Neel K. Ranganath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Neel K. Ranganath has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Zachary N. Kon
NYU Langone Hlth, Dept Cardiothorac Surg, 530 First Ave,Ste 9V, New York, NY 10016 USA
6 shared publicationsDeane E. Smith
NYU Langone Hlth, Dept Cardiothorac Surg, 530 First Ave,Ste 9V, New York, NY 10016 USA
4 shared publicationsJad Malas
NYU Langone Hlth, Dept Cardiothorac Surg, 530 First Ave,Ste 9V, New York, NY 10016 USA
4 shared publicationsLuis F. Angel
NYU Langone Hlth, Dept Med, New York, NY 10016 USA
4 shared publications- Bonnie E. Lonze
Department of Surgery NYU Langone Health New York New York USA
3 shared publications Melissa B. Lesko
NYU Langone Hlth, Dept Med, New York, NY 10016 USA
3 shared publications
Latest Publications
- 1 May 2021
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 111 (5) , 1652-1658
High Lung Transplant Center Volume Is Associated With Increased Survival in Hospitalized Patients
- 1 May 2021
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 111 (5) , 1652-1658
High Lung Transplant Center Volume Is Associated With Increased Survival in Hospitalized Patients
- 16 September 2020
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 35 (12) , 3310-3316
Comparison of device‐specific adverse event profiles between Impella platforms
Background The Impella (Abiomed) ventricular support system is a family of temporary mechanical circulatory support (MCS) devices used to treat patients with cardiogenic shock, acute cardiogenic decompensation, and for high‐risk percutaneous or surgical revascularization. These devices include the percutaneously implanted 2.5/cardiac power (CP) and the surgically implanted 5.0/left direct (LD). Despite the beneficial effects and increased usage of these devices, data to assess adverse outcomes and guide clinician decision‐making between the Impella CP and 5.0/LD are limited. Methods This is a retrospective analysis of 91 consecutive patients who required at least 24 h of Impella support, from January 1, 2015 to December 31, 2019. Groups were stratified based on either initial Impella CP or 5.0/LD placement. Clinical outcomes and in‐hospital complications were compared. Results Impella CP was implanted in 66 patients (mean age: 61 ± 15 years, male 71.2%) and Impella 5.0/LD was implanted in 25 patients (mean age: 62 ± 9 years, male 84.0%). There was greater stability of device position (p = .033), less incidence of hemolysis (p < .001), and less frequent need for additional MCS (p = .001) in patients implanted with the Impella 5.0/LD compared with Impella CP in this study cohort. Patients with Impella 5.0/LD were more likely to survive from Impella and survive to discharge. Conclusions This study suggests that for patients who require temporary MCS for more than 24 h, the Impella 5.0/LD may have a more favorable device‐specific adverse profile compared with the Impella CP.
- 16 September 2020
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 35 (12) , 3310-3316
Comparison of device‐specific adverse event profiles between Impella platforms
Background The Impella (Abiomed) ventricular support system is a family of temporary mechanical circulatory support (MCS) devices used to treat patients with cardiogenic shock, acute cardiogenic decompensation, and for high‐risk percutaneous or surgical revascularization. These devices include the percutaneously implanted 2.5/cardiac power (CP) and the surgically implanted 5.0/left direct (LD). Despite the beneficial effects and increased usage of these devices, data to assess adverse outcomes and guide clinician decision‐making between the Impella CP and 5.0/LD are limited. Methods This is a retrospective analysis of 91 consecutive patients who required at least 24 h of Impella support, from January 1, 2015 to December 31, 2019. Groups were stratified based on either initial Impella CP or 5.0/LD placement. Clinical outcomes and in‐hospital complications were compared. Results Impella CP was implanted in 66 patients (mean age: 61 ± 15 years, male 71.2%) and Impella 5.0/LD was implanted in 25 patients (mean age: 62 ± 9 years, male 84.0%). There was greater stability of device position (p = .033), less incidence of hemolysis (p < .001), and less frequent need for additional MCS (p = .001) in patients implanted with the Impella 5.0/LD compared with Impella CP in this study cohort. Patients with Impella 5.0/LD were more likely to survive from Impella and survive to discharge. Conclusions This study suggests that for patients who require temporary MCS for more than 24 h, the Impella 5.0/LD may have a more favorable device‐specific adverse profile compared with the Impella CP.
- 1 August 2020
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 39 (8) , 850-851
Awareness of bias in lung transplant registry analyses
- 1 August 2020
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 39 (8) , 850-851
Awareness of bias in lung transplant registry analyses
- 1 January 2020
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 109 (1) , 211-217
Single and Double Lung Transplantation Have Equivalent Survival for Idiopathic Pulmonary Fibrosis
- 1 January 2020
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 109 (1) , 211-217
Single and Double Lung Transplantation Have Equivalent Survival for Idiopathic Pulmonary Fibrosis
- 1 January 2020
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 32 (4) , 712-717
Robotic Approach to Mitral Valve Surgery in Septo-Octogenarians
- 1 January 2020
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 32 (4) , 712-717
Robotic Approach to Mitral Valve Surgery in Septo-Octogenarians
- 1 November 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (5) , 1464-1470
Impact of the Opioid Epidemic on Lung Transplantation: Donor, Recipient, and Discard Characteristics
- 1 November 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (5) , 1464-1470
Impact of the Opioid Epidemic on Lung Transplantation: Donor, Recipient, and Discard Characteristics
- 26 October 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (12) , 1569-1572
Concomitant temporary mechanical support in high‐risk coronary artery bypass surgery
Objectives Patients with low left ventricular ejection fraction (LVEF) undergoing high‐risk coronary artery bypass grafting (CABG) are at increased risk for postcardiotomy cardiogenic shock. This report describes planned concomitant microaxial temporary mechanical support (MA‐TMS) device placement as a viable bridge‐to‐recovery strategy for high‐risk patients receiving surgical revascularization. Methods A retrospective review was performed for all patients from October 2017 to May 2019 with low LVEF (n = 13). Results Mean patient age was 64.8 years, and 12 patients (92%) were male. Eight patients (62%) presented with acute coronary syndrome. Mean predicted risk of mortality was 4.6%, ranging from 0.6% to 15.6%. An average of 3.4 grafts were performed per patient. Greater than 60% of patients were extubated within 48 hours and out‐of‐bed within 72 hours, and the average duration of MA‐TMS was 5.7 days. Mean postoperative length of stay was 16.7 days. There were no postoperative myocardial infarctions or deaths. Conclusions Prophylactic MA‐TMS may allow safe and effective surgical revascularization for patients with severe left ventricular dysfunction who may otherwise be offered a durable ventricular assist device.
