JLJia-Ling Liu

Jia-Ling Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jia-Ling Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Chao Ma

    Department of Radiology, Changhai Hospital of Shanghai, Naval Medical University, Shanghai, 200433, China

    1 shared publication
  • Peng Yi Peng

    Shanghai Univ Tradit Chinese Med, Putuo Hosp, Dept Radiol, Shanghai 200062, Peoples R China

    1 shared publication
  • Xiang Zhou

    Department of Radiology, Tongji Hospital, Tongji University School of Medicine, Shanghai 200065, China

    1 shared publication
  • Yuan-Peng Rui

    Department of Radiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, 164 LanXi Road, Putuo District, Shanghai, 200062, China

    1 shared publication
  • Yuehua Li

    Department of Radiology, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

    1 shared publication
  • Zhi Wang

    Department of Radiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, 164 LanXi Road, Putuo District, Shanghai, 200062, China

    1 shared publication

Latest Publications

  • Open Access

    Effect of region of interest on ADC and interobserver variability in thyroid nodules

    by Xiang Zhou, Chao Ma, Zhi Wang, Jia-Ling Liu, Yuan-Peng Rui, Yue-Hua Li, Yi-Feng Peng

    To determine the effect of region of interest (ROI) on tumor’s apparent diffusion coefficient (ADC) and interobserver variability in thyroid nodules. Thirty-three individuals with 45 pathologically-confirmed thyroid nodules were assessed by preoperative diffusion-weighted imaging (DWI) with b values of 0 and 400 s/mm2, respectively. Two readers evaluated the ADC values of lesions based on three ROI techniques: whole-volume, single-slice and small solid-sample groups. Interobserver variability was analyzed for all ROI techniques, and the mean ADCs of benign and cancerous thyroid nodules were compared. For the mean ADCs of non-cancerous thyroid nodules, average differences and limits of agreement (LOAs) between readers were 0.00 [− 0.17–0.17] × 10− 3 mm2/s for whole-volume ROI (ICC = 0.967), 0.00 [− 0.26–0.26] × 10− 3 mm2/s for single-slice ROI (ICC = 0.932) and − 0.02 [− 0.38–0.41] × 10− 3 mm2/s for small solid-sample ROI (ICC = 0.823). For the mean ADCs of cancerous thyroid nodules, average differences and LOAs between readers were − 0.05 [− 0.23–0.13] × 10− 3 mm2/s (ICC = 0.885), 0.01 [− 0.23–0.25] × 10− 3 mm2/s (ICC = 0.839) and − 0.07 [− 0.52–0.39] × 10− 3 mm2/s (ICC = 0.579) for the three ROI methods, respectively. The mean ADC values were more scattered in the small solid-sample ROI group in comparison with the whole-volume and single-slice groups, in noncancerous and cancerous specimens. Of all three ROI techniques, whole-volume ROI-determined ADC had the highest combined sensitivity (80.0%), specificity (88.3%) and Youden index (0.683), with a cut-off of 1.84 × 10− 3 mm2/s. The ROI method overtly affects ADC measurements in benign and cancerous thyroid nodules. Small solid-sample ROI yielded the worst interobserver variability of average ADC measurements.