JKJohn Ching Kwong Kwok

John Ching Kwong Kwok

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


John Ching Kwong Kwok has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Alberto Chi Ho Chu

    Department of Neurosurgery, Kwong Wah Hospital, Kowloon, Hong Kong

    1 shared publication
  • Alexander Kar Ngai Lam

    Department of Mechanical Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong

    1 shared publication
  • Kar-Ming Leung

    Department of Neurosurgery, Kwong Wah Hospital, Kowloon, Hong Kong

    1 shared publication
  • Kwong-Yau Chan

    Department of Neurosurgery, Kwong Wah Hospital, Kowloon, Hong Kong

    1 shared publication
  • Siu-Ki Chan

    Department of Pathology, Kwong Wah Hospital, Hong Kong, Kowloon, Hong Kong

    1 shared publication
  • Wei Huang

    Department of Mechanical Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong

    1 shared publication

Latest Publications

  • Open Access

    Human placenta as an ex vivo vascular model for neurointerventional research

    by John Ching Kwong Kwok, Wei Huang, Wing-Cheong Leung, Siu-Ki Chan, Kwong-Yau Chan, Kar-Ming Leung, Alberto Chi Ho Chu, Alexander Kar Ngai Lam

    Background Human placenta is a convenient resource for biomedical research, and has not yet been used for neurointerventional surgery research. Objective Our objective was to explore the feasibility of using human placenta to test various endovascular interventions and for training. Design 18 placentas soon after delivery were prepared for six pilot studies. (1) Study on anatomical similarity to human cerebral vessel. (2) Simulation of stent assisted coiling and flow diversion on an aneurysm model. (3) Simulation of intra-arterial thrombolysis. (4) Simulation of embolization of arteriovenous malformation with glues. (5) Simulation of mechanical thrombolysis and comparison of different devices. (6) Vascular model for training of neurointerventionalists. Results When the chorionic plate vessels were compared with the cerebral cortical vessels, similarities were found in vascular branch patterns, histological cross sections, and angiographic appearances. Due to the semitransparency of its vessel wall, performance of flow diverter and stent assisted coiling of an aneurysm could be visualized under direct microscopic observation. Similarly, timing of clot lysis and glue polymerization could be estimated. Endothelial change after thrombectomy could be assessed by histological methods. From these pilot studies, the placenta model could be adopted to simulate various clinical situations. It is also ideal for interventional radiology training. Conclusions It is feasible to adopt the human placenta as an ex vivo vascular model in neurointerventional surgery research due to the fact that its vessels resemble the brain vasculature.