Tongliang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tongliang Li has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Chaoyi Pang
School of Computer Science and Data Engineering, NingboTech University, Ningbo, China
3 shared publications - Huanyu Zhao
Hebei Academy of Sciences
3 shared publications - Xiaoyun Li
Institute of Applied Mathematics, Hebei Academy of Sciences, Shijiazhuang, China
2 shared publications Bing Li
Department of Neurology, The First Hospital of Hebei Medical University, Shijiazhuang, China
1 shared publicationChaoyi Pang
The School of Computer and Data Engineering, Zhejiang University (NIT), Ningbo, China
1 shared publication- Christopher K. Pang
University of Queensland, Brisbane, Australia
1 shared publication
Latest Publications
- Open Access
- 18 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 83-87
Alzheimer's Disease Classification Algorithm Based on EEG Microstate
This study developed an analysis method based on Electroencephalography (EEG) microstate features to improve the classification accuracy of Alzheimer's disease patients (AD) and normal controls (NC). Initially, microstate features were extracted from EEG data, and a sliding time window technique was employed to calculate the proportion of microstates within each segment. The microstate feature with the highest proportion was defined as the first component, and its occurrence frequency was statistically weighted to obtain a feature vector for each participant. These features were then input into a support vector machine model for classification training. By leveraging the characteristics of microstates, the method effectively reduced noise interference and decreased computational complexity through segmentation. The use of a sliding time window increased the likelihood of extracting effective features from resting-state EEG data, thereby significantly improving the accuracy of classification. The results of the study indicate that this method has high accuracy and practicality in distinguishing between AD and NC.
- 18 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 83-87
Open AccessAlzheimer's Disease Classification Algorithm Based on EEG Microstate
This study developed an analysis method based on Electroencephalography (EEG) microstate features to improve the classification accuracy of Alzheimer's disease patients (AD) and normal controls (NC). Initially, microstate features were extracted from EEG data, and a sliding time window technique was employed to calculate the proportion of microstates within each segment. The microstate feature with the highest proportion was defined as the first component, and its occurrence frequency was statistically weighted to obtain a feature vector for each participant. These features were then input into a support vector machine model for classification training. By leveraging the characteristics of microstates, the method effectively reduced noise interference and decreased computational complexity through segmentation. The use of a sliding time window increased the likelihood of extracting effective features from resting-state EEG data, thereby significantly improving the accuracy of classification. The results of the study indicate that this method has high accuracy and practicality in distinguishing between AD and NC.
- 26 September 2023
- Published by Springer Nature in Health Information Science and Systems
- Vol. 11 (1) , 1-10
An error-bounded median filter for correcting ECG baseline wander
The baseline wander (BLW) in electrocardiogram (ECG) is a common disturbance that has a significant influence on the ECG wave pattern recognition. Many methods, such as IIR filter, mean filter, etc., can be used to correct BLW; However, most of them work on the original ECG signals. Compressed ECG data are economic for data storage and transmission, and if the baseline correction can be processed on them, it will be more efficient than we decompress them first and then do such correction. In this paper, we propose a new type of median filter CM_Filter, which works on the synopses of straight lines achieved from ECG by piecewise linear approximation (PLA) under maximum error bound. In CM_Filter, a heuristic strategy “Quick-Finding” is deduced by a property of straight lines in order to get the quality-assured median values from the synopses. The extended experimental tests demonstrate that the proposed filter is very efficient in execution time, and effective for correcting both slow and abrupt ECG baseline wander.
- 26 September 2023
- Published by Springer Nature in Health Information Science and Systems
- Vol. 11 (1) , 1-10
An error-bounded median filter for correcting ECG baseline wander
The baseline wander (BLW) in electrocardiogram (ECG) is a common disturbance that has a significant influence on the ECG wave pattern recognition. Many methods, such as IIR filter, mean filter, etc., can be used to correct BLW; However, most of them work on the original ECG signals. Compressed ECG data are economic for data storage and transmission, and if the baseline correction can be processed on them, it will be more efficient than we decompress them first and then do such correction. In this paper, we propose a new type of median filter CM_Filter, which works on the synopses of straight lines achieved from ECG by piecewise linear approximation (PLA) under maximum error bound. In CM_Filter, a heuristic strategy “Quick-Finding” is deduced by a property of straight lines in order to get the quality-assured median values from the synopses. The extended experimental tests demonstrate that the proposed filter is very efficient in execution time, and effective for correcting both slow and abrupt ECG baseline wander.
