Haydee Olinca Hernández
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Haydee Olinca Hernández has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
- Adán Guerrero
Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos, México
6 shared publications - Christopher D. Wood
Universidad Nacional Autónoma de México
5 shared publications - David Torres Hernández
Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México
3 shared publications - Esley Torres-García
Universidad de la República
3 shared publications - Jose Luis Martinez
Departamento de Genética del Desarrollo y Fisiología Molecular, Instituto de Biotecnología, Universidad Nacional Autónoma de México
3 shared publications - Juan Manuel Rendon-Mancha
Centro de Investigación en Ciencias, Instituto de Investigación en Ciencias Básicas y Aplicadas, Universidad Autónoma del Estado de Morelos
3 shared publications
Latest Publications
- Open Access
- 13 October 2026
- Published by Wiley in Journal of Microscopy
- Vol. 304 (2) , 176-188
Reviewing reproducibility and replicability in ‘Deconstructing gastrulation at single‐cell resolution’ by Stern et al. (2022)
Quantitative analysis of embryonic morphogenesis often requires handling terabyte‐scale 4D microscopy datasets, posing major computational and methodological challenges. Such analyses involve complex workflows for image restoration, segmentation, and tracking of thousands of cells in 3D, sometimes assembled from multiple generic tools and custom scripts. In their study ‘Deconstructing gastrulation at single‐cell resolution ,’ the authors present an integrated computational framework for cell segmentation, tracking and modelling of cell–cell interactions during Drosophila gastrulation. Their approach combines both generic tools such as ilastik, FIJI, Cellpose, MATLAB code and tools such as ImSAnE to reconstruct whole‐embryo, single‐cell morphogenetic atlas with unprecedented detail. While the methodology is transparent and well‐documented, its implementation relies on multiple software environments and some non–open‐source components, limiting full reproducibility and generalisability. Nevertheless, their ‘computational framework’ exemplifies rigorous data sharing, clear documentation, and methodological transparency aligned with several community guidelines for reproducible image analysis. We discuss this work in the context of reproducibility, replicability, generalisability, transparency, validity, and robustness, emphasising how emerging open‐source and popular solutions could improve accessibility and replicability of similar large‐scale bioimage analysis workflows in developmental biology.
- 13 October 2026
- Published by Wiley in Journal of Microscopy
- Vol. 304 (2) , 176-188
Open AccessReviewing reproducibility and replicability in ‘Deconstructing gastrulation at single‐cell resolution’ by Stern et al. (2022)
Quantitative analysis of embryonic morphogenesis often requires handling terabyte‐scale 4D microscopy datasets, posing major computational and methodological challenges. Such analyses involve complex workflows for image restoration, segmentation, and tracking of thousands of cells in 3D, sometimes assembled from multiple generic tools and custom scripts. In their study ‘Deconstructing gastrulation at single‐cell resolution ,’ the authors present an integrated computational framework for cell segmentation, tracking and modelling of cell–cell interactions during Drosophila gastrulation. Their approach combines both generic tools such as ilastik, FIJI, Cellpose, MATLAB code and tools such as ImSAnE to reconstruct whole‐embryo, single‐cell morphogenetic atlas with unprecedented detail. While the methodology is transparent and well‐documented, its implementation relies on multiple software environments and some non–open‐source components, limiting full reproducibility and generalisability. Nevertheless, their ‘computational framework’ exemplifies rigorous data sharing, clear documentation, and methodological transparency aligned with several community guidelines for reproducible image analysis. We discuss this work in the context of reproducibility, replicability, generalisability, transparency, validity, and robustness, emphasising how emerging open‐source and popular solutions could improve accessibility and replicability of similar large‐scale bioimage analysis workflows in developmental biology.
