Rajiv Thapa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rajiv Thapa has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ajay Singh
Khwopa College of Engineering, Tribhuvan University, Bhaktapur 44800, Nepal
1 shared publication - Antonis Papadakis
Department of Electrical Engineering, Frederick University Cyprus, 7, Y. Frederick Str. Pallouriotisa, Nicosia 1036, Cyprus, Cyprus
1 shared publication - Ashish Shrestha
Department of Electrical Engineering, Information Technology and Cybernetics, University of South-Eastern Norway, Porsgrunn N-3918, Norway
1 shared publication - Bijen Mali
NEA Engineering Company, Kathmandu 44600, Nepal
1 shared publication - Brijesh Adhikary
Department of Electrical and Electronics Engineering, Kathmandu University, Dhulikhel 45200, Nepal
1 shared publication - Diwakar Bista
Department of Electrical and Electronic Engineering, Kathmandu University, Dhulikhel 45200, Nepal
1 shared publication
Latest Publications
- Open Access
- 23 July 2019
- Published by MDPI AG in Applied System Innovation
- Vol. 2 (3) , 25
Comparative Study of Different Approaches for Islanding Detection of Distributed Generation Systems
The issue of unintentional islanding in grid interconnection still remains a challenge in grid-connected, Distributed Generation System (DGS). This study discusses the general overview of popular islanding detection methods. Because of the various Distributed Generation (DG) types, their sizes connected to the distribution networks, and, due to the concern associated with out-of-phase reclosing, anti-islanding continues to be an issue, where no clear solution exists. The passive islanding detection technique is the simplest method to detect the islanding condition which compares the existing parameters of the system having some threshold values. This study first presents an auto-ground approach, which is based on the application of three-phase, short-circuit to the islanded distribution system just to reclose and re-energize the system. After that, the data mining-decision tree algorithm is implemented on a typical distribution system with multiple DGs. The results from both of the techniques have been accomplished and verified by determining the Non-Detection Zone (NDZ), which satisfies the IEEE standards of 2 s execution time. From the analysis, it is concluded that the decision tree approach is effective and highly accurate to detect the islanding state in DGs. These simulations in detail compare the old and new methods, clearly highlighting the progress in the field of islanding detection.
- 23 July 2019
- Published by MDPI AG in Applied System Innovation
- Vol. 2 (3) , 25
Open AccessComparative Study of Different Approaches for Islanding Detection of Distributed Generation Systems
The issue of unintentional islanding in grid interconnection still remains a challenge in grid-connected, Distributed Generation System (DGS). This study discusses the general overview of popular islanding detection methods. Because of the various Distributed Generation (DG) types, their sizes connected to the distribution networks, and, due to the concern associated with out-of-phase reclosing, anti-islanding continues to be an issue, where no clear solution exists. The passive islanding detection technique is the simplest method to detect the islanding condition which compares the existing parameters of the system having some threshold values. This study first presents an auto-ground approach, which is based on the application of three-phase, short-circuit to the islanded distribution system just to reclose and re-energize the system. After that, the data mining-decision tree algorithm is implemented on a typical distribution system with multiple DGs. The results from both of the techniques have been accomplished and verified by determining the Non-Detection Zone (NDZ), which satisfies the IEEE standards of 2 s execution time. From the analysis, it is concluded that the decision tree approach is effective and highly accurate to detect the islanding state in DGs. These simulations in detail compare the old and new methods, clearly highlighting the progress in the field of islanding detection.