Brian Vick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brian Vick has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Elaine P. Scott
College of Engineering, University of Washington, Box 352180, Seattle, Washington 98195-2180;
2 shared publications - Abdusalam Al-Khwaji1 shared publication
Abdusalam Alkhwaji
Virginia Tech
1 shared publication- Hamid M. Ghasemi
School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, Tehran, Iran
1 shared publication J. Robert Mahan
Mechanical Engineering Department, Virginia Tech, Blacksburg, USA
1 shared publication- J. Robert Mahan
Virginia Polytechnic Institute and State University
1 shared publication
Latest Publications
- 11 April 2023
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 145 (8) , 1-23
Second-Law Considerations in Monte Carlo Ray-Trace and Discrete Green’s Function Analysis of Coupled Radiation and Conduction Heat Transfer
A generic Monte Carlo ray-trace (MCRT) engine for computing radiation distribution factors (RDFs), working in tandem with an efficient finite volume formulation based on discrete Green’s functions (DGFs), has been used to solve a massive (2636 nodes) coupled radiation/conduction problem. Distribution factors computed using the MCRT method are known to produce unconditionally stable solutions to pure radiation problems even though the RDFs themselves do not conform exactly to the reciprocity principle. However, when these same RFDs are introduced into time-dependent finite volume conduction formulations based on DGFs, the resulting model is found to be fundamentally unstable due to inherent violations of the second law of thermodynamics. A novel approach to addressing this instability is presented and demonstrated for the case of a telescope typical of those employed to monitor the planetary energy budget from low Earth orbit.
- 11 April 2023
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 145 (8) , 1-23
Second-Law Considerations in Monte Carlo Ray-Trace and Discrete Green’s Function Analysis of Coupled Radiation and Conduction Heat Transfer
A generic Monte Carlo ray-trace (MCRT) engine for computing radiation distribution factors (RDFs), working in tandem with an efficient finite volume formulation based on discrete Green’s functions (DGFs), has been used to solve a massive (2636 nodes) coupled radiation/conduction problem. Distribution factors computed using the MCRT method are known to produce unconditionally stable solutions to pure radiation problems even though the RDFs themselves do not conform exactly to the reciprocity principle. However, when these same RFDs are introduced into time-dependent finite volume conduction formulations based on DGFs, the resulting model is found to be fundamentally unstable due to inherent violations of the second law of thermodynamics. A novel approach to addressing this instability is presented and demonstrated for the case of a telescope typical of those employed to monitor the planetary energy budget from low Earth orbit.
- 22 July 2019
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 40 (8) , 1-21
Estimation of Model Parameters for Earth Radiation Budget Instruments
- 22 July 2019
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 40 (8) , 1-21
Estimation of Model Parameters for Earth Radiation Budget Instruments
- 3 July 2013
- Published by ASME International in Journal of Medical Devices
- Vol. 7 (3) , 031003
Modeling and Estimating Simulated Burn Depth Using the Perfusion and Thermal Resistance Probe
A new thermal perfusion probe operates by imposing a thermal event on the tissue surface and directly measuring the temperature and heat flux response of the tissue with a small sensor. The thermal event is created by convectively cooling the surface with a small group of impinging jets using room temperature air. The hypothesis of this research is that this sensor can be used to provide practical burn characterization of depth and severity by determining the thickness of nonperfused tissue. To demonstrate this capability the measurement system was tested with a phantom tissue that simulates the blood perfusion of tissue. Different thicknesses of plastic were used at the surface to mimic layers of dead tissue. A mathematical model developed by Alkhwaji et al. (2012, “New Mathematical Model to Estimate Tissue Blood Perfusion, Thermal Contact Resistance and Core Temperature,” ASME J. Biomech. Eng., 134, p. 081004) is used to determine the effective values of blood perfusion, core temperature, and thermal resistance from the thermal measurements. The analytical solutions of the Pennes bioheat equation using the Green's function method is coupled with an efficient parameter estimation procedure to minimize the error between measured and analytical heat flux. Seven different thicknesses of plastic were used along with three different flow rates of perfusate to simulate burned skin of the phantom perfusion system. The resulting values of thermal resistance are a combination of the plastic resistance and thermal contact resistance between the sensor and plastic surface. Even with the uncertainty of sensor placement on the surface, the complete set of thermal resistance measurements correlate well with the layer thickness. The values are also nearly independent of the flow rate of the perfusate, which shows that the parameter estimation can successfully separate these two parameters. These results with simulated burns show the value of this minimally invasive technique to measure the thickness of nonperfused layers. This will encourage further work with this method on actual tissue burns.
