Jaime de la Peña Llerandi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jaime de la Peña Llerandi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. Huertas
1 shared publication- Carlos Sancho
Spanish Natl Distance Educ Univ, Dept Elect Elect & Control Engn, Madrid 28040, Spain
1 shared publication J.A. Cobos
1 shared publicationJ.A. Oliver
1 shared publicationJosé Carpio Ibáñez
Dpto. Ingeniería Eléctrica, Electrónica, Control, Telemática y Química Aplicada a la Ingeniería, Universidad Nacional de Educación a Distancia (UNED), E.T.S. de Ingenieros Industriales, cl/Juan del Rosal, 12, 28040 Madrid, Spain
1 shared publicationL.A. Flores
1 shared publication
Latest Publications
- Open Access
Continuous Battery Health Diagnosis by On-Line Internal Resistance Measuring
Energy storage in an uninterruptible power supply (UPS) is one of the most frequent applications of batteries. This can be found in hospitals, communication centers, public centers, ships, trains, etc. Most frequent industrial methods for battery state-of health estimation require a technician to move to the battery’s location and, in some cases, require the use of heavy equipment and disconnection of the battery from the UPS. For example, in railway applications, trains must stop at the maintenance depot producing significant total costs. This article proposes a new method to assess a battery’s health by measuring the battery’s internal resistance, based on the measurement of its voltage ripple in response to the current ripple imposed by the charger which in most UPS applications is permanently connected to the battery. Unlike most traditional methods, this system makes it possible a continuous on-line and on-board monitoring, and, therefore, it eases condition-based maintenance (CBM). To verify its viability, a low cost measuring prototype has been built and measurements in a railway battery with its charger have been carried out.
Open AccessContinuous Battery Health Diagnosis by On-Line Internal Resistance Measuring
Energy storage in an uninterruptible power supply (UPS) is one of the most frequent applications of batteries. This can be found in hospitals, communication centers, public centers, ships, trains, etc. Most frequent industrial methods for battery state-of health estimation require a technician to move to the battery’s location and, in some cases, require the use of heavy equipment and disconnection of the battery from the UPS. For example, in railway applications, trains must stop at the maintenance depot producing significant total costs. This article proposes a new method to assess a battery’s health by measuring the battery’s internal resistance, based on the measurement of its voltage ripple in response to the current ripple imposed by the charger which in most UPS applications is permanently connected to the battery. Unlike most traditional methods, this system makes it possible a continuous on-line and on-board monitoring, and, therefore, it eases condition-based maintenance (CBM). To verify its viability, a low cost measuring prototype has been built and measurements in a railway battery with its charger have been carried out.
- 4 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1881-1886
Bi-directional DC/DC Converter for Hybrid Vehicles
- 4 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1881-1886
Bi-directional DC/DC Converter for Hybrid Vehicles
- 25 June 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1202-1207
Wide input range module for rectified ac power distribution demonstrator for telecommunication system
This paper shows the results about an on-board power converter developed for a rectified AC power distribution demonstrator for a switching exchange. The nominal bus voltage of this architecture is rectified 220 V/sub AC/ three-phase voltage. This 50 W module has to be compatible with the current 48 V architecture, therefore the converter has to work with very wide input voltage range from 36 V to 380 V and with the same footprint that the current 48 V module. A two-stage topology was chosen and the topologies used were a buck and a forward converter. To maintain the footprint the height has be increased. The overall efficiency at full load was higher than 80% and it was successfully integrated in system.
- 25 June 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1202-1207
Wide input range module for rectified ac power distribution demonstrator for telecommunication system
This paper shows the results about an on-board power converter developed for a rectified AC power distribution demonstrator for a switching exchange. The nominal bus voltage of this architecture is rectified 220 V/sub AC/ three-phase voltage. This 50 W module has to be compatible with the current 48 V architecture, therefore the converter has to work with very wide input voltage range from 36 V to 380 V and with the same footprint that the current 48 V module. A two-stage topology was chosen and the topologies used were a buck and a forward converter. To maintain the footprint the height has be increased. The overall efficiency at full load was higher than 80% and it was successfully integrated in system.