- Open Access
PSF-Driven Spatio-Temporal Blending in Fluorescence Lifetime Imaging Microscopy and Its Mitigation via Mean-Shift Super-Resolution-Based Masking
Fluorescence Lifetime Imaging Microscopy (FLIM) enables quantitative mapping of molecular environments in living systems with high biochemical specificity. However, spatial overlap dictated by the diffraction-limited point spread function (PSF) causes a mixing of temporal signals: photons from neighboring emitters collected within the same pixel yield composite decay profiles, generating apparent intermediate lifetimes that can be mistaken for variations in the local molecular environment. We introduce a workflow that applies Mean-Shift Super-Resolution (MSSR) to raw intensity data to generate intensity-derived spatial masks prior to phasor-based lifetime analysis. The method is computationally efficient and preserves decay kinetics because it operates on intensity-derived spatial information rather than modifying temporal data. In U2OS cells labeled with spectrally-overlapping fluorophores, phasor analysis reveals an intermediate lifetime population localized at PSF-overlap interfaces, consistent with optical mixing rather than intrinsic lifetime heterogeneity. MSSR-derived masking suppressed this mixed population while preserving stable phasor cluster centers – i.e . the distribution of similar phasor coordinates in the phasor plane– for each fluorophore. Simulations of strictly monoexponential fluorescence decay emitters further show that blended lifetime decay profiles are present at separations up to 4σ and becomes maximal near ∼1.6σ, indicating that conventional spatial resolution criteria can underestimate lifetime cross-talk. Application of this workflow to three-component FLIM showed also a reduced overlap of pixel distributions in phasor plots while maintaining distinct lifetime signatures. Overall, MSSR-based spatial refinement provides an accessible strategy to improve the spatial resolution while maintaining accuracy of FLIM measurements.
Open AccessPSF-Driven Spatio-Temporal Blending in Fluorescence Lifetime Imaging Microscopy and Its Mitigation via Mean-Shift Super-Resolution-Based Masking
Fluorescence Lifetime Imaging Microscopy (FLIM) enables quantitative mapping of molecular environments in living systems with high biochemical specificity. However, spatial overlap dictated by the diffraction-limited point spread function (PSF) causes a mixing of temporal signals: photons from neighboring emitters collected within the same pixel yield composite decay profiles, generating apparent intermediate lifetimes that can be mistaken for variations in the local molecular environment. We introduce a workflow that applies Mean-Shift Super-Resolution (MSSR) to raw intensity data to generate intensity-derived spatial masks prior to phasor-based lifetime analysis. The method is computationally efficient and preserves decay kinetics because it operates on intensity-derived spatial information rather than modifying temporal data. In U2OS cells labeled with spectrally-overlapping fluorophores, phasor analysis reveals an intermediate lifetime population localized at PSF-overlap interfaces, consistent with optical mixing rather than intrinsic lifetime heterogeneity. MSSR-derived masking suppressed this mixed population while preserving stable phasor cluster centers – i.e . the distribution of similar phasor coordinates in the phasor plane– for each fluorophore. Simulations of strictly monoexponential fluorescence decay emitters further show that blended lifetime decay profiles are present at separations up to 4σ and becomes maximal near ∼1.6σ, indicating that conventional spatial resolution criteria can underestimate lifetime cross-talk. Application of this workflow to three-component FLIM showed also a reduced overlap of pixel distributions in phasor plots while maintaining distinct lifetime signatures. Overall, MSSR-based spatial refinement provides an accessible strategy to improve the spatial resolution while maintaining accuracy of FLIM measurements.
- Open Access
- 1 January 2025
- Published by ScienceOpen
- p. e072
STEM Education to Foster Mexican Communities: A Start-Up Approach
Low performance in science among Mexican students, as reported in the OECD’s 2022 PISA study, highlights systemic challenges in the country’s education system. Barriers such as outdated curricula, underprepared teachers, and limited access to scientific equipment contribute to these results. Addressing these gaps, Educaciencia, a start-up founded in 2021 by students and staff from Mexico’s National Laboratory for Advanced Microscopy, has developed a range of affordable, 3D-printed, modular microscopes designed for primary to high school students. These microscopes are user-friendly, easy to maintain, and tailored to enhance STEM education. Beyond providing low-cost equipment, Educaciencia emphasizes teacher training by offering classroom-ready curricula and experimental practices. By bridging the gap between students and real-world microscopy, the initiative empowers educators to integrate hands-on scientific tools effectively. Collaborations with the Mexican Bioimaging Community, including workshops supported by the Chan Zuckerberg Initiative, have enabled outreach to underserved communities, particularly in Mexico City and Cuetzalan, Puebla. Educaciencia has organized more than 25 outreach events in schools and public spaces, engaging diverse audiences, including children, young people, and adults, in the world of STEM. These activities are carefully designed to combine optics, microscopy, and foundational STEM knowledge in interactive and hands-on ways. Participants explore sample preparation techniques, play with laser chess to understand light and optics, and use our 3D-printed microscopes to observe prepared specimens such as vegetable and animal cells. Additionally, puzzles and games centered around light microscopy encourage participants to connect biological concepts with tangible experiences. These events aim to spark curiosity and inspire audiences of all ages to explore the possibilities of science and technology, creating a bridge to STEM education through accessible, innovative approaches.