- 3 July 2013
- Published by ASME International in Journal of Medical Devices
- Vol. 7 (3) , 031003
Modeling and Estimating Simulated Burn Depth Using the Perfusion and Thermal Resistance Probe
A new thermal perfusion probe operates by imposing a thermal event on the tissue surface and directly measuring the temperature and heat flux response of the tissue with a small sensor. The thermal event is created by convectively cooling the surface with a small group of impinging jets using room temperature air. The hypothesis of this research is that this sensor can be used to provide practical burn characterization of depth and severity by determining the thickness of nonperfused tissue. To demonstrate this capability the measurement system was tested with a phantom tissue that simulates the blood perfusion of tissue. Different thicknesses of plastic were used at the surface to mimic layers of dead tissue. A mathematical model developed by Alkhwaji et al. (2012, “New Mathematical Model to Estimate Tissue Blood Perfusion, Thermal Contact Resistance and Core Temperature,” ASME J. Biomech. Eng., 134, p. 081004) is used to determine the effective values of blood perfusion, core temperature, and thermal resistance from the thermal measurements. The analytical solutions of the Pennes bioheat equation using the Green's function method is coupled with an efficient parameter estimation procedure to minimize the error between measured and analytical heat flux. Seven different thicknesses of plastic were used along with three different flow rates of perfusate to simulate burned skin of the phantom perfusion system. The resulting values of thermal resistance are a combination of the plastic resistance and thermal contact resistance between the sensor and plastic surface. Even with the uncertainty of sensor placement on the surface, the complete set of thermal resistance measurements correlate well with the layer thickness. The values are also nearly independent of the flow rate of the perfusate, which shows that the parameter estimation can successfully separate these two parameters. These results with simulated burns show the value of this minimally invasive technique to measure the thickness of nonperfused layers. This will encourage further work with this method on actual tissue burns.
- 1 January 2012
- Vol. 48, 12-9
Estimating burn depth from thermal measurements.
A new thermal perfusion probe operates by imposing a thermal event on the tissue surface and directly measuring the temperature and heat flux response of the tissue with a small sensor. The thermal event is created by convectively cooling the surface with a small group of impinging jets using room temperature air. The hypothesis of this research is that this sensor can be used to provide practical burn characterization of depth and severity by determining the thickness of non-perfused tissue. The measurement system was tested with a phantom tissue that simulates the blood perfusion of tissue. Different thicknesses of plastic were used at the surface to mimic layers of dead tissue. The sensor uses a parameter estimation procedure with analytical solutions of the Pennes bio-heat equation to determine effective values of blood perfusion, core temperature, and thermal contact resistance. Twelve different thicknesses of plastic were used along with three different flow rates of perfusate to simulate burned skin in the phantom perfusion system. The resulting values of thermal contact resistance for the complete set of measurements correlate well with the layer thickness. The values are also nearly independent of the flow rate of the perfusate, which shows that the parameter estimation can successfully separate these parameters. These results with simulated burns show the value of this minimally invasive technique to predict the burn depth in tissue.
- 1 January 2012
- Vol. 48, 12-9
Estimating burn depth from thermal measurements.
A new thermal perfusion probe operates by imposing a thermal event on the tissue surface and directly measuring the temperature and heat flux response of the tissue with a small sensor. The thermal event is created by convectively cooling the surface with a small group of impinging jets using room temperature air. The hypothesis of this research is that this sensor can be used to provide practical burn characterization of depth and severity by determining the thickness of non-perfused tissue. The measurement system was tested with a phantom tissue that simulates the blood perfusion of tissue. Different thicknesses of plastic were used at the surface to mimic layers of dead tissue. The sensor uses a parameter estimation procedure with analytical solutions of the Pennes bio-heat equation to determine effective values of blood perfusion, core temperature, and thermal contact resistance. Twelve different thicknesses of plastic were used along with three different flow rates of perfusate to simulate burned skin in the phantom perfusion system. The resulting values of thermal contact resistance for the complete set of measurements correlate well with the layer thickness. The values are also nearly independent of the flow rate of the perfusate, which shows that the parameter estimation can successfully separate these parameters. These results with simulated burns show the value of this minimally invasive technique to predict the burn depth in tissue.