- 26 July 2022
- Published by Springer Nature in Health Information Science and Systems
- Vol. 10 (1) , 1-10
Microstate feature fusion for distinguishing AD from MCI
Electroencephalogram (EEG) microstates provide powerful tools for identifying EEG features due to their rich temporal information. In this study, we tested whether microstates can measure the severity of Alzheimer’s disease (AD) and mild cognitive impairment (MCI) in patients and effectively distinguish AD from MCI. We defined two features using transition probabilities (TPs), and one was used to evaluate between-group differences in microstate parameters to assess the within-group consistency of TPs and MMSE scores. Another feature was used to distinguish AD from MCI in machine learning models. Tests showed that there were between-group differences in the temporal characteristics of microstates, and some kinds of TPs were significantly correlated with MMSE scores within groups. Based on our newly defined time-factor transition probabilities (TTPs) feature and partial accumulation strategy, we obtained promising scores for accuracy, sensitivity, and specificity of 0.938, 0.923, and 0.947, respectively. These results provide evidence for microstates as a neurobiological marker of AD.
- 26 July 2022
- Published by Springer Nature in Health Information Science and Systems
- Vol. 10 (1) , 1-10
Microstate feature fusion for distinguishing AD from MCI
Electroencephalogram (EEG) microstates provide powerful tools for identifying EEG features due to their rich temporal information. In this study, we tested whether microstates can measure the severity of Alzheimer’s disease (AD) and mild cognitive impairment (MCI) in patients and effectively distinguish AD from MCI. We defined two features using transition probabilities (TPs), and one was used to evaluate between-group differences in microstate parameters to assess the within-group consistency of TPs and MMSE scores. Another feature was used to distinguish AD from MCI in machine learning models. Tests showed that there were between-group differences in the temporal characteristics of microstates, and some kinds of TPs were significantly correlated with MMSE scores within groups. Based on our newly defined time-factor transition probabilities (TTPs) feature and partial accumulation strategy, we obtained promising scores for accuracy, sensitivity, and specificity of 0.938, 0.923, and 0.947, respectively. These results provide evidence for microstates as a neurobiological marker of AD.
- Open Access
- 25 August 2020
- Published by MDPI AG in Electronics
- Vol. 9 (9) , 1374
Smart Image Enhancement Using CLAHE Based on an F-Shift Transformation during Decompression
As technologies for image processing, image enhancement can provide more effective information for later data mining and image compression can reduce storage space. In this paper, a smart enhancement scheme during decompression, which combined a novel two-dimensional F-shift (TDFS) transformation and a non-standard two-dimensional wavelet transform (NSTW), is proposed. During the decompression, the first coefficient s00 of the wavelet synopsis was used to adaptively adjust the global gray level of the reconstructed image. Next, the contrast-limited adaptive histogram equalization (CLAHE) was used to achieve the enhancement effect. To avoid a blocking effect, CLAHE was used when the synopsis was decompressed to the second-to-last level. At this time, we only enhanced the low-frequency component and did not change the high-frequency component. Lastly, we used CLAHE again after the image reconstruction. Through experiments, the effectiveness of our scheme was verified. Compared with the existing methods, the compression properties were preserved and the image details and contrast could also be enhanced. The experimental results showed that the image contrast, information entropy, and average gradient were greatly improved compared with the existing methods.
- 25 August 2020
- Published by MDPI AG in Electronics
- Vol. 9 (9) , 1374
Open AccessSmart Image Enhancement Using CLAHE Based on an F-Shift Transformation during Decompression
As technologies for image processing, image enhancement can provide more effective information for later data mining and image compression can reduce storage space. In this paper, a smart enhancement scheme during decompression, which combined a novel two-dimensional F-shift (TDFS) transformation and a non-standard two-dimensional wavelet transform (NSTW), is proposed. During the decompression, the first coefficient s00 of the wavelet synopsis was used to adaptively adjust the global gray level of the reconstructed image. Next, the contrast-limited adaptive histogram equalization (CLAHE) was used to achieve the enhancement effect. To avoid a blocking effect, CLAHE was used when the synopsis was decompressed to the second-to-last level. At this time, we only enhanced the low-frequency component and did not change the high-frequency component. Lastly, we used CLAHE again after the image reconstruction. Through experiments, the effectiveness of our scheme was verified. Compared with the existing methods, the compression properties were preserved and the image details and contrast could also be enhanced. The experimental results showed that the image contrast, information entropy, and average gradient were greatly improved compared with the existing methods.