- 1 January 2025
- Published by ScienceOpen
- p. e072
Open AccessSTEM Education to Foster Mexican Communities: A Start-Up Approach
Low performance in science among Mexican students, as reported in the OECD’s 2022 PISA study, highlights systemic challenges in the country’s education system. Barriers such as outdated curricula, underprepared teachers, and limited access to scientific equipment contribute to these results. Addressing these gaps, Educaciencia, a start-up founded in 2021 by students and staff from Mexico’s National Laboratory for Advanced Microscopy, has developed a range of affordable, 3D-printed, modular microscopes designed for primary to high school students. These microscopes are user-friendly, easy to maintain, and tailored to enhance STEM education. Beyond providing low-cost equipment, Educaciencia emphasizes teacher training by offering classroom-ready curricula and experimental practices. By bridging the gap between students and real-world microscopy, the initiative empowers educators to integrate hands-on scientific tools effectively. Collaborations with the Mexican Bioimaging Community, including workshops supported by the Chan Zuckerberg Initiative, have enabled outreach to underserved communities, particularly in Mexico City and Cuetzalan, Puebla. Educaciencia has organized more than 25 outreach events in schools and public spaces, engaging diverse audiences, including children, young people, and adults, in the world of STEM. These activities are carefully designed to combine optics, microscopy, and foundational STEM knowledge in interactive and hands-on ways. Participants explore sample preparation techniques, play with laser chess to understand light and optics, and use our 3D-printed microscopes to observe prepared specimens such as vegetable and animal cells. Additionally, puzzles and games centered around light microscopy encourage participants to connect biological concepts with tangible experiences. These events aim to spark curiosity and inspire audiences of all ages to explore the possibilities of science and technology, creating a bridge to STEM education through accessible, innovative approaches.
- Open Access
- 15 May 2024
- Published by Wiley in Journal of Microscopy
- Vol. 294 (3) , 420-439
Building momentum through networks: Bioimaging across the Americas
In September 2023, the two largest bioimaging networks in the Americas, Latin America Bioimaging (LABI) and BioImaging North America (BINA), came together during a 1‐week meeting in Mexico. This meeting provided opportunities for participants to interact closely with decision‐makers from imaging core facilities across the Americas. The meeting was held in a hybrid format and attended in‐person by imaging scientists from across the Americas, including Canada, the United States, Mexico, Colombia, Peru, Argentina, Chile, Brazil and Uruguay. The aims of the meeting were to discuss progress achieved over the past year, to foster networking and collaborative efforts among members of both communities, to bring together key members of the international imaging community to promote the exchange of experience and expertise, to engage with industry partners, and to establish future directions within each individual network, as well as common goals. This meeting report summarises the discussions exchanged, the achievements shared, and the goals set during the LABIxBINA2023: Bioimaging across the Americas meeting.
- 15 May 2024
- Published by Wiley in Journal of Microscopy
- Vol. 294 (3) , 420-439
Open AccessBuilding momentum through networks: Bioimaging across the Americas
In September 2023, the two largest bioimaging networks in the Americas, Latin America Bioimaging (LABI) and BioImaging North America (BINA), came together during a 1‐week meeting in Mexico. This meeting provided opportunities for participants to interact closely with decision‐makers from imaging core facilities across the Americas. The meeting was held in a hybrid format and attended in‐person by imaging scientists from across the Americas, including Canada, the United States, Mexico, Colombia, Peru, Argentina, Chile, Brazil and Uruguay. The aims of the meeting were to discuss progress achieved over the past year, to foster networking and collaborative efforts among members of both communities, to bring together key members of the international imaging community to promote the exchange of experience and expertise, to engage with industry partners, and to establish future directions within each individual network, as well as common goals. This meeting report summarises the discussions exchanged, the achievements shared, and the goals set during the LABIxBINA2023: Bioimaging across the Americas meeting.