- 1 July 2011
- Published by ASME International in Journal of Tribology
- Vol. 133 (3) , 031407
Estimation of the Real Area of Contact in Sliding Systems Using Thermal Measurements
The objectives of this paper are to develop a means to estimate the real area of contact in sliding systems using thermal measurements and to provide experimental design guidance for optimal sensor locations. The methods used are a modified cellular automata technique for the direct model and a Levenberg–Marquardt parameter estimation technique to stabilize inverse solutions. The modified cellular automata technique enables each piece of physics to be solved independently over a short time step, thus reducing a complicated model to a sequence of simpler problems. Overall, the method proved successful. The major results indicate that appropriately selected measurement locations can determine the contact distribution accurately. The best measurement location is found to be just downstream of the nominal contact zone in the moving body. This is significant since direct access to the contact zone is usually impossible. Results show that it is best to locate a sensor in the moving body. However, placing the sensor in the static body can also provide a reasonable image of the contact distribution. This is useful because the static body is easier to instrument than a moving body. Finally, the estimation method worked well for the most complex model utilized, even in a suboptimal measurement location
- 1 July 2011
- Published by ASME International in Journal of Tribology
- Vol. 133 (3) , 031407
Estimation of the Real Area of Contact in Sliding Systems Using Thermal Measurements
The objectives of this paper are to develop a means to estimate the real area of contact in sliding systems using thermal measurements and to provide experimental design guidance for optimal sensor locations. The methods used are a modified cellular automata technique for the direct model and a Levenberg–Marquardt parameter estimation technique to stabilize inverse solutions. The modified cellular automata technique enables each piece of physics to be solved independently over a short time step, thus reducing a complicated model to a sequence of simpler problems. Overall, the method proved successful. The major results indicate that appropriately selected measurement locations can determine the contact distribution accurately. The best measurement location is found to be just downstream of the nominal contact zone in the moving body. This is significant since direct access to the contact zone is usually impossible. Results show that it is best to locate a sensor in the moving body. However, placing the sensor in the static body can also provide a reasonable image of the contact distribution. This is useful because the static body is easier to instrument than a moving body. Finally, the estimation method worked well for the most complex model utilized, even in a suboptimal measurement location
- 1 July 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (7) , 074518
The Question of Thermal Waves in Heterogeneous and Biological Materials
In the 1990s, there were two experimental studies that sparked a renewed interest in thermal wave behavior at the macroscale level. Both reported thermal relaxation times of 10 s or higher. However, no further experimental evidence of this behavior has been reported. Due to the extreme significance of these findings, the objectives of this study were to try to reproduce these earlier studies and offer an explanation for the outcome. These two previous studies, one using heterogeneous materials and one using bologna, were repeated following the experimental protocol provided in the studies as closely and as practically as possible. In both cases, the temperature response to a specified boundary condition was recorded. The results from the first set of experiments suggested that the thermal relaxation times presented in the previous study were actually the thermal lag expected from applying Fourier’s law, taking into account the uncertainty of the temperature sensor. In the second set of experiments, unlike the distinct jumps in temperature found previously, no indication of wave behavior was found. Here, the explanation for the previous results was more difficult to ascertain. Possible explanations include problems with either the experimental protocol or the temperature sensors used.
- 1 July 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (7) , 074518
The Question of Thermal Waves in Heterogeneous and Biological Materials
In the 1990s, there were two experimental studies that sparked a renewed interest in thermal wave behavior at the macroscale level. Both reported thermal relaxation times of 10 s or higher. However, no further experimental evidence of this behavior has been reported. Due to the extreme significance of these findings, the objectives of this study were to try to reproduce these earlier studies and offer an explanation for the outcome. These two previous studies, one using heterogeneous materials and one using bologna, were repeated following the experimental protocol provided in the studies as closely and as practically as possible. In both cases, the temperature response to a specified boundary condition was recorded. The results from the first set of experiments suggested that the thermal relaxation times presented in the previous study were actually the thermal lag expected from applying Fourier’s law, taking into account the uncertainty of the temperature sensor. In the second set of experiments, unlike the distinct jumps in temperature found previously, no indication of wave behavior was found. Here, the explanation for the previous results was more difficult to ascertain. Possible explanations include problems with either the experimental protocol or the temperature sensors used.