- 26 October 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (12) , 1569-1572
Concomitant temporary mechanical support in high‐risk coronary artery bypass surgery
Objectives Patients with low left ventricular ejection fraction (LVEF) undergoing high‐risk coronary artery bypass grafting (CABG) are at increased risk for postcardiotomy cardiogenic shock. This report describes planned concomitant microaxial temporary mechanical support (MA‐TMS) device placement as a viable bridge‐to‐recovery strategy for high‐risk patients receiving surgical revascularization. Methods A retrospective review was performed for all patients from October 2017 to May 2019 with low LVEF (n = 13). Results Mean patient age was 64.8 years, and 12 patients (92%) were male. Eight patients (62%) presented with acute coronary syndrome. Mean predicted risk of mortality was 4.6%, ranging from 0.6% to 15.6%. An average of 3.4 grafts were performed per patient. Greater than 60% of patients were extubated within 48 hours and out‐of‐bed within 72 hours, and the average duration of MA‐TMS was 5.7 days. Mean postoperative length of stay was 16.7 days. There were no postoperative myocardial infarctions or deaths. Conclusions Prophylactic MA‐TMS may allow safe and effective surgical revascularization for patients with severe left ventricular dysfunction who may otherwise be offered a durable ventricular assist device.
- 23 July 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (10) , 933-940
Early airway dehiscence: Risk factors and outcomes with the rising incidence of extracorporeal membrane oxygenation as a bridge to lung transplantation
Background: Anastomotic complications occur in 7% to 18% of lung transplant recipients, among which airway dehiscence (AD) is particularly catastrophic. Using multi‐institutional registry data, this study compared preoperative recipient/donor risk factors and outcomes in patients with and without AD and analyzed the effect of extracorporeal membrane oxygenation (ECMO) on the incidence of AD. Methods: Data on adult lung transplants from 2007 to 2017 were provided by the Scientific Registry of Transplant Recipients. Patients receiving isolated lobar transplantation and patients with unknown AD status were excluded. Multivariable logistic regression identified independent risk factors for AD. Kaplan‐Meier curves and log‐rank tests describe mortality and graft survival. Results: Of 18 122 lung transplants, 275 (1.5%) experienced AD. While the incidence of ECMO steadily increased from 0.7% to 5.9% over the study period, the incidence of AD remained relatively constant. Multivariable analysis revealed recipient male gender and prolonged ( > 48 hours) posttransplant mechanical ventilation as independent predictive factors for AD, while advanced donor age and single left lung transplant were protective factors. Recipient chronic steroid use, recipient diabetes, donor diabetes, and donor smoking history were not predictive of AD. Mortality and graft failure were significantly worse in the AD group. Conclusions: Despite increased ECMO utilization, the incidence of AD has remained stable. Multiple independent risk factors for AD were identified and poor postoperative outcomes confirmed. However, many known impediments to wound healing such as recipient chronic steroid use, recipient and donor diabetes, and donor smoking were not identified as risk factors for AD, reinforcing the critical role of technical performance.
- 23 July 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (10) , 933-940
Early airway dehiscence: Risk factors and outcomes with the rising incidence of extracorporeal membrane oxygenation as a bridge to lung transplantation
Background: Anastomotic complications occur in 7% to 18% of lung transplant recipients, among which airway dehiscence (AD) is particularly catastrophic. Using multi‐institutional registry data, this study compared preoperative recipient/donor risk factors and outcomes in patients with and without AD and analyzed the effect of extracorporeal membrane oxygenation (ECMO) on the incidence of AD. Methods: Data on adult lung transplants from 2007 to 2017 were provided by the Scientific Registry of Transplant Recipients. Patients receiving isolated lobar transplantation and patients with unknown AD status were excluded. Multivariable logistic regression identified independent risk factors for AD. Kaplan‐Meier curves and log‐rank tests describe mortality and graft survival. Results: Of 18 122 lung transplants, 275 (1.5%) experienced AD. While the incidence of ECMO steadily increased from 0.7% to 5.9% over the study period, the incidence of AD remained relatively constant. Multivariable analysis revealed recipient male gender and prolonged ( > 48 hours) posttransplant mechanical ventilation as independent predictive factors for AD, while advanced donor age and single left lung transplant were protective factors. Recipient chronic steroid use, recipient diabetes, donor diabetes, and donor smoking history were not predictive of AD. Mortality and graft failure were significantly worse in the AD group. Conclusions: Despite increased ECMO utilization, the incidence of AD has remained stable. Multiple independent risk factors for AD were identified and poor postoperative outcomes confirmed. However, many known impediments to wound healing such as recipient chronic steroid use, recipient and donor diabetes, and donor smoking were not identified as risk factors for AD, reinforcing the critical role of technical performance.