LZLei Zhao

Lei Zhao

*This is an algorithmically generated author record based on publicly available information.

Lei Zhao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Jiadong Li

    Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Sciences, Suzhou, China

    2 shared publications
  • Jin Wang

    Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215125, People's Republic of China.

    2 shared publications
  • Xinsheng Liu

    Key Laboratory of multifunctional nanomaterials and smart systems

    2 shared publications
  • Zhiqi Gu

    Key Laboratory of multifunctional nanomaterials and smart systems

    2 shared publications
  • Bin Miao

    Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Sciences, Suzhou, P. R. China

    1 shared publication
  • Bin Zeng

    The College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu, P. R. China

    1 shared publication

Latest Publications

  • An electronic enzyme-linked immunosorbent assay platform for protein analysis based on magnetic beads and AlGaN/GaN high electron mobility transistors

    by Jin Wang, Zhiqi Gu, Xinsheng Liu, Lei Zhao, Huoxiang Peng, Jiadong Li

    AlGaN/GaN high electron mobility transistor (HEMT) biosensors have attracted attention due to their high sensitivity, stability, and fast response characteristics. Some related studies have been explored but a Debye screening problem exists in physiological solutions hindering the detection of bio-macromolecules. Herein, a novel fast analytical platform for electronic enzyme-linked immunosorbent assay (e-ELISA) is proposed based on AlGaN/GaN HEMT with magnetic beads (MBs); MB-based e-ELISA decouples the modified area from the sensing surface to simplify the assay. Combining the advantages of e-ELISA and MBs, the resulting analytical platform presents a sensing capability beyond the Debye-screening limit and a novel ability to be reused. This platform offers a fast response toward prostate specific antigen (PSA) and the lowest concentration of detection is 1 fg mL−1. Compared with conventional AlGaN/GaN HEMT biosensors, it shows higher sensitivity (3.73 μA dec−1) in a linear range (1 fg mL−1 to 1 pg mL−1), which is within the constraints of emergency care applications. The platform's high sensitivity and fast repeatability endow it with great potential for early and rapid diagnosis.


  • A differential extended gate-AlGaN/GaN HEMT sensor for real-time detection of ionic pollutants

    by Lei Zhao, Xinsheng Liu, Bin Miao, Zhiqi Gu, Jin Wang, HuoXiang Peng, Jian Zhang, Bin Zeng, Jiadong Li

    In this study, we propose a differential extended gate (DEG)-AlGaN/GaN high electron mobility transistor (HEMT) sensor to detect ionic pollutants in solution. The DEG-AlGaN/GaN HEMT sensor consists of two extended gate sensing units, which combine the differential method with the extended gate structure. Ionic pollutant Fe3+ is used to test the feasibility of the device. Compared to the conventional AlGaN/GaN HEMT sensor, DEG-AlGaN/GaN HEMT sensors can effectively reduce the effect of noise factors and successfully improve the detection limit to 10 fM. At the same time, the DEG sensor shows that Fe3+ can be detected in a wide range of concentrations, varying from 10 fM to 100 μM, and it shows better linearity (R2 = 0.9955) than the conventional AlGaN/GaN HEMT sensor. These results demonstrate that the unique DEG design can overcome the drawbacks of the conventional AlGaN/GaN HEMT sensor, and significantly improve the overall performance of the AlGaN/GaN HEMT sensor. As a result, this novel sensor has the potential to be a real-time and high-performance test tool for environmental monitoring.