- 17 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Knowledge and Data Engineering
- Vol. 34 (10414347) , 1
An Optimal Online Semi-connected PLA Algorithm with Maximum Error Bound
Piecewise Linear Approximation (PLA) is one of the most widely used approaches for representing a time series with a set of approximated line segments. With this compressed form of representation, many large complicated time series can be efficiently stored, transmitted and analyzed. In this article, with the introduced concept of “semi-connection” that allowing two representation lines to be connected at a point between two consecutive time stamps, we propose a new optimal linear-time PLA algorithm SemiOptConnAlg for generating the least number of semi-connected line segments with guaranteed maximum error bound. With extended experimental tests, we demonstrate that the proposed algorithm is very efficient in execution time and achieves better performances than the state-of-art solutions.
- 17 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Knowledge and Data Engineering
- Vol. 34 (10414347) , 1
An Optimal Online Semi-connected PLA Algorithm with Maximum Error Bound
Piecewise Linear Approximation (PLA) is one of the most widely used approaches for representing a time series with a set of approximated line segments. With this compressed form of representation, many large complicated time series can be efficiently stored, transmitted and analyzed. In this article, with the introduced concept of “semi-connection” that allowing two representation lines to be connected at a point between two consecutive time stamps, we propose a new optimal linear-time PLA algorithm SemiOptConnAlg for generating the least number of semi-connected line segments with guaranteed maximum error bound. With extended experimental tests, we demonstrate that the proposed algorithm is very efficient in execution time and achieves better performances than the state-of-art solutions.
- 24 July 2019
- Published by Springer Nature in Health Information Science and Systems
- Vol. 7 (1) , 1-8
Medical image enhancement in F-shift transformation domain
Image enhancement technology plays an important role in the diagnosis and treatment of medical diseases. In this paper, we propose a method to automatically enhance medical images. The proposed method could be used to support clinical medical diagnosis, adjuvant therapy and curative effect diagnosis. This scheme uses contrast limited adaptive histogram equalization (CLAHE) method in F-shift transformation domain. Firstly, we adjust the overall brightness of the underexposed or overexposed image. Secondly, we perform CLAHE to enhance the low-frequency components obtained by one-level two-dimensional F-shift transformation (TDFS) on the adjusted images. At this stage, most of the coefficients in the high-frequency component can be changed to zero through properly setting the error bound. We then use inverse transformation to reconstruct image which is further enhanced with CLAHE. Compared to previous work, this approach takes into account not only the image enhancement, but also the data compression. Experimental results and comparison with state-of-the-art methods show that our proposed method has a better enhancement performance. Moreover, it has a certain data compression ability.
- 24 July 2019
- Published by Springer Nature in Health Information Science and Systems
- Vol. 7 (1) , 1-8
Medical image enhancement in F-shift transformation domain
Image enhancement technology plays an important role in the diagnosis and treatment of medical diseases. In this paper, we propose a method to automatically enhance medical images. The proposed method could be used to support clinical medical diagnosis, adjuvant therapy and curative effect diagnosis. This scheme uses contrast limited adaptive histogram equalization (CLAHE) method in F-shift transformation domain. Firstly, we adjust the overall brightness of the underexposed or overexposed image. Secondly, we perform CLAHE to enhance the low-frequency components obtained by one-level two-dimensional F-shift transformation (TDFS) on the adjusted images. At this stage, most of the coefficients in the high-frequency component can be changed to zero through properly setting the error bound. We then use inverse transformation to reconstruct image which is further enhanced with CLAHE. Compared to previous work, this approach takes into account not only the image enhancement, but also the data compression. Experimental results and comparison with state-of-the-art methods show that our proposed method has a better enhancement performance. Moreover, it has a certain data compression ability.
- 9 June 2015
- Published by Springer Nature in International Journal of Machine Learning and Cybernetics
- Vol. 9 (2) , 243-249
Analyze EEG signals with extreme learning machine based on PMIS feature selection
- 9 June 2015
- Published by Springer Nature in International Journal of Machine Learning and Cybernetics
- Vol. 9 (2) , 243-249
Analyze EEG signals with extreme learning machine based on PMIS feature selection
- 1 January 2010
- Published by European Alliance for Innovation n.o.
Keeping it under control: A new authentication scheme for RFID tags
- 1 January 2010
- Published by European Alliance for Innovation n.o.
Keeping it under control: A new authentication scheme for RFID tags