- Open Access
Feature-Based 3D+t Descriptors of Hyperactivated Human Sperm Beat Patterns
The flagellar movement of the mammalian sperm is essential for male fertility as it enables this cell to reach and fertilize an egg. In the female reproductive tract, human spermatozoa undergo a process called capacitation which promotes changes in their motility. Only those spermatozoa that change to hyperactivated (HA) motility are capable of fertilizing the egg; this type of motility is characterized by asymmetric flagellar bends of greater amplitude and lower frequency. Historically, clinical fertilization studies have used two-dimensional analysis to classify sperm motility, although, sperm motility is three-dimensional (3D). Recent studies have described several 3D beating features of sperm flagella, including curvature, torsion, and asymmetries. However, the 3D motility pattern of hyperactivated spermatozoa has not yet been characterized. One of the main difficulties in classifying these patterns in 3D is the lack of a ground-truth reference, as it can be difficult to visually assess differences in flagellar beat patterns. Additionally, only about 10 − 20% of sperm that have been induced to capacitate are truly capacitated (i.e., hyperactivated). In this work, we used an image acquisition system that can acquire, segment, and track sperm flagella in 3D+t. We developed a feature-based vector that describes the spatio-temporal flagellar sperm motility patterns by an envelope of ellipses. Our results demonstrate that the proposed descriptors can effectively be used to distinguish between hyperactivated and nonhyperactivated spermatozoa, providing a tool to characterize the 3D sperm flagellar beat motility patterns without prior training or supervision. We demonstrated the effectiveness of the descriptors by applying them to a dataset of human sperm cells and showing that they can accurately classify the motility patterns of the sperm cells. This work is potentially useful for assessing male fertility or for diagnosing.
Open AccessFeature-Based 3D+t Descriptors of Hyperactivated Human Sperm Beat Patterns
The flagellar movement of the mammalian sperm is essential for male fertility as it enables this cell to reach and fertilize an egg. In the female reproductive tract, human spermatozoa undergo a process called capacitation which promotes changes in their motility. Only those spermatozoa that change to hyperactivated (HA) motility are capable of fertilizing the egg; this type of motility is characterized by asymmetric flagellar bends of greater amplitude and lower frequency. Historically, clinical fertilization studies have used two-dimensional analysis to classify sperm motility, although, sperm motility is three-dimensional (3D). Recent studies have described several 3D beating features of sperm flagella, including curvature, torsion, and asymmetries. However, the 3D motility pattern of hyperactivated spermatozoa has not yet been characterized. One of the main difficulties in classifying these patterns in 3D is the lack of a ground-truth reference, as it can be difficult to visually assess differences in flagellar beat patterns. Additionally, only about 10 − 20% of sperm that have been induced to capacitate are truly capacitated (i.e., hyperactivated). In this work, we used an image acquisition system that can acquire, segment, and track sperm flagella in 3D+t. We developed a feature-based vector that describes the spatio-temporal flagellar sperm motility patterns by an envelope of ellipses. Our results demonstrate that the proposed descriptors can effectively be used to distinguish between hyperactivated and nonhyperactivated spermatozoa, providing a tool to characterize the 3D sperm flagellar beat motility patterns without prior training or supervision. We demonstrated the effectiveness of the descriptors by applying them to a dataset of human sperm cells and showing that they can accurately classify the motility patterns of the sperm cells. This work is potentially useful for assessing male fertility or for diagnosing.
- Open Access
- 2 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-22
Extending resolution within a single imaging frame
The resolution of fluorescence microscopy images is limited by the physical properties of light. In the last decade, numerous super-resolution microscopy (SRM) approaches have been proposed to deal with such hindrance. Here we present Mean-Shift Super Resolution (MSSR), a new SRM algorithm based on the Mean Shift theory, which extends spatial resolution of single fluorescence images beyond the diffraction limit of light. MSSR works on low and high fluorophore densities, is not limited by the architecture of the optical setup and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image stacks, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other SRM approaches. Along with its wide accessibility, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.
- 2 December 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-22
Open AccessExtending resolution within a single imaging frame
The resolution of fluorescence microscopy images is limited by the physical properties of light. In the last decade, numerous super-resolution microscopy (SRM) approaches have been proposed to deal with such hindrance. Here we present Mean-Shift Super Resolution (MSSR), a new SRM algorithm based on the Mean Shift theory, which extends spatial resolution of single fluorescence images beyond the diffraction limit of light. MSSR works on low and high fluorophore densities, is not limited by the architecture of the optical setup and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image stacks, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other SRM approaches. Along with its wide accessibility, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.
- Open Access
Nanoscopic resolution within a single imaging frame
Mean-Shift Super Resolution (MSSR) is a principle based on the Mean Shift theory that extends spatial resolution in fluorescence images, beyond the diffraction limit. MSSR works on low- and high-density fluorophore images, is not limited by the architecture of the detector (EM-CCD, sCMOS, or photomultiplier-based laser scanning systems) and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image series, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other analytical super resolution image approaches. Altogether, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.