- 30 April 2007
- Published by Elsevier in Tribology International
- Vol. 40 (4) , 595-600
Coalescence and breakup of contact areas: Effects on surface temperatures
- 30 April 2007
- Published by Elsevier in Tribology International
- Vol. 40 (4) , 595-600
Coalescence and breakup of contact areas: Effects on surface temperatures
- 15 March 2007
- Published by Wolfram Research, Inc. in Complex Systems
- Vol. 17 (1) , 65-78
Multi-physics Modeling Using Cellular Automata
This paper proposes a new modeling and solution method that is relatively simple yet powerful enough to handle complex multi-physics problems. The new methodology is based on a combination of cellular automata, finite difference, and analytical analysis concepts. The basic idea is to construct a cascading sequence of simple, explicit rules of evolution, rather than attempt to solve complicated partial differential equations. The resulting scheme is computationally explicit yet numerically stable. In addition to significant modeling flexibility, the cellular automata environment lends itself to extremely efficient computational algorithms and hardware implementation due to its inherent use of local rules and potential for parallel computation. The power and flexibility of the method is demonstrated by developing solutions for a general transport process consisting of elementary processes due to diffusion, advection, reaction kinetics, and external interaction. Explicit and numerically stable rules for each of these elementary processes are developed. Case studies produce physically realistic and numerically accurate solutions for complex processes. Numerical experiments show that the method is highly accurate if the time step is sufficiently small. The value of the method is that a library of rules for simple, elementary processes can be derived individually. These processes can be assembled in a modular manner in any combination to create models for complex processes. The method is currently being used in a number of applications, including a study of complex thermal/mechanical phenomena at the sliding contacts between rubbing surfaces.
- 15 March 2007
- Published by Wolfram Research, Inc. in Complex Systems
- Vol. 17 (1) , 65-78
Multi-physics Modeling Using Cellular Automata
This paper proposes a new modeling and solution method that is relatively simple yet powerful enough to handle complex multi-physics problems. The new methodology is based on a combination of cellular automata, finite difference, and analytical analysis concepts. The basic idea is to construct a cascading sequence of simple, explicit rules of evolution, rather than attempt to solve complicated partial differential equations. The resulting scheme is computationally explicit yet numerically stable. In addition to significant modeling flexibility, the cellular automata environment lends itself to extremely efficient computational algorithms and hardware implementation due to its inherent use of local rules and potential for parallel computation. The power and flexibility of the method is demonstrated by developing solutions for a general transport process consisting of elementary processes due to diffusion, advection, reaction kinetics, and external interaction. Explicit and numerically stable rules for each of these elementary processes are developed. Case studies produce physically realistic and numerically accurate solutions for complex processes. Numerical experiments show that the method is highly accurate if the time step is sufficiently small. The value of the method is that a library of rules for simple, elementary processes can be derived individually. These processes can be assembled in a modular manner in any combination to create models for complex processes. The method is currently being used in a number of applications, including a study of complex thermal/mechanical phenomena at the sliding contacts between rubbing surfaces.
- 1 January 2002
- Published by ASME International
- p. 201-209
Estimation of the Thermal Properties and Interface Conditions of Heterogeneous Materials
The conjugate gradient method using vectorial descent parameters is used to solve the inverse problem of simultaneously estimating one boundary condition and one thermo-physical property of an heterogeneous material. The advantage of the conjugate gradient method lies in that no a priori information is needed on the variation of the unknown quantities. The heterogeneous material model under consideration consists of a matrix in imperfect contact with embedded separated particles. The first unknown of interest in this inverse problem is the constant coupling parameter Ψ which characterizes the thermal contact (conductance) behavior between the matrix and the particles. The second unknown is the time dependent applied heat flux on one external side of the matrix. As a result, this problem is concerned with a combined parameter and function estimation at the same time. Thus two descent parameters, each one corresponding to each unknown function parameter, are derived and used in the iterative process. The developed inverse analysis is based on the transient temperature measurements taken from some sensors implanted inside the matrix only during the process of heating. Several numerical test cases were performed and show that the developed method provides an accurate estimation of thermo-physical properties and boundary condition in a very short practical time.
- 1 January 2002
- Published by ASME International
- p. 201-209
Estimation of the Thermal Properties and Interface Conditions of Heterogeneous Materials
The conjugate gradient method using vectorial descent parameters is used to solve the inverse problem of simultaneously estimating one boundary condition and one thermo-physical property of an heterogeneous material. The advantage of the conjugate gradient method lies in that no a priori information is needed on the variation of the unknown quantities. The heterogeneous material model under consideration consists of a matrix in imperfect contact with embedded separated particles. The first unknown of interest in this inverse problem is the constant coupling parameter Ψ which characterizes the thermal contact (conductance) behavior between the matrix and the particles. The second unknown is the time dependent applied heat flux on one external side of the matrix. As a result, this problem is concerned with a combined parameter and function estimation at the same time. Thus two descent parameters, each one corresponding to each unknown function parameter, are derived and used in the iterative process. The developed inverse analysis is based on the transient temperature measurements taken from some sensors implanted inside the matrix only during the process of heating. Several numerical test cases were performed and show that the developed method provides an accurate estimation of thermo-physical properties and boundary condition in a very short practical time.