharge. Numerical modelling clarifies the nature of non-thermal conversion and explains the kinetic mechanism of non-equilibrium plasma chemical transformations in the gas–liquid system and the evolution of hydrogen during the reforming as a function of discharge parameters and ethanol-to-water ratio in the mixture. We also propose a scheme of chemical reactions for plasma kinetics description. It is shown that some characteristics of the investigated reactor are at least not inferior to the characteristics of other plasma chemical reactors.