Open AccessNanoscopic resolution within a single imaging frame
Mean-Shift Super Resolution (MSSR) is a principle based on the Mean Shift theory that extends spatial resolution in fluorescence images, beyond the diffraction limit. MSSR works on low- and high-density fluorophore images, is not limited by the architecture of the detector (EM-CCD, sCMOS, or photomultiplier-based laser scanning systems) and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image series, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other analytical super resolution image approaches. Altogether, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.
- Open Access
- 25 July 2019
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 8
Nanoscale organization of rotavirus replication machineries
Rotavirus genome replication and assembly take place in cytoplasmic electron dense inclusions termed viroplasms (VPs). Previous conventional optical microscopy studies observing the intracellular distribution of rotavirus proteins and their organization in VPs have lacked molecular-scale spatial resolution, due to inherent spatial resolution constraints. In this work we employed super-resolution microscopy to reveal the nanometric-scale organization of VPs formed during rotavirus infection, and quantitatively describe the structural organization of seven viral proteins within and around the VPs. The observed viral components are spatially organized as five concentric layers, in which NSP5 localizes at the center of the VPs, surrounded by a layer of NSP2 and NSP4 proteins, followed by an intermediate zone comprised of the VP1, VP2, VP6. In the outermost zone, we observed a ring of VP4 and finally a layer of VP7. These findings show that rotavirus VPs are highly organized organelles.
- 25 July 2019
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 8
Open AccessNanoscale organization of rotavirus replication machineries
Rotavirus genome replication and assembly take place in cytoplasmic electron dense inclusions termed viroplasms (VPs). Previous conventional optical microscopy studies observing the intracellular distribution of rotavirus proteins and their organization in VPs have lacked molecular-scale spatial resolution, due to inherent spatial resolution constraints. In this work we employed super-resolution microscopy to reveal the nanometric-scale organization of VPs formed during rotavirus infection, and quantitatively describe the structural organization of seven viral proteins within and around the VPs. The observed viral components are spatially organized as five concentric layers, in which NSP5 localizes at the center of the VPs, surrounded by a layer of NSP2 and NSP4 proteins, followed by an intermediate zone comprised of the VP1, VP2, VP6. In the outermost zone, we observed a ring of VP4 and finally a layer of VP7. These findings show that rotavirus VPs are highly organized organelles.
- Open Access
Nanoscale organization of rotavirus replication machineries
Rotavirus genome replication and assembly take place in cytoplasmic electron dense inclusions termed viro-plasms (VPs). Previous conventional optical microscopy studies observing the intracellular distribution of rotavirus proteins and their organization in VPs have lacked molecular-scale spatial resolution, due to inherent spatial resolution constraints. In this work we employed super-resolution microscopy to reveal the nanometric-scale organization of VPs formed during rotavirus infection, and quantitatively describe the structural organization of seven viral proteins and viral dsRNA within and around the VPs. The observed viral components are spatially organized as 6 concentric layers, in which NSP5 localizes at the center of the VPs, surrounded by a layer of NSP2 and NSP4 proteins, followed by an intermediate zone comprised of the VP1, VP2, VP6 proteins and the dsRNA. In the outermost zone, we observed a ring of VP4 and finally a layer of VP7. These findings show that rotavirus VPs are highly organized organelles.
Open AccessNanoscale organization of rotavirus replication machineries
Rotavirus genome replication and assembly take place in cytoplasmic electron dense inclusions termed viro-plasms (VPs). Previous conventional optical microscopy studies observing the intracellular distribution of rotavirus proteins and their organization in VPs have lacked molecular-scale spatial resolution, due to inherent spatial resolution constraints. In this work we employed super-resolution microscopy to reveal the nanometric-scale organization of VPs formed during rotavirus infection, and quantitatively describe the structural organization of seven viral proteins and viral dsRNA within and around the VPs. The observed viral components are spatially organized as 6 concentric layers, in which NSP5 localizes at the center of the VPs, surrounded by a layer of NSP2 and NSP4 proteins, followed by an intermediate zone comprised of the VP1, VP2, VP6 proteins and the dsRNA. In the outermost zone, we observed a ring of VP4 and finally a layer of VP7. These findings show that rotavirus VPs are highly organized